DOCUMENTS Initial Application Date:06/06/18 Application it Ix<S Vt41-1 abt-0 CU# COUNTY OF HARNETT RESIDENTIAL LAND USE APPLICATION Central Permitting 108 E.Front Street,Lillington,NC 21548 Phone:(910)893-7525 ext:2 Fax:(910)893-2793 www hamett.org/permits "A RECORDED SURVEY MAP,RECORDED DEED(OR OFFER TO PURCHASE)8.SITE PLAN ARE REQUIRED WHEN SUBMITTING A LAND USE APPLICATION" LANDOWNER:Jonas Amaral Mailing Address:186 Kentucky Derby Lane City: Lillington State:NC Zip:27546 Contact No: 774-955-2056 Email: APPLICANT':Peter Denicola Mailing Address:919 N Main Street City: Mooresville State:C Zip:28115 Contact No' 704-209-9893 Email. mjarvis@powerhome.com 'Please fill out applicant inhnnaUon If different than landowner CONTACT NAME APPLYING IN OFFICE:Megan Jarvis �'7 rrr...000 Phone#704-209--9693 I1 PROPERTY LOCATION:Subdivision: T?Y1'TCY Jr.- . C Lot#: l Lot Size: r If'Iq State Road#186 State Road Name: Kentucky Derby Map Book 8 Page:&Oj� / /S Parcel: 030507 0200 11 PIN: 05077-�-04-555( d9/4.00000 Zoning El Zone: 7 Watershed: Deed Book 8 Page: "�.J 1 U/ /0 Power Company': Duke Energy 'New structures with Progress Energy as service provider need to supply premise number from Progress Energy. PROPOSED USE: Monolithic ❑ SFD:(Size x )#Bedrooms:_#Baths:_Basement(w/wo bath):_Garage: Deck:_Crawl Space:_Slab:_Slab:_ Os the bonus room finished?(_)yes (_)no w/a closet?( )yes ( )no(if yes add in with#bedrooms) U Mod:(Size x )4 Bedrooms_4 Baths_Basement(w/wo bath) Garage:_Site Built Deck:_ On Frame OR Frame_ (Is the second floor finished?(—)yes (_)no Any other site built additions?( .)yes (___)no ❑ Manufactured Home:_SW_DW_TW(Size x )#Bedrooms:_Garage: (site built?_)Deck: (site built?_) ❑ Duplex:(Size_x_)No.Buildings: No.Bedrooms Per Unit: ❑ Home Occupation'#Rooms: Use: n �Hourss of Operation: #Employees: ❑ Addition/AccessorylOther:(Size x )Use: 04..44 PW WJk-stTh Closets in addition?( )yes (_)no Iv Water Supply: County Existing Well New elldwellings using well )'Must have operable water before final Sewage Supply: New Septic Tank(Complete Checklist) Existing Septic Tank(Complete Checklist _County Sewer Does owner of this tract of and.own land that contains a manufactured home within five hundred feet(500')of tract listed above?(_)yes (_)no Does the pro_my contain any easements whether undergroundLor overhead(_)yes (__J no Structures exis0 proposed):Single family dwellings: T-Z1c\k Manufactured Homes: Other(specify): Required Residential Property Line Setbacks: Comments:30 roof mounted modules,grid tied,8.85 KW solar installation Front Minimum Actual on existing residence Rear Closest Side Sidestreeucorner lot Nearest Building _ on same lot Residential Land Use Application Page 1 of 2 03/11 APPLICATION CONTINUES ON BACK SPECIFIC DIRECTIONS TO THE PROPERTY FROM LILLINGTON: Head West on E Front Street towards S 1st Street Turn left onto S Main St Turn right onto W Old Rd Turn left onto NC-27 W Turn left onto Docs Rd Turn right onto Kentucky Derby Ln Destination will be on the right If permits are granted I agree to conform to all ordinances and laws of the State of North Carolina regulating such work and the specifications of plans submitted. I hereby state that foregoing statements are accurate and correct to the best of my knowledge. Permit subject to revocation if false information is provided. 06/06/18 Signature of Owner or Owner's Agent Date "it is the ownerlapplicants responsibility to provide the county with any applicable information about the subject property,Including but not limited to:boundary information,house location,underground or overhead easements,etc.The county or its employees are not responsible for any incorrect or missing information that is contained within these applications."' "This application expires 6 months from the Initial date if permits have not been Issued" • Residential Land Use Application Page 2 of 2 03/11 09/09111 Application# Harnett County Central Permitting PO Box 85 Lallingten NC 27546 Each section below to be Med out 910 893 7525 Fax 910 893 2793 www Kamen orwrpermds by whomever performing work Must be owner or licensed contractor Address company Application for Residential Building and Trades Permit name 8 phone must match Owners Name Jonas Amaral Date 06/06/18 Site Address 186 Kentucky Derby Lane,Lillington,NC 27546 Phone 774-955-2056 Directions to job site from Lillington on land use application Subdivision Lot 30 roof mounted modules.grid tied,8.85 KW solar installation on Description of Proposed Work existing residence #of Bedrooms Heated SF Unheated SF Finished Bonus Room? Crawl Space Slab General Contractor Information Power Home Solar 704-209-9893 Building Contractors Company Name Telephone 919 N Main Street,Mooresville,NC 28115 miarvis@powerhome.com Address Email Address 60946 License# Electrical Contractor Information Description of Work same as above Service Size _Amps T-Pole _Yes_No Power Home Solar 704-209-9893 Electrical Contractors Company Name Telephone 919 N Main Street,Mooresville.NC 28115 miarvis@powerhome.com Address Email Address 26074-U License# )MechanicallHVAC Contractor Information Descnption of Work Mechanical Contractors Company Name Telephone Address Email Address License# Plumbing Contractor Information Description of Work #Baths Plumbing Contractors Company Name Telephone Address Email Address License# Insulation Contractor Information Insulation Contractors Company Name&Address Telephone *NOTE General Contractor must fill out and sign the second page of this application I hereby certify that I have the authority to make necessary application that the application is correct and that-the construction will conform to the regulations in the Building Electrical Plumbing and Mechanical codes and the Hamett County Zoning Ordinance I state the information on the above contractors Is correct as known to me and that by mama below I have obtained all subcontractors permission to obtain these permits and if Kw changes occur including listed contractors site plan number of bedrooms building and trade plans Environmental Health permit changes or proposed use changes I certify it is my responsibility to notify the Harnett County Central Permitting Department of any and all changes EXPIRED PERMIT FEES-6 Months $15 to 2 years permit re-issue fee is 0 00 After 2 years re-issue fee is as per current fee schedule n O V 06/06/18 Signature of Owner/Contractor/Officer(s)of Corporation Date Affidavit for Worker's Compensation NC GS 87-14 The undersigned applicant being the x General Contractor _Owner x Officer/Agent of the Contractor or Owner Do hereby confirm under penalties of perjury that the person(s) firm(s)or corporation(s)performing the work set forth in the permit x Has three(3)or more employees and has obtained workers compensation insurance to cover them Has one(1)or more subcontractors(s)and has obtained workers compensation insurance to cover them Has one(1)or more subcontractors(s)who has their own policy of workers compensation insurance covenng themselves Has no more than two(2)employees and no subcontractors While working on the project for which this permit is sought it is understood that the Central Permitting Department issuing the permit may require certificates of coverage of workers compensation insurance pnor to issuance of the permit and at any time dunng the permitted work from any person firm or corporation carrying out the work Company or Name Peter Demcola /Power Home Solar LLC Sign wITitle en0v General Contractor Date 06/06/18 Structural Capacity, PC STRUCTURAL CONSULTING GROUP North Carolina Firm License Number—C3406 June 05,2018 .o.0.0.‘(CARO(��� oFtr8Q(. N('7��� Mr.Sarah Brooks Xl. Power Home Solar _ SEAL 919 N Main Street,Suite 200 _ 033700 " Mooresville,NC 28115 06(05/2018 Re: Amaral,Jonas(SCPC Project No.—2018.71.0980) 6 4 '•Q'G(NEEP.•jr 186 Kentucky Derby Ln. ,A(y S. " J. Lillington,NC 27546 Dear Ms. Brooks: At the request of Power Home Solar(PHS),Structural Capacity, PC(SCPC) has evaluated the roof structure at the Amaral Residence located in Lillington, North Carolina to determine its adequacy to support the attachment of roof mounted solar arrays. It is the understanding of SCPC that PH5 is proposing to install (30)Mission Solar Energy 295 watt photovoltaic(PV) modules on the roof structure. The roof structure is composed of wood sheathing supported by pre-engineered wood trusses spaced at approximately 24 inches on center. The design roof live load is 20 psf. The ground snow load is 10 psf. The design wind speed for the location is 100 mph per ASCE 7-05. Each panel will be supported by(2)mounting rails, (1)at each end. The mounting legs of the solar panel railing will be attached directly to the truss top chord with a 5/16 inch diameter lag screw. The installer shall use best practice construction methods to locate the lag screw in the center of each truss top chord. Per NDS Section 11.1.4, lead holes should be bored into the primary framing member to avoid splitting. All truss members supporting PV modules should consist of sound lumber without significant signs of deterioration. The mounting legs of the solar panel racking system shall be located at 4'-0" o.c. maximum. The mounting legs should be staggered at the primary framing member spacing(2'-0")at adjacent solar panel rails. The maximum rail cantilever span should be limited to 1'-4". The existing roof structure is adequate to support the solar panel loading, if installed in accordance with the above stated conditions. If any conditions are found in conflict with those stated above,SCPC should be made aware immediately for re-evaluation and report amendment, as applicable, before proceeding with solar panel installation. Sincerely, Structural Capacity, PC Adrian S.Durham,PE,SE,LEED AP 21S N95']ING11OUSE 131 VI)SI FITE 203 CI(ARI OTTE.NC'2E273 7040003706 Structural Capacity, PC STRUCTURAL CONSULTING GROUP • North Carolina Firm License Number—0406 lune 05,2018 ,:P(H CARO FES /o Mr.Sarah Brooks Power Home Solar SEAL 919 N Main Street,Suite 200 033 • 700 Mooresville,NC 28115 06/05/2018 Re: Amaral,Jonas(SCPC Project No.—2018.71.0980) 9j ...NE. `t` 186 Kentucky Derby Ln. •,%qN S. Duro' Lillington, Lillington, NC 27546 Dear Ms.Brooks: At the request of Power Home Solar(PHS),Structural Capacity,PC(SCPC)has evaluated the roof structure at the Amaral Residence located in Lillington, North Carolina to determine its adequacy to support the attachment of roof mounted solar arrays. It is the understanding of SCPC that PHS is proposing to install (30)Mission Solar Energy 295 watt photovoltaic WV)modules on the roof structure. The roof structure is composed of wood sheathing supported by pre-engineered wood trusses spaced at approximately 24 inches on center. The design roof live load is 20 psf. The ground snow load is 10 psf. The design wind speed for the location is 100 mph per ASCE 7-05. Each panel will be supported by(2) mounting rails,(1)at each end. The mounting legs of the solar panel railing will be attached directly to the truss top chord with a 5/16 inch diameter lag screw. The installer shall use best practice construction methods to locate the lag screw in the center of each truss top chord. Per NDS Section 11.1.4, lead holes should be bored into the primary framing member to avoid splitting. All truss members supporting PV modules should consist of sound lumber without significant signs of deterioration. The mounting legs of the solar panel racking system shall be located at 4'-0" o.c. maximum. The mounting legs should be staggered at the primary framing member spacing(2'-0")at adjacent solar panel rails. The maximum rail cantilever span should be limited to 1'-4". The existing roof structure is adequate to support the solar panel loading, if installed in accordance with the above stated conditions. If any conditions are found in conflict with those stated above,SCPC should be made aware immediately for re-evaluation and report amendment, as applicable, before proceeding with solar panel installation. Sincerely, Structural Capacity,PC Adrian S. Durham,PE,SE,LEED AP 218 WESTINGI 101 ISF BLVD SI 13TH 203 ClIANI ATTE.NC 28273 704900.8706