Loading...
17-50042889, Little Miracles DaycarePlan Review, Inspection, and Permit Fees Application Number :17-50042889 $200.00 Explosive Material (90 Days) $100.00 Explosive Materials (72 Hours) $100.00 Fireworks Public Display $50.00 Final Inspection $35.00 + $2.00 per device Fire Alarm Testing $35.00 + $2.00 per nozzle Fixed Fire Suppression $75.00 Insecticide Fog/Fumigation $100.00 Pipe Test/UST/AGST $50.00 Plans up to 5000 sq ft $100.00 Plans 5001 sq ft to 10,000 sq ft $150.00 Plans 10,001 sq ft to 25,000 sq ft $250.00 Plans 25,001 sq ft and over $35.00 + 2.00 per head Sprinkler Certification Test $50.00 Standpipe Testing $50.00 Special Assembly (ie. amusement buildings, carnivals, fairs)$75.00 Tents/Canopies/Air Supported Structure $100.00 Tank Installation (charge for each tank) $100.00 Tank Removal (charge for each tank) Total Devices/Heads Total Cost Code Enforcement Official D. Banks Wallace $ - $ - $ - $ 50.00 $ - $ - $ - $ - $ 50.00 $ - $ - $ - $ - $ - $ - $ - $ - $ - $ - $ 100.00 5/10/2018 Plan Review, Inspection, and Permit Fees Fire Marshal Division May 8, 2018 Al Mosley 1497 NC 24/87 Cameron, NC 28326 Re: Little Miracles Daycare Application Numbers – 17-50042889 Mr. Gregory, Thank you for submitting the plans for the Little Miracles mobile classroom. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below.  1003.2.11 Means of egress illumination. o The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied o The portion of the exterior exit discharge immediately adjacent to exit discharge doorways in buildings required to have two or more exits.  906.1 Fire Extinguishers o Fire extinguishers shall be located as not to exceed 75’ of travel distance to an extinguisher. o The fire extinguishers provided shall have a minimum rating of 2A10:BC and shall not be installed higher than 5 feet above the finished floor.  404.2 Fire Safety and Evacuation Plans o An approved fire safety and evacuation plan shall be prepared, posted and maintained for Group E occupancies.  Fire Department Access o The fire department access shall extend to within 150 feet of all portions of the facility. o The fire department access road shall be of an unobstructed width of not less than 20 feet and shall have an unobstructed vertical clearance of not less the 13 feet 6 inches.  Fire Alarm System o Fire alarm plans shall be submitted for review and approval. o The fire alarm system plans shall bear the seal of a licensed P.E. within the state of North Carolina.  Spec Sheets shall be submitted for all fire alarm system devices.  Any changes to the fire alarm system shall bear the seal of approval of a P.E.  Pull stations required at exits from nursery.  Notes o Please provide fire extinguisher locations, FACP location, smoke detector locations o See note on drawing referencing door swing reversal o Please schedule all fire inspections with the Fire Marshal’s Office. o 910-893-0743 Thank you again for submitting the plans for the mobile classroom. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office Again, thank you and we look forward to working with you during the construction period! Sincerely, D. Banks Wallace Chief Deputy Fire Marshal October 23, 2017 VALID R. JOHNSON APPROVED 10 24 2017 October 23, 2017 VALID R. JOHNSON APPROVED 10 24 2017 October 23, 2017 VALID R. JOHNSON APPROVED 10 24 2017 October 23, 2017 VALID R. JOHNSON APPROVED 10 24 2017 October 23, 2017 VALID R. JOHNSON APPROVED 10 24 2017