Loading...
INSPECTION W/ ENG LETTER PREPA 5/09/18, 14:06:08 INSPECTION TICKET PAGE 34 Ha Ynet oulty INSPECTOR: IVR DATE 5/10/18 ADDRESS . : 192 MILLWOOD LN SUBDIV: ADAMS FARMS SUBDIVISION CONTRACTOR : PHONE : OWNER . . : COOPER ROBIN W JT W/ROS & WOOD PHONE : PARCEL . . : 04-0673- - -0121- -12- APPL NUMBER: 18-50043039 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 01/08/2018 08:59 AM LLUCaS ---- TRAVEL HWY 210 TOWARDS HWY 55 IN ANGIER - MILLWOOD LN WILL BE ON YOUR RIGHT - THE LOT IS THE LAST ONE ON THE RIGHT - THE ONLY LOT WITHOUT A HOUSE BUILT STRUCTURE: 000 000 54X60 4BDR 3BTH N/GARAGE CRWL FLOOD ZONE • FLOOD ZONE X # BATHS • 3 # BEDROOMS - 4.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW SEPTIC WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD . REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS A814 01 2/14/18 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 003089042 2/15/18 AP 192 MILLWOOD LN ANGIER 27501 T/S: 02/15/2018 11:04 AM SBENNETT B101 01 2/20/18 MC R*BLDG FOOTING / TEMP SVC POLE VRU #: 003091371 2/20/18 AP T/S: 02/20/2018 03 :09 PM MCOOK 1. did not inspect 5 deck footing will check at later time B103 01 3/12/18 MC R*BLDG FOUND & TEMP SVC POLE VRU #: 003099881 3/12/18 AP T/S: 03/12/2018 02:02 PM MCOOK B101 02 3/15/18 MC R*BLDG FOOTING / TEMP SVC POLE VRU #: 003101912 3/15/18 AP T/S: 03/15/2018 01:43 PM MCOOK 1. called in at 9:15am B105 01 3/19/18 MC R*OPEN FLOOR VRU #: 003101841 3/19/18 DA T/S: 03/19/2018 02:23 PM MCOOK 1. 31v1 support on 2-2x10 header at crawl door , need engineer of record to look at to make sure load ok R425 01 4/24/18 MC FOUR TRADE ROUGH IN VRU #: 003116860 4/24/18 DA HVAC and Plumbing would like to be there during the inspection. If you could please text or call me Tuesday morning at 919-414-6534 so I can let them know an estimated time you will be at the house that would be great! Thank you 0/S: 04/24/2018 03:52 PM MCOOK 1. properly install (attach) firebox 2 . properly flash around front porch 3 . install all air barrier where required 4 . install all fire/draft stop 5. install baffles upstairs 6. missing nail plate at hall bath behind shower valve 7. air test low R425 02 4/30/18 MC FOUR TRADE ROUGH IN VRU #: 003119872 4/30/18 AP If you can make it the afternoon of Friday the 27th that would be great. If not, have a great weekend! T/S: 04/30/2018 03:25 PM MCOOK 1129 01 5/07/18 TI R*INSULATION INSPECTION VRU #: 003123320 5/04/18 CA The front and back porch concrete are supposed to be done on Monday (I hope) , as well as the garage. If there is anyway for someone to come early for the inspection that CONTINUED ONTO NEXT PAGE PREP . ' 5/09/18, 14:06:08 INSPECTION TICKET PAGE - 35 Hamel Cou ty INSPECTOR: IVR DATE 5/10/18 ADDRESS . : 192 MILLWOOD LN SUBDIV: ADAMS FARMS SUBDIVISION CONTRACTOR : PHONE : OWNER . . : COOPER ROBIN W ST W/ROS & WOOD PHONE : PARCEL . . : 04-0673- - -0121- -12- APPL NUMBER: 18-50043039 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS would be great. Otherwise we may need to get a rope to swing over the front porch! : ) 8105 02 5/09/18 TI R*OPEN FLOOR VRU #: 003123809 5/07/18 CA I129 02 5/09/18 TI R*INSULATION INSPECTION VRU #: 003123742 5/07/18 CA If possible, please inspect in the morning. Thanks so much! 8105 03 5/10/18 TI _ R*OPEN FLOOR VRU #: 003124666 11 My! I129 03 5/10/18 T$ R*INSULATION INSPECTION VRU #: 003124674 14 . COMMENTS AND NOTES 1 • Mark , Jones, P Structural ngineerinq and nesign March 20,2018 Karen Wood 192 Millwood Lane Angier,NC 27501 Ref: Site Observations and Analysis 192 Millwood Lane Angier, NC Project No. 17-298 To Whom it may concern; The above referenced site was observed on March 19, 2018 for the following items: 1. Verify header above crawl access. Based on analysis, the conclusions regarding the condition(s) are: 1. The builder has provided a 2-2x 10 header across the crawl access opening. There is floor and roof load as well as a point load at this location. The 2-2x10 header is adequate to support the imposed loads. No action is required. Thank you for this opportunity to ass�sj� iiiit If you have any questions or need any further assistance, please do not hesitat`4ptll \IICARpy ori., Respectfully, /1 � s4O``'��oFessia4q:�99 iiiI h Tot li I Q✓' 20-08 '� Zj`:FNGINEEP. S Mark E. Jones, PE r�ion'1E.111.1 $'sus 6425 Glen Dean Court • Raleigh, NC 27603 • phone: (919) 395-5618