APPROVED FM PLANSPlan Review, Inspection, and Permit Fees Application Number :18-50043307 $200.00 Explosive Material (90 Days) $100.00 Explosive Materials (72 Hours) $100.00 Fireworks Public Display $50.00 Final Inspection $35.00 + $2.00 per device Fire Alarm Testing $35.00 + $2.00 per nozzle Fixed Fire Suppression $75.00 Insecticide Fog/Fumigation $100.00 Pipe Test/UST/AGST $50.00 Plans up to 5000 sq ft $100.00 Plans 5001 sq ft to 10,000 sq ft $150.00 Plans 10,001 sq ft to 25,000 sq ft $250.00 Plans 25,001 sq ft and over $35.00 + 2.00 per head Sprinkler Certification Test $50.00 Standpipe Testing $50.00 Special Assembly (ie. amusement buildings, carnivals, fairs)$75.00 Tents/Canopies/Air Supported Structure $100.00 Tank Installation (charge for each tank) $100.00 Tank Removal (charge for each tank) 62 Total Devices/Heads Total Cost Code Enforcement Official D. Banks Wallace $ - $ - $ - $ 50.00 $ 35.00 $ - $ - $ - $ - $ - $ 150.00 $ - $ - $ - $ - $ - $ - $ - $ 124.00 $ 359.00 5/11/2018 Plan Review, Inspection, and Permit Fees Fire Marshal Division May 10, 2018 Amy Labadie 814 Developments, LLC 3221 W. Big Beaver Suite 111 Troy, MI 48084 RE: Rainbow Child Care Center 95 Centennial Parkway Spout Springs, NC 28326 Application Number: 18-50043307 Ms. Labadie, Thank you for submitting plans for the new day care facility. The plans have been reviewed by a qualified code enforcement official for compliance with the North Carolina Fire Prevention code and all other fire protection regulations. The following are items that will need to be addressed before a final inspection of this project can be completed. The items are listed and described below.  503 Fire Department Access o The fire department access shall extend to within 150 feet of all portions of the facility (current driveway and parking lot may suffice). o The fire department access road shall be of an unobstructed width of not less than 20 feet and shall have an unobstructed vertical clearance of not less the 13 feet 6 inches.  505.1 Physical Address o The physical address of the building shall be posted in a conspicuous place so that it can be seen on approach from the road, access road, and/or parking lot. o The numbers used to make up the physical address shall be at least 5 inches in height.  906.1 Fire Extinguishers o Fire extinguishers shall be placed in approved locations and may be field verified on final inspection. The fire extinguishers provided shall have a minimum rating of 2A 10 B: C.  1006.1 / 1006.2 Emergency Illumination o Emergency illumination is required to meet minimum foot candle illumination. o Emergency lighting is required. Please show locations  506.1 Knox Box o A Knox box is required to be installed on the building. o An application /order form has been attached to the review comments.  901.2 Fire Alarm System o Fire alarm system design is required to be sealed by a North Carolina Professional Engineer.  907.1.2 Fire Alarm Construction Drawings o Provide fire alarm system shop drawings. This submittal should be completed by the installing fire alarm contractor. o These plans are to be submitted before fire alarm work begins.  1008.1.10 Panic Hardware o If occupant load exceeds 50 panic hardware is required on all exit doors.  Notes o Please contact the Fire marshal’s office to schedule both fire alarm system testing and fire final inspection when work is complete. Please review the plans and adhere to any notes and alterations that were made in addition to the original designed plans. These remarks are for the plans that were submitted and its original intent. If you have any questions please do not hesitate to contact me. We look forward to working with you during the construction period. Sincerely, D. Banks Wallace Chief Deputy Fire Marshal HARNETT COUNTY CHILD CARE CENTER PLAN REVIEW APPLICATION * The application will be reviewed using 15A NCAC 18A .2800 “Rules Governing the Sanitation of Child Care Facilities.” Plans must be submitted and approved prior to construction, renovation, modification, or upon the change of ownership of such facilities. Submit plans to the Harnett County Central Permitting Office located at 108 East Front St., Lillington, NC 27546 or by mail at PO Box 65, Lillington, NC 27546. You may contact the Central Permitting Office at 910-893-7525, Ext. 2. If you have questions regarding this application, contact one of the following people listed below at 910-893-7547 Gale Violette Greene, RS Jamie Turlington, RS Food and Lodging Program Specialist Environmental Health Specialist Cindy Pierce, RS Environmental Health Specialist _____ Plans must include drawings showing placement of equipment in the facility, including storage, food service areas, diaper changing areas, can wash facilities, along with general plumbing, electrical, mechanical, and lighting plans. You must also submit equipment and finish schedules. _____ Each child care classroom should be identified by age group(s) that will be using the room. _____ Plans must have a proposed menu provided listing the foods to be served at the child care center _____ Plans must include a site plan locating exterior equipment such as dumpsters or compactors and indicating the proposed connections to approved sewer and water. In addition, please complete the following information to identify the child care facility and who to contact about questions regarding the review of this establishment: ______NEW _____REMODEL ____CONVERSION/ADDITION NAME OF CHILD CARE CENTER: _________________________________________ CHILD CARE CENTER’S ADDRESS: _________________________________________ PHONE: ______________________________ FAX: _____________________________ NAME OF OWNER: _________________________________ MAILING ADDRESS: ______________________________________________________ PHONE: ______________________________ EMAIL: ___________________________ X Rainbow Child Care Center 95 Centennial Parkway Spout Springs, NC 28326 EIG14T RCCC 213 NC-SPOUT SPRINGS LLC - Amy Labadie 1742 Crooks Road, Troy MI 48084 Amy@814cre.com(258) 519-9281 X X X X APPLICANT’S NAME: _______________________________ MAILING ADDRESS: ______________________________________________________ PHONE: ______________________________ EMAIL: ___________________________ TITLE (MANAGER, ARCHITECT, DIRECTOR): ________________________________ NUMBER OF CHILDREN FOR WHICH FACILITY WILL BE LICENSED: __________ If this is a remodel or a change of ownership, what is the age of the building? _____________ Main Food Service Meals prepared on site or catered meals? (With catered meals you are still required to have the minimum requirements in the kitchen) ______________________________________ Where will the children eat meals? (Family style, tables in classrooms, dining area, etc…) ______________________________________________________________________________ Will multi-use utensils, silverware, sippy cups, etc… be used or disposable utensils? ______________________________________________________________________________ Can the kitchen door be locked? Is there a barrier to keep children out of the kitchen? ______________________________________________________________________________ Please list all equipment to be used in the kitchen and include specification sheets: ___________ ______________________________________________________________________________ ______________________________________________________________________________ Do you have a thermometer available to monitor food temperatures? ______________ Do you have thermometers in the refrigerators? __________________ Will leftovers be served? ______ Will meals be prepared 12 or more hours in advance? _______ Infant Food Service Will bottles be stored, prepared, warmed, served, etc… in the infant room or in the kitchen? ______________________________________________________________________________ Describe your procedures for handling breast milk: ____________________________________ ______________________________________________________________________________ ______________________________________________________________________________ Does the infant room have countertop space for warming bottles? ________________________ What method will be used to warm bottles? _________________________________________ Alexia Taylor 604 Courtland Street STE 100 (407) 645-5008 ataylor@interplanllc.com Permit Coordinator 150 N/A Meals Prepared on-site Family Style in classrooms Both will be used Yes and yes Refrigeration equipment, cooking equipment, at least 2-compartment sink, drainboards, adequate countertop space, seperate hand wash lavatory. Infant room Yes Bottle warmers Is there a refrigerator for bottle storage? __________ Is there a thermometer? _______________ Is there a separate sink used exclusively for bottle/food preparation? ______________________ Diaper Changing Are diaper changing stations in each age appropriate room? _____________________________ Where will diaper changing supplies be kept? ________________________________________ Is there a dirty diaper receptacle with a lid? __________________________________________ Can the caregiver view the children while changing diapers? _____________________________ Where and how will soapy water, sanitizers and disinfectants be stored? ______________________________________________________________________________ ______________________________________________________________________________ Is there a separate hand wash lavatory used exclusively for diaper changing hand washing? _____________________________________________________________________________ Are diaper changing signs provided? _______________________________________________ Cubbies and Storage How and where will cubbies be arranged? ___________________________________________ _____________________________________________________________________________ Are coat hooks spaced at least 12” apart? ____________________________________________ Is all storage in all closets stored off floor (recommend 12”) to facilitate cleaning? ___________ Will toothbrushes be used at the center? _________ Will they be labeled? ______________ Beds, Cots, Mats, Cribs, and Linens Will cribs have the capability of being spaced 18” apart while in use? (if not, crib dividers and partitions are acceptable) ______________________________________________________ How and where will cots and/or mats be stored? _____________________________________ Where will crib, cot, and mat sheets be stored? ______________________________________ Where is there a designated sick area with cot/mat? ___________________________________ Is linen being provided by the center or the parents? ___________________________________ How often will infant sheets be changed? ___________________________________________ How often will sheets be laundered? _______________________________________________ Yes Yes Yes On the diaper changing stations in cabinets out of children's reach Yes Locked in upper cabinets Yes Mounted to walls, near entrance doors to classroom Yes Yes In the classroom where a designated cot storage area is made for the purpose Center will have a washer and dryer and clean items will be stored in the cabiners inside the classrooms. In the Director's office Cleaning, Sanitizing and Disinfecting Is all furniture in the center of a smooth, washable finish? _______________________________ How will toys in infant and toddler rooms be washed and sanitized? Where? How often? ______________________________________________________________________________ ______________________________________________________________________________ Please explain what type of sanitizer will be used to sanitize toys, food areas, furniture, etc.: ______________________________________________________________________________ Please explain what type of disinfectant will be used to sanitize toilets, lavatories and diaper changing tables: _______________________________________________________________ Do you have appropriate test strips for the types of sanitizer and disinfectant you are using? _________________________________ Where is the can wash facility for cleaning trash cans, dumping mop water, etc…? ______________________________________________________________________________ Will water play centers be used? ____________________ Hand wash lavatories Does each toilet area have a hand wash lavatory? ______________________________________ Does the diaper changing station have a hand wash lavatory exclusively for diaper changing? ______________________________________________________________________________ Does the food service area in the infant and toddler room have a lavatory exclusively for food service? ______________________________________________________________________ Does the kitchen have a hand sink that is separate from the 2 or 3 compartment sink for hand washing only? _________________________________________________________________ What types of faucets are at all hand wash lavatories (please note that metering type is not allowed unless they can retain warm water for at least 20 seconds at the first pressing): ______________________________________________________________________________ Are handwashing signs provided? ________________________________ Locked Items Please indicate where the following type of locked items will be stored and what type of lock: Medicines (both refrigerated and non refrigerated) ______________________________________________________________________________ Yes Daily toys will be washed using 3 step process (soapy-clean-let air dry) mouthed toys are put in a bucket and washed using the 3 step process (soapy-clean-let air dry). 3 step process (wash, clean water rinse, bleach water) bleach water is 50 to 200 parts per Chlorine. Yes Laundry room - Utility mop sink Yes Yes Yes Yes Chicago # 1017 Faucet In lock boxes in kitchen (refrigerated medicines) and in lock boxes in management office (non-refrigerated) Cleaning supplies and all types of chemicals ______________________________________________________________________________ Personal belongings (purses, keys, employee items) ______________________________________________________________________________ Aerosols and all other toxic products ______________________________________________________________________________ Mildly Ill Children Will you be licensed to care for mildly ill children pursuant to 10A NCAC 09 .2400? _________ Please include your protocols for this type of care. Water Supply Is the child care center on a well or provided with county water? _________________________ Sewage Disposal Is disposal through an onsite septic system or county sewer? _____________________ Grease trap provided? ________________ Hot Water Supply The kitchen hot water temperature will need to be a minimum of 120 degrees Fahrenheit. All other sinks that are accessible to children and the can wash facility must be maintained between 80-110’Fahrenheit. Using two separate water heaters may be the best option since it is often difficult to obtain two separate temperatures with one water heater. Mixing valves installed on sinks have a high failure rate and are not very dependable. Explain what the specifications of your water heater(s) are. (For example, if you are using two water heaters, indicate which one is for the kitchen and which one if for the classrooms). It is recommended that the minimum water heater size be 50 gallons. Tank Manufacturer and Model # ___________________________________________________ Storage tank size__________ GPH recovery__________ Additional tank size___________ Lighting Do all light fixtures have shatterproof or shielded bulbs? ________________________________ Will lighting illuminate 50 ft. candles at all work areas? ________________________________ and 10 ft. candles at all other areas, including storage closets? ___________________________ Finishes Please describe the finishes/construction material in the following areas: County Water County Sewer No No aerosol dispenser. All placed in storage room outside of the kitchen, the door stays locked at all times. All placed in upper cabinets, which are locked. All placed in upper cabinets, which are locked. Floors Walls Baseboards Ceilings Kitchen Bathrooms Infant Room Toddler Room Other Rooms Staff Room/Office Storeroom Other *Wall to wall carpets must be cleaned at least every six months Animals What type of animals will be on the premises? ________________________________________ Outside premises Please describe the playground area (size, type of play equipment, type of fence, water activities, etc…) ________________________________________________________________________ _____________________________________________________________________________ Is there chromated copper arsenate (CCA) pressure-treated wood in the play ground area? _____________________________________________________________________________ What methods will you use to make this inaccessible to the children? ______________________ ______________________________________________________________________________ Is the can wash facility located outside? _____________________________________________ If yes, is there a fence and lock around it so it is not accessible to children? _________________ Is the HVAC, mechanical equipment, etc… locked with a fence around it so it is not accessible to children? ___________________________________________________________________ Attach additional sheets if necessary. gg 8/06 Vinyl Composit Tile Vinyl Composit TileDrywall Drywall Diaper Changing Counters:Plastic Laminate Sheet Vinyl Sheet Vinyl Drywall Backsplash: Plastic Laminate Backsplash: Plastic Laminate Cabinetry: Thermofoil Drywall Drywall Drywall Drywall Drywall Size is approx. 10,000 sq feet; Fences - commerical grade/chain link; Playground surface is turf & pour & play; Equipment - Inf. Tod - Inf. maze & fun umbrella (for shade); YPSTPS - Climbing unit & fun umbrella; Ball drop hoop; Pk - school-age - climbing unit & fun umbrella No N/A Yes, there will be a fence around the unit(s) that have a locking mechanism and it will not be accessible to children. Project Title: Rainbow Child Care Center Report date: 04/23/18 Data filename: P:\R\RainbowChildCare\2017.0643 - 95 Centennial Parkway, Spout Springs, NC\4 Support Documents\5 Calculations\2 Energy and Load Calcs\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC Bldg. Envelope Only.cck Page 1 of 2 COMcheck Software Version 4.0.8.1 Envelope Compliance Certificate Section 1: Project Information Energy Code: 2012 North Carolina Energy Conservation Code Project Title: Rainbow Child Care Center Project Type: New Construction Construction Site:Owner/Agent:Designer/Contractor: 95 Centennial Parkway Cameron, NC 28326 Amy Labadie 814 Development, LLC 3221 W. Big Beaver Suite 111 Troy, MI 48084 Louise Craver Interplan, LLC 604 Courtland Street Orlando, FL 32804 407.645.5008 LCraver@interplanllc.com Building Location (for weather data):Cameron, North Carolina Climate Zone:3a Vertical Glazing / Wall Area Pct.:22% Building Use: Area Type Floor Area 1-Corporate Office (School/University) : Nonresidential 11992 Section 2: Envelope Assemblies and Requirements Checklist Envelope PASSES: Design 5% better than code. Envelope Assemblies: Component Name/Description Gross Area or Perimeter Cavity R-Value Cont. R-Value Proposed U-Factor Budget U-Factor(a) Orientation: NORTH Right Wall: Wood-Framed, 16" o.c., [Bldg. Use 1 - Corporate Office]1381 21.0 0.0 0.062 0.064 Fixed windows (7): Vinyl/Fiberglass Frame:Fixed, Perf. Specs.: Product ID Windgate picture, SHGC 0.30, PF 0.04, VT 0.57, [Bldg. Use 1 - Corporate Office] (b) 56 ------0.270 0.320 Windows (7): Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID Windgate Single hung, SHGC 0.29, PF 0.04, VT 0.56, [Bldg. Use 1 - Corporate Office] (b) 175 ------0.270 0.320 Service door: Insulated Metal, Swinging, [Bldg. Use 1 - Corporate Office] 20 ------0.600 0.700 Doors (4): Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID unknown, SHGC 0.40, PF 0.04, VT 0.80, [Bldg. Use 1 - Corporate Office] (b) 80 ------0.650 0.450 Orientation: EAST Front Wall: Wood-Framed, 16" o.c., [Bldg. Use 1 - Corporate Office]993 21.0 0.0 0.062 0.064 Fixed Windows (10): Vinyl/Fiberglass Frame:Fixed, Perf. Specs.: Product ID windgate picture window, SHGC 0.30, PF 0.04, VT 0.57, [Bldg. Use 1 - Corporate Office] (b) 87 ------0.270 0.320 Windows (7): Vinyl/Fiberglass Frame:Fixed, Perf. Specs.: Product ID windgate picture window, SHGC 0.29, PF 0.04, VT 0.56, [Bldg. Use 1 - Corporate Office] (b) 123 ------0.270 0.320 Outdoor entry door, transom and sidelights: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID unknown, SHGC 0.40, PF 0.04, VT 0.80, [Bldg. Use 1 - Corporate Office] (b) 66 ------0.650 0.770 Orientation: SOUTH Left Wall: Wood-Framed, 16" o.c., [Bldg. Use 1 - Corporate Office]1256 21.0 0.0 0.062 0.064 Windows (6): Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID Windgate single-hung, SHGC 0.29, PF 0.04, VT 0.56, [Bldg. Use 1 - Corporate Office] (b) 150 ------0.270 0.320 Project Title: Rainbow Child Care Center Report date: 04/23/18 Data filename: P:\R\RainbowChildCare\2017.0643 - 95 Centennial Parkway, Spout Springs, NC\4 Support Documents\5 Calculations\2 Energy and Load Calcs\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC Bldg. Envelope Only.cck Page 2 of 2 Doors (4): Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID unknown, SHGC 0.40, PF 0.04, VT 0.80, [Bldg. Use 1 - Corporate Office] (b) 80 ------0.650 0.450 Orientation: WEST Rear Wall: Wood-Framed, 16" o.c., [Bldg. Use 1 - Corporate Office]728 21.0 0.0 0.062 0.064 Windows (2): Vinyl/Fiberglass Frame:Operable, Perf. Specs.: Product ID Windgate single hung, SHGC 0.29, PF 0.04, VT 0.56, [Bldg. Use 1 - Corporate Office] (b) 50 ------0.270 0.320 Doors (5): Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID unkown, SHGC 0.40, PF 0.04, VT 0.80, [Bldg. Use 1 - Corporate Office] (b) 100 ------0.650 0.450 Orientation: UNSPECIFIED ORIENTATION Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Corporate Office]12000 38.0 0.0 0.027 0.027 Floor 1: Slab-On-Grade:Unheated, Vertical 4 ft., [Bldg. Use 1 - Corporate Office] 491 ---10.0 ------ (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. Air Leakage, Component Certification, and Vapor Retarder Requirements: q 1.All joints and penetrations are caulked, gasketed or covered with a moisture vapor-permeable wrapping material installed in accordance with the manufacturer's installation instructions. q 2.Windows, doors, and skylights certified as meeting leakage requirements. q 3.Component R-values & U-factors labeled as certified. q 4.No roof insulation is installed on a suspended ceiling with removable ceiling panels. q 5.'Other' components have supporting documentation for proposed U-Factors. q 6.Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. q 7.Shaft vents serving stairs and elevators integral to the building envelope are equipped with motorized dampers. Exceptions: q Buildings without fire alarm system. q Stairway vents open to the exterior. q 8.Cargo doors and loading dock doors are weather sealed. q 9.Recessed lighting fixtures installed in the building envelope are Type IC rated as meeting ASTM E283, are sealed with gasket or caulk. q 10.Building entrance doors have a vestibule equipped with self-closing devices. Exceptions: q Building entrances with revolving doors. q Doors not intended to be used as a building entrance. q Doors that open directly from a space less than 3000 sq. ft. in area. q Doors used primarily to facilitate vehicular movement or materials handling and adjacent personnel doors. q Doors opening directly from a sleeping/dwelling unit. q Buildings less than four stories above grade and less than 10,000 ft2 in area. Additional Efficiency Package Requirements: q 1.The high efficiency HVAC option has been selected as the additional efficiency package required by this energy code. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Section 3: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2012 North Carolina Energy Conservation Code requirements in COMcheck Version 4.0.8.1 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Project Title: Rainbow Child Care Center Report date: 04/18/18 Data filename: G:\MEP\06 MECHANICAL DESIGN\HVAC Energy Calcs\Rainbow Child Care Center\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC.cck Page 3 of 11 COMcheck Software Version 4.0.8.1 Interior Lighting Compliance Certificate Section 1: Project Information Energy Code: 2012 North Carolina Energy Conservation Code Project Title: Rainbow Child Care Center Project Type: New Construction Construction Site:Owner/Agent:Designer/Contractor: 95 Centennial Parkway Cameron, NC 28326 Amy Labadie 814 Developments, LLC 3221 W. Big Beaver Suite 111 Troy, MI 48084 Stacy Henson Interplan, LCC 604 Courtland Street Orlando, FL 32804 407.645.5008 shenson@interplanllc.com Section 2: Interior Lighting and Power Calculation A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B x C) Vestibule (Common Space Types:Corridor/Transition)69 0.65 45 Lobby (Common Space Types:Lobby)207 0.6 124 Reception (Common Space Types:Education Laboratory)255 1.28 326 Director's Office (Office:Enclosed)138 1.11 153 Hallway (Common Space Types:Corridor/Transition)112 0.65 73 Kitchen (Common Space Types:Food Preparation)250 0.99 248 Conference Room (Common Space Types:Conference/Meeting/Multipurpose)74 1.29 95 Infant 1/2 (Common Space Types:Education Laboratory)1123 1.28 1437 Young Pre-School (Common Space Types:Education Laboratory)580 1.28 742 Varsity (Common Space Types:Education Laboratory)910 1.28 1165 Pre-School 1/2 (Common Space Types:Education Laboratory)1301 1.28 1665 Pre-K 1/2 (Common Space Types:Education Laboratory)1392 1.28 1782 Toddler 1/2 (Common Space Types:Education Laboratory)1329 1.28 1701 Gym (Gymnasium:Playing Area)910 1.35 1229 Corridor 1/Central Corridor (Common Space Types:Corridor/Transition)1143 0.65 743 Laundry (Common Space Types:Education Laboratory)68 1.28 87 Stairs (Common Space Types:Stairway)59 0.69 41 Storage/Pantry/Utility/Closet/Gym Equipment/IT Closet (Common Space Types:Active Storage) 559 0.63 352 Staff Lounge (Common Space Types:Conference/Meeting/Multipurpose)89 1.29 115 Restrooms (Common Space Types:Restroom)669 0.84 562 Total Allowed Watts =12685 Section 3: Interior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) Vestibule ( Common Space Types:Corridor/Transition 69 sq.ft.) Linear Fluorescent 1: E: Other: Electronic:1 2 54 108 Linear Fluorescent 2: K: Other: Electronic:3 1 54 54 Lobby ( Common Space Types:Lobby 207 sq.ft.) Linear Fluorescent 3: B: 48" T8 32W: Electronic:2 4 64 256 Reception ( Common Space Types:Education Laboratory 255 sq.ft.) Linear Fluorescent 3 copy 1: B: 48" T8 32W: Electronic:2 4 64 256 Project Title: Rainbow Child Care Center Report date: 04/18/18 Data filename: G:\MEP\06 MECHANICAL DESIGN\HVAC Energy Calcs\Rainbow Child Care Center\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC.cck Page 4 of 11 Compact Fluorescent 1: J: Triple 4-pin 18W: Electronic:1 3 18 54 Director's Office ( Office:Enclosed 138 sq.ft.) Linear Fluorescent 5: A: 48" T8 32W: Electronic:3 2 87 174 Hallway ( Common Space Types:Corridor/Transition 112 sq.ft.) Linear Fluorescent 3 copy 1: B: 48" T8 32W: Electronic:2 2 64 128 Kitchen ( Common Space Types:Food Preparation 250 sq.ft.) Linear Fluorescent 5 copy 1: A: 48" T8 32W: Electronic:3 3 87 261 Conference Room ( Common Space Types:Conference/Meeting/Multipurpose 74 sq.ft.) Linear Fluorescent 5 copy 2: A: 48" T8 32W: Electronic:3 1 87 87 Infant 1/2 ( Common Space Types:Education Laboratory 1123 sq.ft.) Linear Fluorescent 5 copy 3: A: 48" T8 32W: Electronic:3 12 87 1044 Linear Fluorescent 11: H: 36" T8 25W: Electronic:2 2 25 50 Young Pre-School ( Common Space Types:Education Laboratory 580 sq.ft.) Linear Fluorescent 5 copy 4: A: 48" T8 32W: Electronic:3 7 87 609 Varsity ( Common Space Types:Education Laboratory 910 sq.ft.) Linear Fluorescent 5 copy 5: A: 48" T8 32W: Electronic:3 10 87 870 Pre-School 1/2 ( Common Space Types:Education Laboratory 1301 sq.ft.) Linear Fluorescent 5 copy 6: A: 48" T8 32W: Electronic:3 20 87 1740 Pre-K 1/2 ( Common Space Types:Education Laboratory 1392 sq.ft.) Linear Fluorescent 5 copy 7: A: 48" T8 32W: Electronic:3 18 87 1566 Toddler 1/2 ( Common Space Types:Education Laboratory 1329 sq.ft.) Linear Fluorescent 5 copy 8: A: 48" T8 32W: Electronic:3 16 87 1392 Linear Fluorescent 11 copy 1: H: 36" T8 25W: Electronic:2 2 25 50 Gym ( Gymnasium:Playing Area 910 sq.ft.) Linear Fluorescent 18: C: 48" T8 32W: Electronic:4 8 128 1024 Corridor 1/Central Corridor ( Common Space Types:Corridor/Transition 1143 sq.ft.) Linear Fluorescent 3 copy 2: B: 48" T8 32W: Electronic:2 13 64 832 Laundry ( Common Space Types:Education Laboratory 68 sq.ft.) Linear Fluorescent 3 copy 3: B: 48" T8 32W: Electronic:2 1 64 64 Stairs ( Common Space Types:Stairway 59 sq.ft.) Linear Fluorescent 21: D: 48" T8 32W: Electronic:2 1 64 64 Storage/Pantry/Utility/Closet/Gym Equipment/IT Closet ( Common Space Types:Active Storage 559 sq.ft.) Linear Fluorescent 21 copy 1: D: 48" T8 32W: Electronic:2 7 64 448 Linear Fluorescent 18 copy 1: C: 48" T8 32W: Electronic:4 1 128 128 Staff Lounge ( Common Space Types:Conference/Meeting/Multipurpose 89 sq.ft.) Linear Fluorescent 5 copy 3: A: 48" T8 32W: Electronic:3 1 87 87 Restrooms ( Common Space Types:Restroom 669 sq.ft.) Linear Fluorescent 3 copy 3: B: 48" T8 32W: Electronic:2 10 64 640 Total Proposed Watts =11986 Section 4: Requirements Checklist Interior Lighting PASSES: Design 6% better than code. Lighting Wattage: q 1.Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 12685 11986 YES Controls, Switching, and Wiring: q 2.Separate lighting controls present for: Display/Accent Lighting, Case Lighting, lighting for nonvisual applications (e.g., such as plant growth and food warming), lighting equipment that is for sale or for demonstrations in lighting education. q 3.Hotel and motel guest rooms and guest suites have a master control device at the main room entry that controls all permanently installed luminaires and switched receptacles. q 4.Supplemental task lighting has a control device integral to the luminaires or be controlled by a wall-mounted control device provided the control device is readily accessible and located so that the occupant can see the controlled lighting.. q 5.Independent controls for each space (switch/occupancy sensor). Exceptions: q Areas designated as security or emergency areas that must be continuously illuminated. Project Title: Rainbow Child Care Center Report date: 04/18/18 Data filename: G:\MEP\06 MECHANICAL DESIGN\HVAC Energy Calcs\Rainbow Child Care Center\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC.cck Page 5 of 11 q Lighting in stairways or corridors that are elements of the means of egress. q 6.Individual dwelling units separately metered. q 7.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. q 8.Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either controlling all luminaires, dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps, switching the middle lamp luminaires independently of other lamps, or switching each luminaire or each lamp. Exceptions: q Only one luminaire in space. q An occupant-sensing device controls the area. q The area is a corridor, storeroom, restroom, public lobby or sleeping unit. q Areas that use less than 0.6 Watts/sq.ft. q 9.Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: q Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security. q 10.Photocell/astronomical time switch on exterior lights. Exceptions: q Lighting intended for 24 hour use. q 11.Tandem wired one-lamp and three-lamp ballasted luminaires (No single-lamp ballasts). Exceptions: q Electronic high-frequency ballasts; Luminaires on emergency circuits or with no available pair. q 12.Lighting controls are tested to ensure that control devices, components, equipment, and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2012 North Carolina Energy Conservation Code requirements in COMcheck Version 4.0.8.1 and to comply with the mandatory requirements in the Requirements Checklist. Stacy Henson Name - Title Signature Date Project Title: Rainbow Child Care Center Report date: 04/18/18 Data filename: G:\MEP\06 MECHANICAL DESIGN\HVAC Energy Calcs\Rainbow Child Care Center\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC.cck Page 6 of 11 COMcheck Software Version 4.0.8.1 Exterior Lighting Compliance Certificate Section 1: Project Information Energy Code: 2012 North Carolina Energy Conservation Code Project Title: Rainbow Child Care Center Project Type: New Construction Exterior Lighting Zone: 2 (Neighborhood business district) Construction Site:Owner/Agent:Designer/Contractor: 95 Centennial Parkway Cameron, NC 28326 Amy Labadie 814 Developments, LLC 3221 W. Big Beaver Suite 111 Troy, MI 48084 Stacy Henson Interplan, LCC 604 Courtland Street Orlando, FL 32804 407.645.5008 shenson@interplanllc.com Section 2: Exterior Lighting Area/Surface Power Calculation A Exterior Area/Surface B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B x C) F Proposed Watts Front Door (Main entry)16 ft of door width 20 Yes 320 52 Building Facade (Illuminated length of facade wall or surface) 467 ft 2.5 No 1168 840 Total Tradable Watts* =320 52 Total Allowed Watts =1488 Total Allowed Supplemental Watts** =600 * Wattage tradeoffs are only allowed between tradable areas/surfaces. ** A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Section 3: Exterior Lighting Fixture Schedule A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures D Fixture Watt. E (C X D) Front Door ( Main entry 16 ft of door width): Tradable Wattage Compact Fluorescent 1: Twin Tube 13W: Electronic:2 2 26 52 Building Facade ( Illuminated length of facade wall or surface 467 ft): Non-tradable Wattage Compact Fluorescent 2: Triple 4-pin 42W: Electronic:1 20 42 840 Total Tradable Proposed Watts =52 Section 4: Requirements Checklist Lighting Wattage: q 1.Within each non-tradable area/surface, total proposed watts must be less than or equal to total allowed watts. Across all tradable areas/surfaces, total proposed watts must be less than or equal to total allowed watts. Compliance:Passes. Controls, Switching, and Wiring: q 2.All exemption claims are associated with fixtures that have a control device independent of the control of the nonexempt lighting. q 3.Lighting not designated for dusk-to-dawn operation is controlled by either a a photosensor (with time switch), or an astronomical time switch. q 4.Lighting designated for dusk-to-dawn operation is controlled by an astronomical time switch or photosensor. Project Title: Rainbow Child Care Center Report date: 04/18/18 Data filename: G:\MEP\06 MECHANICAL DESIGN\HVAC Energy Calcs\Rainbow Child Care Center\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC.cck Page 7 of 11 q 5.All time switches are capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. q 6.Lighting controls are tested to ensure that control devices, components, equipment, and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. Exterior Lighting Efficacy and Application: q 7.All exterior building grounds luminaires that operate at greater than 100W have minimum efficacy of 60 lumen/watt. Exceptions: q Lighting that has been claimed as exempt and is identified as such in Section 3 table above. q Lighting that is specifically designated as required by a health or life safety statue, ordinance, or regulation. q Emergency lighting that is automatically off during normal building operation. q Lighting that is controlled by motion sensor. q 8.Exterior lighting fixtures are fully shielded fixtures unless a lighting plan is submitted showing that the use of alternative fixtures would provide greater energy efficiency. Exceptions: q Luminaires with an output of 150 Watts or less, or the equivalent light output. q Luminaires intended to illuminate the facade of buildings or to illuminate other objects including but not limited to flagpoles, landscape and water features, statuary and works of art. q Luminaires for historic lighting on the premises of an historic building as defined in the or within a designated historic district. q Outdoor sports facility lighting of the participant sport area. q Emergency exit discharge lighting. q Sign illumination, festoon lighting, low voltage landscape lighting. q Temporary lighting for emergency, repair, construction, special events or similar activities. Section 5: Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2012 North Carolina Energy Conservation Code requirements in COMcheck Version 4.0.8.1 and to comply with the mandatory requirements in the Requirements Checklist. Stacy Henson Name - Title Signature Date Project Title: Rainbow Child Care Center Report date: 04/18/18 Data filename: G:\MEP\06 MECHANICAL DESIGN\HVAC Energy Calcs\Rainbow Child Care Center\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC.cck Page 8 of 11 COMcheck Software Version 4.0.8.1 Mechanical Compliance Certificate Section 1: Project Information Energy Code: 2012 North Carolina Energy Conservation Code Project Title: Rainbow Child Care Center Project Type: New Construction Construction Site:Owner/Agent:Designer/Contractor: 95 Centennial Parkway Cameron, NC 28326 Amy Labadie 814 Developments, LLC 3221 W. Big Beaver Suite 111 Troy, MI 48084 Stacy Henson Interplan, LCC 604 Courtland Street Orlando, FL 32804 407.645.5008 shenson@interplanllc.com Section 2: General Information Building Location (for weather data):Cameron, North Carolina Climate Zone:3a Section 3: Mechanical Systems List Quantity System Type & Description 1 GF-1 (Single Zone) : Heating: 1 each - Central Furnace, Gas, Capacity = 126 kBtu/h Proposed Efficiency = 95.00% Et, Required Efficiency = 92.00% Et Cooling: 1 each - Split System, Capacity = 57 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 15.00 SEER, Required Efficiency: 15.00 SEER + 12.5 EER Fan System: None 1 GF-2 (Single Zone) : Heating: 1 each - Central Furnace, Gas, Capacity = 126 kBtu/h Proposed Efficiency = 95.00% Et, Required Efficiency = 92.00% Et Cooling: 1 each - Split System, Capacity = 57 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 15.00 SEER, Required Efficiency: 15.00 SEER + 12.5 EER Fan System: None 1 GF-3 (Single Zone) : Heating: 1 each - Central Furnace, Gas, Capacity = 126 kBtu/h Proposed Efficiency = 95.00% Et, Required Efficiency = 92.00% Et Cooling: 1 each - Split System, Capacity = 57 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 15.00 SEER, Required Efficiency: 15.00 SEER + 12.5 EER Fan System: None 1 GF-4 (Single Zone) : Heating: 1 each - Central Furnace, Gas, Capacity = 126 kBtu/h Proposed Efficiency = 95.00% Et, Required Efficiency = 92.00% Et Cooling: 1 each - Split System, Capacity = 57 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 15.00 SEER, Required Efficiency: 15.00 SEER + 12.5 EER Fan System: None 1 GF-5 (Single Zone) : Heating: 1 each - Central Furnace, Gas, Capacity = 126 kBtu/h Proposed Efficiency = 95.00% Et, Required Efficiency = 92.00% Et Cooling: 1 each - Split System, Capacity = 57 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 15.00 SEER, Required Efficiency: 15.00 SEER + 12.5 EER Fan System: None 1 GF-6 (Single Zone) : Heating: 1 each - Central Furnace, Gas, Capacity = 126 kBtu/h Proposed Efficiency = 95.00% Et, Required Efficiency = 92.00% Et Project Title: Rainbow Child Care Center Report date: 04/18/18 Data filename: G:\MEP\06 MECHANICAL DESIGN\HVAC Energy Calcs\Rainbow Child Care Center\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC.cck Page 9 of 11 Cooling: 1 each - Split System, Capacity = 57 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 15.00 SEER, Required Efficiency: 15.00 SEER + 12.5 EER Fan System: None 1 GF-7 (Single Zone) : Heating: 1 each - Central Furnace, Gas, Capacity = 126 kBtu/h Proposed Efficiency = 95.00% Et, Required Efficiency = 92.00% Et Cooling: 1 each - Split System, Capacity = 57 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: None Proposed Efficiency = 15.00 SEER, Required Efficiency: 15.00 SEER + 12.5 EER Fan System: None 1 Water Heater 1: Gas Storage Water Heater, Capacity: 100 gallons, Input Rating: 120 kBtu/h w/ Circulation Pump Proposed Efficiency: 90.00 % Et, Required Efficiency: 80.00 % Et Section 4: Requirements Checklist Additional Efficiency Package Requirements: q 1.The high efficiency HVAC option has been selected as the additional efficiency package required by this energy code. Systems not satisfying the performance requirement are identified in the specific system requirement section below. Full compliance with this efficiency option requires inspection and verification that each system meets the required performance criteria. Requirements Specific To: GF-1 : q 1.Equipment minimum efficiency: Central Furnace (Gas): 92.00 % Et (or 92% AFUE) q 2.Equipment minimum efficiency: Split System: 15.00 SEER + 12.5 EER Requirements Specific To: GF-2 : q 1.Equipment minimum efficiency: Central Furnace (Gas): 92.00 % Et (or 92% AFUE) q 2.Equipment minimum efficiency: Split System: 15.00 SEER + 12.5 EER Requirements Specific To: GF-3 : q 1.Equipment minimum efficiency: Central Furnace (Gas): 92.00 % Et (or 92% AFUE) q 2.Equipment minimum efficiency: Split System: 15.00 SEER + 12.5 EER Requirements Specific To: GF-4 : q 1.Equipment minimum efficiency: Central Furnace (Gas): 92.00 % Et (or 92% AFUE) q 2.Equipment minimum efficiency: Split System: 15.00 SEER + 12.5 EER Requirements Specific To: GF-5 : q 1.Equipment minimum efficiency: Central Furnace (Gas): 92.00 % Et (or 92% AFUE) q 2.Equipment minimum efficiency: Split System: 15.00 SEER + 12.5 EER Requirements Specific To: GF-6 : q 1.Equipment minimum efficiency: Central Furnace (Gas): 92.00 % Et (or 92% AFUE) q 2.Equipment minimum efficiency: Split System: 15.00 SEER + 12.5 EER Requirements Specific To: GF-7 : q 1.Equipment minimum efficiency: Central Furnace (Gas): 92.00 % Et (or 92% AFUE) q 2.Equipment minimum efficiency: Split System: 15.00 SEER + 12.5 EER Requirements Specific To: Water Heater 1 : q 1.Water heating equipment meets minimum efficiency requirements: Gas Storage Water Heater efficiency: 80.00 % Et (161 SL, kBtu/h) q 2.All piping in circulating system insulated q 3.Hot water storage temperature controls that allow setpoint of 90°F for non-dwelling units and 110°F for dwelling units. q 4.Automatic time control of heat tapes and recirculating systems present q 5.Controls will shut off operation of circulating pump between water heater/boiler and storage tanks within 5 minutes after end of heating cycle Generic Requirements: Must be met by all systems to which the requirement is applicable: q 1.Plant equipment and system capacity no greater than needed to meet loads Exception(s): q Standby equipment automatically off when primary system is operating q Multiple units controlled to sequence operation as a function of load q 2.Minimum one temperature control device per system q 3.Minimum one humidity control device per installed humidification/dehumidification system Project Title: Rainbow Child Care Center Report date: 04/18/18 Data filename: G:\MEP\06 MECHANICAL DESIGN\HVAC Energy Calcs\Rainbow Child Care Center\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC.cck Page 10 of 11 q 4.Load calculations per ASHRAE/ACCA Standard 183. q 5.Automatic Controls: Setback to 55°F (heat) and 85°F (cool); 7-day clock, 2-hour occupant override, 10-hour backup Exception(s): q Continuously operating zones q 6.Outside-air source for ventilation; system capable of reducing OSA to required minimum q 7.R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly Exception(s): q Ducts located within equipment q Ducts with interior and exterior temperature difference not exceeding 15°F. q 8.Mechanical fasteners and sealants used to connect ducts and air distribution equipment q 9.Ducts sealed - longitudinal seams on rigid ducts; transverse seams on all ducts; UL 181A or 181B tapes and mastics q 10.Hot water pipe insulation: 1.5 in. for pipes <=1.5 in. and 2 in. for pipes >1.5 in. Chilled water/refrigerant/brine pipe insulation: 1.5 in. for pipes <=1.5 in. and 1.5 in. for pipes >1.5 in. Steam pipe insulation: 1.5 in. for pipes <=1.5 in. and 3 in. for pipes >1.5 in. Exception(s): q Piping within HVAC equipment. q Fluid temperatures between 55 and 105°F. q Fluid not heated or cooled with renewable energy. q Piping within room fan-coil (with AHRI440 rating) and unit ventilators (with AHRI840 rating). q Runouts <4 ft in length. q 11.Operation and maintenance manual provided to building owner q 12.Thermostatic controls have 5°F deadband Exception(s): q Thermostats requiring manual changeover between heating and cooling q Special occupancy or special applications where wide temperature ranges are not acceptable and are approved by the authority having jurisdiction. q 13.Balancing devices provided in accordance with IMC 603.17 q 14.Ventilation systems in buildings over 10,000 ft2 of conditioned area have demand controls. DCV systems are capable of reducing outside supply air to at least 50% below design ventilation rates. In all buildings, spaces larger than 500 ft2 with a maximum occupant load of 40 or more people per 1,000 ft2 of floor area control ventilation supply air flow by monitoring indoor air quality conditions. Exception(s): q Systems with heat recovery. q Building spaces where the primary ventilation needs are for process loads, including laboratories and hospital. q Individual units with less than 65 kBtu/h of cooling capacity. q 15.Motorized, automatic shutoff dampers required on exhaust and outdoor air supply openings Exception(s): q Gravity dampers acceptable in buildings <3 stories q 16.Automatic controls for freeze protection systems present q 17.Exhaust air heat recovery included for systems 5,000 cfm or greater with more than 70% outside air fraction or specifically exempted Exception(s): q Hazardous exhaust systems, commercial kitchen and clothes dryer exhaust systems that the International Mechanical Code prohibits the use of energy recovery systems. q Systems serving spaces that are heated and not cooled to less than 60°F. q Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. q Heating systems in climates with less than 3600 HDD. q Cooling systems in climates with a 1 percent cooling design wet-bulb temperature less than 64°F. q Systems requiring dehumidification that employ energy recovery in series with the cooling coil. q Laboratory fume hood exhaust systems that have either a variable air volume system capable of reducing exhaust and makeup air volume to 50 percent or less of design values or, a separate make up air supply meeting the following makeup air requirements: a) at least 75 percent of exhaust flow rate, b) heated to no more than 2°F below room setpoint temperature, c) cooled to no lower than 3°F above room setpoint temperature, d) no humidification added, e) no simultaneous heating and cooling. Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2012 North Project Title: Rainbow Child Care Center Report date: 04/18/18 Data filename: G:\MEP\06 MECHANICAL DESIGN\HVAC Energy Calcs\Rainbow Child Care Center\17.0643 Rainbow Child Care Cameron, NC - 2012 NCECC.cck Page 11 of 11 Carolina Energy Conservation Code requirements in COMcheck Version 4.0.8.1 and to comply with the mandatory requirements in the Requirements Checklist. Stacy Henson Name - Title Signature Date Section 6: Post Construction Compliance Statement q HVAC record drawings of the actual installation, system capacities, calibration information, and performance data for each equipment provided to the owner. q HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor. q Written HVAC balancing and operations report provided to the owner. The above post construction requirements have been completed. Principal Mechanical Designer-Name Signature Date 04/20/18 T.100 COVER SHEET JCRCCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT Rainbow Child Care Center Code InformationInterior Finish Flame FROM TABLE 803.5 (GROUP E) 1. EXIT ENCLOSURES AND EXIT PASSAGEWAYS: CLASS A, FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450 2. CORRIDORS: CLASS B, FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450 3. ROOMS AND ENCLOSED SPACES: CLASS C, FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450 Building Code Note: Deferred Submittal Note: Type of Construction Type V-B, Unsprinklered Building Occupancy E (Educational) Per Sections 305.2 & 308.5.2 Exception. Occupant Loads 1. Per Building Code Table 1004.1.1 Maximum Floor Area Allowances per Occupant Daycare: 35 net sq. ft. / occupant Classrooms: 6,303 s.f. / 35 = 180 Exercise (Gym): 943 s.f. / 50 = 19 Business (Office/Reception)= 240 s.f. /100 = 3 Kitchen: 253 s.f. / 200 = 2 Maximum Occupant Load for Egress = 204 2. Actual Occupant Load (Maximum operational occupancy per state of North Carolina Childcare licensing) Refer to Sheet A.102 for complete Licensing Chart. Children: 149 children Director, Teachers, Staff: 23 occupants Total Number of Occupants:172 occupants Height and Area Limitations for E: Maximum Height:1 Story (40'-0") Proposed Height: 1 Story 25'-6 3/4" Building Area:9,500 s.f. Building Area Modifications: Per section 506.2 (NCSBC 2012) - Frontage Increase Calculation If = (F/P - 0.25)W/30 If = 100 [491/491 - 0.25] 30/30 = 75% Increase 9,500 Sq. Ft. (.75) = 7,125 Sq. Ft. Increase 9,500 Sq. Ft. + 7,125 Sq. Ft. = 16,625 Allowable Sq. Ft. Maximum Area Allowed:16,625 Sq. Ft. Total Building Gross Area:11,992 Sq. Ft. First Floor Gross Area:11,992 Sq. Ft. Equipment Platform Area *: 514 Sq. Ft. * Per Section 505.5, Equipment Platforms are excluded from the Fire Area calculation. Fire Protection: Automatic Fire Sprinkler System: NO Per Section 903.2.3, an Automatic Fire Sprinkler system is not required for Fire Areas less than 12,000 s.f. in Group E. Corridor Protection: Fire Resistance Rating is not required according to NCSBC & FPC Section 1018.1 g for Group E. Protection of Incidental Accessory Occupancies (Section 508.2.5): Laundry: no separation required (area is less than 100 s.f.) Separation of Accessory Occupancies (Section 508.2): General Closets, Gym Equipment Closets, IT Closet, Kitchen, Pantry, Utility Room, Staff Lounge & Conference Rm. Total Area of Accessories = 1,003 s.f. 10% of Total Building Area= 11,992 x .10= 1,199 s.f. 1,003s.f. < 1,199 s.f. Separation of Accessory Spaces is not required according to 508.2.3 & 508.2.4. Stair Enclosure (Section 505.5) Equipment platforms shall not be a part of any mezzanine and such platforms and the walkways, stairs, alternating tread devices and ladders providing access to an equipment platform shall not serve as a part of the means of egress from the building. ALL WORK IS TO COMPLY WITH THE BUILDING CODES MENTIONED IN THE "CODE INFORMATION" SECTION IN THIS SHEET. THE REGISTERED DESIGN PROFESSIONAL IS: LOUISE CRAVER. THESE CONSTRUCTION DOCUMENTS WERE PRODUCED FOR COMPLIANCE WITH THE CONSTRUCTION CODES IN EFFECT AT TIME OF PERMIT SUBMITTAL. ALL ENGINEERS, CONTRACTORS AND SUPPLIERS INVOLVED WITH THIS PROJECT SHALL COMPLY WITH THE SAME CODES. ISSUED AND APPROVED CODE MODIFICATIONS AND/OR BOARDS OF APPEALS RULING AND WHENEVER REQUIRED SHALL PROVIDE SHOP DRAWINGS AND SUBMITTALS CLEARLY DESCRIBING COMPLIANCE TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FOR REVIEW AND APPROVAL Sheet Index: T.100 Cover Sheet APPX-B Appendix B (NC) T.101 Fire & Life Safety Plan A.100 First Floor Wall Framing Plan A.101 First Floor Plan A.102 First Floor Key Plan A.102.1 Enlarged Floor Plans A.103 Attic Plan A.104 Roof Plan A.105 Finish Plan A.200 Exterior Elevations A.201 Exterior Elevations A.300 Building Sections A.301 Building Sections A.302 Building Sections A.302.1 Building Sections A.303 Wall Sections A.304 Wall Sections A.305 Section Details A.400 Interior Elevations A.401 Interior Elevations A.402 Interior Elevations A.500 Schedules S.000 General Structural Notes S.100 Foundation Plan S.101 Roof Framing Plan S.102 Equipment Platform Framing Plan S.200 Typical Schedules & Details S.300 Sections and Details S.301 Sections and Details M.001 Mechanical Cover Sheet M.100 Main Level Mechanical Plan M.200 Upper Level Mechanical Plan M.300 Mechanical Schedules M.400 Mechanical Details M.500 Mechanical Specifications P.001 Plumbing Cover Sheet P.002 Slab Dimension Plan P.100 Underground Piping Plan P.101 Main Level Piping Plan P.200 Upper Level Piping Plan & Riser Diagrams P.300 Plumbing Schedules P.400 Plumbing Details P.401 Plumbing Details E.000 Electrical Cover Sheet E.010 Electrical Site Plan E.100 Electrical Plan - Lighting E.101 Electrical Plan - Power E.102 Electrical Plan - Fire Alarm E.103 Electrical Plan - Equipment Platform E.201 Electrical Details E.202 Panel Schedules E.204 Electrical Specifications Design Professionals: ARCHITECT CIVIL ENGINEER SHEET TO BE FOUND ON A.C.T.ACOUSTICAL CEILING TILE A.F.F.ABOVE FINISHED FLOOR ALUM.ALUMINUM ANOD.ANODIZED APA AMERICAN PLYWOOD ASSOCIATION A.T.ALUMINUM THRESHOLD BRD.BOARD C. TILE CERAMIC TILE CLG.CEILING CPT.CARPET COORD.COORDINATE CONC.CONCRETE DIA.DIAMETER ELEC.ELECTRICAL EXIST.EXISTING EXT.EXTERIOR FND.FOUNDATION Abbreviations Symbols Legend: X X.X A CL SECTION OR ELEVATION NUMBER DIRECTION OF VIEW KEYED NOTE CENTER LINE ELEVATION MARKER START OF WORK A DOOR SYMBOL WALL TYPEA A FINISH NOTE ADDENDUM BULLETIN 1 1 Government Agencies: Schedule Ratings: C- PROTOTYPE Location Map:Vicinity Map: STRUCTURAL ENGINEER N Plumbing Code Analysis: Children Restrooms: Water Closets = 1 per 15 Occupants (NCSPC Section 403) Required: 149 / 15 = 9.93 = 10 Provided: 15 water closets Lavatories = 1 per 25 Occupants (NCSPC Section 403) Required: 149 / 25 = 5.96 = 6 Provided: 17 lavatories Adult Restrooms: Water Closets = 1 per 25 Occupants (NCSPC Section 403) Required: 23 / 25 = 0.92 = 1 Provided: 1 water closet Lavatories = 1 per 35 Occupants (NCSPC Section 403) Required: 23 / 35 = 0.66 = 1 Provided: 1 lavatory Drinking Fountains: 1 per 100 Occupants (NCSPC Section 403) Required: 172 / 100 = 1.72 = 2 Provided: 2 (1 high + 1 low) Effective Codes: Revision Issue Log: N 95 CENTENNIAL PARKWAY CAMERON, NC 28326 SITE SITE MECHANICAL ENGINEER PLUMBING ENGINEER ELECTRICAL ENGINEER BUILDING CODE: North Carolina State Building Code, EDITION: 2012 PLUMBING CODE: North Carolina Plumbing Code, EDITION: 2012 MECHANICAL CODE: North Carolina Mechanical Code, EDITION: 2012 ELECTRIC CODE: National Electric Code, EDITION: 2014 ACCESSIBILITY CODE: North Carolina Building Code, Ch.11, EDITION: 2012 ENERGY CODE: North Carolina Energy Code, EDITION: 2012 FIRE CODE: North Carolina Fire Prevention Code, EDITION: 2012 FLUOR.FLUORESCENT FTG.FOOTING G.C.GENERAL CONTRACTOR GALV.GALVANIZED GYP. BRD.GYPSUM BOARD HGT.HEIGHT INSUL.INSULATION JST.JOIST LAM.LAMINATE L.V.L.LAMINATED VENEER LUMBER MAT'L MATERIAL MAX.MAXIMUM MECH.MECHANICAL MIN.MINIMUM MTD.MOUNTED MTG.MOUNTING MTL.METAL NOM.NOMINAL OPNG.OPENING O.C.ON CENTER PLYWD PLYWOOD PLA POINT LOAD FROM ABOVE RAD.RADIUS REQ'D REQUIRED SIM.SIMILAR S.S.STAINLESS STEEL STL.STEEL T.G. TEMPERED GLASS TYP.TYPICAL U.N.O.UNLESS NOTED OTHERWISE V.C.T.VINYL COMPOSITION TILE W.F.WIDE FLANGE WD.WOOD 04/20/18 APPX-B APPENDIX B JCRCCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (APPENDIX B) Total Number of Occupants: 172 occupants 04/20/18 T.101 FIRE & LIFE SAFETY PLAN JCRCCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT Pre-School 2 Pre-K 2 Staff Lounge Pre-K 1 Pre-School 1 Laundry Rm. Varsity Room Corridor 1 Toddler 1 Gym Infant 1Infant 2 Young Pre-School Central Corridor Vestibule Childs Toilet 4 Childs Toilet 3 Child Toilet 5 Childs Toilet 7 Childs Toilet 9 Childs Toilet 8 Toddler 2 Childs Toilet 6 Gym Child ToiletCloset Gym Equip.Gym Equip. Directors Office Car Seat Sto. Utility Rm. Kitchen Pantry Kitchen Outdoor Toy Storage Closet Adult B.F. Toilet 1 Stair Child Toilet 2 Lobby Reception Conf.Rm. Closet 109 110 134 135 136 138 113 112 132 128 106 108 104 125 124 122 118 102 126 129123 101 100111 117 116 115 114 121 120 127 133 103 105107 119 137 140 Hall 131 I.T. Closet 130 141 PREP SINK HAND SINK FIRE & LIFE SAFETY PLAN 3/16"=1'-0" EGRESS DOOR #1 EGRESS DOOR #2 EGRESS DOOR #3 EGRESS DOOR #4 EGRESS DOOR #5EGRESS DOOR #6 EGRESS DOOR #7 EGRESS DOOR #8EGRESS DOOR #9 EGRESS DOOR #10 EGRESS DOOR #11 EGRESS DOOR #12 EGRESS DOOR #13 EGRESS DOOR #14 Egress Width Per table 1005.1: 0.2 inches per occupant required. Minimum width of one exit is 36" Total Occupant Load:172 Occupants (per T.100) Required Width of Egress:35 Inches Egress Width Provided:504 InchesEQUIPMENT PLATFORM LIFE SAFETY PLAN 3/16"=1'-0" Equipment Platform TRAVEL DISTANCE (T.D.) Legend EXIT SIGN EMERGENCY LIGHTS TRAVEL DISTANCE = 44'-0" TRAVAL DISTANCE = 7'-8"TRAVEL DISTANCE = 41'-0"TRAVEL D ISTANCE = 39 ' -0 "TRAVEL DISTANCE = 43'-0"TRAVEL DISTANCE = 36'-0"TRAVEL DISTANCE = 33'-6"TRA V E L D I S T A N C E = 3 2 ' - 0 " TRAVEL DISTANCE = 81'-0" T. D . = 1 4 ' - 0 " TRAVEL DISTANCE = 12'- 6 " TRAVEL DISTANCE = 17'-0" T RAV E L D I S TANC E = 2 1 ' - 6 " TR A V E L D I S T A N C E = 4 0 ' - 0 "TRAVEL DISTANCE = 37'-0"TRAVEL DISTANCE = 42'-0"TRAVEL DISTANCE = 35'-6"TRAVEL D IS TANCE = 35 ' -6 " TRAVEL DISTANCE = 44'-6" TRAVEL DISTANCE = 64'-0"TRAVEL DISTANCE = 13'-0"TRAVEL DISTANCE = 16'-0"T.D. = 31'-6"General Contractor to provide Access to a Public Way from the fenced playground areas in (1) of the following methods; 1.Provide an 'Area of Safe Dispersal' within the fenced Playground area that is a minimum of 50'-0” away from the building, sized to fit five (5) SF per occupant of the building, provide signage designating 'Safe Dispersal Area', and have a safe and unobstructed path from the building. Refer to “MAXIMUM OCCUPANT LOAD FOR EGRESS” within the code Information on sheet T.100 for the number of occupants. 2.If the criteria for an 'Area of Safe Dispersal' cannot be provided; General Contractor to coordinate with Owner and provide either A) Panic Hardware on all gates leading to a Public Way or B) Ensure all gates enclosing the playground have spring loaded hinges and ensure that there are no closers, latches, locking mechanisms, magnalatches, or any other device installed on the gates in order to ensure free and unobstructed egress from the playground area. ACCESS TO PUBLIC WAY 04/20/18 A.100 FIRST FLOOR WALL FRAMING PLAN JCRCCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT Floor Plan Height Notes: 1.ALL FIRST FLOOR DOOR, WINDOW, AND HEADER HEIGHTS ARE TO BE 6'-8" UNLESS OTHERWISE NOTED. (NOTE: WINDOWS AND DOORS ARE TO LINE-UP IN THE FINISH. ALL ROUGH FRAMING HEIGHTS ARE TO MATCH) 2.ALL FIRST FLOOR CEILING HEIGHTS ARE TO BE 8'-0" EXCEPT FOR OPEN STAIRWELL, GYM & KITCHEN. KITCHEN TO RECEIVE 9'-0" CEILING HEIGHT, GYM TO RECEIVE 12'-0" CEILING HEIGHT 3.MECHANICAL EQUIPMENT PLATFORM CEILING HEIGHTS ARE TO BE 8'-0" UNLESS NOTED OTHERWISE (ATTIC FLOOR PLAN) 4.UNLESS NOTED OTHERWISE ON THE CONSTRUCTION DOCUMENTS, LOCATE ALL DOORS MINIMUM 4" FROM ADJACENT WALLS ON HINGE SIDE. IF A CASING LARGER THEN 2 1/4" IS SELECTED, ADJUST AS NECESSARY. IF DOORS ARE NOT LOCATED NEXT TO ADJACENT WALL, CENTER ON SPACE THEY ENTER INTO. 6.ALL WOOD AND WOOD BASED PRODUCTS WITHIN 8" OF GRADE AND IN CONTACT W/ CONC. OR MASONRY MUST BE PRESSURE TREATED AS REQUIRED PER CODE 7.PROVIDE INTERIOR AND/OR EXTERIOR JAMB EXTENSIONS AS REQ'D FOR ALL WINDOWS VER. W/DESIGNER. 8.PROVIDE MAGNETIC CHILD LOCKS ON ALL CABINET DOORS AND DRAWERS 9. GC TO COORDINATE ALL ROUGH CARPENTRY WITH MEP 10.GC TO COORDINATE CONTROL JOINTS IN DRYWALL WITH MANUFACTURERS RECOMMENDATION TO PREVENT CRACKING. 1.ALL EXTERIOR WALLS ARE TO BE 2X6 WOOD FRAMING U.N.O. 2.INSULATION IN CONCEALED AND EXPOSED SPACES MUST HAVE A FLAME SPREAD RATING OF 25 OR LESS AND SMOKE DEVELOPED INDEX 450 OR LESS PER CODE. 3.ANY OCCUPANT SUSPECTED OF HAVING AN ILLNESS OR DISEASE SHALL BE TAKEN TO THE DIRECTOR'S OFFICE WHERE THEY CAN BE ISOLATED FROM THE OTHER OCCUPANTS AND CARED FOR. IN THE DIRECTOR'S OFFICE THERE SHALL BE A COT FOR THIS PURPOSE. 4.PROVIDE EXTERIOR FROST FREE HOSE BIBS @ LOCATIONS DIRECTED BY M.E.P. 5.PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL MOUNTED ITEMS NOT LIMITED TO THE FOLLOWING: 5.1.DOOR STOPS 5.2.TOWEL BARS 5.3.TOILET TISSUE DISPENSER 5.4.MISC. WALL MOUNTED ACCESSORIES 5.5.MIRRORS General Floor Plan Notes: ALL DIMENSIONS ON FRAMING PLANS ARE TAKEN FROM STUD TO STUD AND DO NOT INCORPORATE THE DRYWALL. Pre-School 2 Pre-K 2 Staff Lounge Pre-K 1 Pre-School 1 Laundry Rm. Varsity Room Corridor 1 Toddler 1 Gym Infant 1Infant 2 Young Pre-School Central Corridor Vestibule Childs Toilet 4 Childs Toilet 3 Child Toilet 5 Childs Toilet 7 Childs Toilet 9 Childs Toilet 8 Toddler 2 Childs Toilet 6 Gym Child ToiletCloset Gym Equip.Gym Equip. Directors Office Car Seat Sto. Utility Rm.Kitchen Pantry Kitchen Outdoor Toy Storage Closet Adult B.F. Toilet 1 Stair Child Toilet 2 Lobby Reception Conf.Rm. Closet6'-7 1/2"5'-8"11'-5"11'-5"3'-5 1/4"16'-10 3/4" 26'-9" 153'-0" 28'-0"11'-5 1/2"5'-8"15'-3"2'-9"3'-11"4'-1"2'-1"10'-6"58'-11"15'-4"14'-0"15'-4"21'-7 1/2"24'-0 1/2"5'-8"5'-8"2'-8"90'-4"2'-8" 7'-0" 12'-1 1/2"6'-9 1/2"9'-2"5'-10" 8" 51'-7"46'-8"28'-0"2'-0"3'-6 1/2"6'-2"46'-8"78'-4"5'-4 1/2"2'-9"11'-0 7/8"4'-5"2'-0"4'-0 1/8"3'-8"39'-1"11'-4"4'-4" 27'-8 1/2"8'-2"28'-1 3/8"6'-1 1/4"6'-1 1/4"2'-5 1/4"27'-8 1/8"8'-7 1/2"2'-5 1/4"5'-0"5'-0" 3'-11 3/4" 2'-5 1/4"2'-5 1/4"12'-1 1/8" 18'-0"16'-5 1/2"29'-5 1/8"32'-5 1/4"14'-2 1/2"7'-3 1/8"5'-4" 4'-11 1/2"EQ.8'-2"8'-0"7'-10"9'-8 1/8"9'-8 1/4"10'-9 7/8"33'-4 3/8"8'-0 1/8"19'-5 3/8" 2'-6" 7'-7 1/8"21'-0 5/8"21'-6"6'-1 1/4"8'-4 1/4"5'-1 1/2" 3'-0"22'-5 3/8"27'-8 3/8"2'-0" 9'-1 7/8" 5'-0 7/8" 8'-10 1/4" 8'-0" 8'-0"MIN. 18"9 7/8" 9'-7 1/8" 10'-7"10'-3 1/2"4'-6 1/2"11'-3 1/2"10'-0"8'-3 1/8"6'-1 1/4" 5'-0" 9'-8 1/2" 60" MIN. 2'-6" MIN. 2'-5 1/4"5'-0"4'-0 1/4"27'-0"4'-0 1/4"4'-0 1/4"A B B B D B B D D DD BD D A A B B B B B B B BD D B B B B B B B B A A B B D D D D B B D D D B B BB D B D D B B B D B D B D D B DD B B B H H D H D B B BB A A B 8'-1 3/8"13'-11 7/8"10'-5"23'-11 1/8" 6'-11 1/4" 109 110 134 135 136 138 113 112 132 128 106 108 104 125 124 122 118 102 126 129123 101 100 111 117 116 115 114 121 120 127 133 103 105 107 119 139 137 140 21'-7"28'-1 3/8"5'-3 3/4"6'-1 1/4"2'-5 1/4"5'-0" 29'-4"10'-5"5'-4 1/2"5'-0"35'-2 7/8"8'-0 1/8"4'-1 1/4"13'-9 1/2"EQ.EQ.8'-2"10'-9 7/8" 23'-1 1/4" 21'-6"8'-4 1/4"8'-7 1/2"8'-0 1/8"5'-0 5/8"9'-11"8'-2 3/8" 3'-0"1'-8"2'-1 3/4"8'-2 3/8"MIN. 18"5'-6"9'-5 3/8"6'-1 3/4"9'-7 1/8"12'-4 1/2"8'-3 1/8"25'-0" 9'-1 7/8" 9'-5 3/8" 2'-6" MIN.2'-5 1/4"11'-3 1/8"6'-11 1/4"6'-11 1/4" CEILING HGT. 9'-0" A.F.F. VAULT. CEILING HGT. 12'-0" A.F.F. CEILING HGT. 12'-0" A.F.F.CEILING HGT. 8'-0" A.F.F. Hall 131 2'-5 1/4"5'-0"2'-5 1/4" 17'-11"30'-0 1/4"32'-5 3/4"9'-6 5/8"16'-5 3/8" B 11 1/8"6'-11 7/8"45°3'-6 1/2"45°7'-11 3/4"7' - 1 1 3 / 4 "5'-1 1/4"6'-1 1/4"4'-0 1/4"4'-0 1/4"3'-0" I.T. Closet 130 141 D B D D D A A A A A A B A DD B D D H A B D B A A A REF.FREEZ.FUTURE REF. COMBO OVEN UNIT 3'-0 3/4"3'-1 7/8" CEILING HGT. 12'-0" A.F.F.4'-0 1/4"7'-5 1/4"9'-3 1/8"9'-3 1/8"7'-5 1/4"BB9'-7 7/8"2'-2"11'-5 1/2"TYP.15'-6"6'-3"14'-3"10'-9"18'-4 1/2"4'-5 1/2"8'-2 1/2"17'-6" 2'-11"11'-7 3/4"20'-6 1/4"4'-1"11'-10 1/4"14'-3 1/2"4'-3 1/2"8'-2 1/2"17'-6"5'-2"3'-4"3'-4"3'-4"5'-2"5'-2"5'-2"1'-5"3'-4"5'-2"3'-4"3'-4"5'-2"5'-2"3'-4"5'-2"2'-10 1/2"3'-4"2'-10 1/2"5'-2"3'-8"5'-2"5'-2"7'-0"9'-3"5'-2"4'-5"3'-6 1/2"2'-10"3'-2"2'-10"3'-2"2'-10"3'-3"23'-4"3'-4"3'-10 1/2"3'-4"2'-6"5'-2"7'-8"5'-2"2'-5 1/4"3'-4"7'-10"5'-2"5'-2 1/2"8'-0"3'-4"3'-1 1/2"5'-2"10'-7 1/2"5'-2"11'-3"11'-5"5'-2"11'-5"9'-3"PREP SINK HAND SINK FIRST FLOOR WALL FRAMING PLAN 3/16"=1'-0"3'-4"2'-10 1/2"20'-10 5/8" D 5'-3 3/8"4'-4 5/8"4'-4 5/8"B9'-0 7/8"B13'-5 1/4"11'-5 1/2"6'-7 1/2"D Wall Legend X 2X6 INTERIOR PARTITION WALL: 5/8" GYPSUM BOARD EACH SIDE OF 2X6 WOOD STUDS @ 16" O.C. PROVIDE ACOUSTICAL SOUND BATT INSULATION @ ALL INTERIOR WALLS AS DIRECTED BY OWNER INTERIOR PARTITION WALL: 1 LAYER TYPE 'X' 5/8" GYPSUM BOARD EACH SIDE OF 2X4 WOOD STUDS @ 16" O.C. PROVIDE ACOUSTICAL SOUND BATT INSULATION @ ALL INTERIOR WALLS AS DIRECTED BY OWNER NOTE: ALL OPENINGS, DOORS AND WINDOW FRAMES ARE TO BE FIRE CAULKED A B C INTERIOR EQUIPMENT ENCLOSURE WALL: PROVIDE (1) LAYER OF 5/8" GYPSUM BOARD ON THE INSIDE AND 2X WOOD STUD AS REQUIRED TO PROVIDE CAVITY FOR A TOTAL INSULATION OF R-38. SEE DETAIL 5/A.303 F EXTERIOR WALL (BRICK): EXTERIOR BEARING WALL: BRICK VENEER EXTERIOR FINISH W/ 1" AIR SPACE ON TYVEK AIR INFILTRATION BARRIER ON 1/2" APA RATED PLYWOOD SHEATHING ON 2X6 WOOD STUDS @ 16" O.C. W/ R-19 KRAFT FACED BATT INSUL. W/ 5/8" GYPSUM BOARD FINISH General Wall Type Notes: 1.ALL INTERIOR WALLS ARE ASSUMED WALL TYPE "D" U.N.O. 2.ALL EXTERIOR WALLS ARE ASSUMED WALL TYPE "A" U.N.O. DRAFTSTOPPING WALL: 3/8" PLYWOOD ON ONE SIDE OF PRE-ENG. ROOF TRUSS. RUN UP TO UNDER SIDE OF ROOF SHEATHING (SEE TYPICAL DETAIL ON SHEET A.305 FOR ADDITIONAL INFORMATION) GINTERIOR PARTITION WALL: 1 LAYER TYPE 'X' 5/8" GYPSUM BOARD EACH SIDE OF 2X6 WOOD STUDS @ 16" O.C. PROVIDE ACOUSTICAL SOUND BATT INSULATION @ ALL INTERIOR WALLS AS DIRECTED BY OWNER NOTE: ALL OPENINGS, DOORS AND WINDOW FRAMES ARE TO BE FIRE CAULKED E TYPICAL INTERIOR PARTITION WALL: 2X4 STUDS @ 16" O.C. WITH 5/8" GYP. BOARD EACH SIDE. PROVIDE ACOUSTICAL SOUND BATT INSULATION @ ALL INTERIOR WALLS AS DIRECTED BY OWNER D 1-HR. RATED 1-HR. RATED NOT U S E D NOT U S E D TYPICAL INTERIOR PARTITION WALL: 2X4 STUDS @ 12" O.C. WITH 5/8" GYP. BOARD EACH SIDE. PROVIDE ACOUSTICAL SOUND BATT INSULATION @ ALL INTERIOR WALLS AS DIRECTED BY OWNER H 5'-2"F.E. F.E. F.E.F.E. COMBO OVEN UNIT8'-0 1/2"2'-2"2'-2"4'-2 5/8"2'-4" 04/20/18 A.101 FIRST FLOOR PLAN JCRCCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT W1 W1 W1 W1 W1 W1 W1W1 W1W1 W1W1 W1 W1 W1 27'-7 1/4"8'-0 11/16"21'-5 11/16"28'-0 1/8"6'-0"5'-2 1/2"6'-0"2'-4"5'-0" 29'-2 11/16" 27'-7 1/4"8'-6 3/16"10'-3 3/4"2'-4 1/8"5'-3 1/4"5'-0"5'-0"5'-0" 13'-7 1/4" 2'-4"2'-4"12'-0 1/2" 17'-10 3/4"16'-4 3/16"29'-3 7/8"32'-4"7'-10 13/16"14'-1 1/4"3'-11 15/16"7'-1 3/4"5'-4"13'-7 1/4" 4'-10 1/4"EQ.EQ.8'-1 13/16"4'-10 1/8"7'-8 3/4"9'-6 13/16"9'-6 15/16"10'-9 5/16"33'-3 1/8"7'-10 3/4"19'-4 1/8" 2'-6" 22'-11 15/16" 7'-5 15/16"20'-11 3/16"21'-4 9/16"6'-0"8'-2 7/8"8'-7 1/2"7'-10 7/8"5'-0"9'-11"5'-0 3/16" 8'-1" 3'-0"22'-4 1/8"27'-7 1/8"18" 2'-0" 9'-0 5/8" 5'-0 7/8" 8'-9 15/16" 7'-10 3/4" 8'-1 1/8"MIN. 18"MIN. 18"11 1/8"5'-4 3/4"6'-0 1/2"9'-5 13/16" 10'-5 3/4"10'-2 1/4"4'-5 1/4"11'-2 1/4"12'-3 1/4"9'-10 3/4"8'-3 1/8"9'-0 5/8" 5'-0" 9'-7 1/4" 60" MIN. 2'-6" MIN. 2'-3 15/16"5'-0"3'-10 15/16"26'-10 3/4"3'-10 15/16"8'-0 1/16"13'-10 5/8"10'-3 11/16"2'-4 3/4"23'-9 7/8"11'-2"6'-10"6'-10" 7'-10 3/4"8'-1 1/16"4'-0"24'-10 3/4" W4 W2 W2 W2 W2 W2 W2 W2 W2 2'-4"5'-0"8'-11 5/8"11'-3 5/16"5'-0 3/16"45°3'-6 1/2"2'-8 1/8" 7'-0 15/16"3'-11"3'-11"3'-0" (TYP)(TYP)(TYP)(TYP)(TYP) 7'- 1 1 3 / 4 "8'-0 1/16"3 17 17 16 15 2 73 12 11 3 3 6 6 19 17 6 4 6 6 15 8 8 9 9 24 2424 24 24 24 24 24 24 6 24 6 9'-10 15/16"10'-2 7/8"7'-5 3/4"7'-5 3/4"8'-2 13/16"4'-0 5/16"6'-0"2'-7 3/16"11 3/8"3 14'-7 3/8"9'-0 1/4"W5 W5 W5 W5 W5 W5 W5 W5 W5W6W5 WINDOWS ABOVE IN CLEARSTORY SEE SHEET A.102.1 FOR INFO. CLEARSTORY ABOVE U.C. REF. (TYP.)1'-8"4'-0"3'-0 3/4"3'-1 7/8"3'-11"(TYP)(TYP)17'-5 3/8"8'-2 1/2"4'-3 1/2"14'-3 9/16"11'-10 1/4"4'-0 7/8"27'-11 15/16"11'-5 1/2"Floor Plan Height Notes: 1.ALL FIRST FLOOR DOOR, WINDOW, AND HEADER HEIGHTS ARE TO BE 6'-8" UNLESS OTHERWISE NOTED. (NOTE: WINDOWS AND DOORS ARE TO LINE-UP IN THE FINISH. ALL ROUGH FRAMING HEIGHTS ARE TO MATCH) 2.ALL FIRST FLOOR CEILING HEIGHTS ARE TO BE 8'-0" EXCEPT FOR OPEN STAIRWELL, GYM & KITCHEN. KITCHEN TO RECEIVE 9'-0" CEILING HEIGHT, GYM TO RECEIVE 12'-0" CEILING HEIGHT 3.MECHANICAL EQUIPMENT PLATFORM CEILING HEIGHTS ARE TO BE 8'-0" UNLESS NOTED OTHERWISE (ATTIC FLOOR PLAN) 4.UNLESS NOTED OTHERWISE ON THE CONSTRUCTION DOCUMENTS, LOCATE ALL DOORS MINIMUM 4" FROM ADJACENT WALLS ON HINGE SIDE. IF A CASING LARGER THEN 2 1/4" IS SELECTED, ADJUST AS NECESSARY. IF DOORS ARE NOT LOCATED NEXT TO ADJACENT WALL, CENTER ON SPACE THEY ENTER INTO. General Floor Plan Notes: FIRST FLOOR PLAN 3/16"=1'-0"ALL DIMENSIONS ON FLOOR PLANS ARE TAKEN FROM FINISH TO FINISH & INCLUDE THE 5/8" GYP. BOARD 1.NOT USED. 2.PROVIDE F.R.P. (WHITE OR AS DIRECTED BY OWNER) TO A 60" A.F.F. BEHIND MOP SINK 3.PROVIDE 16" DEEP WIRE SHELVING OVER TO OWNER SPECIFICATION 4.BUILT-IN CAR SEAT CUBBIES 5.PARTITIONED STORAGE UNITS (BY OWNER) 6.COT STORAGE AREA - PROVIDE FULL HEIGHT F.R.P. WITH OS CORNER PROTECTION. REFER TO SHEET A.105 FOR TYP. LOCATION. 7.LOCATE DRYER VENT IN WALL CAVITY 8.PROVIDE 2X6 BLOCKING IN WALLS @ 42" A.F.F. TO CENTER @ ENTIRE PERIMETER OF GYM 9.MASONRY PIER. REFER TO STRUCTURAL DRAWINGS FOR DETAIL - STRUCTURAL STEEL IS TO BE LOCATED WITHIN COLUMN 10.KNOX-BOX RAPID ENTRY SYSTEM, OR APPROVED EQUAL. COORDINATE EXACT LOCATION AND TYPE WITH FIRE MARSHAL. COORDINATE WITH FIRE MARSHAL IF A TRUSS SIGN IS REQUIRED, AND IF SO PROVIDE THE TYPE, LOCATION, AND DESIGNATION AS REQUIRED. 11.PROVIDE BLOCKING IN WALL FOR T.V. MOUNT - 72" WIDE @ 65" A.F.F. TO MID POINT 14'-4" FROM ADJACENT VESTIBULE WALL (VERIFY EXACT LOCATION WITH OWNER) 12.PROVIDE 12" X 12" HORIZONTAL BLOCKING, FINISHED TO ACCOMMODATE CEILING MOUNTED LIGHT FIXTURE 13.PROVIDE BLOCKING AS REQ'D 54"-78" A.F.F. FOR WALL MOUNTED BASKETBALL HOOP - EXACT LOCATION TO BE VERIFIED BY OWNER 14.PROVIDE WALL MOUNTED MOP HOOKS AND SHELVING 15.DOOR TO BE LOCKED AND INACCESSIBLE TO CHILDREN 16.ADA COMPLIANT HIGH/LOW DRINKING FOUNTAIN 17.CHANGING LOCATION 18.CONDENSING UNIT PAD 19.AREA OF EQUIPMENT PLATFORM (ABOVE) 20.LOCATION OF FUTURE WALL 21.SEE CIVIL DRAWINGS BY OTHERS FOR EXTERIOR WALK LOCATIONS & DETAILS 22.FUTURE DOOR - FRAME IN OPENING 23.LINE OF STAIRS & SLOPED CEILING (ABOVE) - PROVIDE STORAGE SPACE UNDER STAIRS 24.PROVIDE BLOCKING FOR 4' W. X 15" X 20" CUBBIES TO BE INSTALLED @ (SEE BELOW) 24.1 ROOMS 109,112,117,119, & 121 @ 36" A.F.F 24.2 ROOM 106 @ 47 1/2" 24.3 ROOM 104 @ 39 1/2" 25.CHAINLINK FENCE, GATES, LATCH & PAD LOCK 26.GC SHALL PROVIDE AND INSTALL FIRE EXTINGUISHER CABINET 1 10LB ABC FIRE EXTINGUISHER AT LOCATION SHOWN. CABINET SHALL BE ELITE SERIES SEMI-RECESSED VERTICAL DUO EXTINGUISHER CABINET, 8"W X 16-3/4"H X 5"D OR APPROVED EQUAL. FIRE EXTINGUISHER CABINETS ARE REQUIRED TO BE IDENTIFIED PER SECTION 905.7.1. 27.GC SHALL PROVIDE AND INSTALL 1 WALL MOUNTED 10LB K TYPE FIRE EXTINGUISHER. 28.TACTILE EXIT SIGNAGE IS REQUIRED TO BE INSTALLED ADJACENT TO EACH STAIRWAY EXIT DOOR AND EACH EXTERIOR EXIT DOOR. Keyed First Floor Plan Notes:X Pre-School 2 Pre-K 2 Staff Lounge Pre-K 1 Pre-School 1 Laundry Rm. Varsity Room Corridor 1 Toddler 1 Gym Infant 1Infant 2 Young Pre-School Central Corridor Vestibule Childs Toilet 4 Childs Toilet 3 Child Toilet 5 Childs Toilet 7 Childs Toilet 9 Childs Toilet 8 Toddler 2 Childs Toilet 6 Gym Child ToiletCloset Gym Equip. Directors Office Car Seat Sto. Utility Rm.Kitchen Pantry Kitchen Outdoor Toy Storage Closet Adult B.F. Toilet 1 Stair Child Toilet 2 Lobby Reception Conf.Rm. Closet 109 110 134 135 136 138 113 112 132 128 106 108 104 125 124 122 118 102 126 129 123 101 100111 117 116 114 121 120 127 133 103 105 107 119 139 137 140 Hall 131 I.T. Closet 130 141 REF.FREEZ.FUTURE REF. 118 105 110 135 123 137 104128 134 140 109-A 134-A 136 112 106 138 113 112-A 119-A 119 127139 103 125 124 122 116 100-B 100-A 101 131-A124-A 106-A 108 107 109 137-A 121-A 114 115 116-A 121 117 100 125-A 104-A 132 120 120-A 131 141 130 PREP SINK HAND SINK 14 21 21 6.ALL WOOD AND WOOD BASED PRODUCTS WITHIN 8" OF GRADE AND IN CONTACT W/ CONC. OR MASONRY MUST BE PRESSURE TREATED AS REQUIRED PER CODE 7.PROVIDE INTERIOR AND/OR EXTERIOR JAMB EXTENSIONS AS REQ'D FOR ALL WINDOWS VER. W/DESIGNER. 8.PROVIDE MAGNETIC CHILD LOCKS ON ALL CABINET DOORS AND DRAWERS 9. GC TO COORDINATE ALL ROUGH CARPENTRY WITH MEP 10.GC TO COORDINATE CONTROL JOINTS IN DRYWALL WITH MANUFACTURERS RECOMMENDATION TO PREVENT CRACKING. 1.ALL EXTERIOR WALLS ARE TO BE 2X6 WOOD FRAMING U.N.O. 2.INSULATION IN CONCEALED AND EXPOSED SPACES MUST HAVE A FLAME SPREAD RATING OF 25 OR LESS AND SMOKE DEVELOPED INDEX 450 OR LESS PER CODE. 3.ANY OCCUPANT SUSPECTED OF HAVING AN ILLNESS OR DISEASE SHALL BE TAKEN TO THE DIRECTOR'S OFFICE WHERE THEY CAN BE ISOLATED FROM THE OTHER OCCUPANTS AND CARED FOR. IN THE DIRECTOR'S OFFICE THERE SHALL BE A COT FOR THIS PURPOSE. 4.PROVIDE EXTERIOR FROST FREE HOSE BIBS @ LOCATIONS DIRECTED BY M.E.P. 5.PROVIDE SOLID BLOCKING IN WALLS FOR ALL WALL MOUNTED ITEMS NOT LIMITED TO THE FOLLOWING: 5.1.DOOR STOPS 5.2.TOWEL BARS 5.3.TOILET TISSUE DISPENSER 5.4.MISC. WALL MOUNTED ACCESSORIES 5.5.MIRRORS 212518 13 8 8 1717 1717 21 8 W7 W8 W7 W7 W8 W8 25 W3 W3 W3 W9 W9 W1 W8 4'-5 1/4" 10 3'-5" 27 26 26 NOTE: DOOR DIMENSIONS THIS ROOM ARE TO OUTSIDE EDGE OF DOOR FRAMES.19'-6 3/8"3'-4"2 1/4"1'-11 3/4"3'-4"1"Gym Equip. 115 6'-0"9'-5 3/8"9'-5 3/8" COMBO OVEN UNIT COMBO OVEN UNIT 28 26 28 28 T.G.T.G. T.G. T.G.2'-2"7'-11 5/16"2'-1 15/16"2'-4"4'-1 3/8" 04/20/18 A.102 FIRST FLOOR KEY PLAN JCRCCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT FIRST FLOOR KEY PLAN 3/16"=1'-0" Pre-School 2 Pre-K 2 Staff Lounge Pre-K 1 Pre-School 1 Laundry Rm. Varsity Room Corridor 1 Toddler 1 Gym Infant 1Infant 2 Young Pre-School Central Corridor Vestibule Childs Toilet 4 Childs Toilet 3 Child Toilet 5 Childs Toilet 7 Childs Toilet 9 Childs Toilet 8 Toddler 2 Childs Toilet 6 Gym Child ToiletCloset Gym Equip. Directors Office Car Seat Sto. Utility Rm. Kitchen Pantry Kitchen Outdoor Toy Storage Closet Adult B.F. Toilet 1 Stair Child Toilet 2 Lobby Reception Conf.Rm. Closet 20 A.401 109 110 134 135 136 138 113 112 132 128 106 108 104 125 124 122 118 102 126 129123 101 100111 117 116 114 121 120 127 133 103 105 107 119 139 137 140 Hall 131 9 A.400 23 A.401 27 A.401 23 A.401 23 A.401 30 A.401 9 A.400 25 A.401 26 A.401 31 A.402 22 A.401 33 A.402 4 A.400 15 A.400 32 A.402 36 A.402 37 A.402 35 A.402 24 A.401 1 A.402 24 A.401 30 A.401 8 A.402 13 A.400 34 A.402 38 A.402 21 A.401 9 A.400 29 A.401 24 A.402 26 A.401 28 A.401 12 A.400 11 A.400 9 A.400 E.9 A.400 2 A.400 EP-7 A.102.1 EP-6 A.102.1 EP-2 A.102.1 EP-4 A.102.1 EP-3 A.102.1 I.T. Closet 130 141 EP-2 A.102.1 EP-5 A.102.1 EP-1 A.102.1 REF.FREEZ.FUTURE REF. 5 A.400 4 A.304 PREP SINK HAND SINK 9 A.400 SIM. E A.301 E A.301 C A.300 C A.300 A A.300 A A.300 H A.302 H A.302 F A.301 F A.301 OPP. OPP. SIM. OPP. SIM. G A.302 G A.302 B A.300 TOILET HEIGHT LEGEND 39 A.402 40 A.402 41 A.402 1 A.200 2 A.200 1 A.201 2 A.201 J A.305 D A.301 D A.301 10 A.400 5 A.305 Gym Equip. 115 COMBO OVEN UNIT COMBO OVEN UNIT 04/20/18 A.102.1 ENLARGED FLOOR PLANS JCRC Gym Clearstory PlanEP-1 A.102.1 Scale: 1/2" = 1'-0" Enlarged Floor Plan @ Reception AreaChild B.F. Restroom PlanEP-5 A.102.1 Scale: 1/2" = 1'-0" Child B.F. Restroom PlanEP-4 A.102.1 Scale: 1/2" = 1'-0" Child B.F. & Adult Restroom PlanEP-6 A.102.1 Scale: 1/2" = 1'-0" EP-7 A.102.1 Scale: 1/2" = 1'-0" Child B.F. Restroom PlanEP-3 A.102.1 Scale: 1/2" = 1'-0" Child B.F. Restroom PlanEP-2 A.102.1 Scale: 1/2" = 1'-0" CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT W5 W5 W5 W5 W5 W5 W5 W5 W5W8W6W5 2 A.304 NOTE: SEE WINDOW SCHEDULE SHEET A.500 7 1/2"2'-6"23'-6 1/2"4"2'-6"4"2'-6"4"2'-6"4"2'-6"4"2'-6"4"2'-6"4"2'-6"7"7 1/4"2'-6"4"5'-0"4"2'-3 1/2"4"3'-4"4"2'-3 1/2"4"5'-0"4"2'-6"6 3/4" W8 W9 W9 1'-0"CL 5'-0 1/4"12"(MAX)42"(MIN)34" - 36"54"(MIN)9'-6 3/4"Child Toilet 4 108 CL 2'-6" 2'-0"2'-0"1'-3 1/2"CL Child Toilet 7 138 Child Toilet 8 113 12"CL 42"(MIN) 34" - 36" 54"(MIN) 6'-10"U 6'-10"11'-2"3'-0"5'-0"1'-3 1/2"1'-0"4'-10 1/2"CL CL 34" - 36"5'-0 1/2"CL CL CL CL 3'-0"2'-0"2'-0"2'-0"2'-0"5'-3 1/2"2'-10"5'-9 3/8"5'-0"8'-9 1/2"1'-0"7'-4 3/4"2'-0"10 1/2"5'-7"4'-3 3/4"Reception 102 1'-6" LINE OF BASE WALL BELOW (DASHED) PROVIDE (2) 1-1/2" GROMETS IN C. TOP (VERIFY EXACT LOCATION W/ OWNER) - TYPICAL 30" HIGH COUNTER TOP LINE OF RECEPTION AREA BUILT-IN BOOKCASE (SEE A.401 FOR ADDITIONAL INFORMATION) 30" COUNTER TOP 42" HIGH COUNTER TOP TO PROJECT PAST BASE A MAX. OF 2" (V.I.F.)R3'-3 3/4"48" (MIN)30" (MIN)9'-7"1'-0"16"-18" 12"(MIN)24"(MIN) 36"(MIN) CL CL 12"(MAX)42"(MIN)39"-41"54"(MIN)8'-11 3/4"5'-7" 3'-2" 8'-1" 8' - 0 1 / 2 " Adult B.F. Toilet 1 103 Child Toilet 2 105 34" - 36"4'-7"48" (MIN.)30" (MIN.)3'-0"1'-8"12"(MAX)42"(MIN)39"-41"54"(MIN)1'-6"CL 2'-0 1/2" CL CL 2'-0"2'-0" 3'-0 1/2" 1'-0" CL12"(MAX)42"(MIN)34" - 36"54"(MIN)8'-2 3/4"8'-1" 30" (MIN)48" (MIN)Child Toilet 9 120 3'-0"CL 1'-3" 1'-6" CL 3'-0 1/2" 2'-0"2'-0" Child Toilet 6 135 1'-0"CL 12"(MAX)42"(MIN)34"-36"54"(MIN)CL 1'-3" 7'-10 3/4"10'-3 3/4"3'-0"1'-5 1/2"CL 2'-9 3/4"CL 2'-0"2'-0" 04/20/18 A.103 ATTIC PLAN JCRC Scale: 3/16" = 1'-0" Attic Floor Plan Scale: 3/16" = 1'-0" Attic Framing Plan 514 SQ. FT. CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT Mechanical Equip. Platform 201 Attic 'B' Attic 'D' 31'-3 5/8"13'-7 7/8"10'-8 3/4" 16 RISERS DOWN 5'-6"3'-3 1/2"9'-11 1/2"F D F F G GG F 18'-11 3/4"F F11'-8 3/4" G 200 Attic 'C' Attic 'B' G F 3'-0"ATTIC PLAN 3/16"=1'-0"1.SEE SHEET MECHANICAL DRAWINGS FOR EXACT LOCATION OF FURNACES 2.SEE SHEET A-101 FOR LOCATION OF MECHANICAL EQUIPMENT PLATFORM IN RELATION TO FIRST FLOOR-INDICATED BY DASHED LINE General Attic Plan Notes: 1.3/4" FIRE RETARDANT TREATED PLYWOOD FLOOR DECKING 2.PROVIDE (1) LAYER OF 5/8" GYP. BRD. @ CEILING 3.PRE-FIN BREAK MTL. CAP W/DRIP EDGE 4.PRIMARY ROOF SUMP (VER. EXACT LOCATION W/ MEP ENGINEER) 5.EMERGENCY OVERFLOW ROOF SUMP (VER. EXACT LOCATION W/MEP ENGINEER) 6.SINGLE PLY - 60 MIL. EPDM ROOF ON TAPERED INSULATION 7.PITCHED TO DRAIN (TYP.) 8.A/C CONDENSER (VER. EXACT LOCATION W/MEP ENGINEER) 9.NOTE: THESE WALLS ARE TO BE DETERMINED BY TRUSS MANUF. INTENT IS TO HAVE SIMILAR CONSTRUCTION TO WALL TYPE "F" (NOTIFY ARCHITECT OF ANY DISCREPANCIES) 10.FLOOR DRAIN (VER. EXACT LOCATION W/MEP ENGINEER) 11.34" HIGH HANDRAIL PER CODE EACH SIDE 12.PROVIDE METAIL NOSING ON STAIR W/PAINTED TREADS & RISERS (GREY) 13.R-38 KRAFT FACE BATTS BELOW LANDINGS & CATWALK 14.PROVIDE LANDING THAT IS FLUSH W/ MECHANICAL ENCLOSURE LEVEL 15.3'-0" X 6'-8" SELF-CLOSING ACCESS DOOR TO EACH DRAFTSTOPPING ATTIC AREA - COORDINATE EXACT LOCATION IN FIELD W/MECHANICAL, ELECTRICAL AND PLUMBING TRADES TO AVOID INTERFERENCE WITH MECH. EQUIP., WATER HEATERS, ETC. 16.SCAB ON 2X FRAMING TO BOT. CHORD OF TRUSS TO BRING VATWALK TO SAME ELEV. AS EQUIPMENT PLATFORM FLOOR 17.LIMESTONE SILL (BELOW) 18.WATER HEATER (VER. EXACT SIZE, LOCATION & CLEARANCES REQ'D. W/MEP ENGINEER) - PROVIDE METAL DRAIN PAN @ EACH W.H. (TYP.) 19.MECH. EQUIP. (VER. EXACT SIZE, LOCATION AND CLEARANCES REQ'D. W/ MEP ENGINEER) 20.LINE OF FIRST FLOOR WALL (BELOW) 21.LINE OF DRAFTSTOPPING - VER. LOCATION W/TRUSS MANUF. 22.PROVIDE SELF-CLOSING ACCESS DOOR TO EACH DRAFT STOPPING AREA W/AUTOMATIC LATCHES - REFER TO SHT. A.305 23.GC SHALL PROVIDE AND INSTALL 1 WALL MOUNTED 10LB ABC FIRE EXTINGUISHER IN THE MECH. EQ. PLATFORM. Keyed Attic Plan Notes:X Wall Legend X 2X6 INTERIOR PARTITION WALL: 5/8" GYPSUM BOARD EACH SIDE OF 2X6 WOOD STUDS @ 16" O.C. PROVIDE ACOUSTICAL SOUND BATT INSULATION @ ALL INTERIOR WALLS AS DIRECTED BY OWNER INTERIOR PARTITION WALL: 1 LAYER TYPE 'X' 5/8" GYPSUM BOARD EACH SIDE OF 2X4 WOOD STUDS @ 16" O.C. PROVIDE ACOUSTICAL SOUND BATT INSULATION @ ALL INTERIOR WALLS AS DIRECTED BY OWNER NOTE: ALL OPENINGS, DOORS AND WINDOW FRAMES ARE TO BE FIRE CAULKED A B C INTERIOR EQUIPMENT ENCLOSURE WALL: PROVIDE (1) LAYER OF 5/8" GYPSUM BOARD ON THE INSIDE AND 2X WOOD STUD AS REQUIRED TO PROVIDE CAVITY FOR A TOTAL INSULATION OF R-38. SEE DETAIL 5/A.303 F EXTERIOR WALL (BRICK): EXTERIOR BEARING WALL: BRICK VENEER EXTERIOR FINISH W/ 1" AIR SPACE ON TYVEK AIR INFILTRATION BARRIER ON 1/2" APA RATED PLYWOOD SHEATHING ON 2X6 WOOD STUDS @ 16" O.C. W/ R-19 KRAFT FACED BATT INSUL. W/ 5/8" GYPSUM BOARD FINISH General Wall Type Notes: 1.ALL INTERIOR WALLS ARE ASSUMED WALL TYPE "D" U.N.O. 2.ALL EXTERIOR WALLS ARE ASSUMED WALL TYPE "A" U.N.O. DRAFTSTOPPING WALL: 3/8" PLYWOOD ON ONE SIDE OF PRE-ENG. ROOF TRUSS. RUN UP TO UNDER SIDE OF ROOF SHEATHING (SEE TYPICAL DETAIL ON SHEET A.305 FOR ADDITIONAL INFORMATION) GINTERIOR PARTITION WALL: 1 LAYER TYPE 'X' 5/8" GYPSUM BOARD EACH SIDE OF 2X6 WOOD STUDS @ 16" O.C. PROVIDE ACOUSTICAL SOUND BATT INSULATION @ ALL INTERIOR WALLS AS DIRECTED BY OWNER NOTE: ALL OPENINGS, DOORS AND WINDOW FRAMES ARE TO BE FIRE CAULKED E TYPICAL INTERIOR PARTITION WALL: 2X4 STUDS @ 16" O.C. WITH 5/8" GYP. BOARD EACH SIDE. PROVIDE ACOUSTICAL SOUND BATT INSULATION @ ALL INTERIOR WALLS AS DIRECTED BY OWNER D 1-HR. RATED 1-HR. RATED NOT U S E D TYPICAL INTERIOR PARTITION WALL: 2X4 STUDS @ 12" O.C. WITH 5/8" GYP. BOARD EACH SIDE. PROVIDE ACOUSTICAL SOUND BATT INSULATION @ ALL INTERIOR WALLS AS DIRECTED BY OWNER H NOT U S E D 1819 19 19 19 Mechanical Equip. Platform 11 12 201 Attic 'B' Attic 'D' 21 99 1616 15 1515 21 21 200 14 Attic 'C' Attic 'B' 19 2 14 13 23 04/20/18 A.104 ROOF PLAN JCRCCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT ROOF PLAN 3/16"=1'-0" Attic Space A 2506 Sq. Ft. Attic Space B 2973 Sq. Ft. Attic Space C 2014 Sq. Ft. 6 6 8 8 8 8 8 8 12 5 7 7 7 . 9 . 9 9 .9 .. 9 4 4 4 4 4 4 4 12 12 1212 1 1 1 1 1 1 1 Attic Space D 2206 Sq. Ft. Attic Space E 2241 Sq. Ft. 13 7 7 Attic 'A' Ventilation Calculation: 1 SQ. FT. OF ATTIC VENT PER 300 SQ. FT. OF ATTIC FLOOR SPACE (OVER ALL PERIMETER OF ROOF) TOTAL ATTIC SPACE: 2,506 SQ. FT 2,506 SQ. FT. / 300 SQ. FT. = 8.4 SQ. FT. 8.4 SQ. FT. / 2 (INTAKE/EXHAUST) = 4.1 SQ. FT. 4.1 SQ. FT. X 144 IN. = 590.4 SQ. IN. (NET FREE AREA REQUIRED) VENTILATION EXHAUST CALCULATIONS: ROOF LOUVER: B-144 ROUND METAL DOME VENT BY AIR VENT EQUALS 144 NFA PER PIECE: 590.4 SQ. IN / 144 NFA = 4.1 STATIC VENTS REQ'D. PROPOSED VENTILATION EXHAUST: 4 STATIC ROOF VENTS PROVIDED VENTILATION INTAKE CALCULATIONS: 590.4 SQ.IN. (NET FREE AREA REQUIRED - SEE ABOVE) AIR VENT UNDER EAVE VENT 16"X6" EQUALS 42 SQ.IN. NFA PER PIECE: 590.4 SQ.IN. / 42 NFA = 14.1 = 14 VENTS REQ'D. PROPOSED VENTILATION INTAKE: 14 VENTS PROVIDED VENTILATION DIAGRAM PLAN Attic 'B' Ventilation Calculation: 1 SQ. FT. OF ATTIC VENT PER 300 SQ. FT. OF ATTIC FLOOR SPACE (OVER ALL PERIMETER OF ROOF) TOTAL ATTIC SPACE: 2,973 SQ. FT 2,973 SQ. FT. / 300 SQ. FT. = 10.0 SQ. FT. 10.0 SQ. FT. / 2 (INTAKE/EXHAUST) = 5 SQ. FT. 5 SQ. FT. X 144 IN. = 720 SQ. IN. (NET FREE AREA REQUIRED) VENTILATION EXHAUST OPTIONS: ROOF LOUVER: B-144 ROUND METAL DOME VENT BY AIR VENT EQUALS 144 NFA PER PIECE: 720 SQ. IN / 144 NFA = 5 STATIC VENTS REQ'D. PROPOSED VENTILATION EXHAUST: 5 STATIC ROOF VENTS PROVIDED VENTILATION INTAKE CALCULATIONS: 720 SQ.IN. (NET FREE AREA REQUIRED - SEE ABOVE) AIR VENT UNDER EAVE VENT 16"X6" EQUALS 42 SQ.IN. NFA PER PIECE: 720 SQ.IN. / 42 NFA = 17.14 = 17 VENTS REQ'D. PROPOSED VENTILATION INTAKE: 17 VENTS PROVIDED Attic 'C' Ventilation Calculation: 1 SQ. FT. OF ATTIC VENT PER 300 SQ. FT. OF ATTIC FLOOR SPACE (OVER ALL PERIMETER OF ROOF) TOTAL ATTIC SPACE:12,162 SQ. FT 2,014 SQ. FT. / 300 SQ. FT. = 6.7 SQ. FT. 6.7 SQ. FT. / 2 (INTAKE/EXHAUST) = 3.35 SQ. FT. 3.35 SQ. FT. X 144 IN. = 482.4 SQ. IN. (NET FREE AREA REQUIRED) VENTILATION EXHAUST OPTIONS: ROOF LOUVER: B-144 ROUND METAL DOME VENT BY AIR VENT EQUALS 144 NFA PER PIECE: 482.4 SQ. IN / 144 NFA = 3.35 STATIC VENTS REQ'D. PROPOSED VENTILATION EXHAUST: 3 STATIC ROOF VENTS PROVIDED VENTILATION INTAKE CALCULATIONS: 482.4 SQ.IN. (NET FREE AREA REQUIRED - SEE ABOVE) AIR VENT UNDER EAVE VENT 16"X6" EQUALS 42 SQ.IN. NFA PER PIECE: 482.4 SQ.IN. / 42 NFA = 11.48 = 11 VENTS REQ'D. PROPOSED VENTILATION INTAKE: 11 VENTS PROVIDED Attic 'D' Ventilation Calculation: 1 SQ. FT. OF ATTIC VENT PER 300 SQ. FT. OF ATTIC FLOOR SPACE (OVER ALL PERIMETER OF ROOF) TOTAL ATTIC SPACE: 8,720 SQ. FT 2,206 SQ. FT. / 300 SQ. FT. = 7.35 SQ. FT. 7.35 SQ. FT. / 2 (INTAKE/EXHAUST) = 3.67 SQ. FT 3.67 SQ. FT. X 144 IN. = 529.2 SQ. IN. (NET FREE AREA REQUIRED) VENTILATION EXHAUST OPTIONS: ROOF LOUVER: B-144 ROUND METAL DOME VENT BY AIR VENT EQUALS 144 NFA PER PIECE: 529.2 SQ. IN / 144 NFA = 3.67 STATIC VENTS REQ'D. PROPOSED VENTILATION EXHAUST: 4 STATIC ROOF VENTS PROVIDED VENTILATION INTAKE CALCULATIONS: 529.2 SQ.IN. (NET FREE AREA REQUIRED - SEE ABOVE) AIR VENT UNDER EAVE VENT 16"X6" EQUALS 42 SQ.IN. NFA PER PIECE: 529.2 SQ.IN. / 42 NFA = 12.6 = 13 VENTS REQ'D. PROPOSED VENTILATION INTAKE: 13 VENTS PROVIDED Attic 'E' Ventilation Calculation: 1 SQ. FT. OF ATTIC VENT PER 300 SQ. FT. OF ATTIC FLOOR SPACE (OVER ALL PERIMETER OF ROOF) TOTAL ATTIC SPACE: 2,241 SQ. FT 2,241 SQ. FT. / 300 SQ. FT. = 7.47 SQ. FT. 7.47 SQ. FT. / 2 (INTAKE/EXHAUST) = 3.73 SQ. FT. 3.73 SQ. FT. X 144 IN. = 537.8 SQ. IN. (NET FREE AREA REQUIRED) VENTILATION EXHAUST OPTIONS: ROOF LOUVER: B-144 ROUND METAL DOME VENT BY AIR VENT EQUALS 144 NFA PER PIECE: 537.8 SQ. IN / 144 NFA = 3.73 STATIC VENTS REQ'D. PROPOSED VENTILATION EXHAUST: 4 STATIC ROOF VENTS PROVIDED VENTILATION INTAKE CALCULATIONS: 537.8 SQ.IN. (NET FREE AREA REQUIRED - SEE ABOVE) AIR VENT UNDER EAVE VENT 16"X6" EQUALS 42 SQ.IN. NFA PER PIECE: 537.8 SQ.IN. / 42 NFA = 12.8 = 13 VENTS REQ'D. PROPOSED VENTILATION INTAKE: 13 VENTS PROVIDED General Roof Plan Notes: 1. SEE CONSTRUCTION SPECIFICATIONS FOR FLASHING NOTES 2. FLASH ALL ROOF PENETRATIONS AS REQUIRED AND PER CODE 3. LOCATE ALL PLUMBING STACKS AT REAR ROOF PLANE. VERIFY THAT NO VENTS ARE VISIBLE FROM THE STREET 4.PROVIDE PRE-FIN. MTL. DRIP EDGE @ ALL ROOF EAVES AND RAKES 5.PROVIDE PRE-FIN. 6" ALUM. GUTTERS & DOWNSPOUTS (MECH. FASTENED) - COORD. DOWNSPOUT LOCATIONS W/OWNER & CIVIL ENG. IN FIELD 1.LOCATION OF DRAFTSTOPPING - VER. W/TRUSS MANUF. NOTE: DO NOT EXCEED 3,000 SQ.FT. OF ATTIC SPACE WITHOUT DRAFTSTOPPING - SEE DETAIL ON SHEET A.305 FOR ADDITIONAL INFORMATION 2.IF ROOF ABOVE GYM IS NOT OPEN TO MAIN ROOF STRUCTURE (ROOF #3) PROVIDE RIDGE VENT. OTHERWISE ALLOW VENTILATION TO PASS THROUGH TO MAIN ROOF ATTIC AND OUT THROUGH EXHAUST VENTS 3.A/C CONDENSING UNIT - VER. EXACT SIZE, LOCATION AND CLEARANCES W/MEP ENGINEER 4.LINE OF EXTERIOR WALL BELOW (TYP.) 5.PROVIDE GRACE ICE & WATER SHIELD @ ALL EAVES & VALLEYS 36" PAST THE INTERIOR OF THE EXTERIOR WALL AND UP EACH VALLEY SIDE 18" (MIN.) 6.ASPHALT SHINGLES ROOF (TYP.) 7.PROVIDE FULL GRACE ICE & WATER SHIELD @ ALL DORMERS (TYP.) 8.EXTEND GRACE ICE & WATER SHIELD UP ADJACENT WALL 18" (MIN.) 9.TYP. O.H. FOR ALL HIPS (U.N.O.) - SEE WALL SECTIONS 10.TYP. RAKE PROJECTION (U.N.O.) 11.TYP. O.H. FOR ALL DORMERS (U.N.O.) 12.AIRVENT: B-144 METAL DOME VENT - INSTALL PER MANUF. SPECS. VENTS MUST BE INSTALLED PER IBC 1203.2 (TYP.) - PAINT TO MATCH ROOF 13.SINGLE-PLY 60 MIL. EPDM W/PREFIN. METAL EDGE FLASHING W/DRIP EDGE - INSTALL IN STRICT COMPLIANCE W/MANUF. INSTALLATION SPECS. MIN. SLOPE 1/4" PER FOOT 14.OUTLINE OF MECHANICAL EQUIPMENT PLATFORM- RM. 201 Keyed Roof Plan Notes:X ATTIC AATTIC 'B'ATTIC 'D'ATTIC 'E'ATTIC 'C' 14 1 04/20/18 A.105 FINISH PLAN JCRCScale: 3/16" = 1'-0" Equipment Platform Finish Plan Scale: 1-1/2" = 1'-0" Chair Rail Detail Scale: 1/4" = 1'-0" Typ. Int. Elev. @ Infant Scale: 1/4" = 1'-0" Typ. Int. Elev. @ Classrooms CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT FINISH PLAN 3/16"=1'-0" Pre-School 2 Pre-K 2 Staff Lounge Pre-K 1 Pre-School 1 Laundry Rm. Varsity Room Corridor 1 Toddler 1 Gym Infant 1Infant 2 Young Pre-School Central Corridor Vestibule Childs Toilet 4 Childs Toilet 3 Child Toilet 5 Childs Toilet 7 Childs Toilet 9 Childs Toilet 8 Toddler 2 Childs Toilet 6 Gym Child ToiletCloset Gym Equip.Gym Equip. Directors Office Car Seat Sto. Utility Rm. Kitchen Pantry Kitchen Outdoor Toy Storage Closet Adult B.F. Toilet 1 Stair Child Toilet 2 Lobby Reception Conf.Rm. Closet 109 110 134 135 136 138 113 112 132 128 106 108 104 125 124 122 118 102 126 129123 101 100111 117 116 115 114 121 120 127 133 103 105 107 119 139 137 140 Hall 131 I.T. Closet 130 141 REF.FREEZ.FUTURE REF. PREP SINK HAND SINK D1 D4 D1 D1 F1 B2 P11 F3 F3 WJ1 WJ1 F3 B2 P6 D3 D2 CT4C2 CT4C2 F1 B2 P11 F1 B2 P11 WF2D1 F1 B2 P11 B2 CT2 CT1 F3 WJ1 WJ2 F3 F5 WJ1 P10 ABOVE CHAIR RAIL P10 ABOVE CHAIR RAIL P11 BELOW CHAIR RAIL F3 F2 F3 F2 B1 P1 P1 TYP. F2 F4 C1 CT3 F4 F3 D1D1 F4 F3 F4 F2 C1 CT3 B1 P1 P1 TYP. P11 C2 CT4 B2 F1 WF2 D1 C2 CT4 WF2 B2 D1 P11F1 C2 CT4 C2 CT4 WF2 B2 D1 P11F1 C2 CT4 F3 F1 F3 F1 C2 CT4 C2 CT4 F1 F1 WF2 B2 D1 P11F1 WF1 WF1 D1D1D1 D1 D1 D1 D1 D1 D1 D1 D1 D6 D1 C1 CT3 C1 CT3 C2 CT4 C2 CT4F3 B2 F3 F1 F4 F2 F4 F2 F1 F3 F1 F3 C2 CT4 C2 CT4 WJ1 WJ1 F1 F3 F1 F3 F3F3 F1 WF2 D1 P11 F1 D1 WF2 B2P11F1 D1 WF2 B2 P11F1 P11 B2 F4 F2 F2 F4 F2 F4 C1 CT3 C1 CT3 C1 CT3 C1 CT3 C1 CT3 D3D2D3D2 D3 D2 D3 D3 D6 D6 B3 F5 P11 B1 P1 B2 WF2 B1 P11 F2 F3 F1 D1 F3 B2 F6 C2 CT4 WF1 D2 D3 D2 D3 D3D2 D3 D2 D2 WJ1 WJ2B1P11F1 WF2 D3 D2 P8 B2 P3 B1 P7 B2 B2 P7 F1 B2 WF1 B2F2P11B2F2P11 F1 B2 P11 F1 B2 P11 D5 F3 B2 P11 WJ1 WJ1 WJ1 WJ1 P11B2 F1 C2 CT4 P6B2 F1 D1 C3 C3 P11 BELOW CHAIR RAIL P4 D1 D1 B2 P6 P10 ABOVE CHAIR RAIL P11 BELOW CHAIR RAIL F3 F3 F3 F3 B2 P1 F3 WJ1 WJ1 WJ1 C1 CT3 WJ1 D1 B2 F3 P11 WJ1 F3B2P6F1F3 DESCRIPTION F3 F2 BEHR 560C-3 HOLIDAY ROAD SHERWIN WILLIAMS: CUSTOM MATCH B20W2651- COLORANT: Y1 Y3P1 SHERWIN WILLIAMS B20W2651 BEHR 580-3 IMPRESSION SKY MANUFACTURER P8 SW 1206 MOON RIVER SHERWIN WILLIAMS: CUSTOM MATCH B20W2651 - COLORANT: W1 L1 R3 Y1 SHERWIN WILLIAMS B2W2651 P7 WJ2 D1 D6 DOOR JAMB = WHITE (H.M.) SHERWIN WILLIAMS SAFETY BLUE DOOR JAMB = RED (H.M.) F SYMBOL FINISH / COLOR WJ1 WJ WHITE JAMB WINDOW JAMBS (1) COAT PRIMER W/ (2) COATS PAINT RED JAMB FLOORS F1 P PAINTS BEHR 340E-2 COTTONSEED P2 F4 SHERWIN WILLIAMS: CUSTOM MATCH B20W2651 - COLORANT: L1 R3 Y1 MANUFACTURER P4 P3 SHERWIN WILLIAMS B20W2651 SHERWIN WILLIAMS: CUSTOM MATCH B20W2651 - COLORANT: L1 N1 R3 FINISH / COLORDESCRIPTIONSYMBOL (1) COAT PRIMER W/ (2) COATS PAINT SW-2234 MEMORY LANE P5 SW-6519 HINTING BLUE P9 SHERWIN WILLIAMS B20W2651 WHITE WALL PACKAGE EXTRA WHITE UL 220-2 VOYAGE P6 RAINBOW WHITE P10 SW 6520 HONEST BLUE D5 F6 F5 DOOR EXTERIOR = BLUE D4 DOOR INTERIOR = WHITE D3 DOOR JAMB = RED (H.M.) DOORS & DOOR JAMBS COLORS DOOR JAMB INT. = WHITE DOOR INTERIOR = RED D2 D EXTERIOR DOOR DOOR WOOD PRE-FINISHED (MAPLE) SHERWIN WILLIAMS PRO CLASSIC WATER BORN SEMI-GLOSS DOOR WOOD PRE-FINISHED (MAPLE) DOOR JAMB EXT. = BLUE DOOR WOOD PRE-FINISHED (MAPLE)INTERIOR DOOR EXTERIOR DOOR INTERIOR DOOR EXTERIOR DOOR DOOR JAMB = BLUE (H.M.) SHERWIN WILLIAMS SAFETY BLUE SHERWIN WILLIAMS INTERIOR DOOR INTERIOR WINDOW JAMBS B SHERWIN WILLIAMS NATURAL MAPLE BASE C1 B1 PL INTERIOR WINDOW JAMBS CABINETSC (APPROVED BY OWNER) C3 MAPLE FINISH CABINETS C2 PL1 FINISH SCHEDULE SHERWIN WILLIAMS SAFETY BLUE SHERWIN WILLIAMS SAFETY BLUE B3 B2 NATURAL MAPLE WHITE THERMOFOIL NO BASE (APPROVED BY OWNER) WHITE FINISH CABINETS CUSTOM CABINETS (APPROVED BY OWNER) F.R.P.: MARLITE (OR EQUAL) WF WALL FINISHES F.R.P. WALL FINISH TO CEILING F.R.P.: S100 G WHITE (CLASS A)WF1 NOTE: ALL INTERIOR WALLS TO RECEIVE EGGSHELL PAINT FINISH. ALL CEILINGS TO RECEIVE FLAT PAINT FINISH. PAINT ALL EXPOSED DUCT WORK TO MATCH CEILINGS (1) COAT PRIMER W/ (2) COATS PAINT (1) COAT PRIMER W/ (2) COATS PAINT (1) COAT PRIMER W/ (2) COATS PAINT (1) COAT PRIMER W/ (2) COATS PAINT (1) COAT PRIMER W/ (2) COATS PAINT (1) COAT PRIMER W/ (2) COATS PAINT (1) COAT PRIMER W/ (2) COATS PAINT (1) COAT PRIMER W/ (2) COATS PAINT (1) COAT PRIMER W/ (2) COATS PAINT SHERWIN WILLIAMS: CUSTOM MATCH B34W851 - COLORANT: L1 R3 P11 PLASTIC LAMINATE SHERWIN WILLIAMS B20W2651 SHERWIN WILLIAMS B20W2651 PLAS. LAM. HALF WALL @ RECEPTION AREA 7012-58 AMBER MAPLE OR 10734-60 LIMBER MAPLEFORMICA OR WILSON 7811 VERVE COLOR 18103 (ACADEMY) TOLI CPT (INSTALLED BY GC) MASLAND ROPPE 4" VINYL BASE - 1/8" V.C.T. SHEET VINYL (INSTALLED BY GC) STANDARD EXCELON IMPERIAL TEXTURE COLOR 51933 (BLUE CLOUD)ARMSTRONG FLOOR PAINT CLASSIC VERMONT MAPLE #772 GREY VINYL COVE BASE/TRANSITION MLDG PADDED SHEET VINYL (INSTALLED BY GC) CPT. (INSTALLED BY GC) MASLAND SIGNAFLEX MAPLE COLOR 139 (DEEP NAVY)VINYL COVE BASE/TRANSITION MLDG-S 7811 VERVE COLOR 18111 (BLUE RIBBON) ROPPE 4" VINYL BASE - 1/8" COLOR 632 (FLAX) SW-6190 FILMY GREEN F.R.P.: MARLITE (OR EQUAL)F.R.P. WALL FINISH TO 4'-0" A.F.F.F.R.P.: S100 G WHITE (CLASS C)WF2 X D2 D3 D2 D3 D2 D3 D6 5'-11 1/4"10'-3 7/8"8'-1 11/16"5'-11 1/4"21'-6 7/8"23'-9 7/8"21'-5 11/16"9'-11 3/8"8'-0 11/16"14'-11 3/8"7'-7 3/4"6'-4 3/4"8'-0"19'-2 1/4"11'-3 1/4" 19'-0 3/8"16'-11 1/4"16'-11 1/4"6'-10 3/8" 10'-6 3/8"10'-2 1/4" 6'-10 3/8" 10'-10 3/8" 11'-11 3/8" P11 1 COAT 12" PASTTYP.P10 BELOW CHAIR RAIL12"PASTTYP.12" PAST TYP. P11 ABOVE CHAIR RAIL 12" PAST TYP. WF1 WF112" PASTTYP.12" PAST TYP. WF1 WF1 12" PASTTYP.ZODIAQ BOREALIS BLUE CT2 CT COUNTER TOPS PLAS. LAM. COUNTER CT1 SOLID SURFACE COUNTER PLAS. LAM. COUNTER PLAS. LAM. COUNTERCT3 CT4 FORMICA LAMINATE WILSONART LAMINATE FINISH - 58 (MATTE) COLOR - 459 (BRITE WHITE) POST FORMED ROLL DRIP EDGE FINISH - 60 (MATTE) COLOR - 4166 (PAMPAS) POST FORMED ROLL DRIP EDGE WILSONART LAMINATE FINISH - 60 (MATTE) COLOR - 4142 (GREY GLACE) POST FORMED ROLL DRIP EDGE WF1 F.E. F.E. F.E.F.E. COMBO OVEN UNIT COMBO OVEN UNIT B2F3 B2F3B2F3 B3 NOTES: 1.CHAIR RAIL IS TO RUN ENTIRE PERIMETER OF CORRIDOR & ROOMS 100, 102, 124, & 125 2.FLOORING LEAD TIME IS 7 WEEKS FROM APPROVED OVER FORM AND TAKE OFF 3.G.C. TO PROVIDE THE GYM PAD MEASUREMENTS TO THE OWNER NO LATER THAN SEVEN (7) WEEKS BEFORE C/O. WF1 ULTRALITE SUPERCOAT MOULDING 956WWM (1/2" X 4-1/4") (SEE FINSIH SCHEDULE - P9)39" A.F.F. @INFANT RMS.ULTRALITE SUPERCOAT MOULDING 300M (1" X 3") (SEE FINISH SCHEDULE - P9)34.5" A.F.F. @CORRIDORULTRALITE SUPERCOAT MOULDING 956WWM (1/2" X 4-1/4") (SEE FINSIH SCHEDULE - P9)39" A.F.F. @INFANT RMS.ULTRALITE SUPERCOAT MOULDING 300M (1" X 3") (SEE FINISH SCHEDULE - P9)34.5" A.F.F. @CORRIDOR8'-0" CEILING HEIGHT56" A.F.F.GYP. BRD. (PAINT) 4" VINYL COVE BASE GYP. BRD. CLG. (PAINT) CHAIR RAIL - 39" A.F.F. INFANT 9" WALLPAPER BOARDS GYP. BRD. (PAINT) NOTES: SEE FINISH SCHEDULE & FINISH PLAN ON SHEET A.500 (1) PHONE JACK (2) LIGHT SWITCH 39"Equipment Platform 201 Attic 'B' F6 P11 2018'-0" CEILING HEIGHT56" A.F.F.GYP. BRD. (PAINT) 4" VINYL COVE BASE GYP. BRD. CLG. (PAINT) GYP. BRD. (PAINT) NOTES: SEE FINISH SCHEDULE & FINISH PLAN ON SHEET A.500 (1) PHONE JACK (2) LIGHT SWITCH CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.200 EXTERIOR ELEVATIONS JCRC 3'-0" D A.301 G A.302 1 FRONT (EAST) ELEVATION 3/16"= 1'-0" 2 1 6 2 3 3 6 6 M-1 M-1 M-1 M-2 M-4 M-2 M-9 M-9 M-6 M-5 M-8 M-8 5 12 5 12 5 12 M-2 12 E A.301 C A.300 F A.301 A A.300 H A.302 2 LEFT (SOUTH) ELEVATION 3/16"= 1'-0" 1 1 222 33 44 6 6 M-1M-1M-1 M-9M-9M-9M-9 M-4 M-6 M-8 5 12 5 12 5 12 5 12 M-5 7 M-2 8888 3 7 General Elevation Notes: 1). ALL TRIM BOARDS (U.N.O.) WILL BE CLAD IN PRE-FIN. ALUM. - DETERMINE GAUGE PER RAINBOW CHILD CARE CENTER SPEC'S. 2). EXTERIOR BRICK IS TO BE STANDARD SIZE - COURSE OUT QUOIN CORNERS 3). EXTERIOR WINDOWS ARE JELDWEN. THEY ARE OPERABLE AND HAVE SCREENS. SCREENS ARE TO BE 16 MESH OR BETTER. 4). DO NOT SCALE HATCHING. REFER TO BUILDING SECTIONS & WALL SECTIONS FOR PROPER CONSTRUCTION METHODS. A.300 - A.305 5). SIGNAGE TO BE INSTALLED BY G.C. AS DIRECTED BY OWNER Exterior Elevation Materials ITEM MANUFACTURER MODEL COLOR / FINISH NOTES BRICK ASPHALT SHINGLES BREAK METAL TRIM COLOR - 807 (CLAY) BRAMPTON BRICK NOTE: JELD-WEN WINDOWS TO BE PRE-FINISHED W/DESERT SAND STONE VENEER COLOR - JASPER IF BRICK IS NOT READILY AVAILABLE PROVIDE OPTIONS FOR OWNER TO APPROVE VINYL SIDING CERTAINTEED CORPORATION DOUBLE 5" CLAPBOARD CROSSROADS SERIES MIST - QUALITY EDGE TRULINE EMBOSSED TRIM COIL - GAF ROOFING COLOR - WEATHERED WOOD -TIMBERLINE HD - LIFETIME SHINGLES - - PRE-FIN ALUMINUM GUTTER MASTIC HOME EXTERIORS 6" GUTTER COIL - 27 GAUGE COLOR - PEBBLESTONE CLAY (VERIFY W/OWNER) VER. W/ OWNER FOR MANUFACTURER, MODEL, AND COLOR SILLS T.B.D.LIMESTONE VARIEGATED SYMBOL M-1 M-2 M-3 M-4 M-5 M-6 M-7 X-x -CEDAR TRIM BOARD CEDAR NATURAL & SEALEDM-8 - --- SPLITFACE C.M.U.MICHIGAN CERTIFIED CONCRETE SPLIT FACED VAOLS IF BLOCK IS NOT READILY AVAILABLE PROVIDE OPTIONS FOR OWNER TO APPROVE M-9 1.TYPICAL EAVE - SEE DETAIL FOR MORE INFORMATION 2.BRICK SOLDIER COURSE (TYP.) 3.SILL SLOPED TO ALLOW WATER RUNOFF WITH DRIP EDGE 4.1X2 TRIM BRD. ON 1X6 RAKE BRD. ON 1X6 SUB-RAKE BRD. WITH PRE-FINISHED ALUMINUM WRAP 5.1/2" AZTEK PANEL (PAINT) 6.PRE-FINISHED ALUMINUM GUTTER AND DOWNSPOUT - VERIFY CONNECTION DETAIL AND LOCATION WITH CIVIL ENGINEER 7.PROVIDE LOUVERED DORMERS FOR MECHANICAL INTAKE(VER. W/ MECH. DRAWINGS) 8.LINE OF DRAFT STOPPING 9.LINE OF BUILDING BEYOND 10.CONDENSING UNIT. SEE MECH. DRAWINGS FOR EXACT LOCATIONS 11.60MIL EPDM ROOF FULLY ADHERED 12.PROPOSED 81" X 30" SIGN SHOWN. SIGN TO BE PERMITTED UNDER SEPARATE SUBMITTAL BY SIGN VENDOR. Keyed Elevation Notes:X CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.201 EXTERIOR ELEVATIONS JCRC 3'-0" 2'-10" E A.301 C A.300 F A.301 A A.300 H A.302 2 RIGHT (NORTH) ELEVATION 3/16"= 1'-0" 2 1 2 3 6 6 3 4 4 M-1 M-1 M-1 M-1 M-2 M-2M-2 M-4 M-4 M-9 M-9 M-9 M-5 2 M-8 1010 5 12 5 12 5 12 5 12 M-2 11 8 88 8 M-4 3'-0" G A.302 D A.301 1 REAR (WEST) ELEVATION 3/16"= 1'-0" 1 11 2 2 3 3 4 6 M-1 M-1 M-5 M-5M-5 M-2 M-2 M-4 M-6 10 5 5 12 5 12 M-2 General Elevation Notes: 1). ALL TRIM BOARDS (U.N.O.) WILL BE CLAD IN PRE-FIN. ALUM. - DETERMINE GAUGE PER RAINBOW CHILD CARE CENTER SPEC'S. 2). EXTERIOR BRICK IS TO BE STANDARD SIZE - COURSE OUT QUOIN CORNERS 3). EXTERIOR WINDOWS ARE JELDWEN. THEY ARE OPERABLE AND HAVE SCREENS. SCREENS ARE TO BE 16 MESH OR BETTER. 4). DO NOT SCALE HATCHING. REFER TO BUILDING SECTIONS & WALL SECTIONS FOR PROPER CONSTRUCTION METHODS. A.300 - A.305 5). SIGNAGE TO BE INSTALLED BY G.C. AS DIRECTED BY OWNER Exterior Elevation Materials ITEM MANUFACTURER MODEL COLOR / FINISH NOTES BRICK ASPHALT SHINGLES BREAK METAL TRIM COLOR - 807 (CLAY) BRAMPTON BRICK NOTE: JELD-WEN WINDOWS TO BE PRE-FINISHED W/DESERT SAND STONE VENEER COLOR - JASPER IF BRICK IS NOT READILY AVAILABLE PROVIDE OPTIONS FOR OWNER TO APPROVE VINYL SIDING CERTAINTEED CORPORATION DOUBLE 5" CLAPBOARD CROSSROADS SERIES MIST - QUALITY EDGE TRULINE EMBOSSED TRIM COIL - GAF ROOFING COLOR - WEATHERED WOOD -TIMBERLINE HD - LIFETIME SHINGLES - - PRE-FIN ALUMINUM GUTTER MASTIC HOME EXTERIORS 6" GUTTER COIL - 27 GAUGE COLOR - PEBBLESTONE CLAY (VERIFY W/OWNER) VER. W/ OWNER FOR MANUFACTURER, MODEL, AND COLOR SILLS T.B.D.LIMESTONE VARIEGATED SYMBOL M-1 M-2 M-3 M-4 M-5 M-6 M-7 X-x -CEDAR TRIM BOARD CEDAR NATURAL & SEALEDM-8 - --- SPLITFACE C.M.U.MICHIGAN CERTIFIED CONCRETE SPLIT FACED VAOLS IF BLOCK IS NOT READILY AVAILABLE PROVIDE OPTIONS FOR OWNER TO APPROVE M-9 1.TYPICAL EAVE - SEE DETAIL FOR MORE INFORMATION 2.BRICK SOLDIER COURSE (TYP.) 3.SILL SLOPED TO ALLOW WATER RUNOFF WITH DRIP EDGE 4.1X2 TRIM BRD. ON 1X6 RAKE BRD. ON 1X6 SUB-RAKE BRD. WITH PRE-FINISHED ALUMINUM WRAP 5.1/2" AZTEK PANEL (PAINT) 6.PRE-FINISHED ALUMINUM GUTTER AND DOWNSPOUT - VERIFY CONNECTION DETAIL AND LOCATION WITH CIVIL ENGINEER 7.PROVIDE LOUVERED DORMERS FOR MECHANICAL INTAKE(VER. W/ MECH. DRAWINGS) 8.LINE OF DRAFT STOPPING 9.LINE OF BUILDING BEYOND 10.CONDENSING UNIT. SEE MECH. DRAWINGS FOR EXACT LOCATIONS 11.60MIL EPDM ROOF FULLY ADHERED 12.PROPOSED 81" X 30" SIGN SHOWN. SIGN TO BE PERMITTED UNDER SEPARATE SUBMITTAL BY SIGN VENDOR. Keyed Elevation Notes:X Partial Building Section Scale: 1/4" = 1'-0" C A.300 NOTE: 1. PROVIDE DRAFTSTOPPING AS REQUIRED BY CODE IN ATTIC SPACE (SEE ROOF PLAN SHEET A-104 & DETAIL SHEET A-305). 2. FIRESTOPPING SHALL BE INSTALLED PER CODE 3. THE INTEGRITY OF ALL FIRESTOPPING AND DRAFTSTOPPING SHALL BE CONTINUOUSLY MAINTAINED. 4. FIRESTOPPING SHALL OCCUR AT ALL INTERSECTIONS BETWEEN VERTICAL AND HORIZONTAL SPACES PER CODE Building Section Scale: 1/4" = 1'-0" A A.300 CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.300 BUILDING SECTIONS JCRC Partial Building Section Scale: 1/4" = 1'-0" B A.300 CONCRETE SLAB (SEE STRUCT.) GIRDER TRUSS GIRDER TRUSS Utility. Rm. Attic Kitchen Attic Reception Gym Lobby CONC.FOUND. WALL (SEE STRUCT.) 8'-0" ROOF LINE IN FOREGROUND 5/8" DRYWALL (3) LVL BEAM SEE STRUCTURALLVL BEAM (FLUSH) SEE STRUCTURAL. JOISTS W/ HANGERS 2X6 @ 16" 0.C. JOISTS W/ HANGERS HEADER SEE STRUCTURAL CEILING @ DIRECTOR'S OFFICE BEYOND FOUNDATION BEYOND. SEE FOUNDATION PLAN. GIRDER TRUSS (1) LAYER 5/8" TYPE -X GYPSUM BD. (1) LAYER 5/8" TYPE -X GYPSUM (TYPICAL) 44'-8" 3'-0"9'-0"12'-0"12'-0"Gym Equip. (R-38) BLOWN-IN INSULATION (R-38) BLOWN-IN INSULATION (R-38) BLOWN-IN INSULATION 6'-10 3/8" ±COORDINATE W/ WINDOWSCONSTRUCTION OF LID OVER STORAGE TO SLOPE TO THE FRONT FOUNDATION BEYOND. SEE FOUNDATION PLAN.6'-8 3/8" ±(R-38) BATT INSULATION (R-38) BATT INSULATION8'-1 1/8"CONCRETE SLAB (SEE STRUCT.) CONC. FOUND. (SEE STRUCT.) Pre-K 2Varsity Room 3/4" F.R.T. PLYWD. SUBFLOOR (SEE STRUCTURAL) 1 LAYER OF 5/8" GYP. BD. Attic Attic Attic 12 5 12 5 Equipment Platform PLATE HGT.(TYPICAL)(1) LAYER 5/8" TYPE -X GYP. BD. INTERIOR WALL: 5/8" GYP. BD.. (EACH SIDE) ON 2X4 WOOD STUDS @ 16" O.C. U.N.O. 3'-3 5/8" 9'-5 7/8"9'-5 7/8" 5 1/2" 6'-0" 5 1/2" DORMER BEYOND (TYPICAL) METAL FLASHING 8'-6"8'-6" Corridor 1 PRE-ENG. GIRDER TRUSS. W/ HIGH BOTTOM CHORD. (SEE STRUCT.)9'-2"11 1/4"8'-2 3/4"8'-1 1/8" PLATE HGT.'QUIET BATT' SOUNDPROOFING INSULATION (TYP. BELOW MECH. ROOM FLOOR) (R-38) BLOWN-IN INSULATION PRE-ENG ROOF TRUSSES (SEE STRUCT.) PRE-ENG ROOF TRUSSES (SEE STRUCT.) PRE-ENG ROOF TRUSSES (SEE STRUCT.) (R-38) BLOWN-IN INSULATION (R-38) BLOWN-IN INSULATION 5 1/2" Child Toilet 7 8'-6 5/8" DOOR LANDING BEYOND 5 A.303 INSULATION BAFFLE 8'-1 1/8"CONCRETE SLAB (SEE STRUCT.) Pre-School 2 3/4" F.R.T. PLYWD. SUBFLOOR (SEE STRUCTURAL) 1 LAYER OF 5/8" GYP. BD. Attic Attic 12 5 Equipment Platform (1) LAYER 5/8" TYPE -X GYP. BD. INTERIOR WALL: 5/8" GYP. BD. (EACH SIDE) ON 2X4 WOOD STUDS @ 16" O.C. U.N.O. 3'-3 5/8" 9'-5 7/8"4'-0 7/8" 5 1/2" 6'-0" 3 5/8" STAIRS TO EQUIPMENT PLATFORM. REFER TO SHEET A-305. Corridor 1 PRE-ENG. GIRDER TRUSS. W/ HIGH BOTTOM CHORD. (SEE STRUCT.)9'-2"11 1/4"8'-2 3/4" PLATE HGT.'QUIET BATT' SOUNDPROOFING INSULATION (TYP. BELOW MECH. ROOM FLOOR) PRE-ENG ROOF TRUSSES (SEE STRUCT.)9'-1 1/4"16 RISERS AT 6-13/16" EACHPRE-ENG ROOF TRUSSES (SEE STRUCT.) PRE-ENG ROOF TRUSSES (SEE STRUCT.) (R-38) BLOWN-IN INSULATION (R-38) BLOWN-IN INSULATION Attic Young Pre-School DOOR LANDING (R-38) BLOWN-IN INSULATION Building Section Scale: 1/4" = 1'-0" F A.301 Partial Building Section Scale: 1/4" = 1'-0" D A.301 Partial Building Section Scale: 1/4" = 1'-0" E A.301 NOTE: 1. PROVIDE DRAFTSTOPPING AS REQUIRED BY CODE IN ATTIC SPACE (SEE ROOF PLAN SHEET A-104 & DETAIL SHEET A-305). 2. FIRESTOPPING SHALL BE INSTALLED PER CODE 3. THE INTEGRITY OF ALL FIRESTOPPING AND DRAFTSTOPPING SHALL BE CONTINUOUSLY MAINTAINED. 4. FIRESTOPPING SHALL OCCUR AT ALL INTERSECTIONS BETWEEN VERTICAL AND HORIZONTAL SPACES PER CODE CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.301 BUILDING SECTIONS JCRC8'-1 1/8"CONCRETE SLAB (SEE STRUCT.) 12 12 5 5 Toddler 1Infant 1 Attic Central Corridor PLATE HGT.(TYPICAL)12'-0" CEILING HGT.(TYPICAL THRU-OUT CENTRALCORRIDOR "OCTAGON")INTERIOR WALL W/ 5/8" GYPSUM BD. SEE STRUCTURAL PLANS FOR BEARING POINTS 87'-6" (OUTSIDE TO OUTSIDE OF 2x6 WOOD STUD WALLS) 33'-10 5/8"34'-3 5/8"19'-3 3/4" (WOOD STUD TO WOOD STUD)8'-1 1/8"PLATE HGT. (TYPICAL)8'-6"8'-6" (1) LAYER 5/8" TYPE -X GYPSUM BD. 'STO' STO GUARD DAMP PROOFING MINIMUM 6" BELOW TOP OF FOOTING. TYPICAL @ ALL C.M.U. BELOW GRADE CONC. FOUND. (SEE STRUCT.)CONC. FOUND. (SEE STRUCT.)9'-0"SPRING POINT FOR CATHEDRALCEILING IN LOBBY ONLYLINE OF CATHEDRAL CEILING IN LOBBY ONLY 4068 OPENING TO CORRIDOR (R-38) BLOWN-IN INSULATION (R-38) BLOWN-IN INSULATION (R-38) BLOWN-IN INSULATION PRE-ENG ROOF TRUSSES (SEE STRUCT.) PRE-ENG ROOF TRUSSES (SEE STRUCT.) PRE-ENG ROOF TRUSSES (SEE STRUCT.) (R-21) BATT INSULATION W/ 3" ALUMINUM FOIL FACE POLYISO. RIGID INSULATION ALTERNATIVE: PROVIDE BATT INSULATION TO A TOTAL OF R-38. ALTERNATIVE: PROVIDE BATT INSULATION TO A TOTAL OF R-38. (R-21) BATT INSULATION W/ 3" ALUMINUM FOIL FACE POLYISO. RIGID INSULATION12'-0"8'-1 1/8"8"EXISTING GRADE Attic Gym PLATE HGT. PLATE HGT. CONCRETE SLAB (SEE STRUCT.) 2x6 STUD WALL INBETWEEN WOOD TRUSSES3'-10 7/8"EXTEND TRUSS TOP CHORD 2x CONTINUOUS WD. PLATES AS REQID. 60 MIL E.P.D.M ROOFING W/ PREFINISHED METAL EDGE FLASHING W/ DRIP EDGE (SEE ROOF PLAN, SHEET A.104) ON 3/4" ISO 3 RIGID ROOF INSULATION (INSTALLED PER MANUF. INSTALLATION & DETAILS) ON 3/4" APA RATED EXTERIOR PLYWOOD SHEATHING ON 2x6 @ 16" O.C. FRAMING. 2x12 CONTINUOUS PLATE NAILED TO TRUSSES FLASHING ON ALL SIDES OF SADDLE PER ROOF'G MANUF. DETAILS & SPEC. CONC. FOUNDATION (SEE STRUCT.) CONC. FOUND. (SEE STRUCT.) 'GRACE' PERMA-BARRIER THRU-WALL FLASHING W/ WEEP HOLES @ 32" O.C. & MIN. 3" LAYER PEA GRAVEL ON TOP OF FLASH'G. GROUT AIR SPACE SOLID BELOW FLASH'G VARIES(R-38) BLOWN-IN INSULATION 12 5 ASPHALT ROOF SHINGLES ON MIN. 30 # FELT PAPER ON 1/2 APA RATED EXT. PLYWOOD SHEATHING ON PRE-ENGINEERED ROOF TRUSSES 4'-0" INSULATION BAFFLE (2" MIN.) VENEER STONE ON 1" AIRSPACE ON 1/2" PLYWOOD ON 2X6 STUD ON STEEL COLUMN (SEE STRUCTURAL DWGS) ADD BLOCKING AS REQUIRED TO PACK OUT TO SPEC'D DIM.2'-8"9'-0 3/4" ± V.I.F.1'-8"2" LIMESTONE CAP SLOPE FOR WATER RUN OFF 3/4" CEDAR TRIM ON WOOD BLOCKING ON STEEL COLUMN 1'-6" SEE STRUCTURAL DETAIL. FULLY VENTED ALUM. SOFFIT ON BOTTOM CHORD OF TRUSSES Building Section Scale: 1/4" = 1'-0" H Building Section Scale: 1/4" = 1'-0" G A.302 A.302 CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.302 BUILDING SECTIONS JCRC NOTE: 1. PROVIDE DRAFTSTOPPING AS REQUIRED BY CODE IN ATTIC SPACE (SEE ROOF PLAN SHEET A-104 & DETAIL SHEET A-305). 2. FIRESTOPPING SHALL BE INSTALLED PER CODE 3. THE INTEGRITY OF ALL FIRESTOPPING AND DRAFTSTOPPING SHALL BE CONTINUOUSLY MAINTAINED. 4. FIRESTOPPING SHALL OCCUR AT ALL INTERSECTIONS BETWEEN VERTICAL AND HORIZONTAL SPACES PER CODE 8'-1 1/8"ASPHALT ROOF SHINGLES ON MIN. 30 # FELT PAPER ON 1/2 APA RATED EXT. PLYWOOD SHEATHING ON PRE-ENGINEERED ROOF TRUSSES CONCRETE SLAB (SEE STRUCT.) CONC. FOUND. (SEE STRUCT.) Pre - K1 Attic 12 5 12 5 (1) LAYER 5/8" TYPE - X GYPSUM BD Pre-School 1 58'-1" (OUTSIDE TO OUTSIDE OF 2X6 WOOD STUD WALLS) Corridor 1INTERIOR WALL: 5/8" TYPE X GYPSUM BD. (EACH SIDE) ON 2X4 WOOD STUD FRAMING @ 16" O.C. UNLESS NOTED OTHERWISEPLATE HGT. (TYPICAL)PRE-ENG ROOF TRUSSES (SEE STRUCT.) PRE-ENG ROOF TRUSSES (SEE STRUCT.) THICKENED SLAB (SEE STRUCT.)12'-0"9'-0"Lobby CONC.FOUND. (SEE STRUCT.) Vestibule Central Corridor 12'-0"8'-0"132 101111 133 12 5 12 5 12 5 11'-5"ASPHALT ROOF SHINGLES SPRING POINT FOR CATHEDRAL CEILING - REFER TO SECTION 3 7'-2"4068 OPENING (R-38) BLOWN-IN INSULATIONPRE-ENG ROOF TRUSSES (SEE STRUCT.) PRE-ENG ROOF TRUSSES (SEE STRUCT.) (R-38) BLOWN-IN INSULATION Corridor EXTERIOR GRADE 12 5 ASPHALT ROOF SHINGLES ON MIN. 30 # FELT PAPER ON 5/8" APA RATED EXT. PLYWOOD SHEATHING ON PRE-ENGINEERED ROOF TRUSSES 3'-0" (R-38) BLOWN-IN INSULATION CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.302.1 BUILDING SECTIONS JCRC Wall Mat Detail at Gym Scale: 1 1/2" = 1'-0" Typ. Single-hung Window Head2 A.302.1 Typ. Single-hung Window Jamb Scale: 3" = 1'-0" Typ. Single-hung Window Sill Scale: 3" = 1'-0" 4 A.302.1 1 A.302.1 3 A.302.1 2 X 10 SOLID BLOCKING BETWEEN STUDS F/A PULL BOXES SWITCHES, OUTLETS BOT @ 46" A.F.F. (NOTCH BLOCKING AS REQUIRED) NOTE: POTENTIAL CONFLICT WITH SWITCHES OUTLETS AND PULL STATIONS AND ADA HT. 42" or 46" WALL MATS BY OWNER BRICK ROWLOCK COURSE BEYOND SINGLE HUNG VINYL WINDOW WITH 1" INSULATING GLASING AND NAILING FIN. BRICK STACK BOND BEYOND PRE-FINISHED BRAKE METAL FLASHING UP AND IN FRONT OF NAILING FIN PRE-FINISHED BRAKE METAL TRIM PRE-FINISHED BRAKE METAL TRIM 2X SOFFIT FRAMING 1X4 TRIM BOARD 1X10 FRIEZE BOARD 2X FRAMING RIPPED FROM 2X6 TO FLUSH-OUT WITH FACE OF BRICK. TRUSS ANCHOR SEE STRUCTURAL 1/2" EXTERIOR SHEATHING - EXTEND TO U/S OF TRUSS TOP CHORD. 2X HEADER SEE STRUCTURAL 2X6 WALL FRAMING WITH DBL. TOP PLATE. 5/8" GYP. BOARD BACKER ROD AND SEALANT FULL-ROUND 2X6 WALL FRAMING WITH DBL. TOP PLATE. REFER TO STRUCTURAL FOR MULTIPLE STUD PACK LOCATIONS 5/8" GYP. BOARD BRICK STACK BOND RETURNS AT WINDOWS BRICK VENEER - RUNNING BOND IN FIELD. BACKER ROD AND SEALANT FULL ROUND SINGLE HUNG VINYL WINDOW W/ 1"INSULATING GLASS CAST STONE SILL/WATERTABLE BELOW SEALANT FULL ROUND CORIAN WINDOW SILL WITH RADIUSED NOSE AND CORNERS - CONFIRM WITH OWNER BATT INSULATION REFER TO WALL TYPE SINGLE HUNG VINYL WINDOW W/ 1"INSULATING GLASS CORIAN WINDOW SILL WITH RADIUSED NOSE AND CORNERS - CONFIRM WITH OWNER SEALANT FULL ROUND BRICK STACK BOND RETURNS AT WINDOWS PRE-FINISHED BREAK METAL FLASHING SET IN FULL BED OF SEALANT ON PT WOOD CANT SHIM, HEM FLASHING END BACKER ROD AND SEALANT THRU WALL METAL FLASHING UP AND IN FRONT OF FIN. HEM FLASHING END MORTAR NET WEEPS AT 16" O.C. FLEXIBLE THRU WALL FLASHING SPLIT-FACE CMU REFER TO ELEVATIONS FOR MATERIAL AND COLOR DESCRIPTION. SEE WALL TYPES FOR TYPICAL MATERIALS. NOMINAL 4" CAST STONE SILL/WATERTABLE WITH MFR'S RECOMMENDED ANCHORS INSTALL PER MFR'S INSTRUCTIONS BACKER ROD AND SEALANT FULL ROUND Section Thru H.M. Door Jamb Scale: 1-1/2" = 1'-0" Typical Wall Section Scale: 3/4" = 1'-0" Typical Wall Section Thru Window Scale: 3/4" = 1'-0" Typical Wall Section Thru Exterior Door Scale: 3/4" = 1'-0" 1 2 3 A.303 4 A.303 A.303 CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.303 WALL SECTIONS JCRC Typical Equipment Platform Wall Section Scale: 3/4" = 1'-0" 5 A.303 A.303 Typical Equipment Platform Wall Plan Scale: 1 1/2" = 1'-0" 6 A.303 1/2" EXPANSION JOINT MATERIAL (2) 2X HEADER. SEE STRUCT. H.M. JAMB (BEYOND-PAINT) ALUMINUM THRESHOLD H.M. DOOR (PAINT) H.M. JAMB (BEYOND-PAINT) BACKER ROD / CAULK LINE OF BRICK (BEYOND)6'-10" R.O.1/4 : 12 PITCH 3'-0"8'-1 1/4"CONC. SLAB RIGID INSUL. (SEE STRUCT.) (R-38) BLOWN-IN INSULATION4 A.303 FULLY VENTED ALUMINUM SOFFIT ON 2x4 FRAMING @ 24" O.C. (3) #5 CONT. (BOTTOM) 6" 3"3"CARDBOARD INSULATION BAFFLE BEYOND @ 48" O.C. TURN OUT FLANGES AND NAIL TO U/S OF TOP CHORD AND HORIZONTAL 2X6 BLOCKING NOTE: MINIMUM FREE AIR AREA - 3 12" X 2 2 12" @ 48" O.C. 2'-9" 12 5 SHEATHING STOPS AT U/S OF TOP CHORD BRICK VENEER W/ BRICK TIES PER CODE ON MIN. 1" AIR SPACE 1/2" APA RATED PLYWOOD SHEATHING ON 2X6 WOOD STUDS BACKER ROD/CAULK H.M. DOOR H.M. DOOR JAMB-ANCHOR TO WOOD FRAMING PER MANUF. INSTRUCTION 5/8" GYPSUM BD. ALUMINUM THRESHOLD (BELOW) 4" THK. LIMESTONE SILL W/ SLOPED TOP BELOW. PRE-FIN. ALUM. CLAD 2x8 (CUT TOP) FASCIA FULLY VENTED ALUMINUM SOFFIT ON 2x4 FRAMING @ 24" O.C. PRE-FINISHED METAL DRIP EDGE PRE-FIN. 1x8 ALUM. CLAD FRIEZE BD. ON WOOD BLOCKING VINYL COVE BASE 4" SPLIT FACE VENEER GRADE (VARIES) WINDOW HEADER W/ BATT INSULATION INBETWEEN 'AZEK' 5/4 WINDOW STOOL W/ BULL NOSE 4" HIGH CAST STONE SILL W/ SLOPED TOP 6'-10" R.O.1'-8"5'-2" WINDOW R. O. HEIGHTPERMA-BARRIER THRU-WALL FLASHING (TO START @ WOOD PLATE & EXTENT UNDERSIDE OF STONE SILL) W/ WEEP HOLES @ 24" O.C. BELOW.( 5'-4" WINDOW BRICK OPENINGWIDTH )PRE-FIN. 1X6 (CUT) ALUM. CLAD SOFFIT 5/8" GYP. BD. (PAINTED)2'-0"12 5 1" 'GRACE' PERMA-BARRIER THRU-WALL FLASHING W/ DRAINAGE MAT, DRAINAGE WEEPS @ 24" O.C. & MIN. 3" LAYER PEA GRAVEL ON TOP OF FLASH'G. GROUT AIR SPACE SOLID BELOW FLASH'G FINISH FLOOR 1 LAYER OF 5/8" GYP. BD. (PAINTED)8'-1 1/4"8"EL. = 100'-0" CONC.FOUND. (SEE STRUCT.)FIRST FLOOR PLATE HEIGHT(4" SPLIT FACE VENEER)PRE-FINISHED ALUM. GUTTER ON ALUM. CLAD 2X8 FRIEZE BD. W/ CUT TOP (R-38) BLOWN-IN INSULATION 3'-0" 2X6 BLOCKING SEE STRUCT. ASPHALT SHINGLES ON 30# ROOF FELT ON APA RATED SHEATHING W/ EDGE SUPPORT (24/16 RATING) ON PRE-ENGINEERED ROOF TRUSSES CARDBOARD INSULATION BAFFLE @ 48" O.C. TURN OUT FLANGES AND NAIL TO U/S OF TOP CHORD AND HORIZONTAL 2X6 BLOCKING NOTE: MINIMUM FREE AIR AREA - 3 12" X 2 2 12" @ 48" O.C. 2'-9" SHEATHING STOPS AT U/S OF TOP CHORD NOTE: INSULATION SHALL BE FSK TYPE BATTS (CLASS A) W/ FLAME SPREAD OF 25 OR LESS AND SMOKE DEVELOPMENT OF 450 OR LESS SLAB ON GRADE - SEE STRUCTURAL SHEETS FOR DETAILS PRE-FINISHED ALUM. GUTTER ON ALUM. CLAD 2X8 FRIEZE BD. W/ CUT TOP 2X4 WOOD FRAMING @ 24" O.C. FULLY VENTED ALUMINUM SOFFIT PANELS PRE-FIN. METAL DRIP EDGE 1X8 ALUM. CLAD FRIEZE WOOD BLOCKING 2X6 BLOCKING SEE STRUCT. VINYL COVE BASE 4" SPLIT FACE VENEER GROUT VOID FULL BELOW GRADE 'GRACE'PERMA-BARRIER THRU-WALL FLASHING W/ DRAINAGE MAT, DRAINAGE WEEPS @ 24" O.C. & MIN. 3" LAYER PEA GRAVEL ON TOP OF FLASH'G. GROUT AIR SPACE SOLID BELOWFLASH'G GRADE (VARIES)8'-1 1/8"FIRST FLOOR PLATE HEIGHT5/8" GYPSUM BD. (PAINTED).2'-0"(4" SPLIT FACE VENEER)12 5 1 LAYER OF 5/8" GYP. BD. (PAINTED) 4" BRICK ON 1" MIN. AIR SPACE ON TYVEK AIR/MOISTURE BARRIER (OR EQUAL) (LAP OVER THRU-WALL FLASH'G IN SHINGLE FASHION) ON 1/2" SHEATHING ON 2X6 STUDS AT 16" O.C. W/ 6" (R-19) FSK BATT INSULATION. (ONE HOUR RATED, SEE UL # U356, SHT. A16). ASPHALT SHINGLES ON 30# ROOF FELT ON APA RATED SHEATHING W/ EDGE SUPPORT (24/16 RATING) ON PRE-ENGINEERED ROOF TRUSSES CONC.FOUND. (SEE STRUCT.) (R-38) BLOWN-IN INSULATION 3'-1 1/2" 2X BLOCKING VERT. @ 48" O.C. SEE STRUCTURAL. 2'-9" CARDBOARD INSULATION BAFFLE BEYOND @ 48" O.C. TURN OUT FLANGES AND NAIL TO U/S OF TOP CHORD AND HORIZONTAL 2X6 BLOCKING NOTE: MINIMUM FREE AIR AREA - 3 12" X 2 2 12" @ 48" O.C. SHEATHING STOPS AT U/S OF TOP CHORD 5/8" GYPSUM BD. (R-21) BATT INSULATION EXTENDED INTO THE OPEN SPACE OF THE TRUSS WEB MEMBERS INSULATION BAFFLE(R-38) BLOWN-IN INSULATION VERTICAL TRUSS MEMBER PRE-ENG. GIRDER TRUSS. W/ HIGH BOTTOM CHORD. (SEE STRUCT.) 2X4 STUDS @ 24" O.C. AS REQ'D. ALUMINUM FOIL FACE POLYISO. RIGID INSULATION (LTTR = 5.7/ INCH) ASTM C1289 LIKE JOHNS MANVILLE CIMAX BOARD TOTAL LTTR VALUE = 17.4 OR 3" BOARD (R-21) BATT INSULATION EXTENDED INTO THE OPEN SPACE OF THE TRUSS WEB MEMBERS 2X4 STUDS @ 24" O.C. AS REQ'D. 5/8" GYPSUM BD. PRE-ENG. GIRDER TRUSS. W/ HIGH BOTTOM CHORD. (SEE STRUCT.) ALUMINUM FOIL FACE POLYISO. RIGID INSULATION (LTTR = 5.7/ INCH) ASTM C1289 LIKE JOHNS MANVILLE CIMAX BOARD TOTAL LTTR VALUE = 17.4 OR 3" BOARD Upper Window Plan Details @ Gym Scale: 1 1/2" = 1'-0" Typ. Outside Corner DetailInside Corner Detail Typ. Lower Window Plan Detail @ Front Elevation - Gym Typ. Jamb Detail 2 A.304 3 A.304 5'-2" WINDOW R. O. (VERIFY)2'-10" WINDOWR. O. (VERIFY)A.304 2 A.3043 Wall Section @ Gym Scale: 1 1/2" = 1'-0" 1 A.304 Column Plan Detail Scale: 1" = 1'-0" 4 A.304Scale: 1 1/2" = 1'-0" CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.304 WALL SECTIONS JCRC (2) 2x12 CONTINUOUS BOX BEAM W/ SPACERS. SEE STRUCTURAL DRAW'GS 2 1/2" BATT INSULATION W/ KRAFT PAPER ON WARM SIDE Attic 4"7 1/2"3 1/4"4 1/2" 3'-3"1 1/2" 5" OGEE ALUM. GUTTER ON ALUM. CLAD 2x8 FASCIA W/ CUT TOP FULLY VENTED ALUMINUM SOFFIT ON 2x4 @ 24" O.C. FRAMING. PRE-FINISHED METAL DRIP EDGE 1x10 (CUT) ALUM. CLAD ON 1x8 ALUM. CLAD FRIEZE ON TYVEK COMMERCIAL WRAP ON 1/2" SHEATHING 2'-9" CAULKING 25 1/4"2 6 6 2 6 2 6 DOUBLE 2x6 PLATE STRAP TIE BEYOND & FOREGROUND - BETWEEN EACH WINDOW. (SEE STRUCTURAL) (R-38) CLOSED CELL BLOWN-IN INSULATION ANCHOR STRAPS @ EACH TRUSS. SEE STRUC. 2 6 CARDBOARD INSULATION BAFFLE BEYOND @ 48" O.C. TURN OUT FLANGES AND NAIL TO U/S OF TOP CHORD AND HORIZONTAL 2X6 BLOCKING NOTE: MINIMUM FREE AIR AREA - 3 12" X 2 2 12" @ 48" O.C. 2X6 BLOCKING SEE STRUCT. 2X BLOCKING VERT. @ 48" O.C. SEE STRUCTURAL. STOP SHEATING AT U/S OF TOP CHORD 2 6 2 X 4 FRAMING AS REQUIRED W/ 3 1/2" (R-11 MIN.) BATT INSULATION W/ KRAFT PAPER ON WARM SIDE) DOUBLE HUNG PICTURE WINDOW W/ OBSCURE GLASS & CENTER RAIL TO SIMULATE DOUBLE HUNG APPEARANCE. SEE WINDOW SCHEDULE.7 3/4"8" 10 1/2" WOOD COLUMN. (SEE STRUCTURAL). PROVIDE 1/4" PLYWD. SPACERS. CONTINUOUS 2 X 6 COLUMN TO UNDERSIDE OF BOXED BM. ABOVE. TYP EA. SIDE OF WINDOW (SEE STRUCT.) 1/4" APA RATED PLYWD. PAINTED ON BOTH SIDES. (LIGHT GRAY COLOR ON WINDOW SIDE). ALUM. CLAD 1x8 (CUT) CORNER BD'S ALUM. CLAD 1x6 (CUT) TRIM ON TYVEK COMMERCIAL WRAP ON 1/2" SHEATHING ON CONTINUOUS VERTICAL (2) 2 X 6 STUDS W/ 1/2" PLYWD. SPACER (SEE STRUCT.) ALUM. CLAD 1x10 (CUT) TRIM PICTURE WINDOW. (SEE WINDOW SCHEDULE) CAULKING TYP. 2 X 6 STUDS W/ 12 PLYWOOD SPACER TO UNDERSIDE OF BOXED BM. ABOVE 2'-6" R. O.4"4"2'-6" R.O.10 1/2"7 1/2" 6 3/4"6 3/4"3 3/4"3 3/4"7 3/4"SEE STRUCTURAL FOR COLUMN PROVIDE 1/4 PLYWD. SPACERS 7 3/4"STRAP TIE @ EACH (2) 1 3/4 X 5 1/2 LVL (SEE STRUCT) 1 2" AZEK PANEL ℄ GIRDER TRUSS ABOVE. SEE STRUCTURAL 9 3/4"2 3/4" 4" VERIFY CLEARANCE WINDOW MANUF. 4 3/8" GALV. LINTEL (REFER TO STRUCTURAL) 8" BRICK SOLDIER COURSE GRACE PERMA-BARRIER THROUGH WALL FLASHING W/ WEEP HOLES @ 24" O.C ON 1/2" SHEATHING ON HEADER W/ HANGERS W/ 2 1/2" BATT INSUL. W/ KRAFT PAPER ON WARM SIDE. BREAK METAL SILL W/ DRIP EDGE ON P.T. 2x6 (CUT) BLOCKING W/ SLOPED TOP.12'-0" PLATE HGT.CAULKING 1/4" APA RATED PLYWD. PAINTED ON BOTH SIDES. (LIGHT GRAY COLOR ON WINDOW SIDE). 3/4" PLYWOOD ON 2 X 8'S @ 16"OC FOR PLATFORM IN GYM. EQUIP. RM THRU-WALL FLASHIN W/ DRAINAGE MAT DRAINAGE WEEPS @ 24" O.C. BLOCKING AS REQ'D.10'-6"1'-8"GRADE (VARIES) 4" SPLIT FACE VENEER 1" AIR SPACE ON TYVEK AIR/MOISTURE BARRIER (OR EQUAL) ON 1/2" SHEATHING ON 2X6 WD. STUDS AT 16" O.C. W/ MIN. R-21 FSK BATT INSULATION 2 3/8" HIGH x 5" DP. SLOPED LIMESTONE SILL W/ DRIP ON PERMA-BARRIER THRU-WALL FLASHING (TO START @ WOOD PLATE & EXTEND UNDERSIDE OF STONE SILL) W/ WEEP HOLES @ 24" O.C. BELOW. DOUBLE HUNG PICTURE WINDOW W/ OBSCURE GLASS. SEE WINDOW SCHEDULE DAMPPROOFING. LAP OVER FOUNDATION MIN. 6" VINYL COVE BASE 5 1/2"GROUT SOLID BELOW FLASHING 8"CONT. P.T. SILL PLATE THRU-WALL FLASHIN W/ DRAINAGE MAT DRAINAGE WEEPS @ 24" O.C. ANCHOR BOLTS. REFER TO STRUC. FOR SPACING & SIZE CONCRETE FOUNDATIONS & SLABS OVER COMPACTED, TERMITE TREATED FILL 10 MIL VAPOR BARRIER 2'-1 1/2"2'-1 1/2"PRE-MANUFACTURED STONE VENEER OVER CORROSION RESISTANT WIRE LATH OVER 3/4" P.T. PLYWOOD OVER STUD FRAMING POST (SEE STRUCT.) 2 X 6 STUDS @ 16" OC ALL DIMENSIONS ON FRAMING PLANS ARE TAKEN FROM STUD TO STUD AND DO NOT INCORPORATE THE DRYWALL. Stair SectionJ A.305 Scale: 1/2" = 1'-0" Typ. Draft Stop Sec. Detail Scale: 1-1/2" = 1'-0" Typ. Draft. Stop Access Plan Detail Scale: 1-1/2" = 1'-0" CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.305 SECTION DETAILS JCRC Typ. Fence Detail Scale: 3/4" = 1'-0" Typ. Fence Post Detail Scale: 1" = 1'-0" 1 A.305 2 A.305 3 A.305 4 A.305 Typ. Sidewalk @ Ext. Door5 A.305 Scale: 1/2" = 1'-0" 11"9'-1 1/8"6 7/8"2'-10"16 RISERS AT 6-13/16" EACH1 X _RISER 2X12 TREAD STOCK 2X12 STAIR STRINGER 3/4" F.R.T. PLYWOOD FLR SHEATHING ON 2X12 JOISTS @ 16" O.C. 1-1/2" WOOD HANDRAIL PER CODE 1'-0" 1'-0" FIRST FLOOR 3'-4 7/8"1" NOSING 5'-4 5/8"13'-10 3/4"3 1/2"5 1/2" 15 T. @ 11" EACH = 13'-9" 1 3/4" PRE-ENG. WOOD TRUSSES @ 24" O.C. 2x6 @ 24"O.C. BRIDGING W/ HANGERS AS REQ'D.8'-0"8'-0"DROPPED 2X CEILING FRAMING OVER STAIR WELL GYP. WALLS & CEILING IN STAIRWELL ASPHALT SHINGLES ON ROOF FELT ON 1/2" ROOF SHEATHING DESIGN TRUSSES FOR DRAFT STOP LOAD 2-LAYERS OF TYPE "X" GYP. BRD. (CEILING) 3/8" PLYWOOD NOTE: OPENINGS IN PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES CONSTRUCTED AS REQUIRED FOR THE PARTITIONS PNEUMATIC HEAVY-DUTY DOOR CLOSER - OR APPROVED EQUAL (3) HEAVY-DUTY DOOR HINGE 2X4 DOOR FRAME 1X3 DOOR FRAME OVERLAP DOOR W/ WALL TO PROVIDE CONTINUOUS DRAFT STOPPING 1/2" PLYWOOD ONE SIDE 44"44"MINIMUM36" MINIMUM3'-4" MASONRY OPENING 36" MINIMUM 28"6'-0"CONC. SIDEWALK REFER TO CIVIL DWGS. ADA DOOR APPROACH Scale: 1/2" = 1'-0" Gym Wall Elev. Rm. 116 Cubby Section Rm. 102 Car Seat Cubby Elev. Rm. 102 Stair Wall Elev. Rm. 112 5 A.400 2 A.400 3 A.400 4 A.400 Recep. Desk Elev. Rm. 102 11 A.400 Corridor Window Elev. Rm. 132 9 A.400 Recep. Desk Elev. Rm. 102 13 A.400 Recep. Desk Elev. Rm. 102 10 A.400 Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.400 INTERIOR ELEVATIONS JCRC Crib Cubby Elev.7 A.400 Recep. Desk Elev. Rm. 102 12 A.400 Recep. Desk Elev. Rm. 102 14 A.400 Lobby Door Elev. Rm. 111 15 A.400Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" Fire Extinguisher Detail1 A.400 Scale: 1/2" = 1'-0" PROVIDE CLEAR AREA FOR OWNER PROVIDED ART SEE BRANDING BOOK PROVIDED BY OWNER FOR EXACT SIZING & PLACEMENT MOUNT FIRE ALARM HORN/STROBE/EMER. LIGHT PER ELEC. PLANS 1'-0"PROVIDE CONDUIT THROUGH WALL FOR OUTLET & CABLE IN CLOSET 130 2'-4"2"2"2"3'-0"2"2"2'-4"2"2'-4"2"2'-4"2"3'-0"3'-10"2'-10 1/2"6'-10"CHAIR RAIL WHITE GYP. BD. (PAINT) 4" VINYL BASE 2" H.M. FRAME (PAINT- WHITE IN HALLWAY -RED IN ROOM)TEMPERED GLASS P.LAM. ADJUSTABLE SHELVES 1/2" P. LAM BACK PANEL 2'-6" 2'-4 3/4" P.LAM. ADJUSTABLE SHELVES 3 A.400 8'-0"2'-4 1/4"2'-4 1/2"2'-5 1/4"EQ.EQ.EQ.EQ.EQ. DOOR SLAB LINE OF STAIRS BEYOND COT AREA - FULL HEIGHT FRP FULL HEIGHT DIVIDING WALL P. LAM COUNTER SOLID SURFACE COUNTER SUPPORT BRACKET (2) 24" FILE CAB. ALL CABINETS TO MATCH - MAPLE OPEN KNEE SPACE BELOW P.LAM C.TOP 4" VINYL BASE2'-6"3'-0"3'-0"3'-8"6'-8"GYP. BD. (PAINT) 4" VINYL COVERBASE 2" H.M. FRAME (PAINT) FIXED SAFETY GLASS PENCIL DRAWER P. LAM COUNTER SOLID SURFACE COUNTER SUPPORT BRACKET OPEN KNEE SPACE BELOW P.LAM C.TOP NOTE: ALL OF RECEPTION COUNTER SHALL BE STANDARD P. LAM TOPS WALL AT INFANT CRIB CUBBY CHAIR RAIL RETURN BOTH SIDES ON BACKER BOARD BACKER BOARD ONLY GYP. BRD. (PAINT) 4" VINYL COVERBASE 45" MIN. CLEARANCE FOR CRIB 9" WALL-PAPER BORDERR. 1'-5 1/4"4" CROWN MLDG. MAPLE WOOD VENEER W/ NATURAL FINISH-COORD. W/ OWNER WOOD VENEER COLUMN W/ FLUTE 4" TOE KICK ARCH TOP 2" MLDG. 3/4" ADJ. SHELVES 1 1/2" P. LAM COUNTER 2'-11 1/4" 3 3/4" 2'-11 1/4"2'-11 1/4"6"3'-0"1'-0"2'-2"4"4 1/2"1'-6"1'-6"3"1'-6"1'-6"3"2'-6"14 A.400 3 3/4"3 3/4"3 3/4"5 1/4"DECORATIVE WOOD PILASTER 6" WOOD BASE6"3"3/8"3/8"3 3/4"ALL CAB'T AS SPEC'D BY OWNER MAPLE WD. VENEER W/ NATURAL STAIN FINISH - COORD. W/ OWNER 4" CROWN MLDG. 4" TOE KICK 1-1/2" P.LAM C. TOP 3/4" ADJ. SHELVES 1'-6"1" SCHED. PARTITION EXIT 9'-0"ACCENT DOOR CHAIR RAIL (SEE SHEET A.500 & A.501 KEEP AREA CLEAR OF DEVICES EXIT/EMER. LIGHT (VERIFY W/ MECH. DOCS. WALL MOUNTED 10LB TYPE ABC FIRE EXTINGUISHER AT MECH. EQUIP. PLATFORM OR 10LB TYPE K FIRE EXTINGUISHER AT KITCHEN, SUPPLIED & INSTALLED BY G.C.48" MAX TO EXTINGUISHERHANDLE (MAX.)F.F.27" MAX.48" TO HIGHEST DEMOUNTING POINTG.C. SHALL PROVIDE AND INSTALL FIRE EXTINGUISHER CABINET, (1)10LB ABC FIRE EXTINGUISHER, AND ALL REQUIRED MOUNTING HANGER EQUIPMENT. CABINET SHALL BE ELITE SERIES SEMI-RECESSED VERTICAL DUO FIRE EXTINGUISHER CABINET, OR APPROVED EQUAL. Kitchen Elev Rm. 126 20 A.401 21 A.401 22 A.401 Infant Changing Station Elev23 A.401 Sink Base Elev24 A.401Rms. 104, 124 & 125 Built-in Elev.25 A.401 Rm. 109 Built-in Elev.26 A.401 Rms. 137 & 112 Scale: 1/2" = 1'-0" Built-in Elev.27 A.401 Rm. 106 Built-in Elev.28 A.401 Rm. 109 & 134 Built-in Elev.29 A.401 Rm.134 Infant Changing Station Elev30 A.401 Rms. 119 & 121Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" Scale: 1/2" = 1'-0" CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.401 INTERIOR ELEVATIONS JCRC PAPER TOWEL DISPENSER PROVIDED BY OWNER INSTALLED BY G.C.S.S. WIRE SHELVING PROVIDED & INSTALLED BY G.C. SOAP DISPENSER PROVIDED BY OWNER INSTALLED BY G.C.WALL MTD. BARRIER TO PROTECT HAND SIND FROM 3 COMP. SINK TO COMPLY W/ HEALTH DEPT. STDS. (INSTALLED BY G.C.) F.R.P. FULL HEIGHT PROVIDE CODE APPROVED THERMOMETER IN EACH COMPARTMENT OF EACH REFR. AND FREEQER WHERE FOOR IS STORED NOTE: PROVIDE WALL MTD. PAPER TOWER DISPENSER & WASTE RECEPTACLE @ HAND SINK5'-0"FREEZERREFR. FUTURE REFR. 1'-3"1'-3" HOLD CLEAR EA. SIDE OF CENTERLINE OF SINK34" MAX29" MIN.4'-0" MAX. REACH HT.HT AS REQUIRED TO SERVICEPAPERTOWEL DISPENSERGYP. BD. (PAINT) (2) MICROWAVE/OVEN COMBOS SEARS COMMERCIAL KENMORE 49613 30" (INSTALLED BY G.C. PER MANUF. SPECS.) COUNTERTOP COUNTERTOP 34" MAX4" P. LAM. BACKSPLASH 36" MAXF.R.P. FULL HEIGHT GYP. BD. (PAINT) 1 1/2" P. LAM COUNTER TOP PROVIDE CODE APPROVED THERMOMETER IN EACH COMPARTMENT OF EACH REFR. & FREEZER WHERE FOOD IS STORED U.C. REFR. 4" TOE KICK (VINYL BASE) 4" P. LAM. BACK SPLASH 3/4" P. LAM. ADJ. SHELF (TYP.) TOWEL & SOAP DISPENSER VERIFY LOCATION W/ OWNER (OPEN)(OPEN)2'-8"1'-6"2'-10"AS REQUIRED TO REACH CONTROLS 48" MAX.48" MAX. TO OPERABLEELEMENTSPAPER TOWEL DISP. (BY OWNER) SOAP DISPENSER (BY OWNER) 4" BACKSPLASH SINK (BEYOND) FIN. FLOOR2'-6"36" MAX. TO OPERABLEDEVICESCL 3/4" P. LAM ADJ. SHELF (TYP) 4" P. LAM. BACKSPLASH SINK (BEYOND) FIN. FLOOR4" TOE KICK 2'-0"3'-0" MAX REACH HTFOR OPERABLE PORTIONOF DISPENSERSCL 3/4" P. LAM ADJ. SHELF (TYP) 4" P. LAM. BACKSPLASH SINK (BEYOND) 4" TOEKICK2'-0"2'-10"1'-8"2'-6"3/4" P. LAM ADJ. SHELF (TYP) 5'-0" 2'-6"2'-6" 5'-0" 2'-6"2'-6" 7'-9"2'-10" MAX.3/4" P. LAM ADJ. SHELF (TYP) 4" P. LAM. BACKSPLASH SINK (BEYOND) 4" TOEKICK PROVIDE WALL MOUNTED PAPER TOWEL DISPENSER & WASTE RECEPTACLE MICROWAVE SHELF 2'-10"AS REQUIRED TO REACH MICROWAVE CONTROLS 48" MAX. 3/4" P. LAM ADJ. SHELF (TYP) 4" P. LAM. BACKSPLASH SINK (BEYOND) FIN. FLOOR 4" TOE KICK2'-0"3'-0" MAX REACH HTFOR OPERABLE PORTIONOF DISPENSERSCL 1 1/2" P. LAM COUNTER TOP 4" TOE KICK (VINYL BASE) 4" P. LAM. BACK SPLASH OPEN SHELF TO MATCH CABINETS 3/4" P. LAM. ADJ. SHELF (TYP.) TOWEL & SOAP DISPENSER VERIFY LOCATION W/ OWNER (OPEN)(OPEN)2'-8"1'-6"2'-10"NOTE: ALL COUNTERTOPS IN CHILDREN'S ROOMS, RESTROOMS, AND LOUNGE SHALL BE POST FORMED, ROLL TOP - NO DRIP EDGES AS REQUIRED TO REACH CONTROLS 48" MAX.48" MAX. TO OPERABLEELEMENTSNOTE: ALL KITCHEN COUNTERS SHALL BE STANDARD P. LAM TOPS NOTE: ALL COUNTERTOPS IN CHILDREN'S ROOMS, RESTROOMS, AND LOUNGE SHALL BE POST FORMED, ROLL TOP - NO DRIP EDGES Scale: 1/2" = 1'-0" Typ. Adult B.F. Restroom Elevs. 31 A.402 Rm. 103 32 A.402 33 A.402 34 A.402 Typ. Child Cab. Lav. Elevs. 37 A.402 39 A.402 Scale: 1/2" = 1'-0" Drinking Fountain Elev Rm. 132 1 A.402 Mop Sink Elev. Rm. 132 8 A.402 Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" Conference Room Elev. Rm. 132 6 A.402 CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.402 INTERIOR ELEVATIONS JCRC Scale: 1" = 1'-0" Adult Roll-Under Sink7 A.402 9 A.402 Scale: 1" = 1'-0" Child Roll-Under Sink Typ. Child B.F. Wall Mount Sink 40 A.402 41 A.402 38 A.402 Typ. Child B.F. Restroom Elevs. Rm. 103 Scale: 1/2" = 1'-0" 35 A.402 36 A.402 Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" Six Years & Up 33"-36"17"-19"36" 16 "-18" 12" MIN. 12"33"- 36"42" 39" - 41"39"- 41"18" MIN.(Rm. 114 ONLY)6"34" max.9" min.29" min.17" min. 3" max.48" MAX.32" MIN.40" MAX.29" MIN.34" MAX.WALL-HUNG LAVATORY TO BE BY AMERICAN STANDARD-LUCERNE. LAVATORY MEETS ADA GUIDLINES. INSTALL WITH TOP OF FRONT RIM AT 34" A.F.F. (PER MANUF. SPECS.). PROVIDE NECESSARY BACKING AS REQ'D.24" TO 25" AT P1, 26" TO 30" AT P218" TO 20" AT P1, 20" TO 25" AT P248" (MIN.) F.R.P.14" AT P1, 14 TO 17" AT P211" TO 12" AT P1, 12" TO 15" AT P214" AT P1, 14"TO 17" AT P212"42" TOILET PAPER DISPENSER 7"-9"24" TO 25" AT P1,26" TO 30" AT P218"34" - 36" 24" (MIN.) F.R.P. RUN F.R.P. WALL FINISH MIN. 24" PAST THE EDGE OF THE WC. (TYP.)GYP. BRD. (PAINT) PAPER TOWEL DISPENSER G.F.I.C. RECEPT.48"TO OPENINGA.5/8" HIGH BY 1/32" RAISED LETTERING (UNLESS NOTED OTHERWISE) B.GRADE 2 BRAILLE POSITIONED DIRECTLY BELOW TEXT C.1/32" RAISED PICTOGRAM WITH 70% CONTRASTING BETWEEN BACKGROUND AND TEXT. FINISH TO BE EGGSHELL. D.COLOR TO BE BLUE BACKGROUND WITH WHITE LETTERS. ROOM NAME2"VARIES 6" MIN.8" MIN.9" ADA TACTILE SIGN 48" MIN. TO LOWEST TACTILE CHAR.60" MAX TO HIGHEST TACTILE CHAR.SIGNAGE NOTES: PROVIDE AND INSTALL PLUMBING INSULATION/ SHIELDS AT DRAINS VALVES AND PIPING NO SHARP HAZARDS ARE ACCEPTABLE 11" TO 12" AT P1, 12" TO 15" AT P218" TO 20" AT P1, 20 TO 25 AT P2SIGNS TO BE PROVIDED AND INSTALLED BY G.C. OPPOSITE 4"48" (MIN.) F.R.P.4"TOILET PAPER DISPENSER 1'-0"1 1 2" MIN.48" (MIN.) F.R.P.1'-0"FROM TOPOF GRAB BARTO BOT. OFDISPENSER24" 12" AT P1 AND P2 24"1'-3"B.O. DISP.2'-0" TOILET PAPER DISP. (SIDEVIEW)15" (MIN.)TOILET PAPER DISPENSER 7"-9" WIRE SHELVING GYP. BD. (PAINT) 16" X 20" MIRROR BOT AT 35" TOWEL DISPENSER VERIFY LOCATION WITH OWNER 4" PLASTIC LAM. BACKSPLASH 4" TOEKICK 1 1 2" COUNTER TOP 5'-6"WIRE SHELVING GYP. BD. (PAINT)5'-6"16" X 20" MIRROR BOT AT 34"30" MAX3'-0" MAX REACH HTFOR OPERABLE PORTIONOF DISPENSERS31"MAX3'-0" MAX REACH HTFOR OPERABLE PORTIONOF DISPENSERS24"MIN.30" MIN KNEE SPACE 30" MAX.9" MIN.24" MIN.17" MIN. 3" MAX.32" MIN.36" MAX.24" MIN.30" MAX.WALL-HUNG LAVATORY TO BE BY AMERICAN STANDARD-LUCERNE. LAVATORY MEETS ADA GUIDLINES. INSTALL WITH TOP OF FRONT RIM AT 30" A.F.F. FOR CHILDREN PROVIDE NECESSARY BACKING AS REQ'D. PROVIDE AND INSTALL PLUMBING INSULATION/ SHIELDS AT DRAINS VALVES AND PIPING NO SHARP HAZARDS ARE ACCEPTABLE 1'-3" MIN. 16" X 20" MIRROR TOWEL DISPENSER VERIFY LOCATION WITH OWNER 4" TOEKICK 1 12" COUNTER TOP 4" P.LAM BACK SPLASH SIDEWALL MNT SOAP DISPENSER BOT AT 27" AFF MAX 2'-0" GENERAL NOTES: 1. PROVIDE FILLERS AS REQ'D @ CABINET/WALL INTERSECTIONS TO ALLOW FOR PROPER DOOR/DRAWER SWING CLEARANCES 2. ALL PAPER TOWEL, TOILET PAPER AND SOAP DISPENSERS ARE TO BE PROVIDED BY OWNER AND INSTALLED BY G.C. 3. G.C. TO INSTALL ALL OWNER PROVIDED EQUIP. PER MANUF. SPECS. 4. G.C. TO PROVIDE SHOP DRAWINGS PRIOR TO FABRICATION FOR OWNER APPROVAL. G.C. ALSO TO PROVIDE AND INSTALL ALL CABINETS, COUNTERTOPS, AND HARDWARE. 5. ALL BUILT-INS TO BE COORDINATED WITH M.E.P. TO DETERMINE EMERGENCY FIRE AND LIGHTING REQS. NEW ELKAY #EZSTL8 WALL MOUNT DRINKING FOUNTAINS. DRINKING FOUNTAINS MEET A.D.A. GUIDELINES36" MAX.27" (MIN.)8" 6 1/4"9" (MIN)15" (MIN)5" (MAX)36" MAX - WHEELCHAIR38" - 43" - STANDINGLINE OF SOFFIT DUE TO STAIR 6'-8"LINE OF WALL MOP SINK WALL MOUNTED SERVICE SINK FAUCET-TO SPECIFICATIONS FRP ON WALL 2 SIDES 3'-4"4'-0"2'-1" 1'-5" MIN9" MIN3/4"2'-10"MAX.2'-3"MIN.5 1/2"1 1/2"8" MIN. P-LAM COVERED POST FORMED COUNTERTOP WITH "NO-DRIP" EDGE SST DROP IN SINK WITH OFFSET DRAIN FOR ADA CLEARANCE SEE PLUMBING ADA COMPLIANT FAUCET FIXTURES SEE PLUMBING 30"MAX.2'-0"MIN.4 1/2"P-LAM COVERED POST FORMED COUNTERTOP WITH "NO-DRIP" EDGE SST DROP IN SINK WITH OFFSET DRAIN FOR ADA CLEARANCE SEE PLUMBING ADA COMPLIANT FAUCET FIXTURES SEE PLUMBING P-LAM COVERED REMOVABLE PANEL SECURED TO CLEATSWITH ST. STL. FINISH WASHERS AND SCREWS. PROVIDE ADA CLEARANCES DIMENSIONED. 2'-1" 1'-5" MIN 3/4" 8" MIN.1 1/2"PLAM-1 9" MINPLAM-1 P-LAM COVERED REMOVABLE PANEL SECURED TO CLEATSWITH ST. STL. FINISH WASHERS AND SCREWS. PROVIDE ADA CLEARANCES DIMENSIONED. CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 A.500 SCHEDULES JCRC INSULATED SAFETY GLASS PRE-FIN. ALUM.9'-4 1/4"6'-8"1'-10"FLUSH H.M. OR WOOD SLAB 12"X12" SAFETY GLASS WINDOW A B C D E F G H I OPEN FLUSH H.M. OR WOOD SLAB HALF DOOR CENTER DOOR HANDLE R.O. HEIGHT = HEIGHT = 1" R.O. WIDTH = WIDTH = 1" ROUGH FRAMING DIAGRAM INTERIOR DOORS ROUGH FRAMING DIAGRAM INTERIOR WINDOWS INSULATED SAFETY GLASS INSULATED SAFETY GLASS 10"INTERNAL BLINDS 10"HARDWARE SET 1 ITEM: HINGES LOCKSET CLOSERS EXIT PANIC DEVICES - PADDLE FLAT GOODS MODEL NUMBER: SPEC: HAGER SCHLAGE LCN VON DUPRIN ROCKWOOD STYLE/FINISH: ACCEPTABLE SUBSTITUTE: BOMMER, STANLEY, MCKINNEY YALE, SARGENT NO SUBSTITUTION PRECISION, SARGENT ANY BHMA MEMBER HARDWARE SCHEDULE HARDWARE SPECIFICATIONS: HARDWARE SET 11 2 HINGE 1 PASSAGE SET 1 KICK PLATE HARDWARE SET 12 3 HINGE 1 LOCKSET 1 KICK PLATE HARDWARE SET 13 1 HINGE 2 SPRING HINGE 1 PASSAGE SET 1 O.H. HOLDER 1 WALL BUMPER 1 KICK PLATE 1 CLOSER HARDWARE SET 14 2 HINGE 1 PASSAGE SET 1 KICK PLATE 1 FLOOR STOP HARDWARE SET 15 3 HINGE 1 PRIVACY 1 WALL BUMPER 1 KICK PLATE 1 O.H. HOLDER HARDWARE SET 16 1 HINGE 2 SPRING HINGE 1 LOCKSET 1 O.H. HOLDER 1 WALL BUMPER 1 KICK PLATE HARDWARE SET 17 4 HINGE 1 PRIVACY 1 DUTCH BOLT 1 WALL BUMPER 1 KICK PLATE 1 MAG CATCH HARDWARE SET 18 3 HINGE 1 LOCKSET 1 CLOSER 1 WALL BUMPER 1 KICKPLATE NOTE: DOOR AND HARDWARE SHALL NOT PROJECT INTO PATH OF EGRESS MORE THAN 7" WHEN FULLY OPEN. HARDWARE SET 19 3 HINGE 1 LOCKSET 1 CLOSER 1 WALL BUMPER 1 KICK PLATE 1 W/S 1 THRESHOLD 1 SWEEP HARDWARE SET 20 3 HINGE 1 EXIT PANIC DEVICE W/ LEVER TRIM 1 CLOSER 1 W/S 1 THRESHOLD 1 SWEEP 1 DRIP CAP 1 KICK PLATE BB1279 4-1/2" W101S - DANE 10" X 34" BB1279 4-1/2" 10" X 34" BB1279 4-1/2" NRP 1250 4'1/2" W101S - DANE 454H 409 10" X 34" 1461 (SLIM COVER) BB1279 4-1/2" W101S - DANE 10" X 34" FS13 DOME STOP BB1279 4-1/2" W301S - DANE 409 10" X 34" 454H BB1279 4-1/2" NRP 1250 4'1/2" W581PD - DANE 454H 409 10" X 34" BB1279 4-1/2" W301S - DANE 409 10" X 34" 180 DEGREE HINGES W581PD DANE 180 DEGREE CLOSER 409 10" X 34" BB1279 4-1/2" W581PD - DANE 1461 (SLIM COVER) 409 10" X 34" 160V (3070) 613 36" 102VA 36" BB1279 4-1/2" NRP 1461 - H - CUSH (SLIM COVER) 160V (3070) 613 36" 102VA 36" 16AD 40" 10" X 34" 26D 626 32D 26D 626 32D (CENTER) (TOP BOTTOM) 626 32D 32D 32D ALUM. 26D 626 32D 26D 26D 626 32D 32D 32D (CENTER) (TOP BOTTOM) 626 32D 32D 32D 26D 626 32D 32D 26D 626 ALUM 32D 32D 26D 626 ALUM. 32D 32D ALUM. ALUM. ALUM. 26D ALUM. ALUM. ALUM. ALUM. ALUM. 32D HARDWARE SET 2 3 HINGE 1 LOCK 1 CLOSER 1 W/S 1 THRESHOLD 1 SWEEP 1 DRIP CAP 1 KICK PLATE HARDWARE SET 4 2 HINGE 1 LOCKSET 1 WALL BUMPER 1 KICK PLATE HARDWARE SET 5 1 HINGE 2 SPRING HINGE 1 PASSAGE SET 1 O.H. HOLDER 1 WALL BUMPER 1 KICK PLATE HARDWARE SET 6 3 HINGE 1 LOCKSET 1 CLOSER 1 WALL BUMPER 1 KICK PLATE HARDWARE SET 7 3 HINGE 1 PASSAGE 1 WALL BUMPER 1 KICK PLATE HARDWARE SET 8 3 HINGE 1 LOCKSET 1 WALL BUMPER 1 KICK PLATE HARDWARE SET 9 3 HINGE 1 PASSAGE 1 CLOSER 1 WALL BUMPER 1 KICK PLATE BB1279 4-1/2" NRP W511PD - DANE 1461- H - CUSH (SLIM COVER) 160V (3070) 613 36" 102VA 36" 16AD 40" 10" X 34" BA1279 4-1/2" W581PD - DANE 409 10" X 22" BB1279 4-1/2" NRP 1250 4'1/2" W101S - DANE 454H 409 10" X 34" BB1279 4-1/2" W581PD - DANE 1461 (SLIM COVER) 409 10" X 34" BB1279 4-1/2" W101S - DANE 409 10" X 34" BB1279 4-1/2" W101S - DANE 409 10" X 34" BB1279 4-1/2" W101S - DANE 1461 (SLIM COVER) 409 10" X 34" 26D 626D ALUM. ALUM. ALUM. ALUM. ALUM. 32D 26D 626 32D 32D (CENTER) (TOP BOTTOM) 626 32D 32D 32D 26D 626 ALUM. 32D 32D 26D 626 32D 32D 26D 626 32D 32D 26D 626 ALUM. 32D 32D 3 HINGE 1 LOCK 1 CLOSER 1 W/S 1 THRESHOLD 1 SWEEP by ALUM. DOOR SUPPLIER W511PD - DANE 1461- H - CUSH (SLIM COVER) 160V (3070) BRONZE 626D ALUM. ALUM. ALUM. ALUM. MODEL NUMBER:STYLE/FINISH: 1 EXIT PANIC DEVICE V99 (or by ALUM. Door Supplier) by ALUM. DOOR SUPPLIER by ALUM. DOOR SUPPLIER HARDWARE SET 3 3 HINGE 1 ALARM LOCK TRILOGY 1 ELEC. STK. 1 RECTIFIER 1 CLOSER 1 WALL BUMPER 1 KICK PLATE BA1279 4-1/2" VD 6111 SO-24 VAC 1461 (SLIM COVER) 409 10" X 34" 26D 26D ALUM ALUM 32D 32D W/ EXIT PANIC DEVICE ETDL27-S1G-V99 HARDWARE SET 10 3 HINGE 1 PRIVACY 1 WALL BUMPER 1 KICK PLATE BB1279 4-1/2" W301S - DANE 409 10" X 34" 26D 626 32D 32D NOTE: WHEN PANIC DEVICE IS REQ'D, SEE NOTE 4. NOTES: 1.PROVIDE HEAVY DUTY COMMERCIAL EXIT PANIC DEVICE, IN LIEU OF LOCKSET, AS REQ'D PER STATE CODE AT DOORS 100, 100A & 132. 2.ALL INTERIOR WINDOW SILLS ARE TO BE SOLID SURFACE - SPECIFICATION BY OWNER 3.PROVIDE CLOSER AT ALL 1 HOUR RATED DOORS. 4.ALL DOORS IN THE GYM TO BE ONE PIECE WELDED HOLLOW MTL. FRAME. INSTALL FRAME DURING ROUGH WALL FRAMING. 1 TYP. EXT. DOOR THRESHOLD 3"=1'-0" NOTES MAT'L FRAME FINISHFINISHMAT'L DOOR TYPE DOOR SIZEDOOR NO. Door Schedule HDWR. SET 131 3068 E FIRE RATING 100 3068 B AL/INSUL BRZ AL BRZ 1 +PANIC FULL LITE 100-A 100-B 3068 2636 E D WD PREF PTDHM 3 +PANIC 2 HALF LITE 12 X 12 LITEWDPREFPTDHM 101 3068 E 4 HALF LITEWDPREFPTDHM 103 3068 C 105 3036 F 106 3068 E 107 3068 C 108 3068 C 109 3068 E 110 3036 F 113 109-A 3068 G 106-A 3068 G 112-A 3068 G 114 3068 C 119 3068 E 120 3036 F 123 124 125 3068 3068 3068 E E C 126 NOT USED 127 3068 E 128 3068 A 124-A 3068 G 125-A 3068 G 121-A 3068 G 116-A 3068 G 120-A 3036 F 130 3068 C 134-A 3068 G 135 3036 137-A 3068 G 131-A 3068 G 137 139 3068 H 104-A 3068 G 104 3068 E 115 3068 C 118 3068 E 117 3068 C 116 3068 E 112 3068 E 132 3068 G 20 134 3068 E 138 122 3068 H 136 3068 C 3068 E 3036 F 3036 F 140 3068 C 119-A 3068 G WD PREF PTDHM WD PREF PTDHM WD PREF PTDHM WD PREF PTDHM WD PREF PTDHMWDPREFPTDHM WD PREF PTDHM WD PREF PTDHM WD PREF PTDHM WD PREF PTDHM WD PREF PTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM HALF LITEWDPREFPTDHM FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD 7 X 22 LITEWDPREFPTDHM 7 X 22 LITEWDPREFPTDHM 7 X 22 LITEWDPREFPTDHM WD PREF PTDHM WD PREF PTDHM WD PREF PTDHM WD PREF PTDHM WD PREF PTDHM WD PREF PTDHM FULL LITEHM/INSUL PTD HM PTD FULL LITEHM/INSUL PTD HM PTD HALF LITEWDPREFPTDHM 9 5 14 5 5 6 7 6 2 2 2 14 12 2 2 2 18 5 12 5 14 12 2 2 8 11 5 10 10 5 11 2 2 2 6 2 2 12 6 83 6 7 5 14 121 3068 E HALF LITEWDPREFPTDHM5 F WD PREF PTDHM 14 200 3068 C HM/INSUL PTD HM PTD 19 NOTE: 1.NATIONAL ACCOUNT PROVIDER: ALL HOLLOW METAL FRAMES, DOORS, WOOD DOORS, AND FINISH HARDWARE TO BE SUPPLIED BY GIRTMAN & ASSOCIATES. CONTACT MATT RODRIGUEZ AT MRODRIGUEZ@GIRTMAN.COM FOR PRICING. DOOR THERMAL PERFORMANCE CRITERIA GC SHALL PROVIDE DOORS THAT MEET THE THERMAL PERFORMANCE CRITERIA OF THE FOLLOWING DOORS: DOOR 112A, 116A,121A, 119A,113A,137A 134A,132, 109A, 106A,104A, 125A, 126A, 131A - U Factor : 0.65, SHGC: 0.40, PF: 0.04, VT: .80 DOOR 136 - U Factor: 0.130 DOOR 100 STORE-FRONT - U Factor : 0.65, SHGC: 0.40, PF: 0.04, VT: .80 DOOR 200 - U Factor: 0.130 WIN. NO. GREEN WHITE W2-8 HALL SIDE COLOR Interior Window Schedule W2-1 ROOM SIDE COLOR WHITE WHITE WHITE WHITE W2-3 W2-6 W2-2 W2-10 W2-11 W2-4 W2-5 W2-7 W2-9 W2-13 W2-12 GREEN RED RED BLUE BLUE YELLOW YELLOW WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE GLASS WHITE W2-14 WHITE W2-15 WHITE RED RED MAT'L FRAME H.M. MAT'L TEMP. Window Legend W1 W2 SINGLE HUNG VINYL WINDOWS (2 WIDE) W/ 1" INSULATED GLASS. UPPER OPERABLE - SASH TO HAVE SCREEN APPROXIMATE SIZE: 5'-2" WIDE (OVERALL) X 5'-2" HIGH - MANUFACTURER TO USE STANDARD SIZES. VERIFY ARCHITECT OF ANY DISCREPANCIES. TEMPERED GLAZING WHEN WITHIN 24IN OF DOOR OR WITHIN 18IN OF THE FLOOR. 36" x 36" SAFETY GLASS (TEMP.) LAMINATED WINDOW IN HOLLOW METAL PAINTED FRAME. REFER TO 9/A.400 30" X 36" VINYL WINDOW W/ 1" INSULATED CLEAR GLASS. 32" x 36" SAFETY GLASS (TEMP.) LAMINATED WINDOW IN HOLLOW METAL PAINTED FRAME @ GYMNASIUM. REFER TO 2/A.400 30" X 35" VINYL WINDOW W/ 1" INSULATED CLEAR GLASS. 40" X 35" VINYL WINDOW W/ 1" INSULATED CLEAR GLASS. 62" X 62" NON-OPERABLE PICTURE WINDOW W/ APPLIED MUNTINS. 60" X 35" VINYL WINDOW W/ 1" INSULATED CLEAR GLASS. 27 1/2" X 35" VINYL WINDOW W/ 1" INSULATED CLEAR GLASS. W4 W3 W5 W6 W7 W8 NOTES: 1.EXTERIOR WINDOWS TO BE PRE-FINISHED , COLOR: DESERT SAND 2.BLACK OUT GLASS IN WINDOWS IN GYM EQUIP. #114 & #115 3.WINDOW MANUFACTURER: ALLIANCE OR OWNER APPROVED EQUAL W9 04/23/18 04/23/18 04/23/18 04/23/18 04/23/18 04/23/18 04/23/18 04/20/18 M.001 MECHANICAL COVER SHEET ROHASCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT HVAC SYMBOLS LEGENDHVAC GENERAL NOTES FIELD VERIFY ALL CONDITIONS HVAC ABBREVIATIONS CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 M.100 MAIN LEVEL MECHANICAL PLAN ROHAS Kitchen Pantry 129 Utility Rm 123 Kitchen 126 Closet 140 Director's Office 101 Vestibule 100 Gym 116Toddler 1 121 Toddler 2 119 Central Corridor 133 Lobby 111 Reception 102Conf. Room. 118 Closet 122 Infant 1 124 Infant 2 125 Adult B.F. Toilet 1 103 Child Toilet 2 105 Gym Childs Toilet 117 Childs Toilet 7 138 Pre-School 2 112 Pre-K 2 137 Outdoor Toy Storage 136 Childs Toilet 6 135 Pre-K 1 134 Closet 139 Corridor 1 132 Pre-School 1 109 Laundry Room 128 Childs Toilet 5 110 Varsity Pre-Shool 106 Childs Toilet 4 108 Car Seat Sto. I.T. Closet 130 Childs Toilet 9 120 Childs B.F. Toilet 8 113 Staff Lounge 127 Young Pre-School 104 Childs Toilet 3 107 Stairs Gym Equip. 114 Gym Equip. 115 PLAN KEYED NOTES MAIN LEVEL MECHANICAL PLAN 3/16" = 1'-0" 04/20/18 M.200 UPPER LEVEL MECHANICAL PLAN ROHASCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT EQUIPMENT PLATFORM Attic Space #1 Attic Space #2 Attic Space #3 Attic Space #4 Attic Space #5 PLAN KEYED NOTES UPPER LEVEL MECHANICAL PLAN 3/16" = 1'-0" 04/20/18 M.300 MECHANICAL SCHEDULES ROHASCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT EXHAUST FAN SCHEDULE DIFFUSER / REGISTER / GRILLE SCHEDULE GAS FIRED FURNACE SCHEDULE HEAT PUMP UNIT SCHEDULE LOUVER / INTAKE SCHEDULE COOLING COIL SCHEDULE FLEX DUCT SIZE BUILDING AIR BALANCE SCHEDULE THERMOSTAT SCHEDULE 04/20/18 M.400 MECHANICAL DETAILS ROHASCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 9 RECTANGULAR BRANCH CONNECT NTS 10 ROUND BRANCH CONNECTION NTS 2 LOUVER- MOUNTING DETAIL NTS 4 TYPICAL AIR HANDLING UNIT DETAIL NTS 5 CONDENSER TIE-DOWN DETAIL NTS 3 TYPICAL SQUARE VANED DUCT DETAIL NTS 6 TYPICAL DUCT TRANSITION DETAIL NTS 8 TYPICAL DUCT STRAP HANGER DETAIL NTS7TYPICAL DUCT RADIUS DETAIL NTS 1 AHU CONDENSATE DRAIN DETAIL NTS 11 ROOF CAP DETAIL NTS 12 DRYER EXHAUST VENT DETAIL NTS 13 REFRIGERANT LINES DETAIL NTS 14 CONCENTRIC VENT DETAIL NTS 04/20/18 M.500 MECHANICAL SPECIFICATIONS ROHASCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT SECTION 23 0000 - HVAC “”“” ” CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 P.001 PLUMBING COVER SHEET PHROH GENERAL PLUMBING NOTESPLUMBING SYMBOLSPLUMBING ABBREVIATIONS CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 P.002 SLAB DIMENSION PLAN PHROHSLAB DIMENSION PLAN 1/8" = 1'-0" Kitchen Pantry 129 Utility Rm 123 Kitchen 126 Closet 140 Director's Office 101 Vestibule 100 Gym 116 Gym Equip. 114 Toddler 1 121Toddler 2 119 Central Corridor 133 Lobby 111 Reception 102Conference Rm. 118Closet 122 Infant 1 124 Infant 2 125 Adult B.F. Toilet 1 103 Child Toilet 2 105 Gym Childs Toilet 117 Childs Toilet 7 138 Pre-School 2 112 Pre-K 2 137 Outdoor Toy Storage 136 Childs Toilet 6 135 Pre-K 1 134 Closet 139 Corridor 1 132 Pre-School 1 109 Laundry Room 128 Childs Toilet 5 110 Varsity Pre-School 106 Young Pre-School 104 Childs Toilet 4 108 Childs Toilet 3 107 I.T. Closet 130 Childs B.F. Toilet 8 113 Childs Toilet 9 120 Gym Equip. 115 Car Seat Sto. Staff Lounge 127 Stairs CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 P.100 UNDERGROUND PIPING PLAN PHROH Kitchen Pantry 129 Utility Rm 123 Kitchen 126 Closet 140 Director's Office 101 Vestibule 100 Gym 116 Gym Equip. 114 Toddler 1 121Toddler 2 119 Central Corridor 133 Lobby 111 Reception 102Conference Rm. 118Closet 122 Infant 1 124 Infant 2 125 Adult B.F. Toilet 1 103 Child Toilet 2 105 Gym Childs Toilet 117 Childs Toilet 7 138 Pre-School 2 112 Pre-K 2 137 Outdoor Toy Storage 136 Childs Toilet 6 135 Pre-K 1 134 Closet 140 Corridor 1 132 Pre-School 1 109 Laundry Room 128 Childs Toilet 5 110 Varsity Pre-School 106 Young Pre-School 104 Childs Toilet 4 108 Childs Toilet 3 107 I.T. Closet 130 Childs B.F. Toilet 8 113 Childs Toilet 9 120 Gym Equip. 115 Car Seat Sto. Staff Lounge 127 KEY NOTES UNDERGROUND PIPING PLAN 3/16" = 1'-0" Stairs 139 Hall 131 CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 P.101 MAIN LEVEL PIPING PLAN PHROH Kitchen Pantry 129 Utility Rm 123 Kitchen 126 Closet 140 Director's Office 101 Vestibule 100 Gym 116 Gym Equip. 114 Toddler 1 121Toddler 2 119 Staff Lounge 127 Central Corridor 133 Lobby 111 Reception 102 Conference Rm. 118Closet 122 Infant 1 124 Infant 2 125 Adult B.F. Toilet 1 103 Child Toilet 2 105 Gym Childs Toilet 117 Childs Toilet 7 138 Pre-School 2 112 Pre-K 2 137 Outdoor Toy Storage 136 Childs Toilet 6 135 Pre-K 1 134 Corridor 1 132 Pre-School 1 109 Laundry Rm. 128 Childs Toilet 5 110 Varsity Pre-School 106 Young Pre-School 104 Childs Toilet 4 108 Childs Toilet 3 107 Car Seat Sto. I.T. Closet 130 Childs B.F. Toilet 8 113 Childs Toilet 9 120 Gym Equip. 115 KEY NOTES MAIN LEVEL PIPING PLAN 3/16" = 1'-0" Closet 140 Stairs 139 Hall 131 CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 P.200 WASTE AND VENT RISER DIAGRAM PHROH KEY NOTES WASTE AND VENT RISER DIAGRAM NTSUPPER LEVEL PIPING PLAN 1/4" = 1'-0" CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 P.300 PLUMBING SCHEDULES PHROH PIPING TYPES: EXPANSION TANK SCHEDULE DOMESTIC WATER HEATER SCHEDULE WATER HEATER SIZING CALCULATION BACKFLOW DEVICE SCHEDULE WATER SHOCK ARRESTOR SIZING CHART DRAINAGE FIXTURE UNITS SCHEDULE DOMESTIC WATER SUPPLY FIXTURE UNITS GREASE INTERCEPTOR CALCULATIONS GREASE INTERCEPTOR PLUMBING FIXTURE / COMPONENT SCHEDULE CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 P.400 PLUMBING DETAILS PHROH12WALL HYDRANT INSTALLATION DETAIL NTS EXTERIOR CLEANOUT (COTG)INTERIOR FLOOR CLEANOUT (FCO) 7 CLEANOUT DETAILS NTS 8 FLOOR DRAIN DETAIL NTS 3 INDIRECT DRAIN DETAIL NTS2SANITARY CLEAN OUT OUTSIDE BUILDING NTS 4 WALL CLEAN OUT DETAIL NTS 5 FLOOR SINK DETAIL NTS 10 GREASE INTERCEPTOR DETAIL NTS 6 THERMAL MIXING VALVE DETAIL NTS 11 FLOOR DRAIN W/ TRAP PRIMER DETAILNTS 1 WATER HAMMER ARRESTORS DETAIL NTS 9 WATER SERVICE ENTRANCE DETAIL NTS CHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 04/20/18 P.401 PLUMBING DETAILS PHROH6WATER HEATER DETAIL NTS 4 WATER MANIFOLD DETAIL NTS 5 WASHING MACHINE HOOK-UP NTS 2 EXPANSION TANK DETAIL NTS1IN-LINE CIRCULATING PUMP DETAIL NTS 3 PIPE HANGER DETAIL NTS 2"CW 04/20/18 E.000 ELECTRICAL COVER SHEET MSDMSCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT )'0'4#.016'5 POWER AND DIAGRAMS LIGHTING FIRE DETECTION AND ALARM TELECOMMUNICATION SECURITY ABBREVIATIONS GENERAL NOTES · ” · · · · · · · · · · · · · ·”” ” · · ·” · LOW VOLTAGE NOTES LIGHTING FIXTURE SCHEDULE 04/20/18 E.010 ELECTRICAL SITE PLAN MSDMSCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT ELECTRICAL SITE PLAN 1" = 20' KEYED NOTES · · 04/20/18 E.100 ELECTRICAL PLAN - LIGHTING MSDMSCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT ELECTRICAL PLAN - LIGHTING 3/16" = 1'-0" KEYED NOTES Pre-School 2Pre-K 2 Staff Lounge Pre-K 1 Pre-School 1 Laundry Rm. Varsity Corridor 1 Toddler 1 Gym Infant 1Infant 2 Young Pre-School Central Corridor Vestibule Childs Toilet 4 Childs Toilet 3 Child Toilet 5 Childs Toilet 7 Childs Toilet 9 Childs Toilet 8 Toddler 2 Childs Toilet 6 Gym Child Toilet Closet Gym Equip.Gym Equip. Directors Office Utility Rm. Kitchen Pantry Kitchen Outdoor Toy Storage Closet Adult B.F. Toilet 1 Stair Child Toilet 2 Lobby Reception Conf.Rm. Closet 109 110 134 135 136 138 113 112 132 128 106 108 104 125 124 122 118 102 126 129123 101 100111 117 116 115114 121 120 127 133 103 105 107 119 139 137 140 Hall 131 I.T. Closet 130 140 04/20/18 E.101 ELECTRICAL PLAN - POWER MSDMSCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT ELECTRICAL PLAN - POWER 3/16" = 1'-0" KEYED NOTES Pre-School 2 Pre-K 2 Staff Lounge Pre-K 1 Pre-School 1 Laundry Rm. Varsity Pre-School Corridor 1 Toddler 1 Gym Infant 1Infant 2 Young Pre-School Central Corridor Vestibule Childs Toilet 4 Childs Toilet 3 Child Toilet 5 Childs Toilet 7 Childs Toilet 9 Childs Toilet 8 Toddler 2 Childs Toilet 6 Gym Child Toilet Closet Gym Equip.Gym Equip. Directors Office Utility Rm. Kitchen Pantry Kitchen Outdoor Toy Storage Closet Adult B.F. Toilet 1 Stair Child Toilet 2 Lobby Reception Conf.Rm. Closet 109 110 134 135 136 138 113 112 132 128 106 108 104 125 124 122 118 102 126 129123 101 100 111 117 116 115114 121 120 127 133 103105 107 119 139 137 140 Hall 131 I.T. Closet 130 140 04/20/18 E.102 ELECTRICAL PLAN - FIRE ALARM MSDMSCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT ELECTRICAL PLAN - FIRE ALARM 3/16" = 1'-0"1 DETAIL - FIRE ALARM RISER NTS 04/20/18 E.103 ELECTRICAL PLAN - EQUIPMENT PLATFORM MSDMSCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT ELECTRICAL PLAN - EQUIPMENT PLATFORM 3/16" = 1'-0" KEYED NOTES GENERAL NOTES 04/20/18 E.201 ELECTRCIAL DETAILS MSDMSCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT 4 COMMUNICATIONS DETAIL NTS 3 MOUNTING HEIGHTS NTS1ONE LINE DIAGRAM NTS 6 DETAIL - CLASSRMN. SWITCH BANK NTS 7 DETAIL - RECEPTION SWITCH BANK NTS 8 LIGHTING CONTROLS - EXTERIOR NTS 9 LIGHTING CONTROLS - INTERIOR NTS KEYED NOTES 5 MAIN SERVICE ENTRANCE GROUND CONNECTIONS N.T.S NOTES 2 COMMS/DATA WIRING DIAGRAM NTS 04/20/18 E.202 PANEL SCHEDULES MSDMSCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT GENERAL NOTES SHORT CIRCUIT CURRENT RATING ” Voltage Drop Calculations 04/20/18 E.204 ELECTRICAL SPECIFICATIONS MSDMSCHECKED: PROJECT NO: DATE: REVISIONS NO DATE REMARKS CORPORATE SEAL: DRAWN: SEAL: THIS DOCUMENT IS "NOT FOR CONSTRUCTION" UNLESS THE ARCHITECT OR ENGINEER'S SIGNATURE AND SEAL APPEAR BELOW. RAINBOW CHILD CARE CENTER C-PROTOTYPE 95 CENTENNIAL PARKWAY SPOUT SPRINGS, NC 28326 2017.0643 COPYRIGHT cP-0215 2018 INTERPLAN PLLC RESERVES COPYRIGHT & OTHER RIGHTS RESTRICTING THESE DOCUMENTS TO THE ORIGINAL SITE OR PURPOSE FOR WHICH THEY WERE PREPARED. REPRODUCTIONS, CHANGES OR ASSIGNMENTS ARE PROHIBITED.604 COURTLAND STREET SUITE 100 ORLANDO, FLORIDA 32804 PH 407.645.5008 FX 407.629.9124 ARCHITECTURE ENGINEERING INTERIOR DESIGN PROJECT MANAGEMENT DIVISION 16000 - ELECTRICAL SPECIFICATIONS