Loading...
9-12 Triple Wide - RF1P9F With Bearing at Overhang 1 Side CCB37711Job 91192 Truss CCB37711 Truss Type CAPE COD Qty 1 Ply 1 Commodore 315 NC Ref. #3157426 R41P9F (WITH BEARING AT OH 1 SIDE) 8.130 e Dec 12 2017 MiTek Industries, Inc. Thu Mar 8 10:48:52 2018 Page 1 of 2Universal Forest Products Inc., Grand Rapids, MI 49525, Weston Gorby T1 T1 W1 B1 W1 W2 B1 T2 T3 B2 T2 T3 1 2 3 4 5 6 7 8 9 10 11 15 14 13 12 16 17 18 196x12 MTH18D 8x12 MTH18D MTH18KMTH18K 0-5-151-8-09-1-216-6-60-1-89-10-51 -1 1 -7 1 2 -4 -8 0 -3 -0 1 2 -1 -1 3 2 6 -8 -1 2 3-7-5 0-3-0 15-11-15 25-1-12 0-3-14 0-3-14 1-0-12 Opt. Cut Off 1-0-00-4-100-11-4 8-0-0 5-8-7 13-8-14 5-8-7 8-0-0 0-11-4 41-1-12 0-11-4 0-11-4 20-6-14 20-6-14 0-11-4 9.00 12 Plate Offsets (X,Y)-- [1:0-9-3,0-0-0], [2:0-0-11,0-0-0], [3:0-0-11,0-1-2], [9:0-0-11,0-1-2], [10:0-0-11,0-0-0], [11:0-1-3,0-4-0], [11:0-4-10,0-1-3] SPACING-:2-0-0 LOADING (psf) TCLL (Ground Snow=30.0) TCDL BCLL BCDL 23.1 7.0 0.0 * 10.0 SPACING-:1-4-0 LOADING (psf) TCLL (Ground Snow=45.0) TCDL BCLL BCDL 34.7 10.5 0.0 * 15.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2009/TPI2007 CSI. TC BC WB Matrix-R 0.94 0.62 0.52 DEFL. Vert(LL) Vert(TL) Horz(TL) Attic in 0.60 -0.55 0.02 -0.31 (loc) 1-15 1-15 11 14-15 l/defl >288 >315 n/a 452 L/d 240 180 n/a 360 PLATES MT20 MT18HS Weight: 277 lb FT = 0% GRIP 137/130 137/130 LUMBER- TOP CHORD 1-1/2X9-1/4 LP-LSL TC 1.75E *Except* T2: 2x8 SP No.1 or 2x8 SPF No.2 T3: 2x6 SP No.1 or 2x6 SPF No.2 BOT CHORD 2x10 SP DSS WEBS 2x4 SP No.2 or 2x4 SPF No.2 *Except* W2: 2x8 SP No.2 or 2x8 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-3-12 oc bracing. WEBS 2 Rows at 1/3 pts 5-7 REACTIONS.(lb/size) 1=1331/0-3-8 (min. 0-2-1), 11=1345/0-3-8 (min. 0-2-2), 14=510/0-3-0 (min. 0-1-8), 13=420/0-3-0 (min. 0-1-8) Max Horz 1=-1083(LC 7) Max Uplift1=-1011(LC 9), 11=-1018(LC 9), 14=-471(LC 9), 13=-435(LC 7) Max Grav 1=1331(LC 1), 11=1345(LC 1), 14=1256(LC 13), 13=1206(LC 13) FORCES.(lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-1489/1126, 2-3=-1304/1140, 3-4=-1357/1413, 4-5=-1166/1433, 5-16=-459/350, 6-16=-347/370 , 6-17=-340/371, 7-17=-465/351, 7-8=-1166/1432, 8-9=-1357/1412, 9-10=-1304/1121, 10-11=-1375/1113 BOT CHORD 1-18=-645/1057, 15-18=-645/1057, 14-15=-640/1055, 13-14=-640/1055, 12-13=-640/1055, 12-19=-642/1057, 11-19=-642/1057 WEBS 9-12=-534/900, 3-15=-564/930, 5-7=-874/1420 REQUIRED FIELD JOINT CONNECTIONS - Maximum Compression (lb)/ Tension (lb)/ Shear (lb)/ Moment (lb-in) 4=1256/1421/261/0, 5=885/1432/72/0, 6=272/373/316/0, 7=888/1436/72/0, 8=1255/1421/241/0, 12=534/900/0/0, 13=640/1055/687/0, 14=640/1055/687/0, 15=564/930/0/0 - Verify design parameters and READ NOTES an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult BCSI 1-06 from the Wood Truss Council of America and Truss Plate Institute Recommendation available from WTCA, 6300 Enterprise LN, Madison, WI 53719 J:\support\MitekSupp\templates\ufp.tpe WARNING C Universal Forest Products, Inc. 2801 EAST BELTLINE RD, NE PHONE (616)-364-6161 FAX (616)-365-0060 GRAND RAPIDS, MI 49525 This component has only been designed for the loads noted on this drawing. Construction and lifting forces have not been considered. The builder is responsible for lifting methods and system design. Builder responsibilities are defined under TPI1. This design is based only upon parameters shown, and is for The professional engineering seal indicates that a licensed professional has reviewed the design under the standards referenced within this document, not necessarily the current state building code. The engineering seal is not an approval to use in a specific state. The final determination on whether a truss design is acceptable under the locally adopted building code rest with the building official or designated appointee. Truss shall not be cut or modified without approval of the truss design engineer. Copyright 2018 Universal Forest Products, Inc. All Rights Reserved 3/4" dia hole (See Note #16) 3/4" dia hole (See Note #16) Signature is invalid Consult UFP Engineering for original document. 3/8/2018 Job 91192 Truss CCB37711 Truss Type CAPE COD Qty 1 Ply 1 Commodore 315 NC Ref. #3157426 R41P9F (WITH BEARING AT OH 1 SIDE) 8.130 e Dec 12 2017 MiTek Industries, Inc. Thu Mar 8 10:48:52 2018 Page 2 of 2Universal Forest Products Inc., Grand Rapids, MI 49525, Weston Gorby CCopyright 2018 Universal Forest Products, Inc. All Rights Reserved - Verify design parameters and READ NOTES an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult BCSI 1-06 from the Wood Truss Council of America and Truss Plate Institute Recommendation available from WTCA, 6300 Enterprise LN, Madison, WI 53719 J:\support\MitekSupp\templates\ufp.tpe WARNING Universal Forest Products, Inc. 2801 EAST BELTLINE RD, NE PHONE (616)-364-6161 FAX (616)-365-0060 GRAND RAPIDS, MI 49525 This component has only been designed for the loads noted on this drawing. Construction and lifting forces have not been considered. The builder is responsible for lifting methods and system design. Builder responsibilities are defined under TPI1. This design is based only upon parameters shown, and is for The professional engineering seal indicates that a licensed professional has reviewed the design under the standards referenced within this document, not necessarily the current state building code. The engineering seal is not an approval to use in a specific state. The final determination on whether a truss design is acceptable under the locally adopted building code rest with the building official or designated appointee. Truss shall not be cut or modified without approval of the truss design engineer. NOTES- 1) Wind: ASCE 7-05; 130mph @24in o.c.; TCDL=2.8psf; BCDL=4.0psf; (Alt. 150mph @16in o.c.; TCDL=4.2psf; BCDL=6.0psf); h=30ft; Cat. II; Exp C; enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-05; Pg=30.0 psf (ground snow); Ps=23.1 psf (roof snow); Category II; Exp C; Partially Exp.; Ct=1.1 3) Roof design snow load has been reduced to account for slope. 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) See HINGE PLATE DETAILS for plate placement. 8) Provisions must be made to prevent lateral movement of hinged member(s) during transportation. 9) All additional member connections shall be provided by others for forces as indicated. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 12) Ceiling dead load (5.0 psf) on member(s). 3-5, 7-9, 5-7 13) Bottom chord live load (40.0 psf) and additional bottom chord dead load (0.0 psf) applied only to room. 14-15, 13-14, 12-13 14) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1011 lb uplift at joint 1, 1018 lb uplift at joint 11, 471 lb uplift at joint 14 and 435 lb uplift at joint 13. 15) This truss has been designed in accordance with the 2009 IBC Section 2303.4.6, 2009 IRC Section 802.10.2. 16) This truss design allows for the following max. bolt holes along the member c/lines spaced a min. of 0-6-0 apart: 0.750in in the bottom chord. 17) Attic room checked for L/360 deflection. 18) Take precaution to keep the chords in plane, any bending or twisting of the hinge plate must be repaired before the building is put into service. 19) The field-installed members are an integral part of the truss design. Retain a design professional to specify final field connections and temporary supports. All field-installed members must be properly fastened prior to applying any loading to the truss. This design anticipates the final set position. 20) Based on: CCB37709 21) Revision: Removed bottom chord scabs, added hole note. UNIVERSAL FOREST PRODUCTS, INC. Corporate Engineering 2801 East Beltline, NE Grand Rapids, MI 49525-9736 (616) 364-6161 Fax (616) 365-0060 ufpi.com Job Truss Customer MFG 91192 CCB37711 COMMODORE 315 The professional engineering seal indicates that a licensed professional has reviewed the design under the standards referenced within this document, not necessarily the current state building code. The engineering seal is not an approval to use a design in a specific state. The final determination on whether a truss design is acceptable under the locally adopted building code rest with the building official or designated appointee. 3/8/2018