18-50040822, Benhaven Elem. Fixed SuppressionHarnett c4U N T Yc s x Plan Review, Inspection, and Permit Fees Application Number $200.00 $100.00 $100.00 $50.00 $35.00 + $2.00 per device $35.00 + $2.00 per nozzle $75.00 $100.00 $50.00 $100.00 $150.00 $250.00 $35.00 + 2.00 per head $50.00 $50.00 $75.00 18-50040822 ❑ Explosive Material (90 Days) ❑ Explosive Materials (72 Hours) ❑ Fireworks Public Display ❑ Final Inspection ❑ Fire Alarm Testing D Fixed Fire Suppression ❑ Insecticide Fog/Fumigation ❑ Pipe Test/UST/AGST ❑ Plans up to 5000 sq ft ❑ Plans 5001 sq ft to 10,000 sq ft ❑ Plans 10,001 sq ft to 25,000 sq ft ❑ Plans 25,001 sq ft and over ❑ Sprinkler Certification Test ❑ Standpipe Testing ❑ Special Assembly (ie. amusement buildings, carnivals, fairs) Tents/Canopies/Air Supported Structure $100.00 Tank Installation (charge for each tank) $100.00 ❑ Tank Removal (charge for each tank) 18 Total Devices/Heads Total Cost Code Enforcement Official Banks Wallace 35.00 36.00 71.00 5/7/2018 May 7, 2018 Michael Moody 540 Civic Blvd Suite 105 Raleigh, NC 27610 r Em ty Services spartwwrtt W -hafn ttarij Fire Marshal Division Re: Benhaven Elementary School 445 Olive Far n Rd Sanford, NC 27330 Application Number 18-50040822 Mr. Moody, Thank you for submitting the plans for the hood system. The plans have been carefully reviewed by a qualified code enforcement official to examine for compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • Commercial cooking equipment. o Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. • Acceptance Test o An acceptance test will be conducted by the Fire Marshal's office once system has been installed and pre -tested. o Installation shall be per architectural and system submittals and compliant with NFPA-17A. • Manual system operation o A manual actuation device shall be located at or near a means of egress from the cooking area, a minimum of 10 feet (3048 mm) and a maximum of 20 feet (6096 mm) from the kitchen exhaust system. The manual Harnett C 0 U N T Y ' Ery"envy Serw es Department WWWA&rnemorq actuation device shall be located a minimum of 4.5 feet (1372 mm) and a maximum of 5 feet (1524 mm) above the floor. The manual actuation shall require a maximum force of 40 pounds (178 N) and a maximum movement of 14 inches (356 mm) to actuate the fire suppression system. • System Interconnection o The actuation of the fire suppression system shall automatically shut down the fuel or electrical power supply to the cooking equipment. The fuel and electrical supply reset shall be manual. • Notes o Please schedule all fire inspections through the Fire Marshal's Office. o Contact Number 910-893-0743. o Please provide system certification certificate from installing contractor. Thank you again for submitting the plans for the hood system. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office. Again, thank you and we look forward to working with you during the construction period! Sincerely, ; D. Banks Wallace Chief Deputy Fire Marshal ff =0*0 Sit Co A K K 10 Wcation for Plan Review Application # Date Received: Received By: C, ,57 _ Name of Project: Physical Address of Project. Plans Submitted By: Project Phone: Contact Person/Address: NC 2-73-S L-�-o t i t3 to E <1 t1 �>l Contact Email: TZ, -t _c"r, e`'t Contact Phone: q Contractor's Namelinfo: rte, , % e_ Contractor's Phone: ( )- - Lt -z 0 • Plans that are submitted will be reviewed as quickly as possible with an average time of review between 7-10 working days. Status checks may be conducted on plan reviews by visiting the website http://hteweb.harnett.org/Click2GovBP/index.osp or by calling the Harnett County Central Permitting Office (910-893-7525, Option #2), or the Harnett County Fire Marshal's Office (910-893-7580). Approved plans must be picked up from the Central Permitting Office and all fees paid before any required inspections can be conducted. Hood # 2 (BACK) Job # 3054208 E'er a Madel: ND -2 -PSP -F Sizes 54'x24' Length; 15' 0' r I I 3 CEI Q° — -- — — — F- O O Hood # 1 (FRONT) Job # 3054208 Model: 0 ND -2 -PSP -F Slool 54'x24' Length) 15' 0' O UL 300 N❑❑D ❑IRE SUPPRESSION SYSTEM PULL STATION DETAIL u srxarcw m E ceaa. s re OFF aFFSEii W BEND rcu . rucm pxaaawx Be. nc� le' -IB• A VE lel-- aV IX Frrai0 c VIrX lOOPL 000E ScaEv Xmas ar z D'L axo a oawX v `ocata^ ..,a zo• o� o gra wa or .a.ss R1=1­wr Srnrmx Sew BE BDh ais , nrx wrwXn noX. FIRE SYSTEM OPERATION 1. Kitchen hood shall be constmctedand installed per NFPA 96. 2. Hood Electrical Control Panel and Fire Control S}'sten, shall shut down kitchen hood makeup air fan upon activation of fire extinguishing system. Kitchen hood exhaust fan shall continue to operate or power oa neon activation. The hood electrical panel and fire system will provide interlock for automatic operation of fire suppression system with: a. Mechanical gas valve (installed by mechanical' plumbing contractor) b. Hood sltpply and exhnust fan (wiring by elect E. Remote manual pull station (by hood fire system dist,) d. Fire alarm system notification (by Fire alarm Contractor or electrician) 2. See Hood details for rhawings 3. All exposedpiping with fire suppression system shall be coeered with a a chrome sleeve. 4. Mechanical commanr shall install conduit in wall for manual pull station. Pull Station shall be located at or near a means of egress from the cooking area. 5. Fire s,rppression system shflll be in accordance wish UL 300. NOTES - FIELD PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC, - MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. - IF APPLICABLE, PRE -PIPED CHARBROILER DROPS ARE SHIPPED LOOSE, - FACTORY PIPING EXTENDS A MAXIMUM OF 6' ABOVE THE TOP OF THE HOOD - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE - THIS FIRE SYSTEM COMPLIES WITH U.L, 300 REQUIREMENTS Job #1 3054208 Job Name BENHAVEN ELEMENTARY SCHOOL-SANFORD (No Fans) Drawn By System Size; ANSUL-3.0/3.0 Total FP required, 18 Hood # 1 15' 0.00' Long x 54' Wide x 24' High Riser # 1 Size 14' x 14' Riser # 2 Size; 14' x 14' Hood # 1 Metal Blow -OFF Caps included. Hood # 2 15' 0.00' Long x 54' Wide x 24' High Riser # 1 Size 14' x 14° Riser # 2 Size 14' x 14' Hood # 2 Metal Blow -Off Caps included, LEGEND - FIRE CABINET ANSUL SYSTEM 1 1.5 GALLON TANK 1B 3 GALLON TANK 2 OEM AUTOMAN RELEASE 3 OEM REGULATED RELEASE 4 OEM REGULATED ACTUATOR 5 ANSULEX LIQUID AGENT (3 GAL.) 6 ANSULEX LIQUID AGENT (IS GAL.) 7 CARTRIDGE (101-20) 8 CARTRIDGE (101-10) 9 CARTRIDGE (101-30) 9A CARTRIDGE <LT -A-101-30) 9B DOUBLE TANK CARTRIDGE 10 TEST LINK 11 DOUBLE MICROSWITCH 12 HOSE ASSEMBLY 1100 DUCT NOZZLE (430913) 2W DUCT NOZZLE (419337) 1W NUZZLE ASSEMBLY (419336) IF NOZZLE ASSEMBLY (419333) 1N NUZZLE ASSEMBLY (419335) 1/2N NOZZLE ASSEMBLY (419334) 3N NOZZLE ASSEMBLY (419338) 245 NOZZLE ASSEMBLY (419340) 230 NOZZLE ASSEMBLY (419339) 2120 NOZZLE ASSEMBLY (419343) 290 NOZZLE ASSEMBLY (419342) 260 NOZZLE ASSEMBLY (419341) 28 DETECTOR BRACKET All Fire System Piping will be 3/8' schedule 40 black iron NO FIRE CODE 90411.2 System Interconnection: The Actuation of the fire extinguishing system shall automatically shut dawn the fuel or electrical power supply to the cooking equipment The Fuel. and electrical supply reset shall be mnnuaL FUEL SHUTOFF IN FIRE CONDITION GAS AND ELECTRICAL TO COOKING APPLIANCES REVISIONS 'Lee! ®®� 6 O C q O LL z I J O U l- ¢ — z w w _J w z w ¢ z W PQ DATE: 7/13/2017 DWG.#: 3054208 DRAWN re 36 BY: 9 SCALE: 3/4" = 1'-0" MASTER DRAWING SHEET NO. 4