1850043022, Overhills Dining AdditionPlan Review, Inspection, and Permit Fees
Application Number :1850043022
$200.00 Explosive Material (90 Days)$ -
$100.00 Explosive Materials (72 Hours)$ -
$100.00 Fireworks Public Display $ -
$50.00 Final Inspection $ 50.00
$35.00 + $2.00 per device Fire Alarm Testing $ -
$35.00 + $2.00 per nozzle Fixed Fire Suppression $ -
$75.00 Insecticide Fog/Fumigation $ -
$100.00 Pipe Test/UST/AGST $ -
$50.00 Plans up to 5000 sq ft $ 50.00
$100.00 Plans 5001 sq ft to 10,000 sq ft $ -
$150.00 Plans 10,001 sq ft to 25,000 sq ft $ -
$250.00 Plans 25,001 sq ft and over $ -
$35.00 + 2.00 per head Sprinkler Certification Test $ -
$50.00 Standpipe Testing $ -
$50.00 Special Assembly
(ie. amusement buildings, carnivals, fairs)$ -
$75.00 Tents/Canopies/Air Supported Structure $ -
$100.00 Tank Installation (charge for each tank)$ -
$100.00 Tank Removal (charge for each tank)$ -
Total Devices/Heads $ -
Total Cost $ 100.00
Code Enforcement Official Rodney Daniels 5/3/2018
Fire Marshal Division
May 3, 2018
Bryant Braddy
100 Arendell Ave.
Zebulon, NC 27597
Re: Overhills Dinning Hall Addition
2495 Ray Road
Spring Lake, NC 28390
Application Number 18-50043022
Mr. Braddy,
Thank you for submitting the plans for the dining room expansion. The plans have been
carefully reviewed by a qualified code enforcement official to examine for compliance
with the North Carolina Fire Prevention Code and all other fire protection regulatory
documents. There are some items that were found during the plan review process that
need to be addressed before a final inspection of the new facility can be given. These
items are outlined and described below.
906.1 Fire Extinguishers
o Minimum of (1) 2A10:BC fire extinguisher shall be installed not to exceed
75’ distance of travel.
o All Fire extinguishers shall be properly mounted and tagged by a fire
extinguisher company.
1006.1 Means of Egress Illumination
o The means of egress, including the exit discharge, shall be illuminated at
all time the building space is served by the means of egress is occupied.
o Means of egress consist of three separate and distinct parts: the
exit access, the exit and the exit discharge.
o The means of egress illumination shall not be less than 1 foot-candle at
the walking surface.
105.7.1 Automatic fire-extinguishing systems.
o A construction permit is required for the fire sprinkler system installation
before any such work commences. Submit complete construction
documents that include the hydraulic calculations for the system. The
system shall also be designed consistent with the architectural design
documents and specifications. Construction documents shall include
detail as described in NFPA 13 standard for automatic sprinkler system
installation. Contractor must obtain construction permit for the fire
sprinkler system before commencement of any work.
A rough in inspection is required.
A final acceptance test is required.
105.7.5 Fire alarm construction permits.
o A construction permit is required for the fire alarm installation. Submit
complete shop drawings consistent with the architectural design
documents and specifications. Shop drawings shall include detail as
described in Section 907.1.2 of the NC State Fire Code. Contractor must
obtain the construction permit for the fire alarm system before
commencement of any work.
A rough in inspection is required.
A final acceptance test is required. (100%)
901.2.1 State of Compliance.
o Before requesting final approval of the installation, where required by
the fire code official, the installing contactor shall furnish a written
statement to the fire code official that the subject fire protection system
has been installed in accordance with the manufacture’s specifications
and the appropriate installation standard. Any deviations from the design
standards shall be noted and copies of the approvals for such deviations
shall be attached to the written statement.
907.4.1 Duct Smoke detectors.
o Smoke detectors installed in ducts shall be listed for the air velocity,
temperature and humidity present in the duct. Duct smoke detectors
shall be connected to the building’s fire alarm control unit when a fire
alarm system is required by Section 907.2. Activation of a duct smoke
detector shall initiate a visible and audible supervisory signal at a
constantly attended location and shall perform the intended fire safety
function in accordance with this code and the International Mechanical
Code. Duct smoke detectors shall not be used as a substitute for required
open area detection.
703.5 Identification
o Walls and partitions required to have protected openings shall be
permanently identified with signs or stencils. (Example “2- hour Fire
Barrier Protect All Openings”)
Notes
o New exit will require panic hardware.
o A final fire inspection is required.
o Schedule all fire inspections through the Fire Marshal’s Office.
(919)893-0743
Thank you again for submitting the plans for the expansion. Please review the plans and
adhere to any notes and alterations that were made in addition to the original drawings.
These remarks are for the plans that were submitted and its original intent. These
remarks do not apply if the original intent changes or what was submitted on the above
date changes. If you have any questions, please do not hesitate to call this office.
Sincerely,
Rodney Daniels
Rodney Daniels
Fire Marshal
12345678910111213EXIT DEVICES AT INTERIOR DOORS TO BE CLASSROOM FUNCTION WITH LEVERPROVIDE 4" WIDE STEEL JAMBS FOR DOORS ABUTTING STEEL COLUMNS AND SPECIAL CONDITIONS AS SHOWNALL DOORS TO RECEIVE HINGES AS SPECIFIEDALL DOORS TO RECEIVE WALL OR OVERHEAD STOPS TO SUIT CONDITION OF USE. DOORS WITH MAGNETIC HOLD OPENS TO RECEIVE FLOOR STOPS.PROVIDE CLOSERS WITH BACKSTOPS EXTERIOR DOORS AND TO SUIT CONDITION OF USEALL STEEL FRAMES TO BE PROVIDED WITH SILENCERSEXTERIOR DOORS TO BE PROVIDED WITH WEATHERSTRIPPING AND THRESHOLDSEXIT DEVICES TO BE PROVIDED WITH CYLINDERSAT PAIRS OF DOORS, PULL SIDE, PROVIDE PULL OR LEVER RIGHT SIDE ONLYNOTES AND GENERAL AND SPECIAL HARDWARE REQUIREDALUMINUM DOORS ‐ SEE SPECIFICATIONS FOR HARDWARE NOT INDICATED ABOVEPROVIDE CYLINDERS FOR KEYED MULLIONS SUPPLIED BY ALUMINUM DOOR SUPPLIERPROVIDE SOLID WOOD BLOCKING FOR DOOR STOPS AND HOLD OPEN DEVICESEXIT DEVICES AT EXTERIOR DOORS TO BE NL WITH PULLAREA FLOOR BASE WALLS CEILING CLG HEIGHT REMARKSNEW DININGTERRAZZO4" RUBBERPAINTED CMU/BRICKACOUSTICAL TILEVAIRESEXISTING DININGLCT4" RUBBERPAINTED CMUETRETRREPAIR/REPLACE ALL DISTURBED SUFACES TO NEW CONDITIONNEW CORRIDORTERRAZZO4" RUBBERPAINTED CMU/BRICKACOUSTICAL TILE10'‐4"REPAIR/REPLACE ALL DISTURBED SUFACES TO NEW CONDITIONMECHANICALSEALED CONCRETE4" RUBBERPAINTED CMUNONEVAIRESEXISTING KITCHEN ETR ETR PAINTED CMUETRETREXT ELECTRONIC ACCESS CONTROL LOCKSETINT ELECTRONIC ACCESS CONTROL LOCKSETELECTRIC STRIKE WITH PBEXIT DEVICECLOSERCLOSER WITH BACKSTOPKICK PLATES (SET OF TWO)WALL STOPFLOOR STOPOVERHEAD STOPHOOK STOPPUSH‐PULL (LATCH IF RATED)DEADBOLT WITH THUMBTURNFLUSH BOLTSASTRAGAL AND COORDINATORPASSAGE SETPRIVACY LOCKSET WITH INDICATORENTRY OR OFFICE LOCKSETCLASSROOM LOCKSETSTOREROOM LOCKSETSMOKE SEALSOUND SEALMAGNETIC HOLD‐OPENKEYED MULLIONSURF MTD VRD LESS BOTTOM RODPROVIDE RAINGUARD SWEEP ON DOOR BOTTOMMARK LOCATIONDESCRIPTIONFRM WID FIRE RATINGSIZENOTE TO BIDDERS / BUILDER: EXCEL SPREADSHEET AVAILABLE ON REQUESTFB‐11.753686EXTERIOR TO NEW CORRIDORFIBERGLASS/FULL LITES6111FB‐2PAIR1.753686 EXTERIOR TO NEW DINING FIBERGLASS/FULL LITES 6 2 2 2 1FB‐31.753686EXTERIOR TO NEW DINING FIBERGLASS/FULL LITES 6 1 1 1WD‐11.753686NEW CORRIDOR TO MECHANICAL SOLID CORE WOOD 7.75 1 1 1WD‐2PAIR1.75 36 86 MECHANICAL WOOD FULL LOUVER 7.75 2 2 1 1SLD‐1 1.75 96 104 DINING EXPANSION FLUSH WOOD SLIDING NA