STRUCTURAL EVALUATIONEng. Number OAA724657_C2_01
February 9 2018
Page 1 of 2
ATC Tower Services, Inc. 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office – 919-466-5414 Fax - www.americantower.com
Structural Evaluation
ATC Site Number & Name 97619, Lillington NC2, NC
Carrier Site Number & Name 169553 , Lillington
Site Location 2315 US 421 N
Lillington, NC 27546-8230, Harnett County
35.40722275 N / 78.85638428 W
Tower Description 400 ft Guyed Tower
Basic Wind Speed
Basic Wind Speed w/ Ice
Code
94 mph (3-Second Gust)
30 mph (3-Second Gust) w/ ¾” ice
ANSI/TIA-222-G / 2009 IBC / 2012 North Carolina Building Code
Existing and Reserved Equipment
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
398.0 398.0 3 - Empty Side Arm - --
348.0 348.0 2 Raycap RRFDC-3315-PF-48 Sector Frame (6) 1 5/8" Coax
(2) 1 5/8" Hybriflex Verizon 3 Antel BXA-70080-8CF-EDIN-2
299.0 299.0
1 RCU
Sector Frame
(12) 1 5/8" Coax
(2) 0.88" 8 AWG 6
(1) 0.28" Fiber
(1) 3/8" RET Control
Cable
AT&T Mobility
6 Andrew ETM190G-12UB
1 Raycap DC6-48-60-18-8F
3 Ericsson RRUS 11 (Band 12) (55 lb)
4 Kathrein 741 989
3 Ericsson RRUS 32 B2
2 Kathrein 742 213
1 Andrew SBNHH-1D45A
2 KMW EPBQ-652L8H8
286.0 286.0 3 - Empty Sector Frame - --
280.0 280.0 3 CCI DTMA-1819-DD-12 Sector Frame (12) 1 5/8" Coax T-Mobile 6 RFS APX16DWV-16DWVL-C
Equipment to be Removed
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
348.0 348.0
6 Antel WWX063X19G00
- (6) 1 5/8" Coax Verizon 3 Antel BXA-70063-8CF-EDIN-2
6 RFS FD9R6004/1C-3L
6 Ericsson RRUS-32
Eng. Number OAA724657_C2_01
February 9 2018
Page 2 of 2
ATC Tower Services, Inc. 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office – 919-466-5414 Fax - www.americantower.com
Proposed Equipment
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
348.0 348.0
6 Ericsson 8843 Rev 2
Sector Frame (6) 1 5/8" Hybriflex Verizon 6 Ericsson Radio 4449 - B13&B5
3 Raycap RCMDC-6627-PF-48
6 Commscope NHH-65C-R2B
1 Mount elevation is defined as height above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna
above grade level (AGL).
Install proposed coax in place of the removed Verizon Wireless coax.
The existing and proposed loads listed in the tables above are compared to the tower’s current design capacity
or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are
found different from those listed in the tables. The subject tower and foundation are adequate to support the
above stated loads in conformance with specified requirements.
TJG/ANG