Loading...
APPROVED FM PLANSHarneft Y � C O U N T# twwgency Swvi s Deperumat, hCE�1%t �J F:E.'F��� .h�rtait.or� Application for Plan ReviewaIi�/l/1�1y"�1 �<-. �t�l 1 G Application # J Date Received: ( Received By: Name of Project: Physical Address of Project: LuC4�Zn NC Z")'50 b Plans Submitted By: -,*aX z,5 0,& -41�y� �G ��1 L' WJL-� JAMS t ` K - Project Phone: (C4 CI )- ¢6'? - Jj**>O Contact Person/Address: WA ` w' C F&vL ) R-4- 44z s442 i;-fx9C. Contact Email: '13 tift..�•S ��25 u ShtK�N' Contact Phone: Contractor's Name/info: Contractor's Phone: ® Plans that are submitted will be reviewed as quickly as possible with an average time of review between 7-10 working days. Status checks may be conducted on plan reviews by visiting the website http://hteweb.harnett.org/Click2GovBP/index.isp or by calling the Harnett County Central Permitting Office (910-893-7525, Option #2), or the Harnett County Fire Marshal's Office (910-893-7580). Approved plans must be picked up from the Central Permitting Office and all fees paid before any required inspections can be conducted. Harnett C 0 U N T Y LmoVency Sefv es L?epartnwnt WWWJharrMttiCWIj Fire Marshal Division April 20, 2018 Bill Sears 1142 Executive Circle Cary, N.C. 27511 Re: Neill's Creek Baptist Church 4200 Neill's Creek Road Angier, N.C. 27501 Application Number 18-50043717 To whom it may concern, Thank you for submitting the plans for Neill's Creek Baptist Church. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 901.2 Construction Documents o Submit fire alarm plans to include battery calculations and specifications on appliances & devices. • 609.2 Where required o A type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. • 904.2.1 Commercial hood and duct systems o Each required commercial kitchen exhaust hood and duct system required by section 609 to have a type I hood shall be protected with an approved automatic fire -extinguishing system. Fire Extinguishers o Fire Extinguishers shall be 2A:20BC and shall be placed with a travel distance to not exceed 75' o Fire extinguishers are to be mounted no higher than 5' above the finished floor. o One type K fire extinguisher is required in the kitchen area. Harnett ,. �") ��l � � �� p- - ki a 1006.1 Illumination Required o The exit discharge shall be illuminated at all times the building spaces served by the means of egress is occupied o Illumination level in all areas of the means of egress shall not be less than I foot-candle at the walking surface and shall have emergency power supply. • Notes o A final fire inspection is required. Please contact this office direct to schedule fire inspection at 910-893-0743. o Plans indicate 1st grade children on second floor, section 427.3 NCBC 2012 edition, does not allow this. It has been referred to the building inspector. o NFPA 72 requires smoke detectors outside each elevator lobby and in elevator room, plans do not indicate this requirement. Elevator recall is also required to be connected to the fire alarm system. o Occupancy Capacity is not indicated for renovated Fellowship Hall. Thank you again for submitting the plans for Neill's Creek Baptist Church. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These rernarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office Again, thank you and we look forward to working with you during the construction period! Sincerely, Roger Sullivan Deputy Fire Marshal Harnett WWW.&m Plan Review, Inspection, and Permit Fees Application Number 18-50043717 $100.00 ❑ DRB Major Sub Division Prelim Site Plans $ - $200.00 ❑ Explosive Material (90 Days) $ - $100.00 ❑ Explosive Materials (72 Hours) $ - $100.00 ❑ Fireworks Public Display $ - $50.00 121 Final Inspection $ 50.00 $35.00 + $2.00 per device ❑ Fire Alarm Testing $ - $35.00 + $2.00 per nozzle ❑ Fixed Fire Suppression $ - $75.00 ❑ Insecticide Fog/Fumigation $ - $100.00 ❑ Pipe Test/UST/AGST $ - $50.00 0 Plans up to 5000 sq ft $ 50.00 $100.00 ❑ Plans 5001 sq ft to 10,000 sq ft $ - $150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft $ - $250.00 ❑ Plans 25,001 sq ft and over $ - $35.00 + 2.00 per head ❑ Sprinkler Certification Test $ - $50.00 ❑ Standpipe Testing $ - $50.00 ❑ Special Assembly (ie. amusement buildings, carnivals, fairs) $ - $75.00 Tents/Canopies/Air Supported Structure $100.00 Tank Installation (charge for each tank) $100.00 ❑ Tank Removal (charge for each tank) $ - Total Devices/Heads $ - Tota l Cost $ 100.00 Code Enforcement Official Roger Sullivan 4/20/2018