STAMPED_PDF_Verizon_Wireless_280360_Palmetto_Dr_Nc-_NC_OAA724543_C2_01_PE_LetterEng. Number OAA724543_C2_01
February 7 2018
Page 1 of 1
ATC Tower Services, Inc. - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office - 919.466.5414 Fax - www.americantower.com
Structural Evaluation
ATC Site Number & Name 280360, Palmetto Dr NC, NC
Carrier Site Number & Name 320262, MCLEOD_CREEK - ATC 280360
Site Location 101 Cypress Drive
SPRING LAKE, NC 28390-8117, Cumberland County
35.290750 N / 78.98645278 W
Tower Description 249 ft Monopole
Basic Wind Speed
Basic Wind Speed w/ Ice
Code
95 mph (3-Second Gust)
30 mph (3-Second Gust) w/ ¾” ice
ANSI/TIA-222-G / 2009 IBC / 2012 North Carolina Building Code
Existing and Reserved Equipment
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
245.0 250.0
6 Ericsson RRUS 11 (Band 12) (55 lb)
Sector Frame
(3) 2" conduit
(4) 0.78" 8 AWG 6
(2) 0.39" Fiber Trunk
AT&T Mobility
3 Ericsson RRUS 32 B2
3 Ericsson RRUS 12 w/ RRUS A2
3 CellMax CMA-B/6520/E0-8
3 KMW EPBQ-652L8H8
248.0 2 Raycap DC6-48-60-18-8F
232.0 232.0
2 Raycap RRFDC-3315-PF-48
T-Arm w/ Platform (2) 1.43"(36.4mm)
Hybrid Verizon 3 Andrew HBXX-6516DS-A2M
6 Andrew LNX-6515DS-VTM
Equipment to be Removed
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
232.0 232.0 3 Ericsson RRUS 12 w/ RRUS A2 - (6) 1 5/8” Coax Verizon 3 Ericsson RRUS B13 w/ RRUS A2
Proposed Equipment
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
232.0 232.0 6 Ericsson Radio 2212 B13/B5 T-Arm w/ Platform - Verizon 3 Ericsson RRUS-32
1 Mount elevation is defined as height above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna
above grade level (AGL).
The existing and proposed loads listed in the tables above are compared to the tower’s current design capacity
or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are
found different from those listed in the tables. The subject tower and foundation are adequate to support the
above stated loads in conformance with specified requirements.