CO itei ;A iiki A AA.A catIa.hiii AS ISSAS4
COUNTY OF HARNETT ,;
t. Building Inspections Department
Planning Services
op
Certificate of Compliance: Occupancy:
4 Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances.
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the A/'>.
North Carolina State Buildin cC deekl.For the following:
Use Classification. ,5 14l Permit Numbers
Name: Co S 71 nr (p ' (1(.H ( r�a�„ Building: /
O Electrical: �
4
Address: pg/it a/0 Insulation: I—
:1 ,,.,
en0. �
Mechanical: ��� 41
MFG Home:
F, Date: - 7 / ci/ Building Official: / 7, //
n
PREPARED ?./06/tL8, 14:11:10 INSPECTION TICKET PAGE 7
HArnett• County ' INSPECTOR: IVR DATE 3/07/18
ADDRESS . : 2811 NC 210 S SUBDIV: GEORGE R & ELSIE B SOUDERS
CONTRACTOR : CASTTON CONSTRUCTION CO LLC PHONE : (919) 697-6905
OWNER . . : JEC REAL ESTATE INVESTMTS LLC PHONE :
PARCEL . . : 10-0548- - -0001- -19-
APPL NUMBER: 17-50041337 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 05/09/2017 02:50 PM BPETRICH --
2811 NC 210 S
HWY 210 TOWARD BUNNLEVEL- LOT ON LEFT
NEAR INTERSECTION OF 210 AND AMERICAN
LEGION ROAD.
***LOCK BOX CODE IS 3201 ***
T/S: 08/21/2017 10:15 AM JBROCK ----
permise # 26239862
STRUCTURE: 000 000 46X62 3BDRM CRAWL W/GARAGE W/DECX
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS - 3.00 PROPOSED USE SFD
SEPTIC - EXISTING' - NEW WATER SUPPLY ' COUNTY
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
A814 01 7/13/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002996700
7/13/17 AP 2811 NC 210 S LILLINGTON 27546
T/S: 07/13/2017 09:44 AM SBENNETT
B101 01 7/13/17 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 002996734
7/13/17 AP T/S: 07/12/2017 02:30 PM JBROCK
NO T-POLE NEED TO CHANGE PERMIT CARD TO CRAWL SPACE NOT
MONO SLAB.
B103 01 7/18/17 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002998862
7/18/17 AP T/S: 07/17/2017 01:26 PM JBROCK
8105 01 8/17/17 JH R*OPEN FLOOR TIME: 17:00 VRU #: 003013075
8/17/17 AP T/S: 08/15/2017 02:58 PM JBROCK
would like am
R425 01 9/27/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003030681
9/27/17 DA T/S: 09/26/2017 01:11 PM JBROCK
1)Missing flashing for front porch.2)Install porch post per
plans.3)blocking on osb joints 4' from corners laid
down.4)Washer box min 34" from finished floor.5)Fire caulk
wire o top plate for kitchen pantry door.6)Missing air
barriers behind all tubs & showers in bathrooms & chase
between tub & shower.7)Fire caulk hole in top plate to left
of window in living room.8)Need correct truss documents for
inspection.9)Nail house wrap per installations instructions
& tap verticle joints.10)Support drain lines under house
every 4' .11)Replace cut floor joist under spare bath.
DO NOT SIDE OR INSULATE
I129 01 10/06/17 JH R*INSULATION INSPECTION TIME: 17:00 VRU #: 003034337
10/06/17 CA T/S: 10/04/2017 11:57 AM JBROCK
PER KYLE
R425 02 10/06/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003034345
10/06/17 DA T/S: 10/04/2017 11:57 AM JBROCK
ITEMS # 5 & 7
CONTINUED ONTO NEXT PAGE
PREPARED j(06/0, 14:11:10 INSPECTION TICKET PAGE 8
HArnett•County INSPECTOR: IVR DATE 3/07/18
ADDRESS . : 2811 NC 210 S SUBDIV: GEORGE R & ELSIE B SOUDERS
CONTRACTOR : CASTTON CONSTRUCTION CO LLC PHONE : (919) 697-6905
OWNER . . : SEC REAL ESTATE INVESTMTS LLC PHONE :
PARCEL . . : 10-0548- - -0001- -19-
APPL NUMBER: 17-50041337 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
1129 02 10/16/17 JH RtINSULATION INSPECTION TIME: 17:00 VRU #: 003039377
10/16/17 AP T/S: 10/13/2017 11:37 AM JHROCK
R425 03 10/16/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003039385
10/16/17 AP T/S: 10/13/2017 11:37 AM JBROCK
H824 01 12/01/17 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003061538
12/01/17 AP T/S: 12/04/2017 09:37 AM KHINSON
T/S: 12/04/2017 09:37 AM KHINSON
R429 01 2/08/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003086774
2/08/18 DA T/S: 02/07/2018 01:21 PM JBROCK
1) Insulate water lines for water heater in garage.2)Install
floor vents in house.3)Sewer cleanout to grade.4)4" from
;/ bottom of crawl door to grade.
R429 02 7�M T4.77;42. FOUR TRADE FINAL TIME: 17:00 VRU #: 003097896
T/S: 03/05/2018 03:40 PM JBROCK
COMMENTS AND NOTES