CO :, COUNTY OF HARNETT ktl
Building Inspections Department
Planning Servicesv .
Certificate of Compliance: Occupancy: ✓
4 Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances.
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the g
North Carolina State Building Codes For the following:
ii Use Classification:. S j rI��1 1 / Permit Numbers
Name:f 4 )n r1 l pn S! /4C t,'nn Building: /)
(°;) LC C. Electrical:
' Address: dc /)( ,2/U 5 Insulation: ri
" - Plumbing: %`
Mechanical: �
• -
4 MFG Home: Es
//////''''''
+ Date: 7 - 7- / g" Building Official: 7,1‘ i
001 i
71474 "1,1WITEl7
lWI ®I® l ®r lli
P�EPARED 3/06/18, 14:11:10 INSPECTION TICKET PAGE 5
Hajina^County INSPECTOR: IVR DATE 3/07/18
ADDRESS . : 2831 NC 210 S SUBDIV: GEORGE R & ELSIE B SOUDERS
CONTRACTOR : CASTTON CONSTRUCTION CO LLC PHONE : (919) 697-6905
OWNER . . : JEC REAL ESTATE INVESTMTS LLC PHONE :
PARCEL . . : 10-0548- - -0001- -20-
APPL NUMBER: 17-50041336 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 05/09/2017 02:45 PM HPETRICH --
2831 US 401 S
HWY 210 S TOWARD BUNNLEVEL - LOT ON
LEFT NEAR INTERSECTION OF 210 AND
AMERICAN LEGION ROAD
**** LOCK BOX CODE IS 3201 ****
T/S: 10/19/2017 01:12 PM JBROCK ----
premise # 00637921
STRUCTURE: 000 000 52X53 3BDRM CRAWL W/GARAGE W/DECK
FLOOD ZONE - FLOOD ZONE X
# BEDROOMS 3 .00 PROPOSED USE - SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY COUNTY
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
A814 01 7/13/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002996718
7/13/17 AP 2831 NC 210 S LILLINGTON 27546
T/S: 07/13/2017 09:47 AM SBENNETT
B101 01 7/13/17 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 002996726
7/13/17 DA T/S: 07/12/2017 02:29 PM JBROCK
1)Lug footings on garage walls need to be 12" deep per
plans.
B101 02 7/14/17 JLP R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 002997039
7/14/17 AP T/S: 07/13/2017 09:57 AM JBROCK
T/S: 07/14/2017 03:28 PM JPERRY
8103 01 7/25/17 KS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003002680
7/25/17 AP T/S: 07/24/2017 01:57 PM JBROCK
T/S: 07/25/2017 02:40 PM KSLATTUM
8105 01 8/11/17 JH R*OPEN FLOOR TIME: 17:00 VRU #: 003011053
8/11/17 AP T/S: 08/10/2017 02:01 PM JBROCK
would like an am inspection
R425 01 10/16/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003039369
10/16/17 DA T/S: 10/13/2017 11:37 AM JBROCK
1)Strap each end of garage door from top plate to 1' below
header.2)Strap all 4 stud columns throughout
house.3)Missing nails in hurricane straps for 2ply trusses
in garage.4)Nail all 2 ply trusses per truss
documents.5)Fire caulk hole over electrical panel in garage
& hole in left back corner of kitchen.6)Need 8-16 penny
nails in structual nail guard over panel in garage.7)100
psi on water line test.8)Missing bracing on A4 & B1GE
truss.9)@ply truss on garage wall needs 2 studs under on
garage wall & hurricane straps.
R425 02 10/20/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003041944
10/20/17 DP T/S: 10/19/2017 01:12 PM JBROCK
ITEMS # 3 & 5 NOT CORRECTED
R425 03 10/26/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003044328
CONTINUED ONTO NEXT PAGE
PyEPARED 3/06/18, 14 :11:10 INSPECTION TICKET PAGE 6
HapietYt;County INSPECTOR: IVR DATE 3/07/18
ADDRESS . : 2831 NC 210 S SUBDIV: GEORGE R & ELSIE B SOUDERS
CONTRACTOR : CASTTON CONSTRUCTION CO LLC PHONE : (919) 697-6905
OWNER . . : SEC REAL ESTATE INVESTMTS LLC PHONE :
PARCEL . . 10-0548- - -0001- -20-
APPL NUMBER: 17-50041336 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
10/26/17 AP T/S: 10/25/2017 10:28 AM JBROCK
I129 01 10/30/17 JR R*INSULATION INSPECTION TIME: 17:00 VRU #: 003046356
10/30/17 AP T/S: 10/27/2017 02:10 PM JBROCK
H824 01 12/01/17 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003061520
12/01/17 AP T/S: 12/04/2017 09:35 AM KHINSON
T/S: 12/04/2017 09:35 AM KHINSON
R429 01 2/08/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003086782
2/08/18 DA T/S: 02/07/2018 01:21 PM JBROCK �/
)Missing toilet lid in spare bathroom, Weatherstrip on
attic doormohInsulate water lines for water heater in
garage.4)Missing toe boards on steps in garage.Shnstall
floor vents in house B')4" from bottom of crawl door to
grade.S9)) Sewer cleanout to grade.8)Protection on water
heater in garage.
ISSUED TEMP POWER
R429 02 3/07/18 T FOUR TRADE FINAL TIME: 17:00 VRU #: 003097904
T/S: 03/05/2018 03:40 PM JBROCK
COMMENTS AND NOTES