FM REVIEW ®Harnett wrobs.COU NTT aawy� Unite p.p.oraa
1++1y�f
NORTMI CAROLINA �wy ws.6rMnarq
Application
for /Plan �R2evie�wJ(
�j A�p�plication# � ls - S�—�`�'„-'W ; `f'
Date Received: l Ott / g ReceivedceiBy:
Name of Project: / 0 (✓ ✓. 0T C64 S
Physical Address of Project: ( � q Ar m c r 51
dire 0a45 , NC 27 sr al
Plans Submitted By: ) tiCE v,$'f i u I.,v t v`
Project Phone: ( 9! 1 )-710-p Z re C
Contact Person/Address: 2 t7 Ni Po t_
B o 5av l (--)
5 ,„ r \ c/ (t.1 >° 275-77
Contact Email: 76) -'yq. b V'C�K�jt �/ (1 Vy 1'. Cf
Contact Phone: ( q/ 1 )-10,/ - p
7. ( )- -
Contractor's Namellnfo: 1 C) 6 h CD `. S T c Li c 4 ° ", I h
Pe Vo2(
,.1/4,_: \' Ic ( kJ � C 27x' 77
q
Contractor's Phone: ( 1f` / )- 63 /- 2 U:Sr"
• Plans that are submitted will be reviewed as quickly as possible with an average time of review
between 7-10 working days.
• Status checks may be conducted on plan reviews by visiting the website
http://hteweb.hamett.org/Click2GovBP/Index.isp or by calling the Harnett County Central Permitting
Office(910-893-7525,Option#2), or the Harnett County Fire Marshal's Office(910-893-7580).
• Approved plans must be picked up from the Central Permitting Office and all fees paid before any
required inspections can be conducted.
IICHarnett
COUNTY * A o� .....9....,sw..waw.eM<
Ir' ��l1YMILpp
Plan Review, Inspection, and Permite Fees
Application Number 18-50043676
$100.00 ❑ DRB Major Sub Division Prelim Site Plans $ -
$200.00 El Explosive Material (90 Days) $ -
$100.00 ❑ Explosive Materials (72 Hours) $ -
$100.00 ❑ Fireworks Public Display $ -
$50.00 lY Final Inspection $ So•"'
$35.00 +$2.00 per device ❑ Fire Alarm Testing $ -
$35.00 +$z.00 per nozzle ❑ Fixed Fire Suppression $ -
$75.00 ❑ Insecticide Fog/Fumigation $ -
$100.00 ❑ Pipe Test/UST/AGST $ -
$50.00 O Plans up to 5000 sq ft $ 50.00
$100.00 El Plans 5001 sq ft to 10,000 sq ft $ -
$150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft $ -
$250.00 ❑ Plans 25,001 sq ft and over $ -
$35.00 +2.00 per head ❑ Sprinkler Certification Test $ -
$50.00 ❑ Standpipe Testing $ -
$50.00
❑ Special Assembly
(ie.amusement buildings,carnivals,fairs) $ -
El
$75.00 Tents/Canopies/Air Supported Structure
$ -
$100.00 Tank Installation (charge for each tank)
$100.00 ❑ Tank Removal (charge for each tank) $ -
Total Devices/Heads $ -
Total Cost $ tr OO
Code Enforcement Official Roger Sullivan 4/9/2018
Harnett
Thrt COUNTY * A e , fm.ro.ea Swam Department
'r' wwathenian.wq
Fire Marshal Division
April 09, 2018
Talon Construction
P.O. Box 148
Smithfield, NC 27577
Re: Town of Coats
186—234 Lemon Street
Coats,NC 27521
Application Number 18-50043676
To whom it may concern,
Thank you for submitting the plans for the Town of Coats. The plans have been carefully
reviewed by a qualified code enforcement official to examine for full compliance with
the North Carolina Fire Prevention Code and all other fire protection regulatory
documents. There are some items that were found during the plan review process that
need to be addressed before a final inspection of the new facility can be given. These
items are outlined and described below.
• 505.1 Physical Address
o The physical address of the building shall be posted in a conspicuous
place so that it can be seen on approach from the road, access road, and/or
parking lot.
o The numbers used to make up the physical address shall be at least 6
inches in height.
• 506.1 Knox Box
o A secure key box shall be installed on the new building that houses all
keys to all the doors within the building in which the fire department
would need access to in the event of an emergency.
o Knox Box ID stickers shall be placed on all exterior doors in which entry
to the building may be gained.
o The box shall be mounted not to exceed 48—60 inches in height.
o The basic model for the buildings should be at least a selection from the
3200 Series listed on the order form.
• https://www.knoxbox.com/store/departmentSearch.cfin
• Fire Extinguishers
.r L
MCOUNTY
Harnett
om
) Em.y.Hrs«. . Dna w *
wNwbrnnt.ary
v
o Fire Extinguishers shall be 2A:20BC and shall be placed with a travel
distance to not exceed 75'
o Fire extinguishers are to be mounted no higher than 5' above the finished
floor.
• 1006.1 Illumination Required
o The exit discharge shall be illuminated at all times the building
spaces served by the means of egress is occupied
o Illumination level in all areas of the means of egress shall not be
less than 1 foot-candle at the walking surface and shall have
emergency power supply.
• Notes
o A final fire inspection is required. Please contact this office direct to
schedule fire inspection at 910-893-0743.
Thank you again for submitting the plans for Town of Coats. Please review the plans and
adhere to any notes and alterations that were made in addition to the original drawings.
These remarks are for the plans that were submitted and its original intent. These remarks
do not apply if the original intent changes or what was submitted on the above date
changes. If you have any questions, please do not hesitate to call this office
Again, thank you and we look forward to working with you during the construction
period!
Sincerely,
Roger Sullivan
Deputy Fire Marshal