L-Series Datasheets_Complete (1)Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383, 3057072 Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1,2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 1.91˝ D (143 mm L × 119 mm W × 49 mm D) Compact Wall-Mount Dimensions (including lens)5.26” L x 3.46” W x 1.91” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.25˝ D (143 mm L × 119 mm W × 32 mm D) Compact Horn Dimensions 5.25” L x 3.45” W x 1.25” D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9*Coded High 85 90 90 10*3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Candela Range (15–115 cd) DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Current Draw Data Horn Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86503 • 03/17 L-Series Dimensions Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT L-Series Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover) All -SP models have “FUEGO” marking on cover All -ALERT models have “ALERT” marking on cover Compact Strobe / Horn Strobe Strobe / Horn Strobe Compact Horn Horn Model Description Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Agency Listings 7320-1653:0505S4048FM approved except for ALERT models 3057493 Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Wall Applications System Sensor L-Series selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features • Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation • No extension ring required • Field selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, 185 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) • Seakers offer high fidelity and high volume sound output • Compatible with System Sensor synchronization protocol • Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products • Tamper-resistant construction • Updated modern aesthetics The System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for wall speaker strobes. The low total harmonic distortion of the speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. System Sensor L-Series makes installation easy • Attach a universal mounting plate to a 4 × 4 × 21⁄8 inch back box. Flush-mount applications do not require an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General L-Series speaker and speaker strobes shall mount to a 4 × 4 × 21⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Wall- mount speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, 185. Speaker The speaker shall be a System Sensor L-Series model _______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model __________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Wall-Mount Length Width Depth SPL Speaker 6.5 in, 165 mm 5 in, 127 mm .97 in,23 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 3.2 in, 82 mm SPSL Speaker/Strobe (including lens and speaker) 6.5 in, 165 mm 5.0 in, 127 mm 2.3 in, 58 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 4.5 in, 116 mm Electrical/Operating Specifications Nominal Voltage (speakers)25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC or regulated 24 DC/FWR1,2 Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33V (24 V nominal) Frequency Range 400 to 4000 Hz Power ¼, ½, 1, 2 watts 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 and 30 cd UL Current Draw Data UL Max Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC DC FWR 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Sound Output Speaker Strobe ¼ W ½ W 1 W 2 W UL Reverberant (dBA @10 ft)77 80 83 86 UL Anechoic (dBA @10 ft)77 80 83 86 Sound Output Speaker ¼ W ½ W 1 W 2 W UL Reverberant (dBA @10 ft)79 82 85 88 UL Anechoic (dBA @10 ft)79 82 85 88 L-Series Dimensions Wall-Mount Speaker Wall-Mount Speaker Strobe 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86701 • 03/17 L-Series Ordering Information Wall Mount White Red Description SPWL SPRL Speaker only SPSWL SPSRL Speaker Strobe SPSWL-P SPSRL-P Plain Speaker Strobe SPSWL-ALERT —Speaker Strobe, Amber Lens SPSWL-CLR-ALERT —Speaker Strobe Clear Lens —SPSRL-SP Speaker Strobe, Fuego Accessories White Red Description RFPW RFP 7 in × 9.5 in Retrofit Plate SBBSPWL SBBSPRL Surface Mount Back Box for Speakers and Speaker Strobes TR-2W TR-2 Wall Mount Trim Ring Notes: All -P models have a plain housing (no “FIRE” marking on the cover) Surface Mounting Wall-Mount Speaker Strobe with SBBSPL Surface Mount Back Box Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383 AVDS86800 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11⁄16 × 4 11⁄16 × 2 1⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3)8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens)6.8" diameter × 2.5" high (173 mm diameter × 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 UL Current Draw Data Horn Strobe Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86801 • 03/17 L-Series Dimensions Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White L-Series Ordering Information Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications System Sensor L-Series selectable-output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features • Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation • No extension ring required • Field selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (¼, ½, 1 and 2 watts) • Speakers offer high fidelity and high volume sound output • 520 Hz capable with compatible FACP • Compatible with System Sensor synchronization protocol • Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products • Tamper-resistant construction • Updated modern aesthetics System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field-selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. L-Series makes installation easy • Attach a universal mounting plate to a 4 × 4 × 21⁄8 inch back box . Flush-mount applications do not require an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw.Agency Listings 7320-1653:0505S4048FM approved except for ALERT models 3057493 L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General L-Series speaker and speaker strobes shall mount to a 4 × 4 × 21⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, 177. Speaker The speaker shall be a System Sensor L-Series model _______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model __________ listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount Back Box 6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Back Box 6.9 in, 176 mm 5.37 in, 136 mm Electrical/Operating Specifications Nominal Voltage (speakers)25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers)50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes)Regulated 12 VDC or regulated 24 VDC/FWR 1,2 Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz3 Power ¼, ½, 1, 2 watts 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 and 30 cd. 3. 520Hz capable with compatible FACP. UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) Candela 8 to 17.5 Volts 16 to 33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Ceiling-Mount Speaker Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Ceiling-Mount Speaker Strobe Sound Output Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 L-Series Dimensions Ceiling Speaker Ceiling Speaker Strobe 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86601 • 03/17 L-Series Ordering Information Ceiling Mount White Red Description SPCWL SPCRL Speaker only SPSCWL SPSCRL Speaker Strobe SPSCWL-P —Plain, Speaker Strobe SPSCWL-SP —Fuego, Speaker Strobe SPSCWL-CLR-ALERT —Alert, Speaker Strobe, Clear Lens Accessories White Red Description SBBCWL SBBCRL Universal Ceiling Surface Mount Back Box TRC-2W TRC-2 Universal Ceiling Trim Ring Surface Mounting Ceiling Speaker with Surface Mount Back Box Ceiling Speaker Strobe with Surface Mount Back Box Agency Listings 7135-1653:0503 S4011 3057383, 3057072 Features • Updated modern aesthetics • Plug-in design with minimal intrusion into the back box • Mounting plate shorting spring feature checks wiring continuity before device installation • Captive mounting screw • Tamper-resistant construction • Field-selectable candela settings: – Wall: 15, 30, 75, 95, 110, 135, 185 – Ceiling: 15, 30, 75, 95, 115, 150, 177 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch for tone and volume selections • Five selectable tones with high and low volume settings • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Wall models listed for wall mounting only, ceiling models listed for ceiling mounting only The System Sensor L-Series product line of wall and ceiling- mount chimes and chime strobes include a variety of features that increase their application versatility while simplifying the installation. With white and red plastic housings, System Sensor L-Series can meet virtually any application requirement. Selectable-output chimes and chime/strobes are private mode notification appliances used to alert trained personnel to investigate possible emergency situations and to take appropriate action. Security guard and nurse workstations are ideal locations for chime products. All devices feature plug-in design with minimal intrusion into the back box, making the installation fast and foolproof while virtually eliminating costly and time-consuming ground faults. Installers can easily adapt devices to a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or-24 volt operation, and a rotary switch for chime tones and two volume selections. Selectable Output Chimes and Chime/ Strobes System Sensor L-Series selectable-output chimes and chime/strobes are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. L-Series Specifications Architect/Engineer Specifications General System Sensor L-Series chimes and chime strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, single- gang 2 × 4 × 17/8-inch back box, or double-gang back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, System Sensor L-Series products, when used with the Sync•Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Chime strobes shall have field-selectable candela settings of 15, 30, 75, 95, 110 , 135, and 185 for wall units and 15, 30, 75, 95, 115, 150, and 177 for ceiling units. Chime Strobe Combination The chime strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1638 and UL 464. The chime strobe shall comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The chime shall have two audibility options and an option to switch between temporal three pattern, non-temporal(continuous) pattern, 1 second chime pattern, 1/4 second chime pattern, 5 second whoop chime pattern. These options are set by a multiple position switch. Synchronization Module The module shall be a System Sensor Sync•Circuit _______ listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and all available chime tones. Also, while operating the strobes, the module shall silence the chimes on chime/strobe models over a single pair of wires. The module shall mount to a 4 11/16 × 4 11/16 × 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12VDC or regulated 24DC/FWR1 Operating Voltage Range2 8 to 17.5V (12V nominal) or 16 to 33V (24V nominal) Operating Voltage Range with MLD3 8.5 to 17.5V (12V nominal) or 16.5 to 33V (24V nominal) Input terminal wire gauge 12 to 18 AWG Chime strobe dimensions (including lens)5.6 in L × 4.7 in W × 1.91 in D (143 mm L × 119 mm W × 49 mm D) Chime dimensions 5.6 in L × 4.7 in W × 1.25 in D (143 mm L × 119 mm W × 32 mm D) Ceiling Chime strobe dimensions (including lens)6.8” Dia. x 2.47” D (173.5mm Dia. x 62.7mm D) SBBRL (red wall surface mount back box)5.6 in L × 4.7 in W × 4.3 in D (142 mm L × 119 mm W × 109 mm D) SBBWL (white wall surface mount back box)5.6 in L × 4.7 in W × 4.3 in D (142 mm L × 119 mm W × 109 mm D) SBBCRL (red ceiling surface mount back box)6.9” Dia. x 2.5” D (175.8mm Dia. x 63.5mm) SBBCWL (white ceiling surface mount back box)6.9” Dia. x 2.5” D (175.8mm Dia. x 63.5mm) Notes: 1. Full Wave Rectified (FWR) voltage is a non-filtered, time varying power source that is used on some power supply and panel outputs. 2. CHS products will operate at 12 V nominal only for 15 and 30 cd. UL Max. Chime Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Second Chime High 5 8 9 1 Second Chime Low 5 8 9 1/4 Second Chime High 6 10 10 1/4 Second Chime Low 5 9 9 Temporal Chime High 7 10 10 Temporal Chime Low 6 9 9 5 Second Whoop High 12 15 16 5 Second Whoop Low 7 10 11 Coded High 12 15 16 * UL Current Draw Data *This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. Chime Patterns Setting Repetition Rate dB Level 1 1 Second Chime High 2 1 Second Chime Low 3 1/4 Second Chime High 4 1/4 Second Chime Low 5 Temporal Chime High 6 Temporal Chime Low 7 5 Second Whoop High 8 5 Second Whoop Low 9 Coded**High **For chime only. Chime and Chime/Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 1 Second Chime High 61 62 62 2 1 Second Chime Low 56 55 55 3 1/4 Second Chime High 67 70 70 4 1/4 Second Chime Low 61 61 61 5 Temporal Chime High 64 66 66 6 Temporal Chime Low 59 60 60 7 5 Second Whoop High 76 78 78 8 5 Second Whoop Low 62 64 64 9 Coded**High 57 51 57 Tone Selection Chime tone selection is accomplished by using the rotary switch on the back of the product. The current draw and sound measurements for various chime tone settings are listed below. UL Max. Chime/Strobe Current Draw (mA RMS) Wall DC Input 8–17.5 Volts 16–33 Volts 15 30 15 30 75 95 110 135 185 1 Second Chime 90 154 51 71 115 136 161 202 238 1 Second Chime 89 154 50 70 116 136 154 199 242 1/4 Second Chime 90 154 52 72 117 137 168 201 242 1/4 Second Chime 89 153 49 70 115 136 165 199 241 Temporal Chime 88 153 49 69 112 137 168 201 246 Temporal Chime 88 152 47 68 111 136 167 196 241 5 Second Whoop 91 154 52 70 113 132 176 206 243 5 Second Whoop 87 149 46 66 108 130 170 202 240 FWR Input 16–33 Volts 15 30 75 95 110 135 185 1 Second Chime 70 90 160 176 197 233 275 1 Second Chime 67 88 158 175 191 232 271 1/4 Second Chime 69 93 159 175 198 233 272 1/4 Second Chime 68 93 154 169 196 232 270 Temporal Chime 65 90 145 170 189 228 283 Temporal Chime 64 89 142 170 188 219 282 5 Second Whoop 70 93 145 168 187 223 278 5 Second Whoop 62 84 137 159 180 216 272 UL Max. Chime/Strobe Current Draw (mA RMS) Ceiling DC Input 8–17.5 Volts 16–33 Volts 15 30 15 30 75 95 115 150 177 1 Second Chime 95.5 165 47 69 117 137 165 202 238 1 Second Chime 93 162 47 68 116 137 165 200 238 1/4 Second Chime 94 161 48 70 117 138 166 202 237 1/4 Second Chime 93 157 48 69 116 137 164 199 236 Temporal Chime 93 163 48 69.5 116 138 165 199 238 Temporal Chime 92 160 47 68.5 116 136 164 198 237 5 Second Whoop 98 169 54 77 124 146 173 206 245 5 Second Whoop 95 166 49 71 117 144 168 202 239 FWR Input 16–33 Volts 15 30 75 95 115 150 177 1 Second Chime 63 90 147 169 184 212 245 1 Second Chime 63 88 147 169 183 212 244 1/4 Second Chime 65 90 149 170 184 213 246 1/4 Second Chime 64 89 148 168 184 213 244 Temporal Chime 64 89 148 169 184 212 245 Temporal Chime 63 88 147 169 183 212 245 5 Second Whoop 75 100 155 178 193 221 255 5 Second Whoop 68 91 148 170 186 217 248 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86901 • 03/17 L-Series Dimensions Model Description CHRL Chime, Wall, Red CHWL Chime, Wall, White CHSRL Chime Strobe, Wall, Red CHSWL Chime Strobe, Wall, White CHSCRL Chime Strobe, Ceiling, Red CHSCWL Chime Strobe, Ceiling, White Accessories SBBRL Surface Mount Back Box, Wall, Red SBBWL Surface Mount Back Box, Wall, White SBBCRL Surface Mount Back Box, Ceiling, Red SBBCWL Surface Mount Back Box, Ceiling, White L-Series Ordering Information Wall Chime Ceiling Mount Chime/Strobe with Ceiling Surface Mount Back Box Wall Chime/Strobe Ceiling Surface Mount Back Box Wall Surface Mount Back Box Wall Mount Chime/Strobe with Wall Surface Mount Back Box Ceiling Chime/Strobe Field-Selectable Emergency Communications Devices System Sensor L-Series emergency communications devices and accessories combine application versatility with all the time- and money-saving benefits of the L-Series line. Emergency Communications Features: • Plain or ALERT-printed white housings • Clear or Amber lens strobes and speaker strobes • Color lens attachments for use with clear lens wall or ceiling strobes • Meets DoD specification requirements L-Series Features: • Plug-in design for simplified installation and troubleshooting • Mounting plate shorting spring easily tests wiring continuity • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings of: – Wall: 15, 30, 75, 95, 110, 135, 185 – Ceiling: 15, 30, 75, 95, 115, 150, 177 • Rated from 32°F to 120°F (indoor devices) • Optional tamper-resistant Torx head screw • Compatible with System Sensor synchronization protocol System Sensor L-Series, the broadest and most versatile line of notification devices available, includes a wide range of devices to meet emergency communications application requirements. ALERT-printed on white housings amber lens strobes and speaker strobes provide visual signaling for emergency communications in compliance with ANSI/ UL 1638 — Standard for General Signaling Visible Appliances. Other Plain or ALERT-printed models provide clear lenses for use with color lens strobe attachments (amber, blue, green, and red) that easily attach to strobe and speaker strobe devices without a candela derating. In addition, L-Series emergency communications devices include plain (non-printed) strobes, horn strobes, and speaker strobes. These devices, along with ALERT-printed devices and L-Series accessories, can meet a wide range of requirements for indoor applications, including emergency communications, general signaling, severe weather, and emergency response. All L-Series emergency communications and general signaling devices are compatible with the entire L-Series line and include all the same time- and money-saving innovations. For example, plug in design simplifies installation and reduces costly ground faults, universal mounting plates with onboard shorting springs test wiring continuity to speed installation and protect devices from damage, and field-selectable settings provide versatility and enable installers to quickly set each device to meet application requirements. Agency Listings Strobes: 7125-1653:0504 Horns/Horn Strobes: 7135-1653:0503 Speaker Strobes: 7320-1653:0505 FM approved except for ALERT models and colored lenses. Horn Strobes: 3057383, 3057072 Speaker Strobes: 3057493 Horn strobes: S5512, S4011 Speaker Strobes: S4048 Speaker Sound Ouput UL Reverberant (dBA @ 10 ft.)2 W 1 W 1/2 W 1/4 W Wall-Mount SPS Series 88 85 82 79 Ceiling-Mount SPC Series 88 85 82 79 L-Series Specifications Architectural/Engineering Specifications General System Sensor L-Series strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact devices shall mount to a single-gang 2 × 4 × 17⁄8-inch back box. L-Series speaker strobes shall mount to a 4 x 4 x 21/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes, horn strobes, and speaker strobes shall have field-selectable candela settings, including 15, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The clear strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. Colored lens strobes shall be listed to ANSI/UL 1638 and shall be approved for Private Mode Emergency. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. The horn and horn strobe models shall operate on a coded or non-coded power supply. Speaker Strobe Combination The speaker strobe shall be a System Sensor L-Series Model __________ listed to UL 1480 and UL 1971 and be approved for fire protective signaling systems. Speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. Speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Color Lens Strobe Attachment The System Sensor L-Series color lens attachments shall be approved for fire protective service as listed in UL 1638. The lens attachments shall only be used with (plain non-fire-printed) System Sensor strobe devices. They shall mount to any wall or ceiling strobe and be rated from minus 35 degrees to 151 degrees Fahrenheit. The effective light loss for wall units shall be as follows Amber = 0%, Blue = -40%, Green = -65%, Red = -85% Physical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions Wall-Mount Strobe and Horn Strobe (including lens) 5.6˝ L x 4.7˝ W x 1.91˝ D (143 mm L × 119 mm W × 49 mm D) SPS Speaker Strobe (including lens)6.5” L x 5.0” W x 2.3” D (165 mm L x 127 mm W x 58 mm D) Dimensions Ceiling-Mount Strobe (including lens)6.8˝ diameter x 2.8˝ D Electrical/Operating Specifications Nominal Voltage (strobes and horn strobes)Regulated 12 VDC or regulated 24 DC/FWR Nominal Voltage (speakers)25 V or 70.7 V (nominal) Maximum Supervisory Voltage (speakers)50 VDC Operating Voltage Range 8 to 17.5 V (12 V nominal) or 17 to 33 V (24 V nominal) Operating Voltage Range with MDL3 8.5 to 17.5 (12V nominal) or 16.5 to 33V (24V nominal) Strobe Flash Rate 1 flash per second Speaker Frequency Range 400 to 4,000 Hz Speaker Power ¼, ½, 1, 2 watts AVDS87102 UL Current Draw Data UL Max Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 110 N/A 148 179 115 N/A 158 191 135 N/A 172 209 150 N/A 189 228 177 N/A 226 264 185 N/A 222 257 Wall Candela Settings: 15, 30, 75, 95, 110, 135, 185 Ceiling Candela Settings: 15, 30, 75, 95, 115, 150, 177 UL Max. Current Draw (mA RMA), 2-Wire Horn Strobe DC Input 8VDC 16VDC 15 30 15 30 75 95 110 115 135 150 175 185 Temporal High 98 158 54 74 121 142 162 187 196 217 254 245 Temporal Low 93 154 44 65 111 133 157 185 184 211 249 235 Non-Temporal High 106 166 73 94 139 160 182 187 211 230 273 262 Non-Temportal Low 93 156 51 71 119 139 162 170 190 216 258 239 3.1K Temporal High 93 156 53 73 119 140 164 184 190 229 257 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 185 212 252 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 202 208 229 271 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 187 192 217 259 242 FWR Input 16VFWR 15 30 75 95 110 115 135 150 175 185 Temporal High 83 107 156 177 198 223 234 254 286 287 Temporal Low 68 91 145 165 185 199 223 229 262 271 Non-Temporal High 108 135 181 207 230 223 264 254 286 315 Non-Temportal Low 79 104 157 175 197 199 235 229 262 281 3.1K Temporal High 81 105 155 177 196 225 234 255 289 284 3.1K Temporal Low 68 90 145 166 186 196 222 229 260 276 3.1K Non-Temporal High 101 131 176 204 230 225 264 255 289 326 3.1K Non-Temporal Low 77 102 156 177 199 196 234 229 260 291 Wall Candela Settings: 15, 30, 75, 95, 110, 135, 185 Ceiling Candela Settings: 15, 30, 75, 95, 115, 150, 177 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9*Coded High 85 90 90 10*3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. Horn Tones and Sound Output Data AVDS87102 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor.Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.AVDS87102 • 03/17 Part No.Description Colored Lenses LENS-A2 Wall-Mount Lens Attachment, Amber LENS-B2 Wall-Mount Lens Attachment, Blue LENS-G2 Wall-Mount Lens Attachment, Green LENS-R2 Wall-Mount Lens Attachment, Red LENS-AC2 Ceiling-Mount Lens Attachment, Amber LENS-BC2 Ceiling-Mount Lens Attachment, Blue LENS-GC2 Ceiling-Mount Lens Attachment, Green LENS-RC2 Ceiling-Mount Lens Attachment, Red Bezel Kits* BZR Wall Red Bezel Kit BZW Wall White Bezel Kit BZGR Compact Wall Red Bezel Kit BZGW Compact Wall White Bezel Kit BZRC Horn/Strobe Ceiling Red Bezel Kit BZWC Horn/Strobe Ceiling White Bezel Kit BZSPR Speaker Wall Red Bezel Kit BZSPW Speaker Wall White Bezel Kit BZSPRC Speaker Ceiling Red Bezel Kit BZSPWC Speaker Ceiling White Bezel Kit *Each bezel pack ships in a package of 5. For bezel option add -F (FIRE), -AL (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -SP (FUEGO), -PG (FOGO) for desired printing. L-Series Ordering Information Part No.Description Alert Devices SWL-CLR-ALERT Strobe, White, Wall, Clear Lens, Alert SWL-ALERT Strobe, White, Wall, Amber Lens, Alert SCWL-CLR-ALERT Strobe, White, Ceiling, Clear Lens, Alert SPSWL-ALERT Speaker Strobe, White, Wall, Amber Lens, Alert SPSWL-CLR-ALERT Speaker Strobe, White, Wall, Clear Lens, Alert SPSCWL-CLR-ALERT Speaker Strobe, White, Ceiling, Clear Lens, Alert Plain Wall Strobes SRL-P Strobe, Red, Wall, Plain SWL-P Strobe, White, Wall, Plain Plain Wall Horn Strobes P2RL-P Horn Strobe, Red, Wall, Plain P2WL-P Horn Strobe, White, Wall, Plain Plain Wall Speaker Strobes SPSRL-P Speaker Strobe, Red, Wall, Plain SPSWL-P Speaker Strobe, White, Wall, Plain Plain Ceiling Speaker Strobes SPSCWL-P Speaker Strobe, White, Ceiling, Plain Notes: All -P models have a plain housing (no “FIRE” marking on cover). Audible Visible Accessories System Sensor L-Series offers a wide range of Audible Visible (AV) accessories to enable you to meet a variety of application requirements. Features MP120KL Mounting Plate • Designed for both indoor and outdoor use • Plug-in design eliminates ground faults • Power supply that converts 120 VAC to nominal 24 V FWR • Compatible with all two-wire L-Series devices Color Lens Attachments • Easily turns any device into a strobe for ECS/MNS events: severe weather, toxic gases, sprinkler activation and more • Outdoor rated from −35°F to 151°F • Wall- or ceiling-mount lenses available • UL 1638 listed Bezel Kits • Easily turn a Fire or Plain device into a device to meet ECS/MNS requirements • Bezel kits available for strobes, horns, chimes, horn strobes, chime strobes and speaker strobes • Bezels options with FIRE, ALERT, EVAC, AGENT, PLAIN, FUEGO, FOGO printing • For use with L-Series devices only • Operating temperature -40°F to 151°F The MP120KL Mounting Plate is designed to use 120 VAC to power SpectrAlert Advance horns, strobes, horn strobes, chimes, and chime strobes. Color Lens Attachments install easily on any L-Series strobe devices to provide distinctive visual signaling. Bezel Kits enable installers to easily turn any L-Series Fire or Plain device into a device that meets ECN/MNS requirements. Bezel kits are available for all varieties and footprints of L-Series products and come in FIRE, ALERT, EVAC, AGENT, FUEGO, FOGO, and Plain options making customization easy. Universal Trim Rings for wall and ceiling mount devices allow for additional space within the backbox. L-Series Surface Mount Back Boxes are the best solution in locations where you have a hard surface to mount to. The Sync•Circuit Module synchronizes L-Series strobes at 1 Hz and horns and chimes at temporal 3 over a single pair of wires. Patented module technology also allows the silencing of horns or chimes on horn strobe and chime strobe models over a pair of wires. See the Sync•Circuit Datasheet for more information. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 S4048 FM approved : Sync modules and MP120KL. 3057383, 3057072, 3057493 Does not include color lenses. Specifications MP120KL 120 VAC mounting plate model MP120KL shall be listed to UL 464 for fire protective signaling systems. The mounting plate shall power a two- wire L-Series horn, strobe, horn strobe, chime or chime strobe from a 120 VAC supply converted to nominal 24 V FWR. For indoor applications, the mounting plate shall be installed in a 4x4x21/8 -inch junction box. Compatibility MP120KL may be used with any of the following products at all horn and strobe settings: P2RL, P2WL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, PC2RL, PC2WL, SRL, SWL, SRL-P, SWL-P, SRL-SP, SWL-CLR-ALERT, SWL-ALERT, SCRL, SCWL, SCWL-CLR-ALERT, HRL, HWL, CHRL, CHWL, CHSRL, CHSWL, CHSCRL, CHSCWL. Physical/Operating Specifications Standard Operating Temperature –40°F to 151°F (–40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Nominal Voltage Regulated 120 VAC Operating Voltage Range 96–132 VAC Current Draw From AC Line 150 mA max. L-Series Bezels The System Sensor L-Series bezels are for installation with strobes, horns, chimes, horn strobes, chime strobes, and speaker strobes. Bezels are offered in red and white for both wall and ceiling devices. Available in FIRE, ALERT, EVAC, AGENT, Plain (no marking), FUEGO, and FOGO. Operating temperature shall be -40°F to 151°F. Specifications Colored Lens Attachments The System Sensor L-Series colored lens attachments shall be approved for fire protective service as listed in UL 1638. The lens attachments shall only be used with plain (no “FIRE” print) System Sensor strobe devices or in conjunction with a non-fire printed bezel. The lens shall mount to any wall- or ceiling-mount strobes and shall be rated from −35°F to 151°F. Compatibility Colored lens attachments may be used with the following System Sensor L-Series plain (non-FIRE-printed) strobe models: P2RL-P, P2WL-P, SRL-P, SWL-P, SPSRL-P, SPSWL-P, SPSCWL-P, or any device used with a non-FIRE printed bezel. Colored Lens Installation Installation to Wall-Mount Strobe Installation to Ceiling-Mount Strobe 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS87001 • 03-17 Part No.Description Colored Lenses LENS-B2 Wall-mount, blue LENS-R2 Wall-mount, red LENS-G2 Wall-mount, green LENS-A2 Wall-mount, amber LENS-BC2 Ceiling-mount, blue LENS-RC2 Ceiling-mount, red LENS-GC2 Ceiling-mount, green LENS-AC2 Ceiling-mount, amber Retrofit Plates (For use with horn strobe & speaker strobe devices) RFPW 9.5" x 7" white RFP 9.5" x 7" red Mounting Plate MP120KL 120 VAC Adapter Mounting Plate Sync Modules MDL3W White, 12/24 volt Sync-Circuit module MDL3R Red, 12/24 volt Sync-Circuit module Trim Rings TR-2 Universal wall trim ring, red, 6.3” x 8.2” TRC-2 Universal ceiling trim ring, red, diameter 8.5” TR-2W Universal wall trim ring, white, 6.3” x 8.2” TRC-2W Universal ceiling trim ring, white, diameter 8.5” Ordering Information Part No.Description Surface Mount Back Box SBBRL Red, wall-mount, compatible with standard horns, strobes, horn strobes, chimes and chime strobes SBBWL White, wall-mount, compatible with standard horns, strobes, horn strobes, chimes and chime strobes SBBSPRL Red, wall-mount, compatible with speakers and speaker strobes SBBSPWL White, wall-mount, compatible with speakers and speaker strobes SBBCRL Red, ceiling-mount compatible with horns, strobe, horn strobes, chimes, chime strobes, speakers and speaker strobes SBBCWL White, ceiling-mount, compatible with horns, strobe, horn strobes, chimes, chime strobes, speakers and speaker strobes SBBGRL Red, wall-mount, compatible with compact horns, strobes, horn strobes SBBGWL White, wall-mount, compatible with compact horns, strobes, horn strobes Bezels* BZR Wall Red Bezel Kit BZW Wall White Bezel Kit BZGR Compact Wall Red Bezel Kit BZGW Compact Wall White Bezel Kit BZRC Horn Strobe Ceiling Red Bezel Kit BZWC Horn Strobe Ceiling White Bezel Kit BZSPR Speaker Wall Red Bezel Kit BZSPW Speaker Wall White Bezel Kit BZSPRC Speaker Ceiling Red Bezel Kit BZSPWC Speaker Ceiling White Bezel Kit *Each bezel pack ships in a package of 5. For desired bezel option add -F (FIRE), -AL (ALERT), -EV (EVAC), -AG (AGENT), -P (Plain), -SP (FUEGO), -PG (FOGO) for desired printing.