CO . 444sta:A SS'S ASS
COUNTY OF HARNETTy,
Building Inspections Department
il Planning Services
Certificate of Compliance: Occupancy: J
4 Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances.
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the 'i,g
North Carolina State Building o s. For the following:
01 Use Class fication:$ Permit Numbers
Name:J.-ft/in/, ( Ion S /.0 , n,1 Building: /.
4
�/ Electrical: ,S.
Address: q// , Insulation: c
q. Plumbing: �j ,P'
Mechanical: 0� 4
MFG Home: D�
,V ip„
DDaatep: ? y —3 — )7 Building
, ,
PREPA$ED 3/02/18, 14:08:30 INSPECTION TICKET PAGE 1
Harnflt Co ity INSPECTOR: IVR DATE 3/05/18
ADDRESS . : 81 FOLLY CT SUBDIV: SWEETWATER 71LOTS
CONTRACTOR : ATLANTIC CONSTRUCTION PHONE : (910) 938-9053
OWNER . . : DIVERSIFIELD INVESTORS INC PHONE :
PARCEL . . : 01-0544- - -0004- -59-
APPL NUMBER: 17-50041034 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 03/27/2017 09:25 AM DJOHNSON --
SWEETWATER LOT 51
T/S: 03/27/2017 09:36 AM DJOHNSON --
STRUCTURE: 000 000 53X40 3BD 2BA SLAB W/GARAGE
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY COUNTY
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
A814 01 10/06/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 003034832
10/06/17 AP 81 FOLLY CT LINDEN 28356
T/S: 10/06/2017 10:04 AM SBENNETT
B101 01 10/06/17 JH R'BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 003034840
10/06/17 AP T/S: 10/05/2017 10 :28 AM LLUCAS
B103 01 10/11/17 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003036720
10/11/17 AP T/S: 10/10/2017 08:17 AM LLUCAS
P309 01 10/18/17 JH R*PLUMB UNDER SLAB TIME: 17:00 VRU #: 003040284
10/18/17 AP T/S: 10/17/2017 09:57 AM BPETRICH
B111 01 10/24/17 JH R*BLDG SLAB INSP/TEMP SVC POLE TIME: 17:00 VRU #: 003042827
10/24/17 AP T/S: 10/23/2017 09:38 AM LLUCAS
R425 01 11/22/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003056710
11/22/17 CA T/S: 11/21/2017 09:09 AM BPETRICH
PER LEE
R425 02 11/28/17 TSG FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003057791
11/28/17 DA T/S: 11/27/2017 08:07 AM LLUCAS
1-ANCHOR BOLTS REQUIRED EACH SIDE OF GARAGE/HOUSE ENTRY
DOOR AND REAR DOOR. 2-SEVERAL DO1 CUT AND BROKEN IN MASTER
BEDROOM 3-ANCHOR TOILET FLANGE IN MASTER BATH. 4-TEST IN
MASTER SHOWER PAN. 5-HEAD TEST DOWN. 6-SEVERAL A02 TRUSS
HAVE HAD THE HEELS CUT OFF. 7-RIGHT REAR GABLE END TRUSS
HEEL CUT OFF. OK TO SIDE DO NOT INSULATE
B104 01 11/30/17 BP R'FOUND & SETBACK VERIF SURVEY TIME: 17:00 VRU #: 003059946
11/30/17 AP T/S: 11/30/2017 10:45 AM BPETRICH
T/S: 11/30/2017 10:45 AM BPETRICH
R425 03 12/05/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003061959
12/05/17 DP T/S: 12/04/2017 12:56 PM LLUCAS
ITEM #3 NOT CORRECTED
I129 01 12/08/17 DT R*INSULATION INSPECTION TIME: 17:00 VRU #: 003063385
12/08/17 AP T/S: 12/07/2017 08:18 AM JBROCK
T/S: 12/08/2017 02 :33 PM DETAYLOR
R425 04 12/08/17 DT FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003063377
12/08/17 AP T/S: 12/07/2017 08:18 AM JBROCK
CONTINUED ONTO NEXT PAGE
PREPARED 3/02/18, 14:08:30 INSPECTION TICKET PAGE 2
Harnqt County INSPECTOR: IVR DATE 3/05/18
ADDRESS . : 81 FOLLY CT SUBDIV: SWEETWATER 71LOTS
CONTRACTOR : ATLANTIC CONSTRUCTION PHONE : (910) 938-9053
OWNER . . : DIVERSIFIELD INVESTORS INC PHONE :
PARCEL . . : 01-0544- - -0004- -59-
APPL NUMBER: 17-50041034 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
T/S: 12/08/2017 02:33 PM DETAYLOR
H824 01 12/19/17 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003074564
12/19/17 AP T/S: 01/09/2018 04:47 PM KHINSON
T/S: 01/09/2018 04:47 PM KHINSON
M305 01 12/29/17 JH R+PLUMB SEWER CONNECTION TIME: 17:00 VRU #: 003071438
12/29/17 AP T/S: 12/28/2017 10:29 AM BPETRICH
P307 01 12/29/17 JH R•PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003071420
12/29/17 AP T/S: 12/28/2017 10:29 AM BPETRICH
R125 01 1/25/18 JH ONE TRADE ROUGH IN TIME: 17:00 VRU #: 003079407
1/25/18 CA T/S: 01/23/2018 01:26 PM DJOHNSON
STONE PREP/LATH INSPECTION
PER LEE
R125 02 1/26/18 JH ONE TRADE ROUGH IN TIME: 17:00 VRU #: 003080694
1/26/18 AP T/S: 01/25/2018 10:05 AM JBROCK
LATH INSPECTION
E209 01 2/01/18 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003082682
2/01/18 DA T/S: 01/30/2018 09:09 AM BPETRICH
1)Mark neutural in panel in garage.2)Light in back right
bed closet closer than 12" to shelf.
E209 02 2/06/18 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003084191
2/06/18 AP T/S: 02/01/2018 09:18 AM BPETRICH
R429 01 2/15/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003088762
2/15/18 DA T/S: 02/13/2018 09:30 AM BPETRICH
Steps in garage & back are not to code.2)Energy certificate
not filled out.
R429 02 3/01/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003095338
3/01/18 CA T/S: 02/27/2018 02 :44 PM LLUCAS
PER LEE
R429 03 3/05 18 T FOUR TRADE FINAL TIME: 17:00 VRU #: 003096427
P T/S: 03/01/2018 01:09 PM JBROCK
/ COMMENTS AND NOTES