Loading...
Untitled / Harnett 2_5 �("� COUNTY Plan Review, Inspection, and Permit Fees Application Number 18-50043601 $100.00 ❑ DRB Major Sub Division Prelim Site Plans $ $200.00 El Explosive Material (90 Days) _ $100.00 ❑ Explosive Materials (72 Hours) $ $100.00 ❑ Fireworks Public Display $ $50.00 O Final Inspection $ $35.00 +$2.00per device ❑ Fire Alarm Testing $ 50.00 $35.00 +$2.00 per nozzle C Fixed Fire Su $ $75.00 ❑ Suppression $ Insecticide Fog/Fumigation $100.00 ❑ Pipe Test/UST/AGST $ $50.00 O Plans up to 5000 sq ft $ $100.00 0 Plans 5001 sq ft to 10,000 sq ft $ 50.00 $150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft $ _ $250.00 ❑ Plans 25,001 sq ft and over $ $35.00 +2.00 per head ❑ Sprinkler Certification Test $ $50.00 ❑ Standpipe Testing $ $ $50.00 ❑ Special Assembly (ie.amusement buildings,carnivals,fairs) $ $75.00 El Tents/Canopies/Air Supported Structure $100.00 El $ Tank Installation (charge for each tank) $100.00 C Tank Removal (charge for each tank) $ _ Total Devices/Heads Total Cost $ - $ 100.00 Code Enforcement Official Bill Lamm 4/5/2018 HaMrnett COUNTY �1 (F Emergency Services Department er www.harnett.ory Fire Marshal Division 040/05/2018 Jon Cox 2012 Day Flower Drive Salemburg, NC 28385 Re: Stage Road Animal Hospital 7580 Old Stage Road N Angier, NC 27501 Application Number 18-50043601 To whom it may concern, Thank you for submitting the plans for Stage Road Animal Hospital. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 505.1 Physical Address o The physical address of the building shall be posted in a conspicuous place so that it can be seen on approach from the road, access road, and/or parking lot. o The numbers used to make up the physical address shall be at least 6 inches in height. • 506.1 Knox Box o A secure key box shall be installed on the new building that houses all keys to all the doors within the building in which the fire department would need access to in the event of an emergency. o Knox Box ID stickers shall be placed on all exterior doors in which entry to the building may be gained. o The box shall be mounted not to exceed 48 —60 inches in height. o The basic model for the buildings should be at least a selection from the 3200 Series listed on the order form. • Itltps:Iwww.knoxbox.corn/store/departmentSearch.cfm • Fire Extinguishers ti Harnett COUNTY IFMfnw'9ancy SWAMI Department arnattorg o Fire Extinguishers shall be 2A:20BC and shall be placed with a travel distance to not exceed 75' o Fire extinguishers are to be mounted no higher than 5' above the finished floor. o Place one 2A:20BC fire extinguisher on second floor. • 1006.1 Illumination Required o The exit discharge shall be illuminated at all times the building spaces served by the means of egress is occupied o Illumination level in all areas of the means of egress shall not be less than 1 foot-candle at the walking surface and shall have emergency power supply. o Install exit sign on second floor stairway entrance o Install emergency lights on second floor. • Notes o Building code summary sheet is not completed. o Submit life safety plan. o A final fire inspection is required. Please contact this office direct to schedule fire inspection at 910-593-0743. Thank you again for submitting the plans for Stage Road Animal Hospital. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office Again, thank you and we look forward to working with you during the construction period! Sincerely, Roger Sullivan Deputy Fire Marshal • ,/" ,, Harnett —)C• COUNTY fFMf Emollient"linim Deparbnnnt 10411.. tAFG.!kp naltf rnncaq '' Application for Plan Revie 7'5 a �T�I 1 1 - Application# 11 - �17V"13U1o1�,t _ Date Received: 3- 2-0- I Y Received By: thA Name of Project: S{rr )til an imc,i H-bz r; ,I Physical Address of Project: 7Slio O (d S Rcl N Fely-lir( , NC Plans Submitted By: 70Y, C o)C Project Phone: (Q)q )- 7-oI - 2-4e Lr.¢ Contact Person/Address: Torte Ccix zo12- pw Fit vin DC Cie,'Ito . Nc 2.7c20 Contact Email: ,IP-COX ILI p liJc,Con.. Contact Phone: ( 'ii )- 2ot - zvz.ce ( )- - Contractor's Name/Info: J6r. C ox 2olz A'y nowt/ br e/ey -fan. NL Z75-2-o Contractor's Phone: ( `I l Q )_ Zo i - '2,C,24 • Plans that are submitted will be reviewed as quickly as possible with an average time of review between 7-10 working days. • Status checks may be conducted on plan reviews by visiting the website httP://hteweb.hamett.org/Click2GovBP/Index.isp or by calling the Hamett County Central Permitting Office(910-893-7525, Option#2),or the Harnett County Fire Marshal's Office (910-893-7580). • Approved plans must be picked up from the Central Permitting Office and all fees paid before any required inspections can be conducted.