Loading...
DOCUMENTS Imtlm App&ulbn Dam:(---1 l DII 7 Appi n# 1 • 5OO4373/ l Cw COUNTY OF HARNETT RESIDENTIAL LAND USE APPLICATION Centel Permitting 108 E.Frond Week Ulli glop.NC 27546 Phone:(910)8917525 mat Fax:ENO)8932789 va.Mmatcorgpernls "A RECORDED SURVEY NAP,RECOIDED DEED(OR OFFER TO PURCHASE)8 SITE PUN ARE REWIREDWHEN SUMERPIG A LAND USE APPUCATDN` LANDOWNER' Paul Kook Ma0Ing Address: 2554 Comahury Rd City: State:Varma Slam:NC Zip: Contact Contact Na 919-7709106 Fid: tc3hmwkeye®YehOO.Ccm APPLICANT:Terre Sommers MangAdak 115 Galina Mey#109 City: State'Slab.NC Zip: Contact Coiled No: 88&935-5505 Email: 'Fiala m out applI n btme ai it anal nal eal larevmm 88835-5505 CONTACT NAME APPLYING IN OFFICE:Terre Sommers Plnorne# 9 PROPERTY LOCATION:Subdivision: Ne Lott. Lot She • State Road#5562 State Road Nene: Cokaebury Rd Map Book S Page: Farrel: 050535030902 PIN: 0635.563031 Zoning:HA30 Flood Zone:MlnlmurWelarenae: Deed Bok!Pape. 3501 1396 Pater Conpany: Duke Energy New Sucks Mth Progress Energy ea service war need m supply premise nember We ProWass Energy. PROPOSED USE: Monolithic O SFO:(She Sri Bedtimes_I Berms:_BenIerICWMO beth):_Gmape:_Deck;_CrSM Space:_Slab`315E-- (Is the ab`Mfle bonus room mtlehed?U yes (J no Ma closet?L yes (_J no Of yes adder Mth•bebaoma) O Mod(Size S* (Mwo bath)_Garage:_Ste BUM Deck:_ On Frame Olt Franc_ (Is the second floor SSW Ll yes Li no My Ober it bunt additions?U yea Li no O Manufactured Home:_SW_ W_1W(Size x )IBedrooms:_Garape:_(Nm bdk7.)Der1c_(Blte D DIplex:(Size s)No.BUMh9e: No.Bedrooms Per 1St a Home Occupation:I Rooms: Use' Han of Operation ttEmployses:, Adtl6mrUAaawrynOR:(She x 1 IAD Residential solar Closets It addition?(__)Yes L)no Water Supply /1 County _Ethang WM —New NAti(1a/Meage using wee )Vest have operable water More final Sewage Supply: New Septic Tads(Caleb ChackaiO —Existing Septic Tart(Casaba CAsdWeO _County Sewer Does www of Bra trail of land,ata land that onWre a manufactured Mme vAWn lye hundred feet WO)oftract listed above?L)yes ( )no Does the properly conth may easements Sather ueeground or overhead Li nes Li re Structures(eSOng or proposed):Single Way Mang* Meelecleed Homes: Other(aped)»' Required Residential Property Use Setbacks: Common:Adding 35 ground mounted solar modules,10.16kw Front Minimum Actual_ Rear Closest SMe SideMetner tit Nearest Bolding on Deme tit Residential Land Use Application Papa 1 old U3/11 APPLICATION CONTINUES ON BACK SPECIFIC DIRECTIONS TO THE PROPERTY PROM LILLINOTON: Head N on S Main St toward E Remelt SIN Turn L onto McKinney Pkwy l/Tum L onto US-401N//Turn L onto Christian Light Rd/I TUm L onto Columbary Rd/I Continue straight b stay on Cokeebury Rdll N pods ant granted I agree to conform to all ordinances and lass of the Stab of NOM Carolina regulayrlp such work and the spodfcations of plans submitted. I hereby state that fsegcleg statements are accurate and caned to the best of my lopwbdpe. Pemll$Wjed to revocation If false lyddmadon Is prodded. •O.RMM 4- .B Bvvt.Uu4.t/d" 4/3/2018 Slgrwture of Owner or Owners Agent Date µIt Is the onnMapplicents responsibility to provide the county with any applicably)bfarmados about the subject properly.Inducibug but not limited to:boundary Information,how location,underground or ove hnd enwnants,etc.The county or Its employees M not responsible for any Incorrect or mining bdomedon that le contained within these applications.µ "This application expires a monde from the Initial dab If permits have not been Inured Residential Land Use application Page 2 of g 03111 +CClarrtrsPecs .solar - appiica.wt 09109(11 Application# Harnett County Central Permitting Each aecban below to be filled out PO Box 65 Lillington NC 27546 910 893 7525 Fax 910 893 2793 www hamett orgipermits by whomever performing work Must be owner or licensed contractor Address company Application for Residential Building and Trades Permit name 8 phone must match Owners Name Paul Kosik Date Site Address 5542 Cokesbury Rd Varina,NC 27526 Phone 919-770-9404 Directions to job site from Lillington Take US-401 N and Christian Li!ht Rd to Oakridce River Rd in Buckhorn. Turn L onto Oakridge River Rd. Turn R onto Cokesbury Rd.Continue straight to stay on Cokesbury Rd. Subdivision Lot Description of Proposed Work Adding 35 roof mounted modules, 10.15kw #of Bedrooms _ Heated SF Unheated SF Finished Bonus Room' Crawl Space Slab General Contractor Information Kelly Miles 7049608110 Building Contractors Company Name Telephone 116 Gasoline Alley Suite 109 Mooresville,NC 28117 kbmiles92@aol.com Address Email Address 51355 License# Electrical Contractor Information Description of Work Service Size Amps T-Pole _Yes_No Lighting Electric - Kevin Kutsch 704-361-ROl I Electrical Contractor s Company Name Telephone 230 Blacksnake Rd Stanley,NC 28164 liehtingelectricl@gmail.com Address Email Address 29517 License# MechanicallHVAC Contractor Information Description of Work Mechanical Contractors Company Name Telephone Address Email Address License# Plumbing Contractor Information Description of Work #Baths Plumbing Contractors Company Name Telephone Address Email Address License# Insulation Contractor Information Insulation Contractors Company Name&Address Telephone 'NOTE General Contractor must fill out and sign the second page of this application t tit I hereby certrfy that I have the authority to make necessary application that the application is correct and that-the construction will conform to the regulations in the Building Electrical Plumbing and Mechanical codes and the Harnett County Zoning Ordinance I state the information on the above contractors is correct as known to me and that by signing below I have obtained all subcontractors permission to obtain these permits and if azi changes occur including listed contractors site plan number of bedrooms building and trade plans Environmental Health permit changes or proposed use changes I certify it is my responsibility to notify the Harnett County Central Permitting Department of any and all changes EXPIRED PERMIT FEES-6 Months to 2 years permit re-issue fee is$150 00 After 2 years re-issue fee is as per current fee schedule 3/27/2018 Signature of Owner/Contractor/Officer(s)of Corporation Date Affidavit for Worker's Compensation NC G S 87-14 The undersigned applicant being the General Contractor _Owner x Officer/Agent of the Contractor or Owner Do hereby confirm under penalties of perjury that the person(s) firm(s)or corporation(s)performing the work set forth in the permit Has three(3)or more employees and has obtained workers compensation insurance to cover them Has one(1)or more subcontractors(s)and has obtained workers compensation insurance to cover them x Has one(1)or more subcontractors(s)who has their own policy of workers compensation insurance covering themselves Has no more than two(2)employees and no subcontractors While working on the project for which this permit is sought it is understood that the Central Permitting Department issuing the permit may require certificates of coverage of workers compensation insurance pnor to issuance of the permit and at any time dunng the permitted work from any person firm or corporation carrying out the work Company or Na - Ene • Conservation Solutions Sign w/Title ',, , II Jl Date 3/27/2018 V' Application# _ Harnett County Central Permitting PO Box 65 Lillington, NC 27546 - Ph:910-893-7525 - Fx:910-893-2793 - www.hamett.org/permits Certification of Work Performed By Owner/Contractor (Individual Trade Application) Owner(s)of Structure: Paul Kosik Phone:919-770-9404 Owner(5) Mailing Address:5542 Cokesbury Rd Fuquay Varina, NC 27526 Land Owner Name(s): Paul Kosik Phone:919-770-9404 Construction or Site Address:5542 Cokesbury Rd Fuquay Varina, NC 27526 PIN# 0635-54-3034 Parcel# 050635 0309 02 Job Cost: 60460 Description of Work to be done Adding 35 roof mounted modules,grid-tied, 10.15kw solar installation on existing Mechanical: New Unit With Ductwork_ New Unit Without Ductwork_ Gas Piping_Other Electrical*: 200 Amp_<200 Amp_Service Change_ Service Reconnect_ Other " For Progress Energy customers we need the premise number Plumbing: Water/Sewer Tap Number of Baths Water Heater Specific Directions to Job from Lillington: Take US-401N and Christian Light Rd to Oakridge River Rd in Buckhorn. Turn L onto Oakridge River Rd.Turn R onto Cokesbury Rd. Continue straight to stay on Cokesbury Rd Subdivision: Lot#: I Kevin Kutsch will provide the Electrical labor on this structure. (Contractors Name) (Trade) I am the building owner or my NC state license number is 29511 ,which entitles me to perform such work on the above structure legally. All work shall comply with the State Building Code and all other applicable State and local laws, ordinances and regulations. Lighting Electric 704-361-8011 Contractor's Company Name Telephone 230 Blacksnake Rd Stanley, NC 28164 lightingelectric1@gmail.com Address Email Address 29517 License# Structure Owner/Contractor Signature: Date:3/27/2018 By signing this application you affirm that you have obtained permission from the above listed license holder to purchase permits on their behalf. If doing the work as owner you understand that you cannot rent, lease or sell the listed property for 12 months after completion of the listed work. `Company name, address, & phone must match information on license DocuSign Envelope ID:7DF 10079-2F63-491 D-A346-52ECI C4BFFBB Interconnection Request Application Form for Interconnecting a Certified Inverter-Based Generating Facility No Larger than 20 kW This Interconnection Request Application Form is considered complete when it provides all applicable and correct information required below. Additional information to evaluate the Interconnection Request may be required. Processing Fee A non-refundable processing fee of $100 must accompany this Interconnection Request Application Form. If the Interconnection Request is submitted solely due to a transfer of ownership of the Generating Facility, the fee is $50. Interconnection Customer Name: Paul Kosik Contact Person: Taylor Granelle Email Address: fc3hawkeye@yahoo.com Address: 5542 Cokesbury Rd. City: Fuquay Varina State: NC Zip: 27526 County: Harnett Telephone (Day): 9197709404 (Evening): Fax: Contact (if different than Interconnection Customer) Name: Gene Granelle Email Address: tgranelle@ecs.solar Address: 116 Gasoline Alley STE 109 City: Mooresville State: NC Zip: 28117 County: Iredell Telephone (Day): 7042300498 (Evening): Fax: Owner(s) of the Generating Facility: 1 NC 20 kW Inverter DocuSign Envelope ID:7DF10079-2F63-491 D-A346-52EC1 C4BFFBB Generating Facility Information Facility Location (if different from above): Address: 5542 Cokesbury Rd. City: Fuquay Varina State: NC Zip: 27526 County: Harnett Utility Duke Energy Progress Account Number: 8954002864 For photovoltaic sources only: Inverter Manufacturer: Inverter: 35 x Enphase Energy 0.2 kW(Model IQ6- Model: 60-X-US (240V)) Total panel capacity: Inverter Rating (ea): 0.23 kW AC Efficiency: 97% Nameplate Rating (each inverter): PV Module Array: 35 x SolarWorld 290W (Model SW 290 Mono Black) Module Rating (ea): 290 W DC, 266.1 W PTC Tilt: 30 Azimuth: 3 Tracking: Fixed Nameplate Rating: 10.15 kW DC AC Rating: 9.034 kW CEC-AC Estimated Annual Production: 9254 kWh Design Factor: 60.3 % 12.687 kVA(Ac) (each inverter) 240 VoItsiAcl (each inverter) Phase: System Design Capacity: 12.687kVA(Ac) Maximum Physical Export kW(Ac) Capability Requested: Prime Mover Photovoltaic ENERGY SOURCE TABLE Renewable Non-Renewable H-1. Solar— Photovoltaic Is the equipment UL 1741 Listed? 2 NC 20 kW Inverter Docusign Envelope ID:70F10079-2F63-491 D-A346-52ECIC4BFFB6 If Yes, attach manufacturer's cut-sheet showing UL 1741 listing Estimated Installation Date 4/5/2018 Estimated In-Service Date 4/26/2018 The 20 kW Inverter Process is available only for inverter-based Generating Facilities no larger than 20 kW that meet the codes, standards, and certification requirements of Attachments 3 and 4 of the North Carolina Interconnection Procedures, or the Utility has reviewed the design or tested the proposed Generating Facility and is satisfied that it is safe to operate. List components of the Generating Facility equipment package that are currently certified: Number Equipment Type Certifying Entity 1. 2. 3. 4. 5. 3 NC 20 kW Inverter DocuSign Envelope ID:7DF10079-2F63491 D-A346-52ECI C4BFFB8 Interconnection Customer Signature I hereby certify that, to the best of my knowledge, the information provided in this Interconnection Request Application Form is true. I agree to abide by the Terms and Conditions for Interconnecting a Certified Inverter-Based Generating Facility No Larger than 20 kW and return the Certificate of Completion when the Generating Facility has been installed. signed by; Signec: P' tztsi(c Title: Date: 3120/2018 4 NC 20 kW Inverter DocuSign Envelope ID'.70F10079-2F63-491D-A346-52EC1C4BFFB8 Terms and Conditions for Interconnecting a Certified Inverter-Based Generating Facility No Larger than 20 kW 1.0 Construction of the Facility The Interconnection Customer (Customer) may proceed to construct (including operational testing not to exceed two hours) the Generating Facility when the Utility approves the Interconnection Request and returns it to the Customer. 2.0 Interconnection and Operation The Customer may interconnect the Generating Facility with the Utility's System and operate in parallel with the Utility's System once all of the following have occurred: 2.1 Upon completing construction, the Customer will cause the Generating Facility to be inspected or otherwise certified by the appropriate local electrical wiring inspector with jurisdiction, and 2.2 The Customer returns the Certificate of Completion to the Utility, and 2.3 The Utility has either: 2.3.1 Completed its inspection of the Generating Facility to ensure that all equipment has been appropriately installed and that all electrical connections have been made in accordance with applicable codes. All inspections must be conducted by the Utility, at its own expense, within ten Business Days after receipt of the Certificate of Completion and shall take place at a time agreeable to the Parties. The Utility shall provide a written statement that the Generating Facility has passed inspection or shall notify the Customer of what steps it must take to pass inspection as soon as practicable after the inspection takes place; or 2.3.2 If the Utility does not schedule an inspection of the Generating Facility within ten Business Days after receiving the Certificate of Completion, the witness test is • deemed waived (unless the Parties agree otherwise); or 2.3.3 The Utility waives the right to inspect the Generating Facility. 5 NC 20 kW Inverter DocuSign Envelope ID:70F10079-2F63-491 D-A346-52EC1 C4BFFB8 2.4 The Utility has the right to disconnect the Generating Facility in the event of improper installation or failure to return the Certificate of Completion. 2.5 Revenue quality metering equipment must be installed and tested in accordance with applicable American National Standards • Institute (ANSI) standards and all applicable regulatory requirements. 3.0 Safe Operations and Maintenance The Customer shall be fully responsible to operate, maintain, and repair the Generating Facility as required to ensure that it complies at all times with the interconnection standards to which it has been certified. 4.0 Access The Utility shall have access to the disconnect switch (if a disconnect switch is required) and metering equipment of the Generating Facility at all times. The Utility shall provide reasonable notice to the Customer, when possible, prior to using its right of access. 5.0 Disconnection The Utility may temporarily disconnect the Generating Facility upon the following conditions: 5.1 For scheduled outages upon reasonable notice. 5.2 For unscheduled outages or emergency conditions. 5.3 If the Generating Facility does not operate in a manner consistent with these Terms and Conditions. 5.4 The Utility shall inform the Customer in advance of any scheduled disconnection, or as soon as is reasonable after an unscheduled disconnection. 6.0 Indemnification The Parties shall at all times indemnify, defend, and save the other Party harmless from, any and all damages, losses, claims, including claims and actions relating to injury to or death of any person or damage to property, demand, suits, recoveries, costs and expenses, court costs, attorney fees, and all other obligations by or to third parties, arising out of or resulting from the other Party's action or inactions of its obligations hereunder on 6 NC 20 kW Inverter DocuSign Envelope ID:7DF10079-2F63-4910-A346-52EC1C4BFFB6 behalf of the indemnifying Party, except in cases of gross negligence or intentional wrongdoing by the indemnified Party. 7. 0 Insurance All insurance policies must be maintained with insurers authorized to do business in North Carolina. The Parties agree to the following insurance requirements: 7.1 If the Customer is a residential customer of the Utility, the required coverage shall be a standard homeowner's insurance policy with liability coverage in the amount of at least $100,000 per occurrence. 7.2 For an Interconnection Customer that is a non-residential customer of the Utility proposing to interconnect a Generating Facility no larger than 250 kW, the required coverage shall be comprehensive general liability insurance with coverage in the amount of at least $300,000 per occurrence. 7.3 The Customer may provide this insurance via a self-insurance program if it has a self-insurance program established in accordance with commercially acceptable risk management practices. 8.0 Limitation of Liability Each Party's liability to the other Party for any loss, cost, claim, injury, or expense, including reasonable attorney's fees, relating to or arising from any act or omission hereunder, shall be limited to the amount of direct damage actually incurred. In no event shall either Party be liable to the other Party for any indirect, special, incidental, consequential, or punitive damages of any kind. 9.0 Termination The agreement to interconnect and operate in parallel may be terminated under the following conditions: 9.1 By the Customer By providing written notice to the Utility and physically and permanently disconnecting the Generating Facility. 9.2 By the Utility If the Generating Facility fails to operate for any consecutive 12-month period or the Customer fails to remedy a violation of these Terms and Conditions. 7 NC 20 kW Inverter DocuSign Envelope ID:7DF10079-2F63-491D-A346-52EC1C4BFF B8 9.3 Permanent Disconnection In the event this Agreement is terminated, the Utility shall have the right to disconnect its facilities or direct the Customer to disconnect its Generating Facility. 9.4 Survival Rights This Agreement shall continue in effect after termination to the extent necessary to allow or require either Party to fulfill rights or obligations that arose under the Agreement. 10.0 Assignment/Transfer of Ownership of the Facility 10.1 This Agreement shall not survive the transfer of ownership of the Generating Facility to a new owner. 10.2 The new owner must complete and submit a new Interconnection Request agreeing to abide by these Terms and Conditions for interconnection and parallel operations within 20 Business Days of the transfer of ownership. The Utility shall acknowledge receipt and return a signed copy of the Interconnection Request Application Form within ten Business Days. 10.3 The Utility shall not study or inspect the Generating Facility unless the new owner's Interconnection Request Application Form indicates that a Material Modification has occurred or is proposed. 8 NC 20 kW Inverter Docusign Envelope ID:336E49E8-5A07-4F9B-9071-7246E0851600 Attachment 6 Contingent Approval to Interconnect the Generating Facility (For Utility use onlyl Interconnection of the Generating Facility is approved contingent upon the Terms and Conditions for Interconnecting a Certified Inverter-Based Generating Facility No Larger than 20 kW and return of the Certificate of Completion. �000uslyned by: Utility Signature: Usstr `8ese5o3eoo0347o.. Title: Smart Energy Specialist Date: 3/26/2018 Interconnection Request ID number: INTCO-09077 Utility waives inspection/witness test? No NC 10 kW Inverter Process 1