CO ,ft ., -,.
itattets,A+1, ,(, , is,,, ,s,,, , ,, , 4
COUNTY OF HARNETT
Building Inspections Department
Planning Servicesph
Certificate of Compliance: Occupancy: /
Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances.
This certifies at the time of issuance.this structure was in compliance with the various ordinances of the County of Harnett and the t.#
North Carolina State Building Codes.✓lFor the following: A
Use Class'fication:5 rU Permit Numbers
Name: a PPS /S',u, i
%de 5 2274 Budding:
/ Electrical: /)
4
Address: /o/ %un p U/ Insulation: -S
end j
Mechanical: �7-
, 7 MFG Home: / / O/
Date: 3 - f _ / c Building Official: �, ,�, 2/ L1 9
PREPARED 2/28/10, 14:17:10 INSPECTION TICKET PAGE 5
Harnett County INSPECTOR: IVR DATE 3/01/18
•ADDRESS : 701 JUNG DR SUBDIV: TINGEN POINTE PH6
CONTRACTOR : PHONE :
OWNER . . : THE HARNETT LAND GROUP II LLC PHONE :
PARCEL . . : 03-9576-01- -0088- -85-
APPL NUMBER: 17-50040801 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 02/22/2017 04:00 PM JBROCK ----
TINGEN POINTE #173 - 701 JUNO DR
T/S: 08/24/2017 01:30 PM BPETRICH --
PREMISE 493138530
STRUCTURE: 000 000 43X40 4BDR MONO G/ GARAGE
FLOOD ZONE - FLOOD ZONE X
# BEDROOMS • 4000000.00 PROPOSED USE • SFD
SEPTIC - EXISTING NEW TANK WATER SUPPLY • COUNTY
PRRMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
A814 01 9/14/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 003024338
9/14/17 AP 701 JUNO DR BROADWAY 27505
T/S: 09/14/2017 09:04 AM SBENNETT
B101 01 9/14/17 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 003024346
9/14/17 DA T/S: 09/13/2017 07:55 AM JBROCK
check t-pole please
Dig footings down per engineer letters for each lot and
clean out all loose dirt.
8101 02 9/19/17 TSG R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 003025814
9/19/17 AP T/S: 09/15/2017 07:37 AM JBROCK
T/S: 09/19/2017 04:02 PM BPETRICH
8103 01 10/04/17 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003033149
10/04/17 AP T/S: 10/02/2017 04:22 PM JBROCK
P309 01 10/18/17 TSG R*PLUMB UNDER SLAB TIME: 17:00 VRU #: 003039831
10/18/17 AP T/S: 10/16/2017 11:45 AM JBROCK
T/S: 10/18/2017 03:14 PM BPETRICH
B111 01 10/25/17 JH R*BLDG SLAB INSP/TEMP SVC POLE TIME: 17:00 VRU #: 003043510
10/25/17 AP T/S: 10/24/2017 10:10 AM JBROCK
B104 01 10/26/17 JB R*FOUND & SETBACK VERIF SURVEY TIME: 17:00 VRU #: 003045598
10/26/17 AP T/S: 10/26/2017 02 :02 PM JBROCK
R425 01 11/30/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003059110
11/30/17 DA T/S: 11/29/2017 07:44 AM JBROCK
1)Missing air barriers in garage at stairs.2)Strap all 4ply
stud columns.3)Missing nail guards & fire caulk @ top &
bottom plate in half bath.4)Missing anchor bolts on back
wall in living room.5)Install porch post per plans.6)Nail
loose osb in stair landing.7)Replace all short nails in
hangers with correct size nails.8)Nail 2ply trusses per
truss documents.9)Missing stud under top plate joint in
back left bed closet.10)Missing hurricane straps on 2ply
truss in garage.11)Missing house wrap on house.
do not insulate or side.
R425 02 12/12/17 TSG FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003064540
12/12/17 DA T/S: 12/11/2017 07:40 AM JBROCK
ALL COLOUMS 4 OR MORE NOT STRAPED
CONTINUED ONTO NEXT PAGE
PREPARED 2/28/18, 14 :17:10 INSPECTION TICKET PAGE 6
Harnett County INSPECTOR: IVR DATE 3/01/18
ADDRESS : 701 JUNO DR SUBDIV: TINGEN POINTE PH6
CONTRACTOR : PHONE :
OWNER . . : THE HARNETT JLND GROUP II LLC PHONE :
PARCEL . . : 03-9576-01- -0088- -85-
APPL NUMBER: 17-50040801 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
OK TO INSULATE AND SIDE
I129 01 12/14/17 KS R*INSULATION INSPECTION TIME: 17:00 VRU #: 003065836
12/14/17 AP T/S: 12/12/2017 10:18 AM LLUCAS
T/S: 12/12/2017 10:19 AM LLUCAS
T/S: 12/14/2017 11:55 AM KSLATTUM
R425 03 12/14/17 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003065844
12/14/17 AP T/S: 12/12/2017 10:18 AM LLUCAS
T/S: 12/12/2017 10:19 AM LLUCAS
T/S: 12/14/2017 11:55 AM KSLATTUM
P307 01 1/11/18 JH R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003074655
1/11/18 DA T/S: 01/10/2018 08:59 AM LLUCAS
NOT CONNECTED AT TAP
R125 01 1/16/18 TSG ONE TRADE ROUGH IN TIME: 17:00 VRU #: 003075843
1/16/18 AP T/S: 01/12/2018 09:02 AM LLUCLS
STONE PREP
E213 01 2/01/18 TSG R*ELECTRICAL UNDERGROUND TIME: 17:00 VRU #: 003083375
2/01/18 AP T/S: 01/30/2018 04:01 PM JBROCK
M305 01 2/01/18 TSG R*PLUMB SEWER CONNECTION TIME: 17:00 VRU #: 003083391
2/01/18 AP T/S: 01/30/2018 04 :01 PM JBROCK
P307 02 2/01/18 TSG R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003083409
2/01/18 AP T/S: 01/30/2018 04 :01 PM JBROCK
E209 01 2/08/18 TSG R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003086667
2/08/18 AP T/S: 02/07/2018 12 :53 PM LLUCAS
There will be a lock box on lot 173 that will have a key in
it to get into both lots. The code is 7798.
T/S: 02/08/2018 03 :06 PM SGUY
H824 01 2/27/18 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003095569
2/27/18 AP T/S: 02/28/2018 10:54 AM KHINSON
T/S: 02/28/2018 10:54 AM KHINSON
R429 01 3/01/18 FOUR TRADE FINAL TIME: 17:00 VRU #: 003095619
T/S: 02/28/2018 11:03 AM LLUCAS
LOCKBOX CODE47798 - KEY WILL GET YOU IN BOTH HOUSES
COMMENTS AND NOTES