Loading...
CO ,ft ., -,. itattets,A+1, ,(, , is,,, ,s,,, , ,, , 4 COUNTY OF HARNETT Building Inspections Department Planning Servicesph Certificate of Compliance: Occupancy: / Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances. This certifies at the time of issuance.this structure was in compliance with the various ordinances of the County of Harnett and the t.# North Carolina State Building Codes.✓lFor the following: A Use Class'fication:5 rU Permit Numbers Name: a PPS /S',u, i %de 5 2274 Budding: / Electrical: /) 4 Address: /o/ %un p U/ Insulation: -S end j Mechanical: �7- , 7 MFG Home: / / O/ Date: 3 - f _ / c Building Official: �, ,�, 2/ L1 9 PREPARED 2/28/10, 14:17:10 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 3/01/18 •ADDRESS : 701 JUNG DR SUBDIV: TINGEN POINTE PH6 CONTRACTOR : PHONE : OWNER . . : THE HARNETT LAND GROUP II LLC PHONE : PARCEL . . : 03-9576-01- -0088- -85- APPL NUMBER: 17-50040801 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 02/22/2017 04:00 PM JBROCK ---- TINGEN POINTE #173 - 701 JUNO DR T/S: 08/24/2017 01:30 PM BPETRICH -- PREMISE 493138530 STRUCTURE: 000 000 43X40 4BDR MONO G/ GARAGE FLOOD ZONE - FLOOD ZONE X # BEDROOMS • 4000000.00 PROPOSED USE • SFD SEPTIC - EXISTING NEW TANK WATER SUPPLY • COUNTY PRRMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS A814 01 9/14/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 003024338 9/14/17 AP 701 JUNO DR BROADWAY 27505 T/S: 09/14/2017 09:04 AM SBENNETT B101 01 9/14/17 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 003024346 9/14/17 DA T/S: 09/13/2017 07:55 AM JBROCK check t-pole please Dig footings down per engineer letters for each lot and clean out all loose dirt. 8101 02 9/19/17 TSG R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 003025814 9/19/17 AP T/S: 09/15/2017 07:37 AM JBROCK T/S: 09/19/2017 04:02 PM BPETRICH 8103 01 10/04/17 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003033149 10/04/17 AP T/S: 10/02/2017 04:22 PM JBROCK P309 01 10/18/17 TSG R*PLUMB UNDER SLAB TIME: 17:00 VRU #: 003039831 10/18/17 AP T/S: 10/16/2017 11:45 AM JBROCK T/S: 10/18/2017 03:14 PM BPETRICH B111 01 10/25/17 JH R*BLDG SLAB INSP/TEMP SVC POLE TIME: 17:00 VRU #: 003043510 10/25/17 AP T/S: 10/24/2017 10:10 AM JBROCK B104 01 10/26/17 JB R*FOUND & SETBACK VERIF SURVEY TIME: 17:00 VRU #: 003045598 10/26/17 AP T/S: 10/26/2017 02 :02 PM JBROCK R425 01 11/30/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003059110 11/30/17 DA T/S: 11/29/2017 07:44 AM JBROCK 1)Missing air barriers in garage at stairs.2)Strap all 4ply stud columns.3)Missing nail guards & fire caulk @ top & bottom plate in half bath.4)Missing anchor bolts on back wall in living room.5)Install porch post per plans.6)Nail loose osb in stair landing.7)Replace all short nails in hangers with correct size nails.8)Nail 2ply trusses per truss documents.9)Missing stud under top plate joint in back left bed closet.10)Missing hurricane straps on 2ply truss in garage.11)Missing house wrap on house. do not insulate or side. R425 02 12/12/17 TSG FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003064540 12/12/17 DA T/S: 12/11/2017 07:40 AM JBROCK ALL COLOUMS 4 OR MORE NOT STRAPED CONTINUED ONTO NEXT PAGE PREPARED 2/28/18, 14 :17:10 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 3/01/18 ADDRESS : 701 JUNO DR SUBDIV: TINGEN POINTE PH6 CONTRACTOR : PHONE : OWNER . . : THE HARNETT JLND GROUP II LLC PHONE : PARCEL . . : 03-9576-01- -0088- -85- APPL NUMBER: 17-50040801 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS OK TO INSULATE AND SIDE I129 01 12/14/17 KS R*INSULATION INSPECTION TIME: 17:00 VRU #: 003065836 12/14/17 AP T/S: 12/12/2017 10:18 AM LLUCAS T/S: 12/12/2017 10:19 AM LLUCAS T/S: 12/14/2017 11:55 AM KSLATTUM R425 03 12/14/17 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003065844 12/14/17 AP T/S: 12/12/2017 10:18 AM LLUCAS T/S: 12/12/2017 10:19 AM LLUCAS T/S: 12/14/2017 11:55 AM KSLATTUM P307 01 1/11/18 JH R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003074655 1/11/18 DA T/S: 01/10/2018 08:59 AM LLUCAS NOT CONNECTED AT TAP R125 01 1/16/18 TSG ONE TRADE ROUGH IN TIME: 17:00 VRU #: 003075843 1/16/18 AP T/S: 01/12/2018 09:02 AM LLUCLS STONE PREP E213 01 2/01/18 TSG R*ELECTRICAL UNDERGROUND TIME: 17:00 VRU #: 003083375 2/01/18 AP T/S: 01/30/2018 04:01 PM JBROCK M305 01 2/01/18 TSG R*PLUMB SEWER CONNECTION TIME: 17:00 VRU #: 003083391 2/01/18 AP T/S: 01/30/2018 04 :01 PM JBROCK P307 02 2/01/18 TSG R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003083409 2/01/18 AP T/S: 01/30/2018 04 :01 PM JBROCK E209 01 2/08/18 TSG R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003086667 2/08/18 AP T/S: 02/07/2018 12 :53 PM LLUCAS There will be a lock box on lot 173 that will have a key in it to get into both lots. The code is 7798. T/S: 02/08/2018 03 :06 PM SGUY H824 01 2/27/18 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003095569 2/27/18 AP T/S: 02/28/2018 10:54 AM KHINSON T/S: 02/28/2018 10:54 AM KHINSON R429 01 3/01/18 FOUR TRADE FINAL TIME: 17:00 VRU #: 003095619 T/S: 02/28/2018 11:03 AM LLUCAS LOCKBOX CODE47798 - KEY WILL GET YOU IN BOTH HOUSES COMMENTS AND NOTES