Loading...
APPROVED FM PLANSHarnett AMU HA C 0 U N T Y ---I— Application #-L�-- Date Received: Received BY: s k v Name of Project: Physical Address of Project: OEE,. Project Phone: Contact Person/Address WMIMMUT.. M. - Contractor's Namelinfo: 431 Jurwn-v- Rd.-/ Bid CCSO UNP-QUERGENCY SERVIC, ES Angier NC 27501 (-Rl 9 )-337 -9262 Collin D. Hurlev/Tvco Integrated Security 14001 Weston Pkwy. Ste. 102 Carv, NC 27513 collin.hurlev(ici.com Collin Q. Hurleyffyco Integrated Security 14001 Weston Pkwy. Ste. 102 Carv, NC 27513 • Plans that are submitted will be reviewed as quickly as possible with an average time of revi M• tween 7-10 working jgys. • Status checks may be conducted on plan reviews by visiting the websi - http://hteweb.hamett.org/Click2GovBP/Index.isp or by calling the Harnett County Central Permitti Office (910-893-7525, Option #2), or the Harnett County Fire Marshal's Office (910-893-7580). • Approved plans must be picked up from the Central Permitting Office and all fees paid before a required inspections can be conducted. Harnett A COUNTY III � 111111q�i; 1111 Application Number 1850043691 $200.00 ❑ Explosive Material (90 Days) $ - $100.00 ❑ Explosive Materials (72 Hours) $ - $100.00 ❑ Fireworks Public Display $ - $50.00 ❑ Final Inspection $ - $35.00 + $2.00 per device E Fire Alarm Testing $ 35.00 $35.00 + $2.00 per nozzle ❑ Fixed Fire Suppression $ - $75.00 ❑ Insecticide Fog/Fumigation $ - $100.00 ❑ Pipe Test/UST/AGST $ - $50.00 ❑ Plans up to 5000 sq ft $ - $100.00 ❑ Plans 5001 sq ft to 10,000 sq ft $ - $150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft $ - $250.00 ❑ Plans 25,001 sq ft and over $ - $35.00 + 2.00 per head ❑ Sprinkler Certification Test $ - $50.00 ❑ Standpipe Testing $ - $50.00 ❑ Special Assembly (ie. amusement buildings, carnivals, fairs) $ - $75.00 Tents/Canopies/Air Supported Structure $100.00 Tank Installation (charge for each tank) $100.00 ❑ Tank Removal (charge for each tank) $ - Total Devices/Heads $ - Total Cost $ 35.00 Code • i • 1 I Harnett COUNTY April 4, 2018 Collin Hurley Tyco Integrated Sec. 14001 Weston Parkway Suite 102 Cary, NC. 27513 Re: Absolute Care Assisted Living 431 Junny Road Angier, NC 27501 Application Number 18-50043691 Mr. Hurley, Thank you for submitting the fire alarm replacement paperwork. The request for change has been carefully reviewed by a qualified code enforcement official to examine for compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that need to be addressed before a final inspection of the new panel can be given. These items are outlined and described below. ® Fire Alarm System Upgrade Notes All items in notes are to be completed at the time of final o Provide a record of completion. o The Fire marshal's office will complete an acceptance test at completion of project. o Provide a copy of account history after the acceptance test is completed and approve. o Provide an accurate zone map at the FACP and remote annunciator panel. o All work/installation shall be compliant with the NCSFC and NFPA 72. o Call Fire Marshal's office to schedule the fire alarm acceptance test. (910-893-0743) Thank you again for submitting the fire alarm panel upgrade. Please review and adhere to any notes. These remarks are for the paperwork that was submitted and its original Harnett t intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office. Again, thank you and we look forward to working with you during the construction period! Sincerel 7 - odney Dan' s Fire Marsha Office of Box 370 Lillington, (910)-893-7580 Business Name: ABSOLUTE CARE ASSISTED LIVING BLDG 4 Address:1 BLDG 4 ANGIER, NC 27501 Phone: OFFC 919-639-6322 The following permit has been issued: Issued Date: 04/04/2018 Effective Date: 04/04/2018 Expiration Date: 10/04/2018 This permit certificate has been issued for [ construction / [ ] operational purposes located at the above business location. This permit has been issued and will be enforced in accordance with section 105 of the N.C. State Fire Prevention Code. Please contact our office for any further questions regarding this permit. I11bjJUULVI: MUMMY MUILII UdIIIUM UdLu 04/04/2018 Page 1 Tyco Integrated Security tq���� ��zw�nm�* xvr��meme�zmeuurity Suite 102 Cary, NC 27513 rp/. (919) 337-9262 Fax: w19) 337-9310 °°°*o",mm Attn: Rodney Daniels Harnett County 108 E, Front St, Lillington, NC 27546 RE: Like for like fire alarm system replacement at Absolute Care Assisted Living. Mr. Daniels, Please find enclosed the cut heet and calculations for the replacement of the fire alarm system in Building 4 of Absolute Care Assisted Living, located 431]unnyRd. inAngier. Per our conversation wewill replace the panel and each smoke detector one for one, like for like. VVewill provide anaddressable module atthe existing duct detector and pull stations. Please note that the intention offunctionality ufthe system asit iswas originally designed and installed will not change asaresult mfthis conversion. This conversion is required because the existing system is nonfunctional due to the building sustaining water damage several years back. The facility isnow making the necessary repairs tothe building to make ithabitable again. Designed to integrate seamlessly wittl CCTV, access control and Honeywell's full range of fire and burglary components, the new VISTA-250FBP provides the ultimate protection of life and properly. The UL Listed commercial fire and burglary control panel supports up to eight partitions and up to 250 zones/points using hardwired, wireless and V -Plexi • Comes standard with eight hardwired zones, expandable to 242 V-Plex addressable points"zones or 250 wireless Do;nts/zones • Can control eight separate areas independently (eight partitions) • Supports commercial wireless fire and burglary devices • Stores up to 1,000 events a Supports V-Plex addressable VistaKey access control (up to 15 doors) • Accommodates i 50 user codes and up to 500 access card holders using VistaKey • Two on -board notification (bell) circuits delivering 2,3A @ 12V or 3AA Ca) 24V • Automatic smoke detector sensitivity maintenance testing addressable technologies. A diverse line of Honeywell initiating devices, notification circuits, communication devices, keypads, RE receivers and relays are also supported. The VIS TA-250FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. • Four -wire smoke reset using onboard J2 output trigger • Supports Dynamic Signaling for AlarmNet communicators used in conjunction Min the phone line • Supports remote control via Alarr-nNet Total Connect Services' a Supports Internet AJarrr, Reporting* • Notification Appliance C,rcuits (two - Programmable - Individually s4enceable • Programmable on -board auxiliary relay • False alarm reduction features: - Exit error logic - Exit delay reset - Cross zoning - Call waiting defeat - Recent close report • Hardwired zones: - Provides eight style B hardwired zones - Supports N.O. or N.C. sensors - Individually assignable to any partition - Up to 32 two -wire smoke detectors each on zones one and two (64 total) - Up to 50 two -wire glassbreak detectors on zone eight - EOLR supervised for Fire and UL burglary installat,ons • Listed to ULB64 9th Edition • Upload/download via Ethernet* • Carbon Monoxide (CO) zone support • Patented addressable polling loop technology - Supports 242 two -wire zone points - Global polling technology for faster processing - Supervised by panel - Zones individually assignable to partitions, notification circuit (bell", output or auxiliary relay - 4,000 ft. capability without the use of shielded cable - Extender/Isolation bus modules - Eight zone - Class A and B expander module - Eight zone - Class B expander module - One zone supervised contact monitor module • UL Listed wireless expansion - Supports up to 250 wireless zones,/Points - Supervised by control for check-in signals - Tamper protection to, transmitters - Individually assignable up to eight partitions • Access Control Integration - Full integration with PassPoint Access Control System Up to '5 doors using VistaKey Access Control • Event reporting • Local printer of access or VISTA related events Communication - Phone mapping by zone response type - Panel operation during download Supported by a diverse line of Honeywell initiating devices, the VISTA-250FBP is the ideal integrated fire and burglary control for applications where a high level of security is necessary. Some examples of applications include: medical and professional buildings, supermarkets, churches, synagogues, schools, universities, strip malls, factories, warehouses, and larger residences. SPECIFICATIONS Electrical • Primary power: 18VAC @ 72VA ADEMCO No. 1451 • Control Panel quiescent current draw: 300mA • Backup battery: - 12VDC, 12AH min to 34AAH max - Lead acid battery (gel type) • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 23A @ 12V • Aux, standby pwr: 12VDC, 1A max • Total power: 2.3A at 12VDC, 3.4A a, 24VDC from all sources • Standby time: 24 hours with 1 A standby load using 34AAH battery • Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC, circuit protectors. All outputs are power limited • Optional 24 -volt power supply, PS 24 supplies two 24 VFW, 1.7A full wave rectified, unfiltered outputs Main Dialer • Line seize: Double Pole • Ringer equiv.: 0.78 • Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics • Dual phone line capability (using 5140DLM module) Cabinet Dimensions * 18° H X 14,5': W X 43" D Environmental • Storage temp: 14° F to 158° F (-10° C to 70° C) • Operating temp: 32° F to 122° F (0° C to 50' Q • Humidity: 85% PH • EMI: Meets or exceeds the following requirernents: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive A Agency Listings • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vaul'. • UL61 1 /16'1 0 Grades A, AA, Central Station • UI -365 Grades A, AA Police Connect • UL864/NFPA72 Local, Central Station and Remote Station • UL985 • Factory Mutual • California State Fire Marshal • MEA • CAN//ULC 5304 - Central and Monitoring Station Burglar Alarm Unit • CAN/ULC 5527 - Central Unit for Fire Alarm Systems • CAN/ULC 5303 - Local Burglar Alarm Unit • CAN/ULC 5525 - Audible Signal Appliances X*1 NIVA 1404 A *I aW40W Auxiliary Devices * 4204 - Relay Module, four form C contacts * 4204CF - Two supervised output circuits * 5881 Series RF receiver * 5883H RF receiver * 62205 - System printer used with 41 OOSM serial module * 6160CR-2 - Red Fire Keypad * 6160 - Burglary Keypad Two -Wire Smoke Detectors Conventional • System Sensor • ESL • DSC Horn/Strobes • System Sensor • Wheelock * Gentex Manual Pull Stations e 5140MPS-1 a 5140MPS-2 V-Plex (Addressable) Zone Expanders a 4101 SN Single Relay.17one Module Product specifications subject to change. • 4190SN Remote Point Module - two zones • 4193SN Two Zone Serial Interface Module • 4208SNF Class A/B Expander Module • 4208U Loop Expansion Module - eight zones • 4293SN One Zone Serial Interface Module V-Plex Extender/isolation Modules * 4297 Extender-Ilsolator Moaule * VSI Isolator Module V-Plex Smoke Detectors • 5193SD • 5193SDT V-Plex Passive Infrared Detectors 0 998MX eIS2500SN * DT7500SN V-Plex (Addressable) Contacts • 4939SN-WH • 4944SN-WH * 4959SN V-Plex Glassbreak Detectors a PG1625SN Optional 24V Power Supply - PS24 - 24V power supply - 3AA Commercial Wireless Devices • 5808W3 - Photoelectric Smoke/Heal, Detector • 5806W3 - Photoelectric Smoke Detector * 5809 - Wireless Heat Detector * 5817CB - Wireless Commercial Transmitter * 5869 - Hold up Transmitter * 5881 ENHC - RIF Receiver * 5883H - RIF Receiver Access Control • VistaKey V-Plex (addressabley Access Control • VistaKey-SK Starter Kit • VistaKey-EX Expansion K0, Alarm Communications • 7845i -ENT - Internet/Intranet Communicator • 7845GSM - Digital Cellular Communicator • 7845i -GSM - Internet and Digital Cellular Communicator • GSMCF/iGSMCF - Commercial Fire Communication Kits (when available) ORDERING V25OFSP-9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V25OFSP9-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model For more information: www.honeywell.com.1'security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Honeywell Melville, NY 11747 L'VS 'A2 KFBPv-u, 1.800.467.5875 SePte-,be, 2009 www,honeywell.coni 0 2009 11 ie,,w,onal Inc WOA 0100CR 2 COMMERCIAL FIRE ALPHA KEYPAD UL864 REV 9 LISTED The 6160CR-2 is an addressable remote keypad intended is backlit only when a key is depressed-, or when thie for use in commercial fire applications with Honeywell's system is in alarm or trouble condition. commercial fire control panels, The keys are continuously 'Ncte: The LCD may us )cxjram­ed to re,-nav, on at all wres (see panel backlit for convenience and easy visibility, The LCD display s'tfl'-"Mris for qwaAS), • Four programmable function keys • Built-in sounder • Seven Status LEDs - Armed (Red) - Ready (Green) - Power (Green) - Fire Alarm (Red) - Silenced (Yellow) - Supervisory (Yellow) - Trouble (Yellow) Sounder * High-quality speaker Electrical • 45r-nA standby 160mA in alarm (sounder, back light and LED on) ORDERING 6160CR-2 Commercial Fire Alpha Keypad For more information: wvNq.honevwell.comv'security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr, Suite 100 Melville, NY 11747 1.800A67.5875 www.honeywell.corn • Large easy-fo-read display • Red removable door • Physical 5.250" W x 7.437" H x 1.312" D Compatibility • Supports Control Panels - VISTA-32FB Rev 5 and higher - VISTA- 1 28FBP Rev 4 and higher - VISTA-250FBP Rev 4 and higher UL CUL and residential Listed for comvniercol lire arid ourglary rstallat mss. ro be employed win manufacturer s listed con un -,s as indicated i,, ihe- installation instructions. Product specifications subject to change. LiE, 160CR2 (1, C Se' tmbe, 2CC9 C 2009, 5193 Series V-PLEX`ADDRESSABLE SMOKE DETECTOR Honey -well Honeywell's V-Plex Addressable Photoelectric Smoke Detectors are designed to provide open area protection and to be used with compatible UL or JLC -listed Honeyvvell control panels that support V -Plea technology. The detectors incorporate a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to the presence of contaminates settling into the unit's chamber. The 15 1 93SDT/A also features a restorable, built-in, fixed temperature (135'F/57.2°C) thermal detector. FEATURES 9 Easy Installation: Installation is simplified by the use of a mounting base that may be pre -wired to the system, allowing the detector to be easily installed or removed for maintenance or service. (See Figure 1 J. LED Status Indicators: Two LEDs (green and red) provide local visual indication of the detector's status - including normal operation, alarm, out of sensitivity and trouble conditions, e Test button: This button allows the user to perform periodic testing or the detector's circuitry and verify that the detector is within the sensitivity lirnits, Versatile Mounting: Mounting is made simple with the included hardware and the large mounting ports, which accommodate drywall anchors for easy surface mounting, tSee FiQUre 1). Tamper Protection and Tamper Resistance: The detector contains a built-in tamper switch that can communicate back to the control panel in the event the detector is removed from its base. For an added level of security, the detector also ;includes a tamper resistant element that prevents removal from the base without the use of tools, (See Figure 1). DRE TMOUNI HOLES _N SNAPOFF D ORTAMPEF TAMPER RELEASE TAB Figure 1: Tamper -Resistant Feature/Wiring SPECIFICATIONS • Heat Sensor: (Model 5193SDT/A): 135'F (572'Q; Fixed Temperature Electronic Thermistors • Operating Ambient Temperature Range: 32' to 100'F (0' to 38'C) • Operating Humidity Range: 0 to 95% RH non -condensing • Storage Temperature Range- -4' to 158'F (-20' to 70'C) ACCESSORY(sold separately) • Diameter (including base): 5.3 inches (13.46 cm) • Height (including base): 2.0 inches (5.08 cm) • Weight: 6.3 oz. 0 78,6 g) • Agency Listing: UL 268; CAN/ULC 5531 • System Voltage Range: 7-14V • Standby Current (maximum 0 121fj LED off: 1.2mA LED on: 2.8mA To measure the detector's sensitivity, the SEMS-RDR Infrared Sensitivity Reader tool (sold separately) should be used. It reduces testing time, simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SEMS-RDR eliminates the need for magnets, voltmeters and ladders. 9EMZIU�... � MINIM Addremble Photoelectric Smoke Detector 51 OT Addressable Photoelectric Smoke Detector with Integral Heat Sensor 51 DTA Addressable Photoelectric Smoke Detector with Integral Heat Sensor (Canada Only) Accessory sold separately: SENS-ROR Handheld Sensitivity Reader Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Honeywell Melville, NY 11747 1,800.46T5875 L'tiA93GDTJ) ,unc, 201b www.honeywell.com i, 2o, 5 i,°emus mai Inc SYSTEM ISENSOR" 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer a low-cost means for property protection againstfire, and for non -life -safety installations where smoke detectors are inappropriate. I • Mullinle configurations for installations - Single- and dual -circuit models - Fixed temp and corribinazi on tixed- remp/tate-rpt-r4se 135°F or 194°F ratings. • Plain housing for residential installations (Ci ooel 5601P) • Easy-tia-ise termFral scews • A broad range of back box mounting Options I g E, - Single gang - 3,5'and 4-0clacional - 4- square with square to round plaster ring • Reversinle mount1rig bracket APPROVED ULC 5621. Multiple configurations. The 5600 series offers a fiJklinc of configurations to accommodate a broad range of applications. Both single- and dual -circuit models are available for low- and high- temperature ratings with, either fixed temperature or combination fixed temperaturelr?te-o#-rise (R -OR) activation. The ROR element of `he fixed/RJR models is restorable to accommodate field-tesirrig. Installation flexibility lb satilsfv a variety of installation needs. the 5600 series easily rnounts to single -gang and octagonal back boxes. And these models accommodate lour' -square back boxes when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface- Brunt back box Visual identification. The 5600 series provides clear markings �)n t exterior of the unit to ensure that tire proper detectors being used. Alphanumeric characters identify the activation method as well as the temperature rating in Fahrenheit and Celsius degrees. Fixed temperature mocels are identified FX while combination fixed/ rate -of -rise units are rnarked FX/R0R. The 561,Yj series also provides a post -activation indicator in the form of a collector, When the oetector is activated. the collector drops from the unit. making ', easy tr) ideritity the unit in alarm. Mechanical heat detector shall be a System, Sensor 5600 series i nodel number. listed to Underwnters Laboratories UI 521 'or Heat Detectors for Fire Protective Signaling Systefris, The detector shall be either a single -circuit or a dual-ciro,"it type, normally open. Tine detector shall be rated for activation a, either 135'P (571C) or 294°F (90'0), and shall activate by means of a fixed temperature thermal sensor, or a corribination fixed :ern peralu re(rate-cf-ri se thermal sensor. The rate -of -rase element, shall be activated by a rapid rise in temperature. approxinlaiply 15-F (8" YC) per Fninute. The detector shall include a reversible- mounting bracket for mounting to 3T./.-frich and 4 -inch octagonal, single gang, and 4 -inch square back coxes with a square to round plaster ringftrng connections shall be maae oy means of SEMS screws chat shall accommodate 14-22AWG wire. The detector shall contain alphanumeric marikinas on the exterior of the nousing to dentify its toMperatUre rating and activation Method. The rate -of -rise, element of conihination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Maximum Installation Temperature 5601P, 5603, 5621, and 5623 100"F (36"C? 5602, 5604. 5622. and 5624 150-'F (65"6'C) Operating Humidity Range 5 to 95% RH non -condensing Dimensions with mounting bracket -TTameier: 4-57 inches (1 Height, 1.69 inches (43Crn) Alarm Temperature 5601P 5603. 5621. and 5623 135'F (57T) 5602, 5604, 5622, and 5624 194'F (9f)'C1 Weight 6 oz. (`70 grarris5 Rate -of- Rise Threshold i5'F (8.3'C) rise per minutes (models 5601PI 5602,5621 and 5622only) Mounting 31 -inch octagonal back box 4 -inch octagonal back box Single gang back box 4 -inch square back box with a square to round plaster ring Operating Voltage / Contact 6-121)VAC / 3A Ratings 6-28VDr- / 1A 125VDC 10.3A 25OVDC 0.1A InputTerimnMix 14-22 AWG \A 0 C) Z 5601 P 5602,5622 5603,5623 5604,5624 5621 5602 Single LeTrPnug 194"F (90'C) Fixed Terriperature / nate-of-Rise 50 feet x 50 feet k 15 241n x 152m) 5603 Single Lettering I35 -F (57-0) Fixed Temperature 25 fee, x 25 feet (7.62rn )< 7.62m� 5604 Single Lettering 194'F (90°C) Fixed Temperature 25 feet x 25 feet (7,62rri x 7,62mj 56211 Dual Lettering 135-F (57-C) Fixed Temperature / Rate -of -Rise 5-0 feet Y, 510 feet (1 5,24m x 15.2m) 5622 Deal Lelering 194°F (``C; Fixed Temperature/ Rate-ot-Rise 50 feet x 51, feel (15.24m x I 5.2m, 5623 Dual Leftering 135 f -(117-'C' F-rxi-d lemperature 25 feel x 25 feet (7,62in x 7,62m) 5624 ',)(jai Lettering I �,,WF (9WC) Fixen lempecature., 25 lee! x 25 feet (17.62rn x 7.62m) "NOTE Refer to NFPA72 guidelines for spacing reductions M -len cellirg heights exceed 1() feel, 3825 Ohio Avenue # S-. Cnarles, IL 60174 -4WSTEM Pno,-e 800-SFNSORFax (330-377-6491-5 SENSOR- www, sy sl erli sensor Cor"` 794 =4 The ADEMCO 4193SN is a serialized two -zone expander used to connect alarm sensing devices to controls that support serial number polling loop devices (i.e., Vista - 40, Vista -50P, and Vista -100). Voltage: 8-12VDC (as supplied from the ADEMCO control panel for multiplex polling loop) RED (+) a . POLLING I LOOP I GREEN (LOOP 2) uNSUPERVISED BLACK (—) I I BLACK (COMMON) /Q � I WIRING DIAGRAM U-1 C L us LISTED S789 For Fire Applications: The ADEIVICO 4193SN must be mounted inside the control panel cabinet or inside a UL Listed junction box. Loop I must be used in the supervised configuration for Fire. Loop 2 may be used for Burglary. For UL Burglary Applications: If using an unsupervised zone of the ADEMCO 4193SN, the unit must be mount within 3 -feet of the alarm initiating device, with no intervening barriers. I NARNETT COUNTY CASH RECEIPTS *** CUSTOMER RECEIPT *** Oper: TBROCK Type: CP Drawer: 1 Date: 4/85/18 52 Receipt no: 310537 Year Number Amount 2016 50843641 431 TUNNY RD ANGIER, NC 27501 B5 BP — FIRE MARSHAL FEE$35,88 FM FEES TYCO INTEGRATED SECURITY Tender detail CP CREDIT CARD $35.00 35.00 Total tendered Total payment $35.60 Trans date: 4/05/18 Time: 15:05:24 ** THANK YOU FOR YOUR PAYMENT **