Loading...
CO aaitit.S. �;/^,,�,y liaL1Lr� �y�;'f� � A. //,,�y y��,;� //�,,y ' IMIE�I' ' lc � � �� ' �'®N1+1 QMIRSS, S4 COUNTY OF HARNETT Building Inspections Department Planning Services Certificate of Compliance: Occupancy: / Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances. This certifies at the time of issuance,this structure was in compliance with the venous ordinances of the County of Harnett and the North Carolina State Building Codes For the following: il Use Classification: S ) Permit Numbers Name: /YO(pf otn.s L/ ( Building: - Electrical: 4 Address:�/� cell Co/ Sr (/r Di Insulation: �0 3� Plumbing: Mechanical: G' ., MFG Home: O Date: - �— Building Official: �„e7 �/v PREPARED 2/27/18, 14 :14:02 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 2/28/18 e l ADDRESS . : 42 SCHOOL SIDE DR SUBDIV: ACADEMY@ACC PH 7 50LOTS CONTRACTOR : GML DEVELOPMENT INC PHONE : (919) 793-5237 OWNER . . : MCKEE HOME LLC PHONE : (910) 475-7100 PARCEL . . : 01-0535-25- -0100- -09- APPL NUMBER: 17-50040670 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 02/01/2017 11:13 AM JBROCK ---- ANDERSON CREEK ACADEMY #1067 - 42 SCHOOL SIDE DR STRUCTURE: 000 000 40.8X58.6 3BDR CRAWL W/ GARAGE & COV FLOOD ZONE • FLOOD ZONE X # BEDROOMS ' 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' ' SEWER WATER SUPPLY COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8101 01 2/14/17 MR R*BLDG FOOTING / TEMP SVC POLE VRU #: 002932671 2/14/17 AP T/S: 02/14/2017 02:20 PM MREARIC B103 01 3/09/17 TI R*BLDG FOUND & TEMP SVC POLE VRU #: 002942472 3/08/17 CA B103 02 3/10/17 JH R*BLDG FOUND & TEMP SVC POLE VRU #: 002942480 3/10/17 CA PER SHANE B103 03 3/16/17 JH R*BLDG FOUND & TEMP SVC POLE VRU #: 002945194 3/16/17 DA 1)Remove dirt from footing for inspection.2)Right side of garage missing projection. B104 01 3/22/17 JR R*FOUND & SETBACK VERIF SURVEY TIME: 17:00 VRU #: 002948073 3/22/17 AP T/S: 03/22/2017 10:11 AM JBROCK A814 01 3/23/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002948065 3/23/17 AP 42 SCHOOLL SIDE DR SPRING LAKE 28390 T/S: 03/23/2017 10:48 AM SBENNETT B103 04 3/23/17 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002948305 3/23/17 DA T/S: 03/22/2017 03:14 PM JBROCK Missng projection on right side of garage near wing wall.- B103 05 3/27/17 DT R*ELDG FOUND & TEMP SVC POLE VRU #: 002949196 3/27/17 AP T/S: 03/27/2017 02:54 PM DETAYLOR B105 01 4/10/17 JH R*OPEN FLOOR VRU #: 002956209 4/10/17 AP R425 01 5/11/17 JH FOUR TRADE ROUGH IN VRU #: 002970838 5/11/17 DP 1)Bolt 4 ply lvls in garage per plans every 16" .2)Replace over notched studs to left of panel in garage.3)Kinked duct in spare bath over tub for vent in bathroom .4)Fire caulk top of fire box chase.5)Replace all short nails in truss hangers with correct size nails & missing nails in some hangers throughout house.6)Install front & back porch post per plans.7) Plans show 2ply lvls accross front porch end to end.8)Need letter for holes drilled in lvls on front porh & in dining room.9)Need to strap each end of 2ply lvls in front left bedroom.10)Nail osb on end wall in back right bedroom.11)Dryer duct not labeled correctly should be 24 ' .12)Nail all 2 & 3 ply trusses per truss documents.l3)Need receptacle on back of house per code.14)10 psi on gas line. OK TO SIDE DO NOT INSULATE R425 02 5/16/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002972032 CONTINUED ONTO NEXT PAGE iBEPARED 2/27/18, 14:14:02 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 2/28/18 7 ADDRESS . : 42 SCHOOL SIDE DR SUBDIV: ACADEMY@ACC PH 7 50LOTS CONTRACTOR : GML DEVELOPMENT INC PHONE : (919) 793-5237 OWNER . . : MCKEE HOME LLC PHONE : (910) 475-7100 PARCEL . : 01-0535-25- -0100- -09- APPL NUMBER: 17-50040670 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 5/17/17 AP T/S: 05/12/2017 12:16 PM LBENNETT T/S: 05/15/2017 09:21 AM LBENNETT T/S: May 17, 2017 03:21 PM BSUTTON signed off for jimmy I129 01 5/18/17 JH R*INSULATION INSPECTION VRU #: 002974202 5/18/17 AP R125 01 5/23/17 JH ONE TRADE ROUGH IN VRU #: 002975571 5/23/17 AP Stone flashing M305 01 6/06/17 JH R*PLUMB SEWER CONNECTION TIME: 17:00 VRU #: 002980845 6/06/17 AP T/S: 06/05/2017 02:51 PM HPETRICH P307 01 6/06/17 JH R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 002980852 6/06/17 AP T/S: 06/05/2017 02:51 PM HPETRICH E209 01 6/26/17 JH R*ELEC TEMP POWER CERT VRU #: 002988970 6/26/17 AP R429 01 7/26/17 JH FOUR TRADE FINAL VRU #: 003003456 7/26/17 DP Door code to all doors 4292 Front & garage steps are more than 3/8" difference.2QMissing weatherstrip on exterior doors.X Replace broken window latches Support handrail to 3rd floor per code.S)Missing insualtionOOin ceiling.O0Need vent well on vent 4" from grade to bottom & same with crawl door4rNeed 3' landing as wide as the stairs at bottom for back deckAgiBrace & bolt back deck per code J4Missing 6 mill poly in crawl per code. R429 02 2/27/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003094562 2/27/18 DA T/S: 02/26/2018 11:08 AM LLUCAS T/S: 02/26/2018 11:08 AM LLUCAS HOUSE LOCKED T/S: 02/27/2018 01:55 PM LLUCAS T/S: 02/27/2018 01:55 PM LLUCAS R429 03 2/'2G8/r18XN T /� , FOUR TRADE FINAL TIME: 17:00 VRU #: 003095312 - j W * OVERRIDE TAKEN BY LLUCAS DATE: 02/27/18 TIME: 14:09:05 T/S: 02/27/2018 02:09 PM LLUCAS COMMENTS AND NOTES