01 Use Classification: Permit Numbers
Name: 73:1( ( o/ Ac 1 gt is L 6 ( Building: /�
Electrical:
Address: � �W �� S /4. i/ Insulation: a
�Q
Plumbing a
Mechanical:
f'
'4
dr MFG Home: o
Date: a- )S• Building Official: 6 ,4 ��
ig
// Ei
PREPARED 2/14/18, 14:12:45 INSPECTION TICKET PAGE 4
Hafnett-., ounty INSPECTOR: IVR DATE 2/15/18
ADDRESS . : 542 NEW CASTLE LN SUBDIV: HIGHGROVE@ANDERSON CRK 6B 39L0
CONTRACTOR : BILL CLARK HOMES LLC PHONE : (252) 355-5805
OWNER . . : BILL CLARK HOMES LLC PHONE :
PARCEL . . : 01-0504-02- -0177- -54-
APPL NUMBER: 16-50039802 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : 542 NEW CASTLE/ HIGHGROVE LOT210
STRUCTURE: 000 000 47E60 4 BDR SLAB il/ GARAGE & BONUS N/CL
FLOOD ZONE FLOOD ZONE X
# BATHS • 2 # BEDROOMS • 4.00
PROPOSED USE SFD SEPTIC - EXISTING? ' SEWER
WATER SUPPLY • COUNTY
PERMIT: CPS' 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 11/15/16 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 002897388
11/15/16 AP T/S: 11/14/2016 08:32 AM LBENNETT
T-POLE PASSED NO PERMIT CLFD IN BOX
A814 01 1/25/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002923795
1/25/17 AP 542 NEW CASTLE LN SPRING LAKE 28390
T/S: 01/25/2017 08:35 AM SBENNETT
B103 01 1/25/17 MR R+BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002923787
1/25/17 AP T/S: 01/24/2017 09:36 AM LBENNETT
T/S: 01/25/2017 01:26 PM MREARIC
P309 01 2/21/17 JH R*PLUMB UNDER SLAB TIME: 17:00 VRU #: 002935245
2/21/17 AP T/S: 02/17/2017 04:10 PM LBENNETT
B111 01 2/24/17 JH R*BLDG SLAB INSP/TEMP SVC POLE TIME: 17:00 VRU #: 002937118
2/24/17 AP T/S: 02/23/2017 11:43 AM LBENNETT
B104 01 4/03/17 LB R*FOUND & SETBACK VERIF SURVEY TIME: 17:00 VRU #: 002953727
4/03/17 AP T/S: 04/03/2017 10:22 AM LBENNETT
T/S: 04/03/2017 10:23 AM LBENNETT
R425 01 4/04/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU 4: 002953735
4/04/17 DA T/S: 04/03/2017 10:23 AM LBENNETT
1)Block osb joints at each end of garage door
header.2)Nail loose osb on back wall in closet at half
bath.3)Missing anchor bolts throughout house per
code.4)Replace all bent nails on floor truss hangers & nail
all holes in floor truss hangers.5)Nail loose osb in left
front corner of dining room.6)Need hurricane straps on El &
Ela in hall & back bedroom per truss documents.7)Nail
hurriacne straps on 2ply truss in front bedroom.
R425 02 4/06/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002955045
4/06/17 AP T/S: 04/05/2017 09:25 AM LBENNETT
1129 01 4/12/17 JH R*INSULATION INSPECTION TIME: 17:00 VRU #: 002957793
4/12/17 AP T/S: 04/11/2017 02:11 PM LBENNETT
P307 01 5/04/17 JH R+PLUMB WATER CONNECTION TIME: 17:00 VRU #: 002967826
5/04/17 DA T/S: 05/03/2017 11:23 AM LBENNETT
WAter lines need a cutoff valve 12^ meter & need to be
connected at meter.
T/S: 05/05/2017 08:13 AM TJONES
CONTINUED ONTO NEXT PAGE
PREPARED) 2/14/18, 14:12:45 INSPECTION TICKET PAGE 5
Hafnett_$ounty INSPECTOR: IVR DATE 2/15/18
ADDRESS . : 542 NEW CASTLE LN SUBDIV: HIGHGROVE@ANDERSON CRK 6B 39L0
CONTRACTOR : BILL CLARK HOMES LLC PHONE : (252) 355-5805
OWNER . . : BILL CLARK HOMES LLC PHONE :
PARCEL . . : 01-0504-02- -0177- -54-
APPL NUMBER: 16-50039802 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/C0IM1ENTS
M305 01 5/09/17 JH R*PLUMB SEWER CONNECTION TIME: 17:00 VRU #: 002969285
5/09/17 AP T/S: 05/05/2017 04:58 PM JBROCK
P307 02 5/09/17 JH R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 002969293
5/09/17 AP T/S: 05/05/2017 04 :58 PM JBROCK
E209 01 7/27/17 JH R*ELEC TEMP POWER CERT VRU #: 003004377
7/27/17 DA 1)Need ladder for attic access.2)Label outside panel.
E209 02 7/28/17 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003005063
7/28/17 AP T/S: 07/27/2017 02 :31 PM BPETRICH
R429 01 8/21/17 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003015039
8/21/17 DA T/S: 08/18/2017 01:48 PM JBROCK
1)Missing safety latches on front windows down
stairs.2)Missing receptacle 2' from kitchen sink.3)Handrail
to low in stairway needs to be 34 - 38" .4)N0 INSULATION
IN ATTIC.5)Need a 24" walkway from attic access to
AHU.6) Insulate & weatherstrip attic access door per
code.7)AC pad needs to sit on grade.8)Need 6" in 10' grade
away from house per code.
R429 02 11/08/17 KS FOUR TRADE FINAL TIME: 17:00 VRU #: 003050648
11/08/17 DA T/S: 11/07/2017 10:52 AM DJOHNSON
h/S: 11/08/2017 01:08 PM KSLATTUM
house lockef
R429 03 1/31/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003082609
1/31/18 DP T/S: 01/30/2018 08:16 AM BPETRICH
Insulate attic access door per code #6
R429 04 2/15 18FOUR TRADE FINAL TIME: 17:00 VRU #: 003089398
.' T/S: 02/14/2018 11:22 AM BPETRICH
1� COMMENTS AND NOTES