CO ,
00, li, A, , , „
.4 COUNTY OF HARNETT
Building Inspections Department
Planning Servicesvii
Certificate of Compliance: Occupancy:
Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances4 .
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the
North Carolina State Building Codes.For the following:
Use Classifcation: C Permit Numbers
Name: JJd ,i On 51/& oele r L/7 Building: l�
4
Electrical: 6k r.
Address: /‘ ‘ Sal,/ 6 ,c‹,-,-/ Insulation: '.nd
en .7:5--1,,,
Mechanical:0
MFG Home:
Date: 01 - G -7/- Building Official: ,.n
. 'e
•PREPIIVED 2/05/18, 14:14:22 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 2/06/18
ADDRESS . : 166 SAW GRASS CT SUBDIV: WALNUT GROVE 37LOTS
CONTRACTOR : H & H ONSITE HOMES LLC PHONE : (910) 486-4864
OWNER . . : H & H ONSITE HOMES LLC PHONE :
PARCEL . . 01-0525- - -0062- -30-
APPL NUMBER: 16-50039681 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 09/08/2016 03 :43 PM JBROCK ----
WALNUT GROVE #21 - 166 SAW GRASS CT
STRUCTURE: 000 000 42.8X61 3BDR CRAWL W/ GARAGE
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS - 3000000.00 PROPOSED USE - SFD
SEPTIC - EXISTING' • NEW TANK WATER SUPPLY - COUNTY
PERMIT: CPSF 00 CP 4- SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
A814 01 8/02/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 003006947
8/02/17 AP 166 SAW GRASS CT BUNNLEVEL 28323
T/S: 08/02/2017 08:57 AM SBENNETT
B101 01 8/02/17 JLP R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 003006954
8/02/17 AP T/S: 08/01/2017 02:14 PM JBROCK
T/S: 08/02/2017 03:06 PM JPERRY
B103 01 8/21/17 JLP R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003014545
8/21/17 AP T/S: 08/17/2017 03:53 PM JBROCK
T/S: 08/21/2017 02:46 PM JPERRY
B105 01 8/25/17 JH R*OPEN FLOOR TIME: 17:00 VRU #: 003017191
8/25/17 DP T/S: 08/24/2017 12:18 PM DJOHNSON
OPEN FLOOR NOT STARTED
B105 02 8/30/17 JH R*OPEN FLOOR TIME: 17:00 VRU #: 003018983
8/30/17 DA T/S: 08/29/2017 02:25 PM JBROCK
1) I joist to left of front porch not bearing 1 3/4" .2)Nail
each side of bottom flange with 1 nail per side for I
joist.2)Need repair letter for damamged flange at double I
joist on back wall behind garage.
8105 03 9/05/17 JH R*OPEN FLOOR TIME: 17:00 VRU #: 003020922
9/05/17 AP T/S: 09/01/2017 02:30 PM BPETRICH
R425 01 10/09/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003035052
10/09/17 CA T/S: 10/05/2017 01:48 PM JBROCK
per carter
R425 02 10/11/17 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003036597
10/11/17 DA T/S: 10/09/2017 04:00 PM JBROCK
T/S: 10/11/2017 01:09 PM KSLATTUM
1. House wrap not complete on back an side of house. 2.
need uplift on trusses bearing on front porch wall 3. B03
girder truss insufficient uplift. 4 . drain test low 5,
fie caulk wire at back wall of garage sole plate. ok to
insulate
I129 01 10/16/17 JH R*INSULATION INSPECTION TIME: 17:00 VRU #: 003038783
10/16/17 AP T/S: 10/12/2017 02:17 PM LLUCAS
T/S: 10/12/2017 03:14 PM BPETRICH
R425 03 10/16/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003038791
10/16/17 AP T/S: 10/12/2017 02:17 PM LLUCAS
CONTINUED ONTO NEXT PAGE
:PREPAYED 2/05/18, 14 :14 :22 INSPECTION TICKET PAGE 2
Harriett County INSPECTOR: IVR DATE 2/06/18
ADDRESS . : 166 SAW GRASS CT SUBDIV: WALNUT GROVE 37LOTS
CONTRACTOR : H & H ONSITE HOMES LLC PHONE : (910) 486-4864
OWNER : H & H ONSITE HOMES LLC PHONE :
PARCEL . . : 01-0525- - -0062- -30-
APPL NUMBER: 16-50039681 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
T/S: 10/12/2017 03:14 PM BPETRICH
8111 01 10/25/17 OH R*BLDG SLAB INSP/TEMP SVC POLE TIME: 17:00 VRU #: 003043767
10/25/17 AP T/S: 10/24/2017 01:04 PM JBROCK
front porch inspection
waiting on sealed letter
H824 01 1/23/18 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003079795
1/23/18 AP T/S: 01/24/2018 09:51 AM KHINSON
T/S: 01/24/2018 09:51 AM KHINSON
R125 01 1/23/18 JH ONE TRADE ROUGH IN TIME: 17:00 VRU #: 003078318
1/23/18 AP T/S: 01/22/2018 10:55 AM JBROCK
STONE INSPECTION
P307 01 1/25/18 LL R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003080678
1/25/18 AP T/S: 01/25/2018 09:52 AM LLUCAS
T/S: 01/25/2018 09:52 AM LLUCAS
E209 01 1/26/18 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003080686
1/26/18 AP T/S: 01/25/2018 10:04 AM JBROCK
R429 01 2/02/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003084126
2/02/18 DA T/S: 02/01/2018 08:50 AM JHROCK
1)Window safety latches in front left bedroom.2)Vent wells
on back of house.3)Condesing unit not level.
R429 02 2/06/18 �IQ FOUR TRADE FINAL TIME: 17:00 VRU #: 003085271
0744-4. 4 [ T/S: 02/05/2018 09:17 AM BPETRICH
1 COMMENTS AND NOTES