CO italkittlagtalt hilaillattait4
COUNTY OF HARNETT
Building Inspections Department
Planning Services 6
Certificate of Compliance: Occupancy: /
Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances.
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the
North Carolina State Building Codes.For the following:
Use Classification: S `/�O Permit Numbers
Name: 5- c4 ' / /. n:Joint 7I1( Building: ��
Electrical: S.
Address: /J4 /J/Jruer C Insulation: 'c
"64,
Plumbing:
Mechanical: {
MFG Home: �S` 64
Date: — /� Building Official: , cz, �.,
PREPARED `■2/07/18, 14:05:03 INSPECTION TICKET PAGE 4
Harn@tt C±linty INSPECTOR: IVR DATE 2/08/18
ADDRESS . : 134 HUMVEE CT SUBDIV: PATTONS POINT PH 2 73LOTS
CONTRACTOR : BRADLEY BUILT INC PHONE (919) 639-2073
OWNER . . : STANCIL BUILDERS INC PHONE : (919) 639-2073
PARCEL . . : 03-9597- - -0225- -17-
APPL NUMBER: 16-50039225 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 07/15/2016 11:35 AM JBROCK ----
PATTONS POINT PH 2 #136
STRUCTURE: 000 000 42X39 3BDR CRAWL W/ GARAGE
FLOOD ZONE - FLOOD ZONE X
# BEDROOMS 3000000.00 PROPOSED USE SFD
SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • COUNTY
PERMIT: CPE' 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 12/08/16 MR R*BLDG FOOTING / TEMP SVC POLE VRU #: 002908027
12/08/16 AP T/S: 12/08/2016 11:55 AM MREARIC
B103 01 1/13/17 TSG R*BLDG FOUND & TEMP SVC POLE VRU #: 002919569
1/13/17 AP
A814 01 1/13/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002919578
1/13/17 AP 134 HUMVEE CT BROADWAY 27505
T/S: 01/13/2017 09:43 AM SBENNETT
B105 01 3/27/17 DT REOPEN FLOOR VRU #: 002949698
3/27/17 AP T/S: 03/27/2017 02:54 PM DETAYLOR
R425 01 5/11/17 DT FOUR TRADE ROUGH IN VRU #: 002970716
5/11/17 DA T/S: 05/11/2017 12:17 PM DETAYLOR
No plans, okay to side, plumbing good, fire block hvac
chase
R425 02 5/12/17 JH FOUR TRADE ROUGH IN VRU #: 002971494
5/12/17 DP 1)Missing nail guard at top plate on wires between windows
in kitchen on back wa11.2)22-16D nails each side of top
plate splice in kitchen & family room per plans.3)Missing
nail guard on 2" pipe @ bottom plate in master
clOset.4)Nail guards @ top plate in master closet & master
bath on plumbing need to be 2" below top plate per
code.5)Need carbon/smoke detector outside of master
bedroom door.6)Fire block the top of the chases in master
bathroom.7)Nail air barreirs & seal all cracks per
code.8)Missing nail guard on water line @ top plate to
right of master bedroom door.9)Blocking 4 ' from corners
laid down for support not nailer per code.l0)Winders do not
meet code 4" on small side & not more than 3/8" difference a
at 12" from small end.11)Sleeve & seal drain line at
foundation wall per code.12)Label dryer duct length per
code.l3)Remove sidding under fire box & front porch for
insulation inspection.
OK TO SIDE EVERYWHERE BUT FIRE BOX & FRONT PORCH
DO NOT INSULATE
H824 01 8/01/17 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003009461
8/01/17 AP T/S: 08/07/2017 02:09 PM KHINSON
T/S: 08/07/2017 02 :10 PM KHINSON
R425 03 8/08/17 JLP FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003009453
8/08/17 DA T/S: 08/07/2017 02:06 PM BPETRICH
1-Fire chaulk hole in upstairs bathroom floor. 2-Nail guard
CONTINUED ONTO NEXT PAGE
PREPARED `` 2/07/18, 14:05:03 INSPECTION TICKET PAGE 5
Harn4tt County INSPECTOR: IVR DATE 2/08/18
ADDRESS . : 134 HUMVEE CT SUBDIV: PATTONS POINT PH 2 73LOTS
CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639-2073
OWNER . . : STANCIL BUILDERS INC PHONE : (919) 639-2073
PARCEL . : 03-9597- - -0225- -17-
APPL NUMBER: 16-50039225 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
in master bathroom needs to be moved down. 3-Fire block
chase in master bath. 4-Frame stairs per code.
I129 01 9/06/17 JLP R'INSULATION INSPECTION VRU #: 003021296
9/06/17 AP T/S: 09/06/2017 03:28 PM JPERRY
R425 04 9/06/17 JLP FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003021680
9/06/17 AP T/S: 09/05/2017 03 :45 PM LLUCAS
T/S: 09/06/2017 03:28 PM JPERRY
E209 01 2/05/18 JH R'ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003085602
2/05/18 AP T/S: 02/05/2018 01:07 PM LLUCAS
�g T/S: 02/05/2018 01:07 PM LLUCAS
R429 01 2 T�IA FOUR TRADE FINAL TI9E: 00 VCU #: 003086592
rq9'�/ T/S: 02/07/2018 11:59 AM
BPETRICH
COMMENTS AND NOTES