Loading...
CO italkittlagtalt hilaillattait4 COUNTY OF HARNETT Building Inspections Department Planning Services 6 Certificate of Compliance: Occupancy: / Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances. This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes.For the following: Use Classification: S `/�O Permit Numbers Name: 5- c4 ' / /. n:Joint 7I1( Building: �� Electrical: S. Address: /J4 /J/Jruer C Insulation: 'c "64, Plumbing: Mechanical: { MFG Home: �S` 64 Date: — /� Building Official: , cz, �., PREPARED `■2/07/18, 14:05:03 INSPECTION TICKET PAGE 4 Harn@tt C±linty INSPECTOR: IVR DATE 2/08/18 ADDRESS . : 134 HUMVEE CT SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE (919) 639-2073 OWNER . . : STANCIL BUILDERS INC PHONE : (919) 639-2073 PARCEL . . : 03-9597- - -0225- -17- APPL NUMBER: 16-50039225 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 07/15/2016 11:35 AM JBROCK ---- PATTONS POINT PH 2 #136 STRUCTURE: 000 000 42X39 3BDR CRAWL W/ GARAGE FLOOD ZONE - FLOOD ZONE X # BEDROOMS 3000000.00 PROPOSED USE SFD SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • COUNTY PERMIT: CPE' 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 12/08/16 MR R*BLDG FOOTING / TEMP SVC POLE VRU #: 002908027 12/08/16 AP T/S: 12/08/2016 11:55 AM MREARIC B103 01 1/13/17 TSG R*BLDG FOUND & TEMP SVC POLE VRU #: 002919569 1/13/17 AP A814 01 1/13/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002919578 1/13/17 AP 134 HUMVEE CT BROADWAY 27505 T/S: 01/13/2017 09:43 AM SBENNETT B105 01 3/27/17 DT REOPEN FLOOR VRU #: 002949698 3/27/17 AP T/S: 03/27/2017 02:54 PM DETAYLOR R425 01 5/11/17 DT FOUR TRADE ROUGH IN VRU #: 002970716 5/11/17 DA T/S: 05/11/2017 12:17 PM DETAYLOR No plans, okay to side, plumbing good, fire block hvac chase R425 02 5/12/17 JH FOUR TRADE ROUGH IN VRU #: 002971494 5/12/17 DP 1)Missing nail guard at top plate on wires between windows in kitchen on back wa11.2)22-16D nails each side of top plate splice in kitchen & family room per plans.3)Missing nail guard on 2" pipe @ bottom plate in master clOset.4)Nail guards @ top plate in master closet & master bath on plumbing need to be 2" below top plate per code.5)Need carbon/smoke detector outside of master bedroom door.6)Fire block the top of the chases in master bathroom.7)Nail air barreirs & seal all cracks per code.8)Missing nail guard on water line @ top plate to right of master bedroom door.9)Blocking 4 ' from corners laid down for support not nailer per code.l0)Winders do not meet code 4" on small side & not more than 3/8" difference a at 12" from small end.11)Sleeve & seal drain line at foundation wall per code.12)Label dryer duct length per code.l3)Remove sidding under fire box & front porch for insulation inspection. OK TO SIDE EVERYWHERE BUT FIRE BOX & FRONT PORCH DO NOT INSULATE H824 01 8/01/17 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003009461 8/01/17 AP T/S: 08/07/2017 02:09 PM KHINSON T/S: 08/07/2017 02 :10 PM KHINSON R425 03 8/08/17 JLP FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003009453 8/08/17 DA T/S: 08/07/2017 02:06 PM BPETRICH 1-Fire chaulk hole in upstairs bathroom floor. 2-Nail guard CONTINUED ONTO NEXT PAGE PREPARED `` 2/07/18, 14:05:03 INSPECTION TICKET PAGE 5 Harn4tt County INSPECTOR: IVR DATE 2/08/18 ADDRESS . : 134 HUMVEE CT SUBDIV: PATTONS POINT PH 2 73LOTS CONTRACTOR : BRADLEY BUILT INC PHONE : (919) 639-2073 OWNER . . : STANCIL BUILDERS INC PHONE : (919) 639-2073 PARCEL . : 03-9597- - -0225- -17- APPL NUMBER: 16-50039225 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS in master bathroom needs to be moved down. 3-Fire block chase in master bath. 4-Frame stairs per code. I129 01 9/06/17 JLP R'INSULATION INSPECTION VRU #: 003021296 9/06/17 AP T/S: 09/06/2017 03:28 PM JPERRY R425 04 9/06/17 JLP FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003021680 9/06/17 AP T/S: 09/05/2017 03 :45 PM LLUCAS T/S: 09/06/2017 03:28 PM JPERRY E209 01 2/05/18 JH R'ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003085602 2/05/18 AP T/S: 02/05/2018 01:07 PM LLUCAS �g T/S: 02/05/2018 01:07 PM LLUCAS R429 01 2 T�IA FOUR TRADE FINAL TI9E: 00 VCU #: 003086592 rq9'�/ T/S: 02/07/2018 11:59 AM BPETRICH COMMENTS AND NOTES