Loading...
CO Op COUNTY OF HARNETTIN Building Inspections Department Planning Servicesfi44 Certificate of Compliance: Occupancy: V Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances. ii This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the North Carolina State Building Codes.For the following: Use Clap ijication: Permit Numbers Name: )tion r .Li.nmrt5 Building: // 4 74 Electrical: G S Address: td)(oi9 71 ( )/9 S Insulation: Plumbing: ,��- Mechanical: MFG Home: _ Date: _ ,) - Building Official: / / : P`tEPARED 2/19/18, 14:02:35 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 2/20/18 { ADDRESS 4260 NC 210 S SUBDIV: J G LAYTON ESTATE CONTRACTOR : SOUTH EASTERN GC INC PHONE : (910) 474-6778 OWNER . . : SUMMERS SHANE E & CHAUNTEL M PHONE : PARCEL . . : 12-0548- - -0016- -27- APPL NUMBER: 16-50038372 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 04/01/2016 11:36 AM DJOHNSON -- VANDERGRIFT FARM LOT 25 210 S ACROSS FROM VANDERCROFT FARMS. SITS ON THE RIGHT SIDE OF RD. T/S: 05/26/2017 12:19 PM BPETRICH -- ADDRESS IS 4260 NC 210 S ****PREMISE 21920475**** APPL NOTES : BPMN 6/20/17 T/S: 06/20/2017 01:40 PM BPETRICH -- BEAVER BROTHERS INC IS ONLY DOING RADIENT FLOOR PLUMBING WORK STRUCTURE: 000 000 90R48 5 BR 3 BA ATT GARAGE MONO SLAB FLOOD ZONE FLOOD ZONE X # BATHS • 3 # BEDROOMS • 5.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS A814 01 6/30/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002991891 7/03/17 AP 4260 NC 210 S BUNNLEVEL 28323 POST ADDRESS AT HWY T/S: 07/03/2017 10:41 AM SBENNETT P309 01 7/03/17 JLP R*PLUMB UNDER S1.LR TIME: 17:00 VRU #: 002991909 7/03/17 AP T/S: 06/29/2017 11:31 AM JBROCK lock boc code at the gate - 1981 T/S: 06/30/2017 08:24 AM DJOHNSON T/S: 07/03/2017 01:47 PM JPERRY No t-pole on site B114 01 7/11/17 JH R*BLDG MONO SLAB/TEMP SVC POLE TIME: 17:00 VRU #: 002995108 7/11/17 DA T/S: 07/10/2017 12 :16 PM DJOHNSON CUSTOMER IS ASKING FOR A SLAB INSPECTION, RADIANT HEAT UNDER SLAB INSPECTION. ***LOCK BOX CODE IS 1981*** 1)Res check has R 30 for ceiling it needs to be R38.2)Garage footing needs to be continuous across garage door per plan.3)Clean out loose dirt from bottom of footings.4)There are voids behind insulation that needs tobe addressed.5)Slab insulation needs to verticle & all the way against inside of footing per engineers detail. 8111 01 7/13/17 JH R*BLDG SS.LP INSP/TEMP SVC POLE TIME: 17:00 VRU 4: 002996577 7/13/17 AP T/S: 07/12/2017 01:57 PM BPETRICH RADIANT HEAT UNDER SLAB - ALSO PLEASE INSPECT TPOLE - PREMISE WILL BE WRITTEN ON PERMIT CARD T-POLE PASSED R425 01 10/09/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU if: 003035599 10/09/17 DP T/S: 10/06/2017 12:57 PM LLUCAS LOCK BOX CODE#1981 CONTINUED ONTO NEXT PAGE PREPARED 2/19/18, 14:02:35 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 2/20/18 t ADDRESS 4260 NC 210 S SUBDIV: J G LAYTON ESTATE CONTRACTOR : SOUTH EASTERN GC INC PHONE : (910) 474-6778 OWNER . . : SUMMERS SHANE E & CHAUNTEL M PHONE : PARCEL . . : 12-0548- - -0016- -27- APPL NUMBER: 16-50038372 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 1)Missing studs under top plate joints in garage on front wa11.2)Missing nails in roof truss hnagers to left of house/garage door.3)Missing anchor bolts each side of exterior doors.4)Missing nail guards & fire caulk on water lines in laundry room on garage wa11.5) 100 psi on water line test.6)Fasten all toilet flanges per code.7) Plans show ballon frame on walls in living room & dining room need engineer letter.8)Fill all holes under tubs & showers.9)Missing hurricane straps on walls in living & dining room.10)Missing baffels per code.11)Missing big window in living room.12)Strap all trunk line duct every 64" per code.13)Nail & seal all air barriers in chases.14)Missing air barrier over 2ply lvls in foyer.15)Nee Missing floor recepacle on open side of loft.16)Need full set of truss drawings & layout to finish inspection.17)Missing smoke detector outside of bed5.18)Nail house wrap 12"-18" each stud with 1" fastener per house wrap installtion instructions. DO NOT INSULATE OR SIDE R425 02 10/24/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003043130 10/24/17 DP T/S: 10/23/2017 01:01 PM LLUCAS ITEM 12 & 13 were not corrected I129 01 10/27/17 JH R*INSULATION INSPECTION VRU #: 003045259 10/27/17 AP R425 03 10/27/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003045705 10/27/17 AP T/S: 10/26/2017 02 :54 PM BPETRICH H824 01 12/04/17 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003062395 12/04/17 AP T/S: 12/05/2017 10:47 AM KHINSON T/S: 12/05/2017 10:47 AM KHINSON R125 01 12/29/17 JH ONE TRADE ROUGH IN TIME: 17:00 VRU #: 003070976 12/29/17 AP T/S: 12/22/2017 04 :14 PM JBROCK STONE PREP M305 01 1/24/18 JH R*PLUME SEWER CONNECTION TIME: 17:00 VRU #: 003079274 1/24/18 AP T/S: 01/23/2018 12:29 PM JBROCK P307 01 1/24/18 JH R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003079662 1/24/18 DA T/S: 01/24/2018 08:41 AM LLUCAS T/S: 01/24/2018 08:41 AM LLUCAS 1. WATER LINE NOT 12"DEEP 2. CUT OFF FOR WATERLINE NEEDS TO BE 12"FROM METER BOX OR LESS. P307 02 1/29/18 JH R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003081577 1/29/18 AP T/S: 01/26/2018 08:50 AM JBROCK E209 01 1/31/18 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003083508 1/31/18 DA T/S: 01/31/2018 09:18 AM LLUCAS T/S: 01/31/2018 09:19 AM LLUCAS CONTINUED ONTO NEXT PAGE Pj$PARED 2/19/18, 14:02:35 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 2/20/18 ADDRESS . : 4260 NC 210 S SUBDIV: J G LAYTON ESTATE CONTRACTOR : SOUTH EASTERN GC INC PHONE : (910) 474-6778 OWNER . . : SUMMERS SHANE E & CHAUNTEL M PHONE : PARCEL . : 12-0548- - -0016- -27- APPL NUMBER: 16-50038372 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 1. MISSING PANEL COVER IN GARAGE 2 .MISSING SMOKE DETECTOR OUTSIDE OF RIGHT BEDROOM 3 . MISSING METERBASE ON BACK OF HOUSE M409 01 1/31/18 JH R*GAS PIPING TIME: 17:00 VRU #: 003083052 1/31/18 AP T/S: 01/30/2018 01:06 PM JBROCK T/S: 01/31/2018 09:22 AM LLUCL5 E209 02 2/01/18 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003083888 2/01/18 DP T/S: 01/31/2018 01:52 PM BPETRICH CALL DREW AT 910.890.4370 AT LEAST AN HOUR BEFORE YOU GET THERE SO HE CAN MEET YOU WITH A LADDER FOR HVAC START UP 1)Panel cover in garage has hole inside panel.2)Need to label AHU in garage.3)Need ladder for AHU in attic. E209 03 2/02/18 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003084548 2/02/18 AP T/S: 02/01/2018 12:06 PM BPETRICH R429 01 2/12/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003087681 2/12/18 CA T/S: 02/08/2018 04:21 PM BPETRICH PER DREW R429 02 2/16/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003089828 2/16/18 DP T/S: 02/14/2018 04:38 PM DJOHNSON ,44-Fire caulk around pipe in garage ceiling at AHU.t)Need protection for the water lines in garage at slab.)lDead bolt for front door$1 Ladder for attic access.f)Energy certificate.)Missing sidding at meter & seal around meyter box.4ISeal post at stone work.8)House #s. R429 03 2/20/18 [� / FOUR TRADE FINAL TIME: 17:00 VRU #: 003090990 J•)(� /f T/S: 02/16/2018 02 :49 PM LLUCAS COMMENTS AND NOTES