CO Op
COUNTY OF HARNETTIN
Building Inspections Department
Planning Servicesfi44
Certificate of Compliance: Occupancy: V
Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances. ii
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the
North Carolina State Building Codes.For the following:
Use Clap ijication: Permit Numbers
Name: )tion r .Li.nmrt5 Building: // 4
74
Electrical: G S
Address: td)(oi9 71 ( )/9 S Insulation:
Plumbing: ,��-
Mechanical:
MFG Home: _
Date: _ ,) - Building Official: / / :
P`tEPARED 2/19/18, 14:02:35 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE 2/20/18
{
ADDRESS 4260 NC 210 S SUBDIV: J G LAYTON ESTATE
CONTRACTOR : SOUTH EASTERN GC INC PHONE : (910) 474-6778
OWNER . . : SUMMERS SHANE E & CHAUNTEL M PHONE :
PARCEL . . : 12-0548- - -0016- -27-
APPL NUMBER: 16-50038372 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 04/01/2016 11:36 AM DJOHNSON --
VANDERGRIFT FARM LOT 25
210 S ACROSS FROM VANDERCROFT FARMS.
SITS ON THE RIGHT SIDE OF RD.
T/S: 05/26/2017 12:19 PM BPETRICH --
ADDRESS IS 4260 NC 210 S
****PREMISE 21920475****
APPL NOTES : BPMN 6/20/17 T/S: 06/20/2017 01:40 PM BPETRICH --
BEAVER BROTHERS INC IS ONLY DOING
RADIENT FLOOR PLUMBING WORK
STRUCTURE: 000 000 90R48 5 BR 3 BA ATT GARAGE MONO SLAB
FLOOD ZONE FLOOD ZONE X
# BATHS • 3 # BEDROOMS • 5.00
PROPOSED USE • SFD SEPTIC - EXISTING' • NEW TANK
WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
A814 01 6/30/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002991891
7/03/17 AP 4260 NC 210 S BUNNLEVEL 28323
POST ADDRESS AT HWY
T/S: 07/03/2017 10:41 AM SBENNETT
P309 01 7/03/17 JLP R*PLUMB UNDER S1.LR TIME: 17:00 VRU #: 002991909
7/03/17 AP T/S: 06/29/2017 11:31 AM JBROCK
lock boc code at the gate - 1981
T/S: 06/30/2017 08:24 AM DJOHNSON
T/S: 07/03/2017 01:47 PM JPERRY
No t-pole on site
B114 01 7/11/17 JH R*BLDG MONO SLAB/TEMP SVC POLE TIME: 17:00 VRU #: 002995108
7/11/17 DA T/S: 07/10/2017 12 :16 PM DJOHNSON
CUSTOMER IS ASKING FOR A SLAB INSPECTION, RADIANT HEAT
UNDER SLAB INSPECTION.
***LOCK BOX CODE IS 1981***
1)Res check has R 30 for ceiling it needs to be
R38.2)Garage footing needs to be continuous across garage
door per plan.3)Clean out loose dirt from bottom of
footings.4)There are voids behind insulation that needs
tobe addressed.5)Slab insulation needs to verticle & all
the way against inside of footing per engineers detail.
8111 01 7/13/17 JH R*BLDG SS.LP INSP/TEMP SVC POLE TIME: 17:00 VRU 4: 002996577
7/13/17 AP T/S: 07/12/2017 01:57 PM BPETRICH
RADIANT HEAT UNDER SLAB - ALSO PLEASE INSPECT TPOLE -
PREMISE WILL BE WRITTEN ON PERMIT CARD
T-POLE PASSED
R425 01 10/09/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU if: 003035599
10/09/17 DP T/S: 10/06/2017 12:57 PM LLUCAS
LOCK BOX CODE#1981
CONTINUED ONTO NEXT PAGE
PREPARED 2/19/18, 14:02:35 INSPECTION TICKET PAGE 2
Harnett County INSPECTOR: IVR DATE 2/20/18
t
ADDRESS 4260 NC 210 S SUBDIV: J G LAYTON ESTATE
CONTRACTOR : SOUTH EASTERN GC INC PHONE : (910) 474-6778
OWNER . . : SUMMERS SHANE E & CHAUNTEL M PHONE :
PARCEL . . : 12-0548- - -0016- -27-
APPL NUMBER: 16-50038372 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
1)Missing studs under top plate joints in garage on front
wa11.2)Missing nails in roof truss hnagers to left of
house/garage door.3)Missing anchor bolts each side of
exterior doors.4)Missing nail guards & fire caulk on water
lines in laundry room on garage wa11.5) 100 psi on water
line test.6)Fasten all toilet flanges per code.7) Plans show
ballon frame on walls in living room & dining room need
engineer letter.8)Fill all holes under tubs &
showers.9)Missing hurricane straps on walls in living &
dining room.10)Missing baffels per code.11)Missing big
window in living room.12)Strap all trunk line duct every
64" per code.13)Nail & seal all air barriers in
chases.14)Missing air barrier over 2ply lvls in foyer.15)Nee
Missing floor recepacle on open side of loft.16)Need full
set of truss drawings & layout to finish
inspection.17)Missing smoke detector outside of
bed5.18)Nail house wrap 12"-18" each stud with 1" fastener
per house wrap installtion instructions.
DO NOT INSULATE OR SIDE
R425 02 10/24/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003043130
10/24/17 DP T/S: 10/23/2017 01:01 PM LLUCAS
ITEM 12 & 13 were not corrected
I129 01 10/27/17 JH R*INSULATION INSPECTION VRU #: 003045259
10/27/17 AP
R425 03 10/27/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003045705
10/27/17 AP T/S: 10/26/2017 02 :54 PM BPETRICH
H824 01 12/04/17 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003062395
12/04/17 AP T/S: 12/05/2017 10:47 AM KHINSON
T/S: 12/05/2017 10:47 AM KHINSON
R125 01 12/29/17 JH ONE TRADE ROUGH IN TIME: 17:00 VRU #: 003070976
12/29/17 AP T/S: 12/22/2017 04 :14 PM JBROCK
STONE PREP
M305 01 1/24/18 JH R*PLUME SEWER CONNECTION TIME: 17:00 VRU #: 003079274
1/24/18 AP T/S: 01/23/2018 12:29 PM JBROCK
P307 01 1/24/18 JH R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003079662
1/24/18 DA T/S: 01/24/2018 08:41 AM LLUCAS
T/S: 01/24/2018 08:41 AM LLUCAS
1. WATER LINE NOT 12"DEEP 2. CUT OFF FOR WATERLINE NEEDS TO
BE 12"FROM METER BOX OR LESS.
P307 02 1/29/18 JH R*PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003081577
1/29/18 AP T/S: 01/26/2018 08:50 AM JBROCK
E209 01 1/31/18 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003083508
1/31/18 DA T/S: 01/31/2018 09:18 AM LLUCAS
T/S: 01/31/2018 09:19 AM LLUCAS
CONTINUED ONTO NEXT PAGE
Pj$PARED 2/19/18, 14:02:35 INSPECTION TICKET PAGE 3
Harnett County INSPECTOR: IVR DATE 2/20/18
ADDRESS . : 4260 NC 210 S SUBDIV: J G LAYTON ESTATE
CONTRACTOR : SOUTH EASTERN GC INC PHONE : (910) 474-6778
OWNER . . : SUMMERS SHANE E & CHAUNTEL M PHONE :
PARCEL . : 12-0548- - -0016- -27-
APPL NUMBER: 16-50038372 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
1. MISSING PANEL COVER IN GARAGE 2 .MISSING SMOKE DETECTOR
OUTSIDE OF RIGHT BEDROOM 3 . MISSING METERBASE ON BACK OF
HOUSE
M409 01 1/31/18 JH R*GAS PIPING TIME: 17:00 VRU #: 003083052
1/31/18 AP T/S: 01/30/2018 01:06 PM JBROCK
T/S: 01/31/2018 09:22 AM LLUCL5
E209 02 2/01/18 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003083888
2/01/18 DP T/S: 01/31/2018 01:52 PM BPETRICH
CALL DREW AT 910.890.4370 AT LEAST AN HOUR BEFORE YOU GET
THERE SO HE CAN MEET YOU WITH A LADDER FOR HVAC START UP
1)Panel cover in garage has hole inside panel.2)Need to
label AHU in garage.3)Need ladder for AHU in attic.
E209 03 2/02/18 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003084548
2/02/18 AP T/S: 02/01/2018 12:06 PM BPETRICH
R429 01 2/12/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003087681
2/12/18 CA T/S: 02/08/2018 04:21 PM BPETRICH
PER DREW
R429 02 2/16/18 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003089828
2/16/18 DP T/S: 02/14/2018 04:38 PM DJOHNSON
,44-Fire caulk around pipe in garage ceiling at AHU.t)Need
protection for the water lines in garage at slab.)lDead
bolt for front door$1 Ladder for attic access.f)Energy
certificate.)Missing sidding at meter & seal around meyter
box.4ISeal post at stone work.8)House #s.
R429 03 2/20/18 [� / FOUR TRADE FINAL TIME: 17:00 VRU #: 003090990
J•)(� /f T/S: 02/16/2018 02 :49 PM LLUCAS
COMMENTS AND NOTES