STRUCTURAL EVALEng. Number OAA724871_C2_01
February 13 2018
Page 1 of 2
ATC Tower Services, Inc. 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office – 919-466-5414 Fax - www.americantower.com
Structural Evaluation
ATC Site Number & Name 21278, Mcneil Cemetery NC, NC
Carrier Site Number & Name 172082 , RAY
Site Location 14180 NC 210 South *
SPRING LAKE, NC 28390-7840, Harnett County
35.22349444 N / 78.9397 W
Tower Description 176 ft Self Supported Tower
Basic Wind Speed
Basic Wind Speed w/ Ice
Code
96 mph (3-Second Gust)
30 mph (3-Second Gust) w/ ¾” ice
ANSI/TIA-222-G / 2009 IBC / 2012 North Carolina Building Code
Existing and Reserved Equipment
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
175.0 175.0
6 RFS ATM192012-0
Sector Frame
(12) 1 5/8" Coax
(4) 0.74" 8 AWG 7
(1) 0.28" Fiber
(1) 3/8" RET Control
Cable
AT&T Mobility
2 Raycap DC6-48-60-18-8F
3 Ericsson RRUS A2 Module
3 Ericsson RRUS-11 800MHz
3 Ericsson RRUS-12 B2
3 Ericsson RRUS-32 B30
6 Kathrein 742 213
2 Commscope SBNHH-1D65A
2 Powerwave P45-16-XLH-RR
2 Commscope SBNHH-1D65C
163.0 163.0 3 Ericsson KRY 112 489/2 Side Arm (6) 1 5/8" Coax
(1) 1.4" Hybrid T-Mobile 3 Ericsson AIR 21, 1.3M, B4A B2P
150.0 150.0
3 Alcatel-Lucent 800MHz 2X50W RRH w/
Filter
Sector Frame (4) 1 1/4" Hybriflex Sprint Nextel
3 Alcatel-Lucent 1900MHz 4X45 RRH
3 Alcatel-Lucent TD-RRH8x20-25 w/ Solar
Shield
3 RFS APXVTM14-ALU-I20
3 RFS APXVSPP18-C-A20
140.0 140.0 2 Raycap RRFDC-3315-PF-48 Sector Frame (6) 1 5/8" Coax
(2) 1 5/8" Fiber Verizon 3 Antel BXA-70080/8CF
Eng. Number OAA724871_C2_01
February 13 2018
Page 2 of 2
ATC Tower Services, Inc. 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office – 919-466-5414 Fax - www.americantower.com
Equipment to be Removed
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
140.0 140.0
6 Andrew HBXX-6517DS-VTM
- (6) 1 5/8" Coax Verizon 3 Antel BXA-70063/8CF __
6 RFS FD9R6004/1C-3L
6 Ericsson RRUS-32
Proposed Equipment
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
140.0 140.0
6 Ericsson 8843 Rev 2
Sector Frame (6) 1 5/8" Fiber Verizon 6 Ericsson Radio 4449 - B13&B5
3 Raycap RCMDC-6627-PF-48
6 Commscope NHH-65C-R2B
1 Mount elevation is defined as height above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna
above grade level (AGL).
Install proposed coax alongside existing Verizon Wireless coax.
The existing and proposed loads listed in the tables above are compared to the tower’s current design capacity
or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are
found different from those listed in the tables. The subject tower and foundation are adequate to support the
above stated loads in conformance with specified requirements.
IPD/ANG