DOCUMENTS Initial Application Date:3/a ) I $ Application ft I SC:0 T 3TsN
CU#
COUNTY OF HARNETT RESIDENTIAL LAND USE APPLICATION
Central Permitting 108 E.Front Street Lillington,NC 27548 Phone:(910)893-7525 ext2 Far(910)893-2793 www.harne8.org/pennits
^A RECORDED SURVEY MAP,RECORDED DEED(OR OFFER TO PURCHASE)&SITE PLAIT ARE REWIRED WNEN SUBMRIINGA LAID USE APPLICATION'
LANDOWNER DONALD HOLDER MellingAddraes:18 DELMAR COURT
Cm, FUQUAY VARINA Slate:NC Zp:27526 Contac No: 704288-0128 Email: KBIRMINGHAMQPOWERHOk
APPLICANT•:POWER HOME SOLAR Mailing Address:Bib N MAIN STREET
City: MOORESVILLE Stole: LIT LIT28115 Contact No: 704288-0128 ErT S:
'Please fill out appinm Information if different than IandeMw
CONTACT NAME APPLYING IN OFFICE:KIMBERLY BIRMINGHAM Phone#704288M128 �-L
PROPERTY LOCATION:Subdivision: VICTORIA HILLS 2 Lot* 50 Lot Size: 'Co [
State Road#18 State Road Name: DELMAR Map Book&Paget/CO.4 / 70
Parcel:�())��8�� 0005.3 O( BIOS l PIN: OD�1,�U�sS -nn07 - cc7q 1.00YJ
Zoning:l:.A3 Flood Zone: X Watamhed Deed Book&PageO"4� / 7�5 Power Company:
'New structures with Progress Energy as service provider need to supply premise number from Progress Energy.
PROPOSED USE
Monolithic
❑ SFD:(Size x )#Bedrooms:_#Bahs:_Basement(wAvo bat):_Garage:_Dedc_Crawl Space:_Slab:_Slab:_
(Is the bonus mom finished?( ,yes ( )no w/a closet?( )yes Li no('dyes add In with#bedrooms)
❑ Mad:(Sim x )#Bedrooms_#Baths_Basement(wilco bath) Garage:_Site Bunt Deck:_ On Frame_Off Frame_
(Is the second floor finished?( yes ( )no Any other site built additions?(___)yes U no
❑ Manufactured Home: SW DW_TW(Size x )#Bedrooms:_Garage: (site built? )Deck: (eke built? 1
O Duplex:(Size_x )No.Buildings: No.Bedrooms Per Unit
O Home Occupation:#Rooms: Use: Hours of Operation: *Employees:_
OF Addition/Accessory/Other(Size x )Use:SOLAR OSI R
Closets in addition?( )yea Li no
Water Supply _County Existing Well New Well(#of dwellings using well )`Must have operable wets,before final
Sewage Supply: New Septic Tank(Complete Checklist Existing Septic Tank(Complete Checklist _County Sewer
Does owner of this trap of land,own land that contains a manufactured home within five hundred feet(500')of boat listed above?U yea (J no
Does the property contain any easements whether underground or overhead U yea U no
Structures(existing or proposed):Single family dwstgngs: tie-4
' Mamdactured Homes: Other(specify):
SVi/
Required Residential rty Line Setbacks: Comments:
Front Minimum ActuaT�
Rear
Closest Side
Sidestreeticomer let
Nearest Building
on ame lot
Residential Land Use Application Page 1 of 2 03/11
APPLICATION CONTINUES ON BACK
SPECIFIC DIRECTIONS TO THE PROPERTY FROM LILLINGTON:
If permits are granted I agree to conform finances an. State of Nath Carolina regulating such work and the specifications of plans submitted.I hereby state that foregoing state a to and co -• a , best of my knowledge. Permit subject to revocation I false Information is provided.
ifPiet'DI ,. 3/2.118
Signature of Owner or Owners Agent Date
"1t I the owner/appllcanta responsibility to provide the county with any applicable Information about the subject property,Including but not limited
to:boundary Information,house location,underground or overhead easements,etc.The county or Its employees are not responsible for any
Incorrect or missing Information that is contained within these applications.'"
"This application expires S months from the Initial date If permits have not been Issued"
Residential Land Use Applicalion Page 2 of 2 03/11
Application#
Harnett County Central Permitting
PO Box 65 Lillington, NC 27546 - Ph:910-893-7525 - Fx:910-893-2793 - www.harnett.org/permits
Certification of Work Performed By Owner/Contractor
(Individual Trade Application)
Owner(s)of Structure: Donald Holder Phone:704-288-0128
Owner(s) Mailing Address:18 Delmar Court Fuquay Varina, NC 27526
Land Owner Name (s): Phone:704-288-0128
Construction or Site Address: 18 Delmar Court
PIN# Parcel#
Job Cost: 19,470 Description of Work to be done 12 roof mounted modules,grid tied, 3.54 KW Solar
Install.
Mechanical: New Unit With Ductwork_ New Unit Without Ductwork_ Gas Piping Other
Electrical*: 200 Amp <200 Amp Service Change_ Service Reconnect_ Other
* For Progress Energy customers we need the premise number
Plumbing: Water/Sewer Tap Number of Baths Water Heater
Specific Directions to Job from Lillington:
Subdivision: Lot#:
I Bryan Law will provide the Electrical labor on this structure.
(Contractors Name) (Trade)
I am the building owner or my NC state license number is 26074-U ,which entitles me to
perform such work on the above structure legally. All work shall comply with the State Building Code and all
other applicable State and local laws, ordinances and regulations.
Power Home Solar 704-288-0128
Contractor's Company Name Telephone
919 N Main Street Mooresville NC 28115 kbirmingham@powerhome.com
Address Email Address
26074-U
License# 717.
Structure Owner/Contractor Signature: "-" Date:0 211 6/2 01 8
By signing this application you affirm that you have obtained permission from the above listed license holder to
purchase permits on their behalf. If doing the work as owner you understand that you cannot rent, lease or sell
the listed property for 12 months after completion of the listed work.
"Company name, address, 8 phone must match information on license
Penn FUSION
S. Broad St.
0 Lansdale, PA 19446
Engineering (215)361-8040
February 15,2018
PowerHome Solar
919 N. Main St
Mooresville, NC 28115
RE: Holder Residence
18 Delmar Ct, Fuquay Varina, NC 27526
Client Project#: 18HOLD
PFE Project#: 181571
On behalf of PowerHome Solar, Penn Fusion Engineering LLC(PFE)performed a structural analysis of the roof at the above
referenced location.The purpose of our analysis was to determine if the existing roof system is structurally sufficient to
support the new photovoltaic moudles in addition to the code required design loads. Our analysis is based on the information
provided by PowerHome Solar and is isolated only to the areas where the modules are intended to be placed.
System Specifications:
Total System Size: 3.54 kW/DC
Panel Specs: (12) Mission Solar- MSE295SQST
Inverter Specs:(12) Enphase - 1E16+
Racking System: Iron Ridge - Flush Mount
The modules are to be located on the following roof plane:
Mounting Rafter Rafter Horizontal Collar Collar Tle Sheathing Shingle Number of Ceiling
Plane Size Spacing Span Ties Spacing Type Shingle Layers Profile
1 2x6 16" I 2ft. bin. N/A 0" CDX 1/2" Asphalt
Shingles 1 Flat
The roof design has been analyzed in accordance with the 2012 North Carolina Residential Code with design loads as follows:
Ground Snow(Pg): 15 psf
Wind Speed(V): 94 mph
Mounting Plane 1
The calculations for these structural members are attached. It has been determined by this office that the roof structure is
adequate to support the new PV modules in addition to the code required design loading.
Attach the module rail brackets to the roof with 5/16' lag bolts at 48 on center maximum. Provide a minimum of 2"of
penetration into the wood members.
This office has determined that the installation of the PV System as specified above will meet the structural requirements of
the 2012 North Carolina Residential Code and ASCE7-05 when installed in accordance with the manufacture's instructions.
If you have any questions regarding this analysis, please feel free to contact us.
111 t lIHlp4
.``1tN CAP? "s0
Best Regards, C 0' FES3rp`(ti
Penn Fusion Engineering LLC S _4- yy:▪ �
- •¢ SEAL
- -• k30
Andrew D. Leone, P.E. �l• r. 'J
Principal • z.
z-; '1'.:VIV HE s�
E1v ole 1,5•
• Penn FUSION 152 S. Broad St.
Lansdale, PA 19446
Engineering (267)640-2758
Client Name: PowerHome Solar
PFE Project Number: 181571
Client Project Number: 18HOLD
Project: Holder Residence
Address: I8 Delmar Ct
Fuquay Varina, NC 27526
Description: Mounting Plane 1
Calculations By: ADL
Date: February 15,2018
/roof Construction
2x6 Rafters at 16"on center
A= 8.25 in?
lx= 20.8 in°
Sx= 7.56 in3
Wood Species= Doug-Fir Larch#2
Fb- 900 psi
Fv= 180 psi
E= 1.6e+06 psi
Roof Slope= 33 '
Rafter Span= 12.54 ft
Ceiling Attached to Rafters?: No
Design Criteria
Ground Snow(P9): 15 psf
Design Wind Speed: 94 mph
Live Load: 20 psf
Dead Load: 4.86 psf
PV Modules: 3.58 psf
Wind Calculations
Directionality Factor(Kd): 0.85
Topographic Factor(Kn): 1
Velocity Pressure Exposure 0 7
Coefficient(K,):
Importance Factor(I): 1
Velocity Pressure(q,): 13.46 psf
Tributary Square Footage on 10.83 ft2
Component:
Component Roof Pressures: 14.49 / -18.48 psf
Snow Load Calculations
Exposure Factor(Ce):
Thermal Factor(Cs): 1
Importance Factor(I): 1
Flat Roof Snow Loads(Pd: 10.5 psf
Roof Slope Factor(Cs): 0.925
Sloped Snow Loads(Ps): 9.7125 psf
Unbalanced Snow Load: 15 psf
Member Calculations
Bending
•
Ma: 744.88 'nib
fb: 1181.95 psi
Load Duration Factor(Ce): 1.15
Stability Factor(CO:
Wet Service Factor(Cu): I
Temperature Factor(CT): 1
Size Factor(Cr): 1.3
Flat Use Factor(CO: 1
Incising Factor(C): 1
Repetitive Member Factor(C): 1.15
Fb: 900 psi
F'b: 1547.33 psi 1181.95<a1547.33 OK In Bending
Shear
ye: 237.66 lb
f.: 43.21 psi
Load Duration Factor(Cd): 1.15
Wet Service Factor(Cu): 1
Temperature Factor(CT): 1
Size Factor(Cr): 1.3
Flat Use Factor(CO: 1
Incising Factor(C): 1
180 psi
207 psi 43.21<.4207 OK in Shear
Deflection
Live Load Deflection(4L): 0.45 in L/338 OK In Live Load
Deflection
Total Load Deflection (AT): 0.63 in L/238 OK in Total Load
Deflection
Uplift Calculation
Tributary Square Footage on 10.83 ft2
Component:
Uplift Pressure: -18.48 psf
Uplift per Lag: -200.2 lbs
Lag Screw Diameter: 5/16 in
Allowable Withdrawal per Inch: 490.99 lbs/in
Minimal Screw Penetration: 0.41 in
Install 5/16'diameter lag screws @ 48 on center with
minimum penetration of 2"into rafter.
HARNETT COUNTY CENTRAL PERMITTING
P.O. BOX 65
LILLINGTON, NC 27546
For Inspections Call : (910) 893-7525 Fax: (910) 893-2793
Application Number 18-50043450 Date 3/08/18
Property Address 18 DELMAR CT
PARCEL NUMBER 08-0653-01- -0105- -89-
Application type description CP STANDALONE TRADE - RESIDENTIAL
Subdivision Name VICTORIA HILLS PHASE 7
Property Zoning RES/AGRI DIST - RA-30
Owner Contractor
HOLDER DONALD L POWER HOME SOLAR LLC
18 DELAMR COURT 919 N. MAIN STREET
FUQUAY-VARINA NC 27526 MOORESVILLE, NC 28115
MOORESVILLE NC 28115
(704) 237-3928
Applicant
POWER HOME SOLAR
919 N MAIN ST
MOORESVILLE NC 28115
(704) 288-0128
--- Structure Information 000 000 SOLAR PANELS ON THE ROOF
Flood Zone FLOOD ZONE X
Other struct info PROPOSED USE SOLAR PANELS
WATER SUPPLY NA
Permit RESIDENTIAL ELECTRICAL PERMIT
Additional desc . SOLAR PANELS
Phone Access Code 1232024
Issue Date . . 3/08/18 Valuation . . . . 0
Expiration Date . 3/08/19
Special Notes and Comments
T/S : 03/02/2018 02 : 30 PM JBROCK ----
18 DELMAR CT - VICTORIA HILLS 2
HARNETT COUNTY CENTRAL PERMITTING
P.O. BOX 65
LILLINGTON, NC 27546
For Inspections Call : (910) 893-7525 Fax: (910) 893-2793
Page 2
Application Number 18-50043450 Date 3/08/18
Property Address 18 DELMAR CT
PARCEL NUMBER . 08-0653-01- -0105- -89-
Application description . . CP STANDALONE TRADE - RESIDENTIAL
Subdivision Name VICTORIA HILLS PHASE 7
Property Zoning RES/AGRI DIST - RA-30
Permit RESIDENTIAL ELECTRICAL PERMIT
Additional desc . SOLAR PANELS
Phone Access Code 1232024
Required Inspections
Phone Insp
Seq Insp# Code Description Initials Date
999 211 E211 R*ELEC ABOVE CEILING / /
999 217 E217 R*ELEC RECONNECT / /
999 205 E205 R*ELEC UNDER SLAB / /
999 215 E215 R*ELEC. UND. POOL / /
999 213 E213 R*ELECTRICAL UNDERGROUND /
999 131 R131 ONE TRADE FINAL / /
999 125 R125 ONE TRADE ROUGH IN / /
.s
NPh 'mia'i
i5T ,5 it• * *
ner: 2313C,CF,
.,
fete3A18,18 5e rr.:eipLop:,.�.327593A18,18E9
2 i 5dg4.345 4ament
1r. DELM R IT
FUOUr1Y-4AFP:A. 62
31 GEF
ROOF 55L5R [ N _5 [ai+.u0
pOi/F+ h01E SCLAF;
1EpEe dPt.;
Et CAFC 1P2E'EN 630.20
R
Total ireit- 1E1 AE
704+1 p/ ent iAI.r.
Pans date: 31PitLF
.e 15Ff UU FOP :'2HE NYF_i.. H: