2017-12-27-Sheetz Lillington Building Permit Set2'-4"0'-8"BID SETN O R T H CAROLINARANDAL S. DI VI N EY PR O FESSIONALENGINEER SEAL036522 BID SETN O R T H CAROLINARANDAL S. DI VI N EY PR O FESSIONALENGINEER SEAL036522N O R T H CAROLINARANDAL S. DI VI N EY PR O FESSIONALENGINEER SEAL036522 BID SETN O R T H CAROLINARANDAL S. DI VI N EY PR O FESSIONALENGINEER SEAL036522 L6x4x5/16, W/ 3/8" DIA x 4" LAG BOLTAND WASHER @ 16" OC INCLUDING ENDS.END BOLT TO BE WITHIN 5" OF LVLBEAM SADDLE. EXTEND ANGLE 8"BEYOND OPENING ON EITHER SIDE.L6x4x5/16, W/ 3/8" DIA x 4" LAG BOLTAND WASHER @ 16" OC INCLUDING ENDS.END BOLT TO BE WITHIN 5" OF LVLBEAM SADDLE. EXTEND ANGLE 8"BEYOND OPENING ON EITHER SIDE.JOIST HANGERL6x4x5/16, W/ 3/8" DIA x 4" LAG BOLTAND WASHER @ 16" OC INCLUDING ENDS.END BOLT TO BE WITHIN 5" OF LVLBEAM SADDLE. EXTEND ANGLE 8"BEYOND OPENING ON EITHER SIDE.BID SETN O R T H CAROLINARANDAL S. DI VI N EY PR O FESSIONALENGINEER SEAL036522 BID SETN O R T H CAROLINARANDAL S. DI VI N EY PR O FESSIONALENGINEER SEAL036522 MECHANICAL ABBREVIATIONSABVABOVEAFFABOVE FINISHED FLOORARCHARCHITECTAPDAIR PRESSURE DROPAPPROXAPPROXIMATEATCAUTOMATIC TEMPERATURE CONTROLAUTOAUTOMATICAUXAUXILIARY@ATBDBACKDRAFT DAMPERBLWBELOWCDCEILING DIFFUSERCFMCUBIC FEET PER MINUTECLGCOOLINGCOCLEANOUTCONNCONNECTIONCONTCONTINUATIONDETLDETAILDIADIAMETERDISCHDISCHARGEDNDOWNDPRDAMPERDWGDRAWINGEAEACHEATENTERING AIR TEMPERATUREECELECTRICAL CONTRACTOREGEXHAUST GRILLEEQUIPEQUIPMENTESPEXTERNAL STATIC PRESSUREEWTENTERING WATER TEMPERATUREEXHEXHAUSTEXTEXTERIORFCFLEXIBLE CONNECTORFDFLOOR DRAINFINFINISHEDFLEXFLEXIBLEFLRFLOORFRFROMGAGAUGEGALVGALVANIZEDHCHEATING CONTRACTORHOAHAND OFF AUTOMATICHORIZHORIZONTALINSULINSULATIONINTINTERIORMATMIXED AIR TEMPERATUREMAXMAXIMUMMFGMANUFACTURERMINMINIMUMMTDMOUNTEDMTLMETALNOMNOMINALOAOUTSIDE AIROCON CENTEROS&YOUTSIDE SCREW & YOKEPCPLUMBING CONTRACTORPCFPOUNDS PER CUBIC FOOTPDPRESSURE DROPRARETURN AIRRCDRADIAL CEILING DIFFUSERREQ'DREQUIREDRETRETURNRGRETURN GRILLERLREFRIGERANT LIQUIDRSREFRIGERANT SUCTIONSASUPPLY AIRSDSMOKE DETECTORSHTSHEETSPSTATIC PRESSURESPECSSPECIFICATIONSSRWSUPPLY REGISTER WALLSTDSTANDARDSTRUCTSTRUCTURESUPSUPPLYTGCTRANSFER GRILLE CEILINGTRANSTRANSITIONTSPTOTAL STATIC PRESSURETYPTYPICALvcd-rvolume control damper - remoteVCDVOLUME CONTROL DAMPERVELVELOCITYVERTVERTICALW/WITHW/OWITHOUTMECHANICAL LEGENDDETAILDESCRIPTIONSUPPLY, RETURN, EXHAUST DUCTWORKRECTANGULAR OR ROUND DIMENSIONSNOTED ON DRAWINGS INDICATE INSIDEDIMENSIONSRISE OR DROP IN DUCTWORKSUPPLY AIR OR OUTSIDE AIR DUCT SECTIONRETURN DUCT SECTIONEXHAUST DUCT SECTIONSUPPLY CEILING DIFFUSERRETURN GRILLEEXHAUST GRILLE OR TRANSFER AIR GRILLEVOLUME CONTROL DAMPERTTHERMOSTATAUDIBLE / VISIBLE ALARMRTSREMOTE TEMPERATURE SENSORAVFLEXIBLE CONNECTORRADIAL CEILING DIFFUSERTURNING VANE (USE ONLY WHEN RADIUSTYPE ELBOWS ARE NOT POSSIBLE)RADIUS ELBOW USE 1.5 RADIUSWHEREVER POSSIBLE. USE 1.0 RADIUSWHERE A 1.5 RADIUS WILL NOT FIT1.51.0HUMIDIty SENSORHSSMOKE DETECTORSDCLOSEDOPENDAMPER BLADE IN FULLYCLOSED POSITIONDAMPER BLADE INPARTIALLY OPEN POSITION3/8" SQUAREAXLE SHAFT2" INSULATIONSTAND-OFFBRACKETHANDLE W/LOCKINGWING NUTNO SCALESIDE ELEVATIONSECTION'Y''X'NOTES:1. DAMPER TO HAVE 90° RANGE OF MOTION FROM 'X' AXIS TO 'Y' AXIS. DAMPER IS FULLY OPEN WHENTHE DAMPER HANDLE IS 0° FROM THE 'X' AXIS, DAMPER IS FULLY CLOSED WHEN THE DAMPER HANDLEIS 90° FROM THE 'X' AXIS.2. ROUND DAMPER IS SHOWN ON DETAIL, DAMPER INSTALLATION SHALL BE SIMILAR FOR RECTANGULAR DAMPERS.3. (DAMPER IS TO BE POSITIONED FULLY OPEN AT TIME OF INSTALLATION, CONTRACTOR TO ADJUSTDAMPER POSITION AT TIME OF SYSTEM BALANCE AND MARK AND LOCK DAMPER IN BALANCED POSITION)4. insulation stand-off bracket can be omitted where there is no exterior wrap insulation.VOLUME CONTROL DAMPER DETAIL W/ INSULATIONSTAND-OFF BRACKETexterior wrap insulation not shown for clarityHHHTRECTANGULAR DUCT REINFORCEMENTTRANSVERSE JOINT REINFORCEMENTINTERMEDIATE REINFORCEMENTT-10 STANDING SREINFORCEMENT CLASS - E(H) 1 1/8 x 18 GADETAIL IS MINIMUM CONSTRUCTION FOR DUCTWORK. ALTERNATIVE METHODSSHALL BE SUBMITTED TO ENGINEER FOR APPROVAL.ANGLEREINFORCEMENT CLASS - ECOLD FORMED (H) 1 1/4 x (T) 12 GAHOT ROLLED - (H) 1 x (T) 1/8DUCTWORK IS 2"W.G. STATIC UP TO 30" DIMENSION, MINIMUM RIGIDITY CLASS E,MINIMUM 24 GAGE, WITH MINIMUM REINFORCEMENT SPACING OF 5'.GENERAL MECHANICAL NOTES1.THE DRAWINGS ARE INTENDED TO COVER SYSTEMS WHICH WILL FIT THE AVAILABLE SPACE, WHICH WILL NOT INTERFERE WITH THE GENERALSTRUCTURAL DESIGN. CAREFULLY EXAMINE THE DRAWINGS FOR ALL BRANCHES OF WORK AND BE RESPONSIBLE FOR THE PROPERFITTING OF MATERIAL AND APPARATUS INTO THE BUILDING. COORDINATE THE EXACT LOCATION OF EQUIPMENT AND EQUIPMENTCONNECTIONS WITH THE ARCHITECT AND EQUIPMENT SUPPLIER.2.INSTALLATION SHALL BE PERFORMED IN ACCORDANCE WITH 2012 NORTH CAROLINA MECHANICAL CODE AND LOCAL APPLICABLE CODES.3.GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS, AND PAY ALL COSTS IN CONNECTION WITH THE WORK FILE ALL NECESSARY PLANS,PREPARE ALL DOCUMENTS AND OBTAIN ALL NECESSARY APPROVALS OF ALL REGULATING AUTHORITIES HAVING JURISDICTION OBTAINALL REQUIRED CERTIFICATES OF INSPECTION FOR WORK AND DELIVER SAME TO ARCHITECT BEFORE REQUEST FOR ACCEPTANCE ANDFINAL PAYMENT WORK.4.DRAWINGS ARE DIAGRAMMATIC FOR PIPING, CONDUITS AND DUCTWORK THAT IS NOT SHOWING DETAIL. SIZES OF PIPING, CONDUITS ANDDUCTWORK AND THEIR LOCATIONS ARE INDICATED, BUT IT IS NOT INTENDED TO SHOW EVERY OFFSET, FITTING OR EVERY STRUCTURALDIFFICULTY THAT MAY BE ENCOUNTERED DURING INSTALLATION OF THE WORK. THE ALIGNMENT OF PIPING, CONDUIT, OR DUCTWORK SHALLBE VERIFIED FROM THAT INDICATED ON THE DRAWINGS WITHOUT EXTRA EXPENSE TO THE OWNER WHERE NECESSARY TO AVOIDSTRUCTURAL OR MECHANICAL DIFFICULTIES, OR TO AVOID THE WORK OF ANY OTHER TRADES.5.CHECK AND VERIFY ALL DIMENSIONS, SITE CONDITIONS, DRAWINGS AND SPECIFICATIONS. REPORT ANY AND ALL DISCREPANCIES TO THEARCHITECT AT ONCE.6.PERFORM LABOR IN A THOROUGH AND COMPLETE WORKMAN LIKE MANNER AND WITH ALL REASONABLE RAPIDITY TO THE SATISFACTIONOF THE ARCHITECT.7.CUT COMPLETED CONSTRUCTION WORK ONLY IF SLEEVES, OPENINGS, CHASES, ETC., WERE INADVERTENTLY OMITTED AND ONLY WITH THESPECIFIED APPROVAL OF THE ARCHITECT.8.ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. SHOULD ANYVARIANCE BETWEEN PLANS AND SPECIFICATION OCCUR WITH THESE INSTRUCTIONS, THE ARCHITECT OR ENGINEER SHOULD BE CONTACTEDIMMEDIATELY SO THAT ANY VARIATIONS IN INSTALLATION CAN BE KNOWN BY ALL PARTIES CONCERNED.9.EACH COMPLETED SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE OF THE WORK BYTHE OWNER, THE CONTRACTOR SHALL GUARANTEE EACH SYSTEM IN WRITING TO BE FREE OF DEFECTS OF MATERIALS AND WORKMANSHIPAND TO PERFORM SATISFACTORILY UNDER ALL CONDITION OF LOAD OR SERVICE.10.DETERMINE IN ADVANCE OF CONSTRUCTION THE LOCATION OF ALL DUCTWORK, HANGERS, EQUIPMENT, ETC. COORDINATE THE LOCATIONOF DUCTWORK, PIPING AND DIFFUSERS WITH ALL OTHER TRADES. IN GENERAL, INSTALL DUCTWORK AND PIPING AS HIGH AS POSSIBLE,THROUGH OR BETWEEN STRUCTURAL MEMBERS IF SPACE PERMITS.11.ALL CONCEALED SUPPLY DUCTWORK SHALL BE EXTERNALLY INSULATED WITH 2" THICK FOIL BACKING FIBERGLASS WITH .75 PCF DENSITY.(INSTALLED R-VALUE @ 25% COMPRESSION = R-5.6 MIN). THE DUCT INSULATION SHALL CONFORM TO NCMC SECTIONS 604.2 THROUGH604.13.12.THE AIR DISTRIBUTION SYSTEM AND RELATED ITEMS SHALL BE INSTALLED IN ACCORDANCE WITH 1995 SECOND EDITION SMACNA HVACDUCT CONSTRUCTION STANDARDS FOR METAL AND FLEXIBLE DUCTS AT SEAL / PER CLASS SPECIFIED: SA @ +2"SP SEAL CLASS 'B', RA @-2"SP SEAL CLASS 'C', EA -2"SP SEAL CLASS 'B'.13.RIGID DUCTS SHALL BE CONSTRUCTED OF GALVANIZED SHEET METAL. CHANGES IN DUCT SIZE OR SHAPE SHALL BE MADE WITHTRANSITIONS AS LONG AS PRACTICABLE, WITH THE ANGLE BETWEEN THE SIDE AND AXIS OF THE DUCT BETWEEN 15 AND 30 DEGREES,UNLESS OTHERWISE SHOWN ON THE DRAWINGS OR AUTHORIZED BY ARCHITECT. THE MINIMUM GALVANIZED SHEET METAL THICKNESS FORDUCT CONSTRUCTION SHALL BE 24 GAUGE THRU 30" DUCTS, 22 GAUGE FOR 31" THRU 42" DUCTS.14.FLEXIBLE DUCT SHALL BE FACTORY FABRICATED ASSEMBLY, SPIRAL CONSTRUCTION, 2" FIBERGLASS BLANKET INSULATION AND COATEDFIBERGLASS MESH LINER. MINIMUM R-6 FLEXIBLE DUCT SHALL BE SUITABLE FOR 1-1/2 TIMES THE DUCT PRESSURE AT THE CONNECTION.INSTALL WITH A MINIMUM OF BENDS AND EXTENDED STRAIGHT WHERE POSSIBLE, MAXIMUM RUN OF FIVE FEET, MINIMUM BEND RADIUS OF1-1/2 TIMES THE DUCT DIAMETER MEASURED FROM THE CENTER LINE. SEAL FLEXIBLE DUCT TO MAIN DUCT INSULATION.15.GREASE DUCT SHALL BE CONSTRUCTED OF STEEL, MINIMUM 16 GAUGE, OR SHALL BE LISTED AND LABELED FACTORY- BUILT COMMERCIALKITCHEN GREASE DUCT. PROVIDE A SEALED DUCT-ENCLOSED VENTED TO THE OUTSIDE, WITH TOTALLY FOIL-ENCAPSULATED,NON-COMBUSTIBLE 2000 DEGREE F RATED, FLEXIBLE ZERO CLEARANCE FIREPROOFING WRAP INSULATION FOR HORIZONTAL ANDVERTICAL COMMERCIAL KITCHEN GREASE DUCT APPLICATIONS. THE INSULATION SHALL BE APPLIED AS PER MANUFACTURERSRECOMMENDATIONS. THE FIRE WRAP INSULATION SHALL MEET ASTM E2336. (AS MANUFACTURED BY THERMAL CERAMICS) PROVIDED BYTHE MECHANICAL CONTRACTOR. before wrapping THE GREASE DUCT with insulation the contractor SHALL shall schedule withthe code enforcement official to witness a visual light test of the grease duct IN ACCORDANCE TO NCMC SECTION 506.3.2.5.16.DUCTS SHALL BE INSTALLED AND CONNECTED TO EQUIPMENT SO AS TO BE COMPLETELY FREE OF VIBRATION UNDER CONDITIONS OFOPERATION. FLEXIBLE CONNECTORS SHALL BE USED WHEN CONNECTING TO ANY VIBRATING EQUIPMENT.17.UPON COMPLETION OF THE INSTALLATION, CONTRACTOR SHALL COMPLETELY BALANCE ALL MECHANICAL SYSTEMS. ALL SUPPLY EXHAUSTFANS SHALL BE TESTED AND ADJUSTED TO OBTAIN THE DESIRED AIR QUANTITIES. ALL AIR SUPPLY OUTLETS, RETURN AND EXHAUSTGRILLES, FRESH AIR INTAKES AND LOUVERS SHALL BE BALANCED UNTIL EACH DELIVERS SUBSTANTIALLY ITS SPECIFIED AMOUNT, BUT NOMORE THAN 10% OF DESIGN. AIR BALANCE OF ALL SYSTEMS SHALL BE ACCOMPLISHED WITH THE RESPECTIVE EQUIPMENT UNDER FULLCOOLING CONDITIONS. SHEETZ WILL SCHEDULE A CERTIFIED BALANCING CONTRACTOR TO CHECK AND COMPARE CONTRACTORSREPORT.18.ALL MECHANICAL EQUIPMENT SHALL BEAR THE LABEL OF AN APPROVED AGENCY AND THAT THE MECHANICAL EQUIPMENT WILL BETESTED TO THE APPROPRIATE STANDARDS IN THE 2012 NORTH CAROLINA MECHANICAL CODE. CHAPTER 9 AND 11, AND THE RESULTSPROVIDED.19.ALL OUTSIDE AIR INTAKE OPENINGS WILL BE LOCATED A MINIMUM OF 15 FEET FROM ANY PLUMBING VENTS, AND 10 FEET FROM FUEL-FIREDAPPLIANCE VENTS OR EXHAUST FAN DISCHARGES.20.THE HVAC UNITS WILL EACH BE SUPPLIED WITH A FACTORY INSTALLED SMOKE DETECTION SYSTEM LOCATED IN THE AC UNITS RETURN AIRSECTION. THE SMOKE DETECTORS WILL BE LOCATED UPSTREAM OF FILTERS, EXHAUST AIR AND OUTDOOR AIR CONNECTORS. THE SMOKEDETECTORS WILL BE LABELED FOR INSTALLATION IN THE AIR DISTRIBUTION SYSTEM AND INSTALLED IN ACCORDANCE WITH NFPA 72.ACTIVATION OF THE SMOKE DETECTOR WILL SHUT DOWN THE HVAC UNITS AND ACTIVATE A VISIBLE AND AN AUDIBLE SIGNAL LOCATED ATTHE SALES COUNTER.21.ALL DUCTS SHALL BE SUPPORTED WITH APPROVED HANGERS AT INTERVALS NOT EXCEEDING TEN FEET (10') OR BY OTHER APPROVEDDUCT SUPPORT SYSTEMS DESIGNED IN ACCORDANCE WITH THE BUILDING CODES AND SMACNA REQUIREMENTS. MORE STRINGENT OF TWOSHALL BE FOLLOWED.22.ALL DUCT COVERINGS AND LININGS, INCLUDING ADHESIVES WHEN USED SHALL HAVE A FLAME SPREAD RATING NOT MORE THAN TWENTYFIVE (25) AND SMOKE DEVELOPMENT RATING NOT MORE THAN FIFTY (50), WHEN TESTED IN ACCORDANCE WITH ASTM-E-84.23.CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS WILL BE CONVEYED FROM THE DRAIN PAN OUTLET AND THE SECONDARYOR AUXILIARY OUTLET TO AN APPROVED LOCATION FOR DISPOSAL, SEE PLUMBING PLANS.24.PROVIDE STAND-OFF BRACKETS FOR VOLUME CONTROL DAMPERS.25.MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR EACH MECHANICAL APPLIANCE SHALL BE MADE AVAILABLE TO THE LOCAL FIELDINSPECTOR ON JOB SITE AT TIME OF INSPECTION.26.PRIOR TO WRAPPING THE DUCTWORK WITH INSULATION ALL RELATED CODE INSPECTIONS MUST BE COMPLETED AND APPROVED BY THEINSPECTOR HAVING JURISDICTION.27.PROVIDE 3-RING BINDER FOR THE OPERATING AND MAINTENANCE MANUAL OF HVAC EQUIPMENT CUT SHEETS OF CONTRACTOR ANDOWNER FURNISHED EQUIPMENT. THE MANUAL SHALL INCLUDE THE FOLLOWING·EQUIPMENT CUT SHEET/SUBMITTAL DATA HIGHLIGHTED SHOWING MODEL NUMBER,CAPACITY (INPUT/OUTPUT) AND OPTIONS FURNISHED.●MANUFACTURER OPERATION AND MAINTENANCE MANUAL. IDENTIFY REQUIRED MAINTENANCE ACTIONS.●NAME AND ADDRESS OF SERVICING AGENCY.●HVAC CONTROL SYSTEM MAINTENANCE AND CALIBRATION INFORMATION. (WIRING DIAGRAMS, SCHEMATICS, CONTROL SEQUENCESDESCRIPTIONS)●CLEARLY INDICATED FIELD DETERMINED SET POINT●SYSTEM NARRATIVE ON INTENDED OPERATIONS●NAME AND ADDRESS OF CONTRACTOR, SUBCONTRACTORS, EQUIPMENT SUPPLIERS, AND DESIGN ENGINEER (H.F. LENZ COMPANY)●TEST AND BALANCE REPORT.28. CONTRACTOR SHALL IN THE PRESENCE OF THE ENGINEER OF RECORD DEMONSTRATE EQUIPMENT OPERATIONS, SYSTEM TO SYSTEM INTERFACING RELATIONSHIPS, AND DEMONSTRATE CONTROL OPERATIONS AS REQUIRED BY CODE.29. contractor shall conduct, in the presence of the local code enforcement officer, a performance test of the ventilation system serving the commercial cooking appliance as per ncmc 5.07.16. the contractor shall furnishall necessary testing equipment and devices to perform the tests.30. lennox rooftop AC unit cooling coil drain pan shall be provided with float switch that will shut down the ac unit upon activation when a condensate overflow condition occurs as per NCMC 307.2.3.131. Appedix 5 from the energy code will be required at end of the project and a copy of the balance report SHALL BE submitted TO AUTHORITY HAVING JURISDICTION prior to certificate of occupancy.MECHANICAL EQUIPMENT SCHEDULEAC-1AIR CONDITIONER GAS HEATYORK PREDATOR ZR150N24R2B5HFA1A1 PACKAGED ROOFTOP UNIT OR APPROVED EQUAL, 168,700 BTUH GROSS TOTAL COOLING @95 AMBIENT, 4800 CFM @ 1.3"ESP, 700 CFM OA MIN, GAS ALUMINIZED STEEL HEAT EXCHANGER, TWO STAGE BURNER 240,000 INPUTBTUH, 192,000 OUTPUT BTUH, 5 HP EVAPORATOR MOTOR WITH INTELLISPEED CONTROL, 72.8 MCA, 208V/3 PH/60 HZ. PROVIDE 14"HIGH UNINSULATED FULL PERIMETER ROOF CURB, OUTDOOR AIR HOOD, SIMPLICITY SE CONTROLLER TEMPERATURE SENSORS,MODULATING ECONOMIZER DAMPERS W/ ENTHALPY CONTROL INCLUDING SENSORS, MAGNADRY RELATIVE HUMIDITY CONTROL, LOWAMBIENT CONTROL, NON-POWERED GFCI SERVICE OUTLET, FACTORY INSTALLED DISCONNECT, CONDENSATE DRAIN PAN OVERFLOWSWITCH TO SHUT DOWN UNIT, SMOKE DETECTOR IN RA SECTION.AC-2AIR CONDITIONER GAS HEATYORK PREDATOR ZR090N12R2B5HFA1A1 PACKAGED ROOFTOP UNIT OR APPROVED EQUAL, 93,000 BTUH GROSS TOTAL COOLING @95 AMBIENT, 3000 CFM @ 1.3"ESP, 400 CFM OA MIN, GAS FIRED ALUMINIZED STEEL HEAT EXCHANGER, TWO STAGE BURNER 120,000INPUT BTUH, 96,000 OUTPUT BTUH, 3 HP EVAPORATOR MOTOR WITH INTELLISPEED CONTROL, 43.3 MCA, 208V/3 PH/60 HZ. PROVIDE14" HIGH UNINSULATED FULL PERIMETER ROOF CURB, OUTDOOR AIR HOOD, SIMPLICITY SE CONTROLLER TEMPERATURE SENSORS,MODULATING ECONOMIZER DAMPERS W/ ENTHALPY CONTROL INCLUDING SENSORS, MAGNADRY RELATIVE HUMIDITY CONTROL, LOWAMBIENT CONTROL, NON-POWERED GFCI SERVICE OUTLET, FACTORY INSTALLED DISCONNECT, CONDENSATE DRAIN PAN OVERFLOWSWITCH TO SHUT DOWN UNIT, SMOKE DETECTOR IN RA SECTION.AC-3AIR CONDITIONER GAS HEATYORK PREDATOR ZR090N12R2B5HFA1A1 PACKAGED ROOFTOP UNIT OR APPROVED EQUAL, 93,000 BTUH GROSS TOTAL COOLING @95 AMBIENT, 3000 CFM @ 1.3"ESP, 400 CFM OA MIN, GAS FIRED ALUMINIZED STEEL HEAT EXCHANGER, TWO STAGE BURNER 120,000INPUT BTUH, 96,000 OUTPUT BTUH, 3 HP EVAPORATOR MOTOR WITH INTELLISPEED CONTROL, 43.3 MCA, 208V/3 PH/60 HZ. PROVIDE14" HIGH UNINSULATED FULL PERIMETER ROOF CURB, OUTDOOR AIR HOOD, SIMPLICITY SE CONTROLLER TEMPERATURE SENSORS,MODULATING ECONOMIZER DAMPERS W/ ENTHALPY CONTROL INCLUDING SENSORS, MAGNADRY RELATIVE HUMIDITY CONTROL, LOWAMBIENT CONTROL, NON-POWERED GFCI SERVICE OUTLET, FACTORY INSTALLED DISCONNECT, CONDENSATE DRAIN PAN OVERFLOWSWITCH TO SHUT DOWN UNIT, SMOKE DETECTOR IN RA SECTION.EF-1EXHAUST FANGREENHECK CUE-121-VG UPBLAST ROOF FAN, 780 CFM @ 0.375" ESP, 1/4 HP, 120V/1 PH/60 HZ, VARI-GREEN DIRECT DRIVE ECm WITHPOTENTIOMETER DIAL SWITCH, NEMA-A TOGGLE DISCONNECT TO BE FIELD INSTALLED, BACKWARD INCLINED ALUMINUM CENTRIFUGALFAN WHEEL, ALUMINUM HOUSING, ALUMINUM CURB CAP WITH PRE-PUNCHED MOUNTING HOLES, DRAIN TROUGH, PROVIDEPRE-FABRICATED ROOF CURB WITH FAN.EF-2EXHAUST FANNOT USED.EF-3EXHAUST FANNOT USED.EF-4HOOD & EXHAUST FANCAPTIVE-AIRE 37" BACKSHELF STAINLESS STEEL HOOD MODEL 3044 AM-BD-2-BR (THIS HOOD IS TESTED PER UL 710 AND MEETS ITSREQUIREMENTS), EXHAUST FAN - MODEL DU50HFA, 694 CFM @ (FRYER) 1/2 HP, 208 V, 1 PHASE, 60 HZ, DIRECT DRIVE W/ ECM,CENTRIFUGAL BLOWER, ALUMINUM HOUSING, MOTOR MOUNTED ON VIBRATION ISOLATORS, WITH FACTORY INSTALLED DISCONNECTSWITCH, PREFABRICATED ROOF CURB, ALL DUCTWORK BEYOND THE EXHAUST DUCT COLLAR TO BE PROVIDED AND INSTALLED INACCORDANCE WITH THE JURISDICTIONAL CODES, AND MUST BE MECHANICALLY STRONG AND GREASE AND WATERTIGHT BLOWERSHALL BE NON-OVERLOADING TYPE, THE BLOWER WHEEL SHALL BE FORWARD CURVED CENTRIFUGAL, CONSTRUCTED G-90GALVANIZED STEEL DESIGN WHICH WILL DELIVER THE SPECIFIED VOLUME OF AIR AT THE REQUIRED STATIC PRESSURE, TOPHORIZONTAL DISCHARGE IS DESIRED. FAN SHALL BE INTERLOCKED TO EF-4M SUPPLY FAN VIA CAPTIVE AIRE CONTROL PANEL.EF-4MMAKE-UP AIR SUPPLY FAN GAS HEATCAPTIVE - AIRE MAKE-UP AIR SUPPLY FAN MODEL D76, 625 CFM @ 0.4" ESP, 1.0 hp direct drive ecm, 1634 RPM, LOW CFM DIRECTFIRED GAS WITH 43951 BTUH INPUT, 40435 BTUH OUTPUT, 0 DEGREE F EAT WITH A 60 DEGREE F TEMPERATURE RISE, GAS INLETPRESSURE 7 - 14 INCHES OF WC, FLA 6.1 AMPS 208 V, 1 PHASE, 60 HZ ROOF TOP MODULAR DOWN DISCHARGE WITH SCREENEDINTAKE HOOD, SIDE ACCESS FILTER SECTION WITH (1) 16"X20"X2" EZ KLEEN METAL MESH FILTER, PRE-FABRICATED ROOF CURB ANDSUPPORT LEG. PROVIDE COOLING INTERLOCK RELAY, 24 VAC COIL 120V CONTACT TO LOCK OUT BURNER CIRCUIT WHEN AC INENERGIZED ALL DUCTWORK BEYOND THE VENTILATOR DUCT COLLAR TO BE FURNISHED AND INSTALLED IN ACCORDANCE WITH THEJURISDICTIONAL CODES. FAN SHALL BE INTERLOCKED TO EF-4 EXHAUST FAN VIA CAPTIVE AIRE CONTROL PANEL.EF-5HOOD & EXHAUST FANCAPTIVE-AIRE STAINLESS STEEL HOOD MODEL 4218 VH1-PYRAMID, EXHAUST FAN MODEL DU33HFA, ROOF TOP EXHAUST 450 CFM @(TURBO CHEF OVEN) 0.33 HP direct drive ecm, 115V, 1 PHASE, 60 HZ, CENTRIFUGAL BLOWER, ALUMINUM HOUSING, MOTOR MOUNTEDON VIBRATION ISOLATORS, WITH FACTORY INSTALLED DISCONNECT SWITCH. install PRE-FABRICATED ROOF CURB, INSECT SCREEN.INSTALL PRE-WIRED STAINLESS STEEL CONTROL BOX WITH LIGHTED SWITCH ON WALL, FURNISHED BY OWNERCD-1CEILING DIFFUSERCEILING DIFFUSER METALAIRE MODEL 5700, 24"X24" SQUARE FACE, 2 CONE, ROUND NECK, CONSTRUCTED OF STEEL, STANDARD WHITEFINISH, LAY-IN MOUNTING, 4-WAY THROW, PROVIDE DIRECTIONAL BAFFLES WHEN THE DIFFUSER FACE IS WITHIN 2'-0" OF ANOBSTRUCTION. SUPPLY DIFFUSER BACK PAN SHALL BE FIELD INSULATED USING R-6 FIBERGLASS INSULATION BLANKET WITH VAPORBARRIER. WHEN INSTALLED IN GYP CEILING, PROVIDE APPROVED PLASTER FRAME ACCESSORYRCD-1RADIAL CEILING DIFFUSERMETALAIRE MODEL HRD-CL-AL DIFFUSER, SIZE AS INDICATED ON DRAWING, ROUND NECK, SHALL INCLUDE AN UPPER AND LOWERPRESSURE CHAMBER AND SHALL GENERATE A 180°, TWO WAY, LOW VELOCITY DISCHARGE PATTERN, LAY-IN MOUNTING, STANDARDWHITE FINISH, ONE-PIECE PERFORATED ALUMINUM FACE AND CORE ASSEMBLY THAT IS REMOVABLE FROM THE ALUMINUM BACK PANWITH 1/4" TURN FASTENERS, 51% FREE AREA PERFORATED FACE SHALL INCLUDE (2) STAINLESS STEEL SAFETY CHAINS ATTACHING THEFACE ASSEMBLY TO THE BACK PAN. SUPPLY DIFFUSER BACK PAN SHALL BE FIELD INSULATED USING R-6 FIBERGLASS INSULATIONBLANKET WITH VAPOR BARRIER.RG-1RETURN GRILLEMETALAIRE MODEL SRH, 24"X24" MODULE SQUARE FACE WITH 22"X22" NECK, LAY-IN MOUNTING, STEEL CONSTRUCTION WITH SINGLE SETOF 45° FIXED DEFLECTOR BLADES, LOUVER FACE, DEFLECTOR BLADES SHALL BE .666" ON CENTER, STANDARD WHITE FINISH. WHENINSTALLED IN GYP CEILING, PROVIDE APPROVED PLASTER FRAME ACCESSORY. CONTRACTOR SHALL PROVIDE A FIELDFABRICATED SQUARE TO ROUND INLET COLLAR, SIZE AS INDICATED ON DRAWINGS.EG-1EXHAUST GRILLEMETALAIRE MODEL CC5, 1/2"X1/2"X1/2" CUBE CORE, LAY-IN MOUNTING, ALUMINUM EXTRUDED BORDER CONSTRUCTION WITH ALUMINUMCUBED CORE, STANDARD WHITE FINISH, SIZE AS INDICATED ON DRAWINGS. WHEN INSTALLED IN GYP CEILING PROVIDE APPROVEDPLASTER FRAME ACCESSORY.TGCTRANSFER AIR GRILLEMETALAIRE MODEL CC5, 1/2"X1/2"X1/2" CUBE CORE, LAY-IN MOUNTING, ALUMINUM EXTRUDED BORDER CONSTRUCTION WITH ALUMINUMCUBED CORE, STANDARD WHITE FINISH, SIZE AS INDICATED ON DRAWINGS. WHEN INSTALLED IN GYP CEILING PROVIDE APPROVEDPLASTER FRAME ACCESSORY.VCD VOLUME CONTROL DAMPERSGREENHECK VOLUME CONTROL DAMPER MODEL MBDR-50 OR RUSKIN MODEL MDRS25 FOR ROUND DAMPERS, GREENHECK MODELMBD-10 OR RUSKIN MODEL MD25 FOR RECTANGULAR DAMPERS. DAMPERS SHALL BE FACTORY FABRICATED SINGLE BLADE,CENTER PIVOTED WITH SQUARE AXLE SHAFT AND LOCKING HAND QUADRANT, FRAME AND BLADE SHALL BE CONSTRUCTED OFMINIMUM 20 GAUGE GALVANIZED SHEET STEEL, PROVIDE OPTIONAL 2" HAND QUADRANT STAND OFF BRACKET.VCD-RVOLUME CONTROL DAMPER REMOTEMETROPOLITAN AIR TECHNOLOGY MODEL RT-250 SINGLE BLADE DAMPER & RT-WGA UNIVERSAL DAMPER DRIVE SYSTEM - WITHRT-CCM MINIATURE CEILING CUP WITH 1" DIAMETER NYLON CAP. THE DAMPER SHALL BE SAME SIZE AS DUCTWORK INDICATED ON THEFLOOR PLAN. THE DAMPER ASSEMBLY WILL INCLUDE STANDARD CABLE 24" IN LENGTH, CUSTOM LENGTHS ARE AVAILABLE UP TO 60FEET DEPENDING ON TERMINATION POINT. THE CABLE SHALL BE SECURED WITH CLAMPS EVERY 3'-0" MINIMUM, CABLE TURN RADIUSSHALL NOT EXCEED 4" RADIUS. SECURE THE CEILING CUP MOUNTING BRACKET TO CEILING FRAMING CONSTRUCTION AND NOT THECEILING. THE DAMPER CAN BE ADJUSTED USING A STANDARD HEX NUT DRIVER. TTHERMOSTATHONEYWELL MODEL T-7300D SERIES 2000 COMMERCIAL MICROELECTRONIC COOLING/HEATING 24V THERMOSTAT, AUTOMATIC ORMANUAL CHANGE OVER FOR MULTI-STAGE SYSTEMS, BUILT IN TIME DELAYS, LCD READOUT WITH SET POINT TEMPERATURE AND ACTUALTEMPERATURE IN F PLUS SYSTEM STATUS AND OPERATIONAL MODE, FAN BUTTON TO ALLOW CONTINUOUS (ON) OR INTERMITTENT (AUTO)BLOWER SETTING, KEYBOARD LOCKOUT TO PREVENT TAMPERING, SOLID-STATE ELECTRONIC TECHNOLOGY TO ELIMINATE BATTERYBACK-UP AND MAINTAINS THERMOSTAT SETTINGS DURING POWER FAILURE. TO BE LOCATED IN THE OFFICE. FURNISHED BY OWNER.CONTRACTOR TO INSTALL AND FIELD WIRE.RTSREMOTE TEMPERATURE SENSORAIR SENSOR MODEL 27C.40 LOCATE AND CONNECT TO APPROPRIATE THERMOSTAT AS SHOWN ON THE PLANS. REMOTETEMPERATURE SENSORS TO MONITOR AND CONTROL HEATING AND COOLING UNITS. FURNISHED BY OWNER. CONTRACTOR TO INSTALLAND FIELD WIRE. HSHumidity SENSORRELATIVE HUMIDITY SENSOR provided with ac unit. LOCATE AND CONNECT TO APPROPRIATE HVAC UNIT AS SHOWN ON THE PLANS.HUMidity SENSOR TO MONITOR HUMIDITY AND CONTROL AC UNITS CONDENSER REHEAT FOR magnadry. ADJUST UNIT SETPOINT TOINITIATE FUNCTION WHENEVER THE SPACE HUMIDITY SENSOR READS 40%RH OR GREATER. FURNISHED BY OWNER. CONTRACTOR TOinstall AND FIELD WIRE.(FRYER) TYPE 1MECHANICAL EQUIPMENT PROCUREMENT AND INSTALLATION SCHEDULEMECHANICAL EQUIPMENTFURNISHED BYINSTALLED BYAC-1 - AIR CONDITIONER GAS HEATOWNERMECHANICAL CONTRACTORAC-2 - AIR CONDITIONER GAS HEATOWNERMECHANICAL CONTRACTOREF-1 - EXHAUST FANEF-2 - EXHAUST FANEF-3 - EXHAUST FANEF-4 - EXHAUST FANOWNERMECHANICAL CONTRACTOREF-4M - MAKE UP FAN GAS HEATOWNERMECHANICAL CONTRACTORCD-1 - CEILING DIFFUSERAUDIBLE / VISIBLERG-1 - RETURN GRILLEEG-1 - EXHAUST GRILLET - THERMOSTATOWNERMECHANICAL CONTRACTORRTS - REMOTE TEMPERATURE SENSOROWNERMECHANICAL CONTRACTORMECHANICAL CONTRACTORMECHANICAL CONTRACTORMECHANICAL CONTRACTORMECHANICAL CONTRACTORnot usednot usedMECHANICAL CONTRACTORMECHANICAL CONTRACTORMECHANICAL CONTRACTOROWNERMECHANICAL CONTRACTORnot usednot usedMECHANICAL CONTRACTORHS - HUMIDITy SENSOROWNERMECHANICAL CONTRACTORTGC - TRANSFER GRILLE CEILINGMECHANICAL CONTRACTORMECHANICAL CONTRACTORAC-3 - AIR CONDITIONER GAS HEATOWNERMECHANICAL CONTRACTORRCD-1 - RADIAL CEILING DIFFUSERMECHANICAL CONTRACTORMECHANICAL CONTRACTOREF-5 - EXHAUST FANOWNERMECHANICAL CONTRACTORvcd-R - VOLUME CONTROL DAMPER REMOTE mechanical contractorMECHANICAL CONTRACTORvcd - VOLUME CONTROL DAMPER mechanical contractorMECHANICAL CONTRACTORAS NOTEDNJB4772-R-M1M-1MECHANICAL NOTES 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R T H CAROLINAPR OFESSIONALENGINEER DAVID J. ANDER SON SEAL04300512-21-17 AIR BALANCE SCHEDULEAC-1AC-2EF-1EF-2EF-3EF-4UNITOUTSIDE AIR800500----625RETURN AIR40002500------SUPPLY AIR48003000----625EXHAUST AIR----580--694--PRESSURE+700+400-580---69--TOTAL+401------AC-350025003000--+400TO UNITSTO UNITSFR UNITSOUT OF BLDGBUILDINGEF-5------450-450OUTDOOR VENTILATION CALCULATIONSWORK ROOM:4 PERSONS x 15 CFM/PERSON= 60 CFMRETAIL AREA:1300 S.F. / 1000 x 15 = 2020 x 7.5 CFM/PERSON = 150+ .12 CFM/SQUARE FOOT = 156= 306 CFMCHECK OUT AREA:465 S.F. / 1000 x 15 = 77 x 7.5 CFM/PERSON = 53+ .12 CFM/SQUARE FOOT = 56= 109 CFMOFFICE:65 S.F. / 1000 x 5 = .31 x 5 CFM/PERSON = 5+ .06 CFM/SQUARE FOOT = 5= 10 CFMSEATING AREA:360 S.F. / 1000 x 70 = 2525 x 7.5 CFM/PERSON = 187+ .18 CFM/SQUARE FOOT = 54= 241 CFMTOTAL OUTSIDE AIR REQUIRED726 CFMTOTAL OUTSIDE AIR PROVIDED1500 CFMMECHANICAL PLANSCALE: 1/4" = 1'-0"18x8 GREASE DUCT FR FIELD CUT OPENING INHOOD AND STRAIGHT UP WITH TRANS TO EF-4ON ROOF ABV 694 CFM. WRAP GREASEDUCTWORK WITH 0 CLEARANCE DUCT WRAP ASMANUFACTURED BY THERMAL CERAMICSSUITABLE FOR GREASE DUCT APPLICATIONS.2KEYNOTES:3410" DIAMETER EXHAUST DUCT FROM CONNECTIONON TURBO CHEF TYPE 11 HOOD, EXTEND ANDROUTE DUCTWORK UP THRU ROOF WITH TRANSITIONTO EF-5 ABOVE 450 CFM.5612x10 SA DUCT W/ TRANS FR MAKE-UPAIR UNIT EF-4M ON ROOF ABV 625 CFM3x24 SA CONN TO HOOD W/ BOOT CONNFR 6x24 SA DUCT.712x8 TRANSFER AIR DUCT W/ 10x10 TGC24x18 RA DUCT W/ TRANS INSIDE ROOF CURB TOAC-2 UNIT RA CONN OPNG ABV 2600 CFM20x20 SA DUCT W/ TRANS INSIDE ROOF CURB FRAC-2 UNIT SA CONN ON ROOF ABV 3000 CFM8924x22 RA DUCT W/ eccentric TRANS in vert toa 28X18 ra duct thru roof then trans INSIDEROOF CURB TO AC-1 RA CONN 3900 CFM20x28 SA DUCT W/ TRANS INSIDE ROOF CURB FRAC-1 UNIT SA CONN ON ROOF ABV 4800 CFM10the ceiling terminal unit shall be painted withSherwin Williams semi-gloss color sw106 kilmbeige.11RG-1 14" USE AS TRANSFER AIR GRILLE CONNECTW/ 12x6 TRANSFER AIR DUCTWORK THE TRANSFERDUCTWORK SHALL BE ROUTED BETWEEN THE STUDOPENINGS.12NOTES:1.A PERMANENT APPROVED LADDER ACCESS TO THE ROOF FOR SERVICINGTHE ROOF TOP UNITS IS PROVIDED AT THE EXTERIOR WALL OF THE STORE.2.A ONE-HUNDRED TWENTY (120) VOLT GFCI RECEPTACLE WILL BE INSTALLEDFOR SERVICING THE ROOF TOP H.V.A.C. AND REFRIGERATION EQUIPMENT. THERECEPTACLE SHALL BE LOCATED ON THE ROOF LEVEL AND WITHINTWENTY-FIVE FEET (25') OF THE EQUIPMENT.3.REFER TO "STORE PLC CONTROL SYSTEM" SHOP DRAWINGS BY ENERTECHASSOCIATES FOR PLACEMENT OF ADDITIONAL SENSORS AT "RTS" LOCATIONSIN RETURN AIR DUCTWORK.14∅ exhaust air ductwork up thru roof withtransition to ef-1 above 580 cfm.13the supply air ductwork shall be installedbetween the 34" on center truss's. theductwork shall be sloped with the truss'ssuch that the branch supply air diametertake off ductwork connections will becentered in the main ductwork. the branchductwork shall be routed thru the trusswebbing. (typical for all supply ductworkfrom ac-1, ac-2 and ac-3)1415WALK-INCOOLERWALK-INFREEZERTAKE-HOMECOOLER8'-4"SALESAREA 210'-0"KITCHEN11'-0"10'-0"CHECK STAND9'-6"WALK-INTAKE-OUTCOOLERSEATING AREA11'-0"VESTIBULE11'-8"9'-6"UTILITY ROOM9'-6"MEN9'-6"WOMEN8'-0"SALES AREA 18'-0"7'-8"8'-0"10'-0"up8'-0"EMPLOYEEUTILITY SPACE9'-6'work room8'-0"officeUNIT SELF-FLASHESOVER CURBINCLUDE A FACTORYPROVIDED HINGEDSUB-BASE andvented curbIF GREASE DUCT CANNOT GOSTRAIGHT UP, OBTAIN OWNERSAPPROVAL TO USE RADIUSOFFSETS (MAXIMUM OF 20°) IN THEVERTICAL AS ILLUSTRATED ANDDESCRIBED ABOVE. NOTE:HORIZONTAL RUNS ARE NOTPERMITTED.TYPE I EXHAUST DUCTWORK INSTALLATIONNOTES:1.DUCTWORK SHALL BE CONSTRUCTEDOF STEEL HAVING A MINIMUMTHICKNESS OF 0.0575" (16 GAGE) ORSTAINLESS STEEL NOT LESS THAN0.0450" (18 GAGE) THICKNESS.2.DUCT JOINTS SHALL BE BUTT JOINTS ORWELDED FLANGE JOINTS WITH AMAXIMUM FLANGE DEPTH OF 0.5".3.joints, seams, and penetrations ofgrease ducts shall be made witha continuous liquied-tight weld orbraze made on the externalsurface of the duct system.4.DUCTWORK SHALL BE INSTALLEDVERTICALLY WITH NO OFFSETS,HORIZONTAL DUCTWORK IS NOTPERMITTED.5.IF OFFSETS ARE REQUIRED ANDAPPROVED BY OWNER, THE OFFSETSSHALL BE RADIUS WITH A MAXIMUM OF20° IN THE VERTICAL AS ILLUSTRATED.6.DUCTWORK SHALL BE INSULATED WITH0 CLEARANCE FIRE WRAP INSULATION.7.PRIOR TO THE USE OR CONCEALMENTOF ANY PORTION OF THE GREASEDUCT SYSTEM, A LEAKAGE TEST SHALLBE PERFORMED. A LIGHT TEST SHALLBE PERFORMED TO DETERMINE THATALL WELDED AND BRAZED JOINTS ARELIQUID TIGHT.8.BRACING AND SUPPORTS SHALL BENONCOMBUSTIBLE, SECURELYATTACHED TO THE STRUCTURE ANDDESIGNED TO CARRY GRAVITY ANDSEISMIC LOADS WITHIN THE STRESSLIMITATIONS OF THE BUILDINGSTRUCTURE. BOLTS, SCREWS, RIVETS,AND OTHER MECHANICAL FASTENERSSHALL NOT PENETRATE THE DUCTWALLS.TYPE I MAKE-UP SUPPLY DUCTWORKINSTALLATION NOTES:1.FLEXIBLE DUCTWORK IS NOTPERMITTED2.RADIUS ELBOWS SHALL BE USED;MITERED ELBOWS ARE PROHIBITED.3.ALLOW MINIMUM 18" FROM HOODCONNECTION TO ELBOW.4.DO NOT CONNECT ELBOW DIRECTLY TOFAN OUTLET.rear discharge(back supply)EXHAUST FAN DISCHARGE SHALLTERMINATE A MINIMUM OF 40"ABOVE THE ROOF LINEef-4m make-upair unit with heatTHE final 18" OF supply AIRDUCTWORK SHALL BE INSULATEDwith 0 CLEARANCE FIRE WRAPINSULATIONsupplyair ductfield cutpenetrationwithin this area4'-2"RTS20x20 14∅EF-4M ONROOF ABVRTSRTS16∅16∅16∅16∅16∅22x2220x20 12∅12∅ 24x2228x1428x14 16∅20x28 CD-1 8"130 CFMCD-1 8"150 CFM10∅10∅8∅8∅12∅10∅12∅20x28 12∅12∅12∅18x20 12∅12∅CD-1 12"440 CFMCD-1 12"440 CFMCD-1 12"440 CFMCD-1 12"440 CFMCD-1 12"440 CFMCD-1 12"440 CFMCD-1 12"440 CFMCD-1 12"440 CFMRG-1 16"900 CFMRG-2 16"1000 CFMCD-1 10"250 CFMCD-1 10"250 CFMCD-1 10"250 CFMCD-1 6"50 CFMCD-1 8"175 CFMTTTAC-1AC-2AC-38∅CD-1 6"100 CFMCD-1 12"385 CFMCD-1 12"385 CFMCD-1 12"385 CFMCD-1 12"385 CFMCD-1 12"385 CFM18x1812∅12∅12∅12∅6∅RG-1 8"160 CFMRG-1 12"320 CFMRG-1 12"320 CFM14∅8∅24x1824x12 RG-1 16"760 CFMEG-1 12"x12"250 CFM12x8 HSAC-2AVHSAC-3AVHSAC-1AV16x24GREASE HOODTYPE 1 MOUNTTOP @ 85" AFF(FIELD VERIFY)EF-4 ONROOFABOVEEF-5 ONROOFABOVETURBO CHEF HOODTYPE 11 MTD BTM6'-6" AFF254612x8 6232478910AC-1 UNIT ONROOF ABOVEAC-2 UNIT ONROOF ABOVEAC-3 UNIT ONROOF ABOVERCD-1 12"600 CFMRCD-1 12"600 CFMRCD-1 12"600 CFMRCD-1 12"600 CFMRCD-1 12"600 CFM10Ø12∅12∅CD-2 12"500 CFMCD-2 12"500 CFM12∅ 12∅12∅12∅1112x16 1212x1616x1216x1212∅12x108x8 EG-180 CFM12∅12∅14∅14∅131414141416∅rise12∅EG-1 12"x12"250 CFM8∅dropRG-2 16"1000 CFM11EF-1 ONROOFABOVE14∅12∅16∅16∅ 12∅12∅20x8RG-1 16"760 CFM16∅8.531.861.641.721.728.121.60RG - 1 1 6 " 8 6 5 C FM R G - 1 1 6 " 8 6 5 C F M R G - 1 1 6 " 8 7 0 C F M7/8"rs & 3/8"rl refrigerant piping from 8.12AcondensING unit on roof above and connect to8.12 ice machine.16167/8"rs & 3/8"rl refrigerant piping from 1.51condensing unit on roof above and connect to 1.60evaporator in walk in beer cooler. provideapproved sealant at piping penetrations thrucooler panels.1717181-1/8"rs & 1/2"rl refrigerant piping from 1.52condensing unit on roof above and down intocooler, tap (2) 7/8"RS taps from the 1-1/8"RS riser& (2) 3/8"Rl taps from the 1/2"rl riser, extendbranch refrigerant piping along the coolersrear wall and connect to the 1.72 evaporatorindicated. provide approved sealant at pipingpenetrations thru cooler panels.18197/8"rs & 3/8"rl refrigerant piping from 1.55condensing unit on roof above and connect to 1.64evaporator in walk in cooler. provideapproved sealant at piping penetrations thrucooler panels.1920207/8"rs & 3/8"rl refrigerant piping from 1.53condensing unit on roof above and connect to 1.86evaporator in walk in freezer. provideapproved sealant at piping penetrations thrucooler panels.20217/8"rs & 3/8"rl refrigerant piping from 8.53Acondensing unit on roof above and connect to8.53 ice machine.217/8"rs &3/8"rl7/8"rs &3/8"rlrefrigerant piping shown horizontally is withinthe cooler's / freezer's interior222222227/8"rs &3/8"rl227/8"rs &3/8"rl7/8"rs &3/8"rl7/8"rs &3/8"rl227/8"rs &3/8"rl14'-1012"DIMENSION LINE TO TURBO CHEF HOOD IS BASED FROMTHE CENTER LINE OF THIS COLUMN.233HUMIDITY SENSOR FIELD WIRING DIAGRAMSNOT TO SCALEnOTE:THE WALL HUMIDITY DIAGRAMS INDICATED REFERENCE YORK MANUAL1063783-UAI-J-1116, REFER TO THIS MANUAL FOR ADDITIONAL INFORMATION.Notes:1.switch 1 to Off, switch 2 to on.ensure dip switch setting are asshown in figure 1.2.locate the wiring harness within thereturn section of the unit.·388/R: PORT 5 (24V PWR) ON SENSORTO 24VAC ON UNIT CONTROL BOARD·362/W: PORT 9 (OUT) ON SENSOR TO(RAH+) ON THE UNIT CONTROL BOARD.·364/BK: PORT 6 (COM) ON SENSOR TOCOM ON ECONOMIZER CONTROL BOARD.3.MOUNT SENSOR IN THE RETURN AIRDUCTWORK.24x2224x18 RA DUCT W/ eccentric TRANS in vert to a24X18 ra duct thru roof then trans INSIDE ROOFCURB TO AC-3 RA CONN OPNG ABV 2600 CFM2420x20 SA DUCT W/ TRANS INSIDE ROOF CURB FRAC-3 UNIT SA CONN ON ROOF ABV 3000 CFM24x18 1 2 ∅12∅12∅ 12∅12∅12∅3"8∅14x1414x1412∅12∅12∅10∅10∅ 8∅ 10∅10∅12∅14∅ 6∅6∅6∅1510X10 tgc to be used for return air, balanceto 80 cfm20x812∅12∅12∅12∅vcd-r is a gear driven cable operatedvolume control damper with a mini ceilingmounted cup and cover plate. locate remotevcd-r adjuster near its associated airterminal for identification purposes. secureadjuster to ceiling framing.2525252525AS NOTEDNJB4772-R-M2M-2MECHANICAL PLAN 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR OFESSIONALENGINEER DAVID J. ANDER SON SEAL04300512-21-17 MEP ROOF PLAN11" CDL DRAIN PIPING AND TRAP ASSEMBLY.2TERMINATE FLUE 6'-0" ABOVE ROOF.3REFER TO DRAWINGS E-3, E-4 & E-7 FOR POWER CONNECTION OF FAN MOTOR.KEY NOTES ELSEWHERE THIS DRAWING:TERMINATE VENT 6'-0" ABOVE ROOF LEVEL.4TERMINATE VENT 2'-0" ABOVE ROOF LEVEL.56REFER TO 'STORE PLC CONTROL SYSTEM' SHOP DRAWINGS BY ENERTECH ASSOCIATESFOR WIRING DIAGRAMS AND ADDITIONAL DETAILS AND INFORMATION.SCALE: 1/4" = 1'-0"ROOFROOF CURBROOF TOPUNITREDUCER(AS REQUIRED)RTU DRAIN CONN.4" TRAP SEAL (ORDEPTH AS REQ'D BYUNIT MFGR.)open teeADDITIONAL PLY OFROOFING MATERIAL,ADHERE TO ROOF1" PVC1" PVCSTOP PIPING1" ABV. ROOFCUT ON 45 DEGREE ANGLE.RTU CONDENSATE DRAIN PIPING DETAILVERIFY ROOF SLOPE AND LOCATE CONDENSATE DRAIN SO THE WATERDRAINS AWAY FROM THE UNIT ROOF CURB.tee w/cap1" above roofAIR HANDLING UNITGAS DIRT LEG CONNECTION DETAILNO SCALEMAXIMUM 12"NATURAL GAS PIPINGSIZE AS INDICATED ONDRAWINGUNIT CONNECTIONGAS VALVEPROVIDE GAS LINE SIZES AS INDICATED ON DRAWINGS AND tRANSITION TO EQUIPMENTCONNECTION SIZE AFTER ISOLATION VALVE AND WITHIN 12" OF EQUIPMENT.C.O. PLUGFOR CONTINUATIONREFER TO FLOOR PLANMinimum 3"FURNISHed by ownerCCCAC-1AC-2AC-3bacnetwiring(typ)6bacnet / plc wiring schematicNO SCALENO SCALEGENERAL NOTES:1.ALL OUTSIDE AIR INTAKE OPENINGS SHALL BE LOCATED A MINIMUM OF 15 FEET FROMANY PLUMBING VENTS AND 10 FEET FROM ANY FUEL-FIRED APPLIANCE VENTS OREXHAUST FAN DISCHARGES.2.PROVIDE GAS LINE SIZES AS INDICATED ON DRAWINGS AND TRANSITION TO EQUIPMENTCONNECTION SIZE AFTER ISOLATION VALVE AND WITHIN 12" OF EQUIPMENT.3.ALL REFRIGERANT PIPING AND ASSOCIATED ACCESSORIES SHALL BE INSULATED, ALLSEAMS AND JOINTS SEALED, WITH 1/2" THICK CLOSED-CELL, EPDM-BASED FLEXIBLEELASTOMERIC TUBULAR INSULATION COMPLYING WITH ASTM C524, TYPE I. MAXIMUMTHERMAL CONDUCTIVITY OF 0.27 BTU-IN./H-FT2- °F AT A 75°F MEAN TEMPERATUREWHEN TESTED IN ACCORDANCE WITH ASTM C 177 OR ASTM C 518, LATEST REVISIONS. 25/50 FLAME SPREAD AND SMOKE DEVELOPED RATING IN ACCORDANCE WITH ASTME84-91A. INSULATION SHALL BE INHERENTLY UV RESISTANT OR EXTERIOR APPLICATIONSSHALL INCLUDE ULTRAVIOLET-PROTECTIVE COATING, AS RECOMMENDED BY INSULATIONMANUFACTURER. PROVIDE AEROCEL (WHITE IN COLOR) INSULATION AS MANUFACTUREDBY AEROFLEX USA, INC. OR APPROVED EQUAL.4.NATURAL GAS PIPING, REFRIGERANT PIPING, AND ELECTRICAL CONDUITS INSTALLED ONROOF SHALL BE SUPPORTED WITH "CADDY PYRAMID ST FIXED STRUT SUPPORT,MODEL PSF10C." PROVIDE BANDS TO SECURE PIPING, 3/4-INCH-WIDE, ALUMINUM,0.007 INCH THICK. FOR REFRIGERATION PIPING, PROVIDE 4" LONG INSULATION SHIELDTO PROTECT INSULATION AT SUPPORT LOCATIONS. INSTALL PER MANUFACTURER'SRECOMMENDATIONS, APPROX. 8'-0" INTERVALS AND AT EACH TURN IN PIPING/CONDUIT.ducttransitionduct12"15"CURBEXHAUST FAN DUCTWORK CONNECTIONTRANSITION DETAIL for ef-4 & ef-5NO SCALE30"AC-112-1/2TONS24x32 ROOFOPNG REQ'DFOR SA DUCTSD30x20 ROOFOPNG REQ'DFOR RA DUCTFACTORYINSTALLEDH-34MDP-9GFIWPG1 1/2"G-PLUMBING CONTRACTORSHALL EXTEND AND CONNECTWITH VALVE TO UNIT AC-11 1/2"1AC-27-1/2TONS24x24 ROOF OPNGREQ'D FOR SA DUCT1SD26x20 ROOFOPNG REQ'DFOR RA DUCTFACTORYINSTALLEDH-34GFIGMDP-111 1/2"G-PLUMBINGCONTRACTOR SHALLEXTEND AND CONNECTWITH VALVE TO UNIT AC-21 1/2"1 1/2"DOWN TO 5.01CONTROL PANELDISCONNECTSUPPLIED W/ UNIT3/4"3/4"G-PLUMBINGCONTRACTOR SHALLEXTEND AND CONNECTWITH VALVE TO UNIT EF-4MAC-37-1/2TONS24x24 ROOFOPNG REQ'DFOR SA DUCT1SD26x20 ROOFOPNG REQ'DFOR RA DUCTFACTORYINSTALLEDH-34MDP-13GFI1 1/2"G 1 1/2"G-PLUMBING CONTRACTORSHALL EXTEND AND CONNECTWITH VALVE TO UNIT AC-3WPC6WPH-1,3,5WALK-IN COOLERCONDENSING UNIT208V-3PH-10.375A30A-3P-NF,240VWP30A-3P-NF,240VH-15,17,19WALK-IN FREEZERCONDENSING UNIT208V-3PH-14.375AWP30A-2P-NF,240VB-20,22ice cube dispenserCONDENSING UNIT208V-3PH-14.1AFLOW ARROWS IN FRONT OF CONDENSING UNITSINDICATE DIRECTION OF FAN DISCHARGE(TYPICAL FOR ALL CONDENSING UNITS)take home COOLERCONDENSING UNIT208V-3PH-26.5AH-2,4,660A-3P-NF,240VWPWALK-IN beer COOLERCONDENSING UNIT208V-3PH-12.875AWPH-29,31,3330A-3P-NF,240VD-29,31ICE MACHINECONDENSING UNIT208V-1PH-29.9A60A-2P-NF,240VROUTE/INSTALL REFRIGERANTPIPING ON ROOF WITHINDASHED AREA AS INDICATED.TYPICAL THIS PLAN. REFERTO GENERAL NOTES 3 & 4 FORADDITIONAL CRITERIA.REFRIGERANT PIPINGTO/FROM UNIT BELOW.TYPICAL THIS PLAN.EF-1WPSA-9SINGLE PHASE DISCSWITCH MTD IN FANSUPPLIED W/ UNITEF-515.5" x 15.5" ROOFOPNG REQ'DDOWN TO 5.15CONTROL PANELWPSC-283EF-416" x 16" ROOFOPNG REQ'D3DOWN TO 5.01CONTROL PANELWPDISCONNECTSUPPLIED W/ UNIT1.521.515.15 5.01b 5.01a1.538.53a1.553"VTR53"VTR43"VTR43"VTR54" WATER HEATERFLUE AND INTAKETHROUGH ROOF21"G-DOWN TOWATER HEATER1"G-DN TOFRYER2 1/2"2 1/2" G- FROMMETER/REGULATORSET LOCATED ON FACEOF BUILDING2 1/2"G-DOWN ONTO ROOF2 1/2"2 1/2"1" TO 3/4" REDUCER1"WP8.12A7refrigerant piping down thru roof in a method approved by the roofingmanufacturer. see drawing M-2 for continuation.7777777/8" RS &3/8" rl7/8" RS &3/8" rl7/8" RS &3/8" rl7/8" RS &3/8" rl7/8" RS &3/8" rl1-1/8" RS &1/2" rl1-1/8" RS &1/2" rl7/8" RS &3/8" rl7/8" RS &3/8" rl7/8" RS &3/8" rlto/from plc18 gageshielded wire3 conduCTORS,1 groundC6C61/8" npt test port- capped3"VTR53/4" UTW UP FRBLW TO ROOFHYDRANTRH-1MEP ROOF PLAN 1/4"=1'-0"NJB/WSP/RSM4772-R-MEP1MEP-12017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 1FIELD WRAPPER 43.00" High Front, Left, RightBACKSPLASH 28.00" High X 37.00" Long 304 SS HorizontalBACKSPLASH 90.00" High X 18.00" Long 304 SS VerticalBACKSPLASH 18.00" High X 37.00" Long 304 SS HorizontalBACKSPLASH 90.00" High X 18.00" Long 304 SS VerticalBACKSPLASH 96.00" High X 48.00" Long 304 SS VerticalBACKSPLASH 96.00" High X 48.00" Long 304 SS VerticalRIGHT QUARTER END PANEL 20" Top Width, 0" Bottom Width, 20" High 304 SSLEFT QUARTER END PANEL 20" Top Width, 0" Bottom Width, 20" High 304 SSHOODNO.ACCESSORIES3"24"Straight6240.091"HOODNO.WIDTHLENGTHTOTALSUPPLYCFMBOOT(S)WIDTHLENGTHANGLECFMS.P.1212242 LBS50 LBSCurbCurbRail19.500"W x 19.500"L x 30.000"H Vented Hinged19.500"W x 52.000"L x 24000"H Insulated4.000"W x 4.000"L x 36.000"HNO.ASSOC.FANUNIT NO.WEIGHTITEMSIZE2FIELD WRAPPER 31.50" High x 18.00" Long Front, Right, Back, Left 304 SS3442 LBSCurb19.500"W x 19.500"L x 30.000"H Hinged12FRYERTURBOCHEF3044AM-BD-2-BR4218VH1-Pyramid3' 1.00"3' 6.00"450 Deg.300 Deg.6944508"8"10"694450-0.566"-0.051"6240304 SS100%304 SS100%ALONEALONEALONEALONEHOODNO.TAGMODELLENGTHMAX.COOKINGTEMP.EXHAUST PLENUMTOTALEXH. CFMRISER(S)WIDTHLENG.DIA.CFMS.P.TOTALSUPPLYCFMHOODCONSTRUCTIONHOOD CONFIG.END TOENDROW12Captrate Solo Filter 85% Efficiency @ 7Micons (SEE SPEC THIS DWG)216"16"2-Screw In 12W LEDNO245 LBS18 LBSHOODNO.FILTER(S)TYPEQTY.HEIGHTLENGTHLIGHT(S)QTY.TYPEWIREGUARDHOODHANGINGWGHTN/AN/A1HEIGHT3'-1"4"4'-11"62413DU50HFADU33HFA1 / FRYER3 / TURBOCHEF6944500.8500.30012739850.5000.333112081153.24.4766711.75.3FANUNITNO.FAN UNIT MODEL NO.SERVES HOOD NO. / TAGCFMESP.RPMH.P.ØVOLTFLAWEIGHT (LBS.)SONES2D76G7DD.66240.4016251.012086.129118.8FANUNITNO.FAN UNIT MODEL NO.BLOWERHOUSINGCFMESP.RPMH.P.ØVOLTFLAWEIGHT (LBS.)SONESEF-4EF-4MEF-4MASSOC.FAN TAGNO.EF-5NO------------2439514043560 deg F7 in. w.c. - 14 in. w.c.NaturalFANUNITNO.INPUT BTUsOUTPUTBTUsTEMP. RISEREQUIRED INPUT GAS PRESSUREGAS TYPEREFER TO DRAWING M-1EF-4EF-5FANTAGNO.FANTAGNO.EF-4M1 / FRYER BACK RETURNSERVES HOOD NO. / TAGREFER TO DRAWING M-1REFER TO DRAWING M-1FANTAGNO.EF-4M1 / FRYER BACK RETURNSERVES HOOD NO. / TAG22 1/2"FLEX CONDUITFOR FIELD WIRING5"9 1/2"5 5/8"DISCHARGE OPENING8 1/2"4 3/16"BLOWER/ MOTORACCESS DOORSERVICE DISCONNECTSWITCHAIR1/2" NPT4"20 5/8"FILTER ACCESSDOORAIRFLOW20 1/8"18 5/8"AIRFLOW22 1/2"24"19 1/2"54 1/4"22 1/8"52"44 3/16"123 7/16"ADJUSTABLELEGFAN NO.2 MODEL D76D - HEATER - EF-4M (FRYER)1. LOW CFM DIRECT FIRED HEATER. DIRECT DRIVE.2. INTAKE HOOD W/EZ FILTERS3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT4. GAS PRESSURE GAUGE, 0-35", 2.5" DIAMETER, 1/4" THREAD SIZE5. GAS PRESSURE GAUGE, -5 TO +15 INCHES WC., 2.5" DIAMETER, 1/4" THREAD SIZE6. CURRENT SENSOR MOUNTED IN FAN FOR USE WITH PRE-WIRE PROVING.7. ECM WIRING PACKAGE AND MANUAL OR 0-10V DC CONTROL FOR SUPPLY ECMOTORS. RTC CONTROLLER.EQUIPMENTCURB ROOFOPENING 2"SMALLERTHEN CURBDIMENSION.SCREENED INTAKE4"Wx4H"x24L" PRESSURE TREATEDWOOD SET ON WALKPAD. ANDSECURE SUPPORT LEG TO WOODROOFGREASE DUCT 8" x 8"DETECTIONTHIS FIRE SUPPRESSION SYSTEM SHALL BE STORED PRESSURE, WET CHEMICALPRE-ENGINEERED FIXED NOZZLE TYPE MANUFACTURED BY PYRO-CHEM OR SIMILAR. SYSTEMSHALL BE LISTED BY UNDERWRITERS LABORATORIES, INC., TESTED TO THE STANDARD U.L. 300AND COMPLIES WITH ALL LOCAL AND/OR STATE CODES OR STANDARDS. THE SYSTEM SHALLPROVIDE AUTOMATIC DETECTION AND ACTUATION. AUTOMATIC ACTUATION IS PROVIDED BY ANAPPROPRIATE NUMBER OF FUSIBLE LINK DETECTORS THAT IS DETERMINED BY THE INSTALLERACCORDING TO APPLIANCES AND OPERATING TEMPERATURES. MANUAL ACTUATION IS PROVIDEDBY A REMOTE PULL STATION WITH A LOCATION DETERMINED IN THE FIELD BY THE INSTALLER.EXPANDED ACCESSORIES ARE CAPABLE OF PROVIDING ELECTRICAL SYSTEM SHUTDOWN. THEEXTINGUISHING AGENT IS POTASSIUM CARBONATE AND IS DESIGNED TO SUPPRESS GREASERELATED FIRES AND TO HELP PREVENT RE-IGNITION AFTER THE DISCHARGE OF THE SYSTEM ISCOMPLETE.SYSTEM SPECIFICATIONS1.INSTALL PER MANUFACTURER'SMANUAL FOR DETAILS ON LIMITATIONSAND/OR RESTRICLIONS.2.SYSTEM CONTROL HEAD, CYLINDER,MANUAL PULL STATION AND FUSIBLELINKS SHALL BE FIELD LOCATED ANDTO BE DETERMINED BY THECONTRACTOR. COORDINATEELECTRICAL CONNECTIONS.SYSTEM INFO:1. PYRO CHEM SYSTEM MODELPCL-3002.PIPING SHALL BE3L8"SCHEDULE 40 BLACK IRON3.NOZZLES SHALL BE LOCATEDABOVE THE SURFACE OF THEFRYERS AND DIRECTED ATTHE CENTER4.ELECTRICAL SHUTDOWNSHALL BE A SHUNT TRIPBREAKERFRY POT14" X 15.5"DRIPBOARD14" X 6"FRYER2D1HDISCHARGECLASS"K"FIREEXTG.2H2HPLENUM37" WIDEMANUAL PULLSTATIONLOCATED 10' AWAY FROMHAZARD INTHE PATH OF EGRESSPCL3003 GALLON10 FLOWS7 USEDMRM&AGENTCYLINDERNOTESFRY POT14" X 15.5"DRIP BOARD14" X 6"FRYER360DETECTOR360DETECTOR4"12"12"1 1/2"3"18"42"17 1/2"TEMP SENSOR (TO BEFIELD WIRED TO THEELECTRICALCONTROL PANEL)NOTES:HANG HOOD AT 78" ABOVE FINISHED FLOOR.THE HOOD IS NSF APPROVED.THE HOOD IS NOT ETL LISTED.FRONT OVERHANG OF TURBOCHEF OVEN= 6"BACK OVERHANG OF TURBOCHEF OVEN = 10"SIDE OVERHANG OF TURBOCHEF OVEN = 8"10"18"18"25 1/2218 1/225 1/4FAN NO. 3 MODEL DU33HFA - EF-5 (TURBOCHEF)TURBOCHEF EXHAUST HOOD AND FAN DETAILS3" FLANGE17.517.5ROOF OPENINGDIMENSIONS20 GAUGESTEEL CONSTRUCTION30"19 1/2"19 1/2"VENTED CURBFAN NO. 1 MODEL DU50HFA - EF-4 (FRYER)MIN 40"TOP OFFINISHED ROOFTEMP SENSOR(TO BE FIELD WIRED TO THEELECTRICAL CONTROL PANEL)3' 1.00"Nom./3' 1.00"OD30"3"FIELD CUT THE 8" X 8" EXHAUSTRISER WITHIN THE 30"X12" DASHEDOUTLINE TO PROVIDE DUCTWORKROUTING TO EF-4 WITH NO OFFSETS4"18"19"2"3"24"U.L. LISTED SCREW12W LED BULBSUPPLY COLLARCONNECTIONFAN AND LIGHTSWITCHESLOCATED HERE2" HIGH SUPPLY COLLAR CONNECTION4.00" X 59.00" BACK RETURN3" INTERNAL STANDOFFGREASE DRAIN WITH REMOVABLE CUP4"FIELD CUT EXHAUST RISERHANGING ANGLESCREW IN 12W LED BULB, L55 SERIES E26CANOPY LIGHT FIXTURE - HIGH TEMPASSEMBLY, 2700-3500K, INCLUDES CLEARTHERMAL AND SHOCK RESISTANT GLOBE.BACKSPLASH 96.00" HIGH X 48.00" LONGFIELD WRAPPER 26.00" HIGH(SEE HOOD OPTIONS TABLE)FIELD INSTALLED QUARTER END PANELSEQUIPMENTBY OTHERS47.0" MAX44"71" AFF TYP.14" NOM.30"4"34"16" SOLO FILTER WITH HOOKFRYER EXHAUST HOOD AND FAN DETAILSIT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCEFROM LIMITED-COMBUSTIBLE AND COMBUSTIBLEMATERIAL IS IN COMPLIANCE WITH LOCAL CODEREQUIREMENTSUPPLY AIR DISCHARGED BELOW COOKINGSURFACEALL ELECTRICAL AND PLUMBING CONNECTIONSMUST BE LOCATED BELOW THE BACK RETURNAIR PLENUMFRYER HOOD MAKE UP AIR UNIT DETAILSFLOW1500500FLOW RATE (cfm)10000.0000.50PRESSURE DROP (in. H20)PRESSURE DROP VS. FLOW RATESPECIFICATION: CAPTRATE GREASE-STOP SOLO FILTERA UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN,THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER FEATURINGLARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE.FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARDGREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASEPARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE ANDCOMPONENTS WHEN ASSEMBLED.2-INCH DEEP HOOD CHANNEL(S).TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY.UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWOFRACTIONAL EFFICIENCY (%)00.120401.0PARTICLE DIAMETER (um)10.0EFFICIENCY VS. PARTICLE DIAMETER6080100THE CAPTRATE GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05.CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:.NFPA #96NSF STANDARD #2UL STANDARD #1046INT. MECH. CODE (IMC)ULC-S6491.001.502.002.503.003.501231 - Grease Box With Grease Cup1 - Current Sensor Mounted in Exhaust Fan for use with Prewire Proving1 - ECM Wiring Package-Exhaust - Manual or 0-10VDC Reference Speed Control (NIDEC Motor)1 - Inlet Pressure Gauge, 0-35"1 - Manifold Pressure Gauge, -5 to 15" wc1 - Current Sensor Mounted in Supply Fan for use with Prewire Proving1 - ECM Wiring Package-Supply - Manual or 0-10VDC Reference Speed Control (NIDEC Motor)1 - Current Sensor Mounted in Exhaust Fan for use with Prewire Proving1 - ECM Wiring Package-Exhaust - Manual or 0-10VDC Reference Speed Control (NIDEC Motor)FANUNITNO.TAGOPTION (Qty. - Descr.)EF-4EF-4MEF-5 NORMAL TEMPERATURE TEST17 1/22128 7/813 1/4221 1/2FEATURES:27 1/4GREASE DRAIN ABNORMAL FLARE-UP TESTOPTIONS0"0°12"- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS)- ROOF MOUNTED FANS- RESTAURANT MODEL- UL705 AND UL762- VARIABLE SPEED CONTROL- INTERNAL WIRING- WEATHERPROOF DISCONNECT- THERMAL OVERLOAD PROTECTION (SINGLE PHASE)- HIGH HEAT OPERATION 300°F (149°C)- GREASE CLASSIFICATION TESTINGEXHAUST FAN MUST OPERATE CONTINUOUSLY WHILEEXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FANPARTS HAVE REACHED THERMAL EQUILIBRIUM, ANDWITHOUT ANY DETERIORATING EFFECTS TO THE FANWHICH WOULD CAUSE UNSAFE OPERATION.EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILEEXHAUSTING BURNING GREASE VAPORS AT 600°F(316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THEFAN BECOMING DAMAGED TO ANY EXTENT THATCOULD CAUSE AN UNSAFE CONDITION.GREASE BOX CURRENT SENSOR MOUNTED INEXHAUST FAN FOR USE WITH PREWIRE PROVING ECMWIRING PACKAGE-EXHAUST - MANUAL OR 0-10VDCREFERENCE SPEED CONTROL (NIDEC MOTOR)PITCHED CURBS AREAVAILABLE FORPITCHED ROOFS.SPECIFY PITCH:EXAMPLE: 7/12 PITCH =30° SLOPENOTE:FANS SIZED FOR SINGLE STORY, STRAIGHTDUCT RUN TO THE ROOF. PLEASE VERIFY.FAN START-UP AND AIR BALANCE IS BYTHE INSTALLING CONTRACTOR AND REQUIRED FOR PROPER OPERATION OF THE HOOD SYSTEM.AN AIR BALANCE REPORT IS REQUIRED ANDIS TO BE SUBMITTED TO THE OWNER UPONCOMPLETION.CAPTIVE AIRE WARRANTY IS FOR PARTS ONLYFOR ONE YEAR. THE INSTALLING CONTRACTOR ISRESPONSIBLE FOR ALL LABOR WARRANTY FOR ONEYEAR.INSTALL ALL CAPTIVE AIRE EQUIPMENT PER LOCALCODES.FEATURES:OPTIONS3" FLANGE17.517.5ROOF OPENINGDIMENSIONS20 GAUGESTEEL CONSTRUCTION30"19 1/2"19 1/2"VENTED CURB0"0°12"PITCHED CURBS AREAVAILABLE FORPITCHED ROOFS.SPECIFY PITCH:EXAMPLE: 7/12 PITCH =30° SLOPE- DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS)- ROOF MOUNTED FANS- RESTAURANT MODEL- UL705- VARIABLE SPEED CONTROL- INTERNAL WIRING- WEATHERPROOF DISCONNECT- THERMAL OVERLOAD PROTECTION (SINGLE PHASE)- HIGH HEAT OPERATION 300°F (149°C)UNORMALTEMPERATURE TEST EXHAUST FAN MUST OPERATECONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F(149°C) UNTIL ALL FAN PARTS HAVE REACHEDTHERMAL EQUILIBRIUM, AND WITHOUT ANYDETERIORATING EFFECTS TO THE FAN WHICHWOULD CAUSE UNSAFE OPERATION.CURRENT SENSOR MOUNTED IN EXHAUST FAN FORUSE WITH PREWIRE PROVING ECM WIRINGPACKAGE-EXHAUST - MANUAL OR 0-10VDCREFERENCE SPEED CONTROL (NIDEC MOTOR)SUPPLY SIDE HEATER INFORMATION:WINTER TEMPERATURE = 0°F. TEMP. RISE = 70°F.BTUs CALCULATED OFF STANDARD AIR DENSITYOUTPUT BTUs AT ALTITUDE OF 0.0 FT. = 47174INPUT BTUs AT ALTITIUDE OF 0.0 FT. = 51277DIRECT FIRED (DF) PROFILE PLATE ASSEMBLYDIRECT FIRED PROFILE PLATE SPECIFICATIONS:DESCRIPTION:APPLICATION:CERTIFICATIONS:GENERAL CONSTRUCTION:DIRECT FIRED BURNERS SHALL HAVE PATENTED (US PATENT NO.: US6629523B2),SELF-ADJUSTING PROFILE PLATES DESIGNED TO ENSURE PROPER AIR VELOCITY ANDPRESSURE DROP ACROSS THE BURNER. PROFILE PLATES SHALL ALLOW BURNERS TOACHIEVE CLEAN COMBUSTION BY LIMITING BY-PRODUCT LEVELS TO A MAXIMUM OF5PPM OF CARBON MONOXIDE (CO), AND 0.5PPM OF NITROGEN DIOXIDE (NO2).SPRING-LOADED BURNER PROFILE PLATES ARE ENGINEERED TO AUTOMATICALLYREACT TO THE MOMENTUM OF A FRESH AIR STREAM, WITHOUT THE NEED FOR ANYMOTORS OR ACTUATORS TO MECHANICALLY ADJUST THEM. WITH THIS FEATURE, ALLDF UNITS ARE DESIGNED FOR DEMAND CONTROL VENTILATION (DCV)REQUIREMENTS.ALL PROFILE PLATE ASSEMBLIES SHALL BE INCLUDED IN THE DF UNIT'S ETL LISTINGAND COMPLY WITH COMBINED SAFETY STANDARDS ANSI Z83.4 AND CSA 3.7(NON-RECIRCULATING DF HEATERS) AND ANSI Z83.18 (RECIRCULATING DF HEATERS).-PROFILE PLATES SHALL BE FORMED FROM G90 GALVANIZED STEEL.-PROFILE PLATES SHALL VARY IN SIZE PER UNIT.-PROFILE PLATES SHALL BE MOUNTED ALONG THE SAME PLANE AS THE DISCHARGE OF THE BURNER.-DESIGN SHALL INCORPORATE PROPERLY TORQUED, PERMANENTLY MOUNTED SPRING HINGES.-SPRING HINGES SHALL BE MADE FROM PLATED STEEL.4"HEIGHT4"1 - I 15-BDD DAMPERNO SCALEDFB/CLW5248-L-MEP2MEP-2HOOD DETAILS2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 123456789MODELEXHAUST FAN WIRINGFAN NO.1 - EF-4 FRYER HOODComponent Identification12345678MODELLabelDescriptionLocationMT-01Fan Motor[2]TR-0124VAC 20VA Transformer[1]Component IdentificationInstalled OptionsRD - REDBL - BLUEWH - WHITEOR - ORANGEBR - BROWNBK - BLACKPK - PINKPR - PURPLEGY - GRAYGR - GREENYW - YELLOWWIRE COLORMain disconnect switchSW-01[2]RTC-FSC-1SC-01[1]DENOTES FIELD WIRINGDENOTES INTERNAL WIRINGNOTESEXHAUST 0.33HP-115V-1P-4.4FLAMOTOR INFOELECTRICAL INFORMATIONMOTOR/CONTROL MCA: 5.5AMOTOR/CONTROL MOP: 15AEXHAUST FAN WIRINGFAN NO.4 - EF-5 TURBOCHEF HOOD12345678910111213141516MODEL17181920212223AccessoriesFAN NO.2 - EF-4M FRYER HOOD BACK RETURNDIRECT FIRED HEATER WRINGST-01SW-01BKMT-01T1T2L2L1CB-01NOTESDENOTES FIELD WIRINGDENOTES INTERNAL WIRINGRDGRCNCFSC-01MVSENSEPVSPARKMV/PVTS-02MA-012345678SPARKPLUGFR-01ST-011413VA-01BLVA-03VA-02TS-05BKTR-01BKGRLabelDescriptionLocationCB-01Circuit breaker (2amp)[3]FR-01Flame rod[16]FSC-01Flame Safety Control[11-14]MA-01[19]MT-01Supply motor[2]PS-01Low Airflow Switch[9]PS-02High Airflow Switch[9]ST-01Supply motor contactor[2][7][9]SW-01Main disconnect switch[2]TS-03Intake air thermostat[10]TR-01Power transformer(200va)[3]TS-02High temp limit switch[10]TS-05Discharge Air Sensor[21]VA-01Pilot gas valve[13]VA-02Main gas valve[18]Component IdentificationVA-03[20]Modulating gas valveWHWHBKT1T2OL-019596OL-0114717NBKBKBKBKGYBLT3L3T35PS-01CNOCPS-02NCBKORTS-03RBW1015208115RDBKBKORRDBLYWORNCSupply motor overloadOL-01[2][7]BKInstalled OptionsDischarge Temp. Control119Modulating Dial/Amplifier24VBK24VG14BLBKBKGYST-01A2A1*** TERMINAL 11 PROVIDES COOLING CONNECTION***BLORST-01A2115WHA1Supply motor contactorWHST-01[2][7][9]BKGND11524WHTR-02Control transformer(20va)TR-02[10]BLN1213LOW FIRESTARTCONNECT POWER TO THE DROPDROP FOR DISCONNECT CONNECTION!ATTENTION ELECTRICIAN!IS FACTORY SUPPLIED12WIRE COLORYW - YELLOWGY - GRAYPR - PURPLEGR - GREENBL-BLUEBR - BROWNOR - ORANGEBK-BLACKWH - WHITEPK - PINKRD - REDSOCKET STYLE"CLION" RELAYCOMCOIL68NCNO24571334SUPPLY 01.0HP-208V-1P-6.1FLACONTACTOR: 100-K09D10OVERLOAD: 193-KB63MOTOR INFOELECTRICAL INFORMATIONMOTOR/CTRL CIRCUIT MCA: 8.8AMOTOR/CTRL CIRCUIT MOP: 15ASee above details.Power Connection240 V 1 PH.Gal-flexconduit(in unit)BKLocationComponent IdentificationField InstalledwiringRDGRFactorywiringDisconnectSwitchDescriptionLabelInstalled OptionsBK - BLACKGR - GREENWIRE COLORNOTESIn Junction BoxEF-4MRD - REDFAN NO.2 - EF-4M FRYER HOOD BACK RETURNINSTALLATION WRINGTURBOCHEFCONTROL PANELINTERFACECASHMISECURE TO WALLWITH 4 SCREWSTEMPROOMMOUNTS IN STANDARD DOUBLEGANG JUNCTION BOXALARM INDICATING LCD SCREEN.BUTTON FUNCTIONS VARY BYMODEL TYPE.CAT-5 CONNECTION ON REVERSE.CONNECTED TO HOOD CONTROL PANEL.BOX SIZE IS14"Wx18"Hx6"DHood Remote Control Panel Specifications:CONTROL PANELFIELD WIRED CONNECTIONSHOOD LIGHTJUNCTION BOXESCAT 5TEMPERATURE SENSORSENSORTEMPERATURE SENSOR(FIELD INSTALLED)TEMPROOMSENSORBOX SIZE IS14"Wx18"Hx6"DALARM INDICATING LCD SCREEN.BUTTON FUNCTIONS VARY BYMODEL TYPE.MOUNTS IN STANDARD DOUBLEGANG JUNCTION BOXControl panel shall be listed to UL standard UL508A.The control enclosure shall be NEMA 1 rated for remote wall mount. The control enclosureis constructed of stainless steel.Temperature probe(s) located in the exhaust duct riser(s) shall be constructed of stainlesssteel.A digital thermostat controller, listed to UL standard UL61010-1, shall be provided toactivate the hood exhaust fans dynamically based on a +10 degree adjustable offset fromthe room temperature sensor. This function shall meet the requirements of IMC 507.2.1.1A digital thermostat controller shall provide adjustable hysteresis settings to prevent cyclingof the fans after the cooking appliances have been turned off and/or the heat in the exhaustsystem is reduced.A digital thermostat controller shall provide an adjustable minimum fan run-time setting toprevent fan cycling.A digital thermostat controller shall disable the supply fan(s), activate the exhaust fan(s),activate the appliance shunt trip, and disable an electric gas valve automatically under thefollowing conditions (as applicable):a. Fire condition detected on a covered hoodb. Excessive temperature detected on any duct temperature sensor in the system (250 Fadjustable)A digital thermostat controller shall allow for external BMS fan control via dry contact(external control shall not override fan operation logic as required by code).An LCD interface shall be provided with the following features:a. On/Off push button fan & light switch activationb. A single low voltage Cat-5 RJ45 wiring connectionC. Temperature sensor failure/mis-wiring detection with audible & visual alarm notificationd. Integrated gas valve reset for electronic gas valves (no reset relay required)e. Fan starter overload trip detection with audible & visual alarm notification.ROOM TEMPERATURESENSOR FOR WALL MOUNTTO T1A AND T1BIN CONTROL PANELFIELD WIRED2"3.25"TYPICAL HOOD CONTROL WITH REMOTE MOUNTED PANELREMOTE MOUNTEDCONTROL CENTERTYPICAL HOOD CONTROL WITH WALL MOUNTED PANELWALL MOUNTED CONTROL CENTER1EF-4SC-211110FPWall Mount In SS BoxFace Mount Right SideOf Hood No. 11 For Lights1 For FansSmart Controls Termostatic ControlExhaustSupply110.5001.0002082083.26.1NO.FANTAGNO.PACKAGEMODEL NO.LOCATIONSWITCHESLOCATIONQUANTITYOPTIONFANS CONTROLLEDTYPEØH.P.VOLTFLA2EF-5SC-110010FPWall Mount In SS BoxSS Wall Mount Box1 FanSmart Controls Termostatic ControlExhaust10.3331154.4EF-4M1 / FRYER3 / TURBOCHEFSERVES HOOD NO. / TAG------SW-01BKMT-01RDGRGRRDBK3412SC-01TR-0124VBKRDWHBK0-10VGNDCONTROLMOTORFOR 230/240V APPLICATIONS*REMOVE ORANGE JUMPEROR*24 VACRDBKP2OPTIONAL 0-10VDCSPEED REFERENCEINPUT+-FEEDBACKSIGNAL4-20MATOECPDC+CS#CT-01LabelDescriptionLocationMT-01Fan Motor[2]SW-01Main disconnect switch[2]24VAC 20VA TransformerRTC-FSC-1TR-01SC-01[1][1]CT-01Current Transducer[2]RD - REDBL - BLUEWH - WHITEOR - ORANGEBR - BROWNBK - BLACKPK - PINKPR - PURPLEGY - GRAYGR - GREENYW - YELLOWWIRE COLORDENOTES FIELD WIRINGDENOTES INTERNAL WIRINGNOTESEXHAUST 0.5HP-208V-1P-3.2FLAMOTOR INFOELECTRICAL INFORMATIONMOTOR/CTRL MCA: 4.0AMOTOR/CTRL MOP: 15ATR-0524VBKRDWHBKSC-010-10VGNDCONTROLMOTOR24 VACRDBKP2OPTIONAL 0-10VDCSPEED REFERENCEINPUT+-FEEDBACKSIGNAL4-20MATOECPDC+CS#SW-01BKMT-01GRWHGRWHBK3412SC-01TR-0124VBKRDWHBK0-10VGNDCONTROLMOTORFOR 230/240V APPLICATIONS*REMOVE ORANGE JUMPEROR*24 VACRDBKP2OPTIONAL 0-10VDCSPEED REFERENCEINPUT+-FEEDBACKSIGNAL4-20MATOECPDC+CS#CT-01CT-01Current Transducer[2]BREAKER PANEL TO CONTROL PANELResponsibility: ElectricianBREAKER PANELCONTROL PANELBREAKER SIZE SHOWN IS THE MAXIMUM ALLOWEDBREAKER 1PHCONTROL POWER. DO NOT WIRETO SHUNT TRIP BREAKER.HotNeutralH1N1120 V15 AGroundGND1ST HOOD LIGHT BREAKER SHARED W/ CONTROLPOWER. SWITCH #1BREAKER 1PHMCA:MOCP:LEG 1LEG 2L1L2GNDGroundEF-4 FRYE208 V5.0 A15 ABREAKER 1PHMCA:MOCP:LEG 1LEG 2L3L4GNDGroundEF-4M FRY208 V6.2 A15 ACONTROL PANEL TO FANSResponsibility: ElectricianCONTROL PANELFANSLoad WiringWIRE DIRECTTO STARTERWIRE TODISCONNECTFLA:HP:VOLT:T1T2EF-4 FRYELEG 1 / HOTLEG 2 / NEUTRALGNDGROUNDC-101FAN:3.20.500208 VLoad WiringWIRE DIRECTTO STARTERBLACKWHITEGREENWIRE TO FACTORY PROVIDED CONDUIT DROP FLA:HP:VOLT:T1T2LEG 1 / HOTLEG 2 / NEUTRALGNDGROUNDC-2EF-4M FRY02FAN:7.31.00208 VCONTROL PANEL TO ACCESSORY ITEMSResponsibility: ElectricianCONTROL PANELCOMPONENTWIRE C1 TO COMMON (1).C1 TO AR1 SHOULD HAVECONTROL PANELFIRE SYSTEMTOMICROSWITCHCONTINUITY WHEN ARMED.IF MORE THAN ONEWIRE AR1 TO NORMALLY CLOSED (2).CAPOFFCAPOFFCAPOFFFIRE SYSTEM, WIREIN SERIES AS SHOWNC1AR1MICROSWITCH 11:C4:NO2:NCMS-11:C4:NO2:NC1:C4:NO2:NCMS-2WIRE DIRECTLY TO CONTROL BOARDCAT-5 CONNECTIONCONTROL PANELREMOTETOMOUNTEDSWITCHESPLACE END OF LINE PLUGEOL120AIN EMPTY JACK. PN: EOL120AHMIJ412CONTROL PANELHOOD LIGHTSTO1400 W MAXWIRE TO J-BOX ON TOP OF HOODB1W1GNDBLACKWHITEGREENHOOD LIGHTS 1WIRE TO CONTROL BOARD.SENSOR MOUNTED IN ROOM AWAYFROM HEAT SOURCES. SEE MANUALCONTROL PANELKITCHEN TEMPTOSENSORT1AT1BROOM TEMPWIRE TO CONTROL BOARD.SENSOR MOUNTED IN EXHAUST DUCTCONTROL PANELDUCT SENSORTOT2AT2BHOOD 1RISER 1THE FOLLOWING CONNECTIONSMAY OR MAY NOT BEREQUIRED BASED ON JOBSITE SPECIFICATIONSCONTROL PANELEXTERNALSIGNAL FORSHUNT TRIPST TERMINAL IS ENERGIZEDIN FIRE CONDITION.STN1NEUTRAL FROM SHUNT COILHOT TO SHUNT COILSHUNT COILSPARE CONTACTS USED WHEN FIRESYSTEM DRYSPARE FIRECONTACTSYSTEM DISCHARGES TO DISABLEEQUIPMENT OR PROVIDE SIGNALS.(NOT FOR BUILDING FIRE ALARMWHICH MUST BE WIRED DIRECTLYTO THE ANSUL ALARM INITIATINGSWITCH LOCATED IN ANSUL AUTOMAN)CONTROL PANELC2AR2COMMONNORMALLY OPENTHIS CONTROL PANEL HAS FANPROVING SHUTDOWN ENABLED.SEE MANUAL FOR REQUIREMENTS.CALIBRATON REQUIRED!!NOTE TO INSTALLER:THIS PANEL HAS CURRENT SENSORSINSTALLED. SEE OPERATIONS MANUALFOR INSTRUCTIONS TO CALIBRATE.CONTROL PANEL INSTALLATIONFRYER HOOD SYSTEM SCHEMATICSC-211110FPMODEL:DESCRIPTION OF OPERATION:220V 1 Phase w/ 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation.H1IO1CONTROL PANELEXTERNALTOBMS_SWITCHSWITCHCNOSIGNAL SWITCH THROUGH BMSWILL ACTIVATE ZONE1 FANS ANDLIGHTSshipped loose for field installation.BREAKER PANEL TO CONTROL PANELResponsibility: ElectricianBREAKER PANELCONTROL PANELBREAKER SIZE SHOWN IS THE MAXIMUM ALLOWEDBREAKER 1PHCONTROL POWER. DO NOT WIRETO SHUNT TRIP BREAKER.HotNeutral H1N1120 V15 AGroundGNDBREAKER 1PHMCA:MOCP:HotNeutral L1FN1GNDGroundEF-5 TURB115 V5.5 A15 ACONTROL PANEL TO FANSResponsibility: ElectricianPRIMARY PANELFANSLoad WiringWIRE DIRECTTO STARTERWIRE TODISCONNECTFLA:HP:VOLT:T1T2EF-5 TURBLEG 1 / HOTLEG 2 / NEUTRALGNDGROUNDC-104FAN:4.40.333115 VCONTROL PANEL INSTALLATIONTURBO CHEF HOOD SYSTEM SCHEMATICSC-110010FPMODEL:DESCRIPTION OF OPERATION:120V 1 Phase w/ 1 Exhaust Fan, Exhaust on in Fire, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor shipped loose for field installation.CONTROL PANEL TO ACCESSORY ITEMSResponsibility: ElectricianCONTROL PANELCOMPONENTWIRE C1 TO COMMON (1).C1 TO AR1 SHOULD HAVECONTROL PANELFIRE SYSTEMTOMICROSWITCHCONTINUITY WHEN ARMED.IF MORE THAN ONEWIRE AR1 TO NORMALLY CLOSED (2).CAPOFFCAPOFFCAPOFFFIRE SYSTEM, WIREIN SERIES AS SHOWNC1AR1MICROSWITCH 11:C4:NO2:NCMS-11:C4:NO2:NC1:C4:NO2:NCMS-2C1AR1ALL SWITCHES FACTORY WIREDCAT-5 CONNECTIONCONTROL PANELSWITCHESTOJ4CONTROL PANELHOOD LIGHTSTO1400 W MAXWIRE TO J-BOX ON TOP OF HOODB1W1GNDBLACKWHITEGREENHOOD LIGHTS 1WIRE TO CONTROL BOARD.SENSOR MOUNTED IN ROOM AWAYFROM HEAT SOURCES. SEE MANUALCONTROL PANELKITCHEN TEMPTOSENSORT1AT1BROOM TEMPWIRE TO CONTROL BOARD.SENSOR MOUNTED IN EXHAUST DUCTCONTROL PANELDUCT SENSORTOT2AT2BHOOD 2RISER 1THE FOLLOWING CONNECTIONSMAY OR MAY NOT BEREQUIRED BASED ON JOBSITE SPECIFICATIONSCONTROL PANELEXTERNALSIGNAL FORSHUNT TRIPST TERMINAL IS ENERGIZEDIN FIRE CONDITION.STN1NEUTRAL FROM SHUNT COILHOT TO SHUNT COILSHUNT COILSPARE CONTACTS USED WHEN FIRESYSTEM DRYSPARE FIRECONTACTSYSTEM DISCHARGES TO DISABLEEQUIPMENT OR PROVIDE SIGNALS.(NOT FOR BUILDING FIRE ALARMWHICH MUST BE WIRED DIRECTLYTO THE ANSUL ALARM INITIATINGSWITCH LOCATED IN ANSUL AUTOMAN)CONTROL PANELC2AR2COMMONNORMALLY OPENTHIS CONTROL PANEL HAS FANPROVING SHUTDOWN ENABLED.SEE MANUAL FOR REQUIREMENTS.CALIBRATON REQUIRED!!NOTE TO INSTALLER:CONTROL PANELEXTERNALTOSWITCHSIGNAL SWITCH THROUGH BMSWILL ACTIVATE ZONE1 FANS ANDLIGHTSH1IO1BMS SWITCHCNOTHIS PANEL HAS CURRENT SENSORSINSTALLED. SEE OPERATIONS MANUALFOR INSTRUCTIONS TO CALIBRATE.WHBKBKBKBKABCDEFGHI12345678910FACTORY WIRINGSCHEMATICCIRCUIT BOARDSDCV Rev. 2.06.00HMI Rev. 2.06.00MOTOR POWER CIRCUITPANEL LIDCOMPONENT LISTLABEL DESCRIPTIONPN:RA-x34.110.0184.0120V Relay DPDTPN:ST-XvariesStarterPN:OL-XvariesOverloadPN:C-XvariesContactor120 VACRELAYRA-x24 VDCRELAYRD-xPN:PS-1MDP18-24A-1CPower Sup. 24VDCPN:CS-xA/CTA-50Current SensorGRUNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG.N1H1DC-GND8H17PCU6ST5KS4KTS3GAS2AR11N1120VJ95OV14SF13EF12B11IO1120VJ7H12xN12xAR1GASSTC1B1EF1SF1BKIO1N1BKBKBKJUMPERW1BK 14AWGBK64RD-1BLPRPN:RD-x34.110.0188.0 24VDC Light RelayBLPRCS-1BKWHAR1N1RA-1C-1RD-1DRY CONTACTS (SHOWN DE-ENERGIZED)24V1234567891011121314J6HOOD LIGHTSECPM03J10IL1A IL1B JUMPERMAKE UP AIR INTERLOCK.RA-1-1C2AR214 AWGYW14 x 18 x 6 BoxCONTROL INPUT120V H1=LINE,N1=NEUTRAL, 15ABREAKER. DO NOTCONNECT TOSHUNT TRIPBREAKER. SEEINSTALLATIONSCHEMATIC FORADDITIONAL REQ.LEGENDFIELD WIRINGFACTORY WIRINGBK- BLACK YW- YELLOWBL- B LUE G Y- GRE Y BR- BROWN PR- PUR P LEOR- ORANGE RD- REDWH- WHITEOR/BL- OR/BL STRIP EBL/RD- BL/ RD S TRI PERD/GN- RD/GN STRIPEWH/BL- WH/BL STRIPE WH/BL BLH1 N1 DC- DC+LN-+PS-01AC24VDCWHGR/YW WH/BL PR BL PR DC+ GND CS1DC+CS1 RO1RO1DC+DWG NOJOB NODATEDRAWN BYJOB NAMEDESCRIPTION OF OPERATIONTYPEDRAWING TITLE3085088SHEETZ_Westminst...FACTORYSC-110010FP7/18/2017ECP #2-2120V 1 Phase w/ control for 1Exhaust Fan, Exhaust on in Fire,Fan(s) On/Off ThermostaticallyControlled. Room temperaturesensor shipped loose for fieldinstallation.BKWHT1T2T3L1L2L31413CONT:FLA:MTR:HP:L1FN1C-114 AWG1 PH15 A115 VCS1EXH-3100-K05D104.40.333120 VACRELAYRA-x24 VDCRELAYRD-xLEGENDFIELD WIRINGFACTORY WIRINGBK- BLACK YW- YELLOWBL- B LUE G Y- GRE Y BR- BROWN PR- PUR P LEOR- ORANGE RD- REDWH- WHITEOR/BL- OR/BL STRIP EBL/RD- BL/ RD S TRI PERD/GN- RD/GN STRIPEWH/BL- WH/BL STRIPE WHBKBKBKBKABCDEFGHI12345678910FACTORY WIRINGSCHEMATICCIRCUIT BOARDSDCV Rev. 2.06.00HMI Rev. 2.06.00MOTOR POWER CIRCUITPANEL LIDCOMPONENT LISTLABELDESCRIPTIONPN:RA-x34.110.0184.0120V Relay DPDTPN:ST-XvariesStarterPN:OL-XvariesOverloadPN:C-XvariesContactorPN:PS-1MDP18-24A-1CPower Sup. 24VDCPN:CS-xA/CTA-50Current SensorGRUNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG.N1H1DC-GND8H17PCU6ST5KS4KTS3GAS2AR11N1120VJ95OV14SF13EF12B11IO1120VJ7H12xN12xAR1GASSTC1B1EF1SF1BKIO1N1N1BKBKBKJUMPERW1BK 14AWGBK64RD-1BLPRPN:RD-x34.110.0188.0 24VDC Light RelayBLPRCS-2CS-1BLPRBKWHAR1N1RA-1C-2C-1RD-1DRY CONTACTS (SHOWN DE-ENERGIZED)24V1234567891011121314J6HOOD LIGHTSECPM03J10IL1A IL1B JUMPERMAKE UP AIR INTERLOCK.RA-1-1C2AR214 AWGYW14 x 18 x 6 BoxCONTROL INPUT120V H1=LINE,N1=NEUTRAL, 15ABREAKER. DO NOTCONNECT TOSHUNT TRIPBREAKER. SEEINSTALLATIONSCHEMATIC FORADDITIONAL REQ.WH/BL BLH1 N1 DC- DC+LN-+PS-01AC24VDCWHGR/YW WH/BL PR PR BL PR DC+ GND CS1DC+CS1CS2CS2 RO1RO1DC+DWG NOJOB NODATEDRAWN BYJOB NAMEDESCRIPTION OF OPERATIONTYPEDRAWING TITLE3085088SHEETZ_Westminst...FACTORYSC-211110FP7/18/2017ECP #1-2220V 1 Phase w/ control for 1Exhaust Fan, 1 Supply Fan,Exhaust on in Fire, Lights out inFire, Fan(s) On/Off Thermostatical lyControlled. Room temperaturesensor shipped loose for fieldinstallation.BKBKT1T2T3L1L2L31413CONT:FLA:MTR:HP:L1L2C-114 AWG1 PH15 A208 VCS1EXH-1100-K05D103.20.500BKBKT1T2T3L1L2L31413CONT:FLA:MTR:HP:L3L4C-214 AWG1 PH15 A208 VCS2SUP-2100-K09D107.31.000NO SCALEDFB/CLW5248-L-MEP3MEP-3HOOD WIRING DIAGRAMS2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 PIPING NOTES: GENERAL NOTES: TO PULL STATION(MOUNT TO CODE)3/8" AGENTDISTRIBUTIONLINEFIRE SUPPRESSION TANK.TO DETECTORSSCISSOR STYLE SERIES DETECTOR DETAILN.T.S.ELECTRICAL NOTES:PULLMANUAL PULL STATION TO BE LOCATED 10' TO 20'NEAR OR AT THE MEANS OF EGRESSFIRESUPPRESSIONTANK1WASTM A 733/A53 ERUSTANDARD BLACK 3/8PIPEPIPING LENGTHSHOOD DIMENSIONSFUSIBLE LINK DETECTORS(SEE GENERAL NOTE 9)ELECTRIC FRYERS K CLASS FIRE EXTINGUISHER TOBE MOUNTED WITHIN 30' OF THE HOOD37"30"85"36"1N23023023023012"6'42"15.5"12"11"FRONT VIEWTOP VIEW9"9"9"9"4"11"NOTE: THE FIRST NUMBER IN ANY NOZZLE DESIGNATIONINDICATES THE FLOW NUMBER OF THE NOZZLE.3 GALLON SYSTEM11 FLOW POINTS10 USEDTOTAL 10DUCT 8" X 8" 1 1WPLENUM 37" 1 1NFRYER SPLIT VAT 15" X 16.5" 21" OVERALL 4 230 X 2FRYER SPLIT VAT 15" X 16.5" 21" OVERALL 4 230 X 21.THIS INSTALLATION IS TO BE MADE IN ACCORDANCE WITH THE R-102, UL300INSTALLATION MANUAL AND IN ACCORDANCE WITH ALL STATE AND LOCALCODES.2.provide audible / visual alarm accessory.3.ALL PIPE LENGTHS TO BE FIELD VERIFIED.4.THESE DRAWINGS MAY BE USED TO SECURE APPROVAL FROM THEAUTHORITY HAVING JURISDICTION.5.IT IS NECESSARY THAT ALL PIPE FITTINGS AND NOZZLES BE WRENCHTIGHTENED AND SECURELY SUPPORTED AND THAT ALL NOZZLES AREPROPERLY AIMED AS INDICATED IN THE R-102 INSTALLATION MANUAL.6.THE WIRE ROPE FOR THE DETECTOR, REMOTE PULL STATION, AND THEMECHANICAL GAS VALVE IS TO INSTALLED BY AN AUTHORIZED ANDFACTORY TRAINED DISTRIBUTOR OR SERVICE REPRESENTATIVE.7.THIS INSTALLATION IS TO BE INSPECTED, PUT INTO OPERATION, ANDCERTIFIED BY AN AUTHORIZED AND FACTORY TRAINED DISTRIBUTOR ORSERVICE REPRESENTATIVE.8.Electrical contacts, audible / visual alarm wiring, and wiring forappliance shut off shall be provided by the electricalcontractor.9.PIPING AND CONDUIT HOOD PENETRATIONS TO USE SEAL FAST HOODADAPTERS.10.360 DEG. F. FUSIBLE LINK TO BE USED WITH ELECTRIC FRYERS ONLY.11.500 DEG. F. FUSIBLE LINKS TO BE USED ON ALL HIGH EFFICIENCY GASFRYERS.1.PIPE SHALL BE 3/8" SCHEDULE 40 BLACK IRON, CHROME PLATED, ORSTAINLESS STEEL.2.PIPE ENDS SHALL BE REAMED AND BLOWN CLEAR OF CHIPS AND SCALEBEFORE ASSEMBLY. INSIDE OF PIPE AND FITTINGS MUST BE FREE OF OILAND DIRT.3.PIPING DIMENSIONS GIVEN ARE FROM CENTER TO CENTER OF FITTINGS.4.FINAL NOZZLE LOCATION MAY VARY FROM LOCATION SHOWN.5.ADD UNIONS AS NEEDED.6.FIRE SUPPRESSION TANK LOCATED ON WALL.7.ALL PIPE CONNECTIONS MUST USE TEFLON TAPE ON THE MALE THREADSONLY. MAKE CERTAIN TAPE DOES NOT COVER LAST THREAD ON PIPE END.8.MAKE CERTAIN THAT THERE IS A MINIMUM OF 6' (SIX FEET) OF PIPE BETWEENTHE AGENT TANK AND ANY NOZZLE PROTECTING A FRYER.1.NO ELECTRICAL CONNECTIONS SHALL BE MADE INSIDE OF FIRE SUPPRESSIONTANK.2.electrical devices under and associated with the hood are tode-engerize entirely, audible / visual alarm shall sound, andelectrical devices are not to re-engergize until fire system isrecharged and reset.THIS DESIGN IS IN COMPLIANCE WITH UL 300, NFPA 96, & NFPA 17A.TO audible / visualAS NOTEDDJA4772-R-FP1FP-1FIRE PROTECTION DETAILS 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 VSHUT OFF VALVE/BALL VALVECHECK VALVEVENT PIPINGHWHOT WATER PIPINGCOLD WATER PIPINGSANSANITARY WASTE PIPINGDROP IN PIPINGCO.RISE IN PIPINGFLOOR CLEANOUTFD.FLOOR DRAINWATER HAMMER ARRESTORWHA.HB.HOSE BIBBBACKFLOW PREVENTERBFP.PLUMBING LEGENDDETAILDESCRIPTIONCWSHEAR-GATE AND SWING-CHECKCOMBINATION VALVEUNIONFFILTERED WATERIMFICE MAKER FEEDER WATERFSFLOOR SINKBALANCING VALVESTRAINERRELIEF VALVEPRESSURE REDUCING VALVEPRV.INDIRECT WASTE LINE TOFLOOR SINK/FLOOR DRAINGGAS PIPINGGGAS VENT PIPINGHOT WATER RETURN PIPINGWRWASTE RECEPTORCDLCONDENSATE PIPINGSANITARY STORM PIPINGTRAP PRIMER PIPINGTPGREASE SANGREASE SANITARY WASTE PIPINGTPTRAP PRIMER VALVEPRESSURE GAUGEGAS SHUT-OFF VALVEUNTREATED WATER PIPINGUTWABVAFFARCH@BFFBFPBLDGBLWBTCCCSCDLCICLGCOCONDCONNCONTCONTRcpCWWDETDIADNDWGDFDMDSDSPEAECELECELEVESESHEXEXTetFDFINFLFRSFSFTGCABOVEABOVE FINISHED FLOORARCHITECTATBELOW FINISHED FLOORBACKFLOW PREVENTERBUILDINGBELOWBELOW THE COUNTERCOFFEE COUNTER SINKCONDENSATE DRAIN LINECAST IRONCEILINGCLEANOUTCONDENSATECONNECTIONCONTINUATIONCONTRACTORcirculation pumpCLEAR WATER WASTEDETAILDIAMETERDOWNDRAWINGDRINKING FOUNTAINDISH MACHINEDROP SINKDOWN SPOUTEACHELECTRICAL CONTRACTORELECTRICALELEVATIONEQUIPMENT SUPPLIEREMERGENCY SHOWEREXISTINGEXTERIORexpansion tankFLOOR DRAINFINISHEDFLOORFLAT RIM SINKFLOOR SINKFEETGENERAL CONTRACTORGiGPFGPHHBHGTHSININVIWLAVMCMECHMHMSNICNOPBLGPCPOCPRVRDREQDRWCSANSHTSOVSPECSSTPTYPURutwVVTRWW/WFW/OWCWCOWHWHAWPWRwtGREASE INTERCEPTORGALLONS PER FLUSHGALLONS PER HOURHOSE BIBBHEIGHTHAND SINKINCHINVERTINDiRECT WASTELAVATORYMECHANICAL CONTRACTORMECHANICALMANHOLEMOP SINKNOT IN CONTRACTNUMBERPLUMBINGPLUMBING CONTRACTORPOINT OF CONNECTIONPRESSURE READING VALVEROOF DRAINREQUIREDRAIN WATER CONDUCTORSANITARYSHEETSHUT OFF VALVESPECIFICATIONSERVICE SINKTRAP PRIMERTYPICALURINALuntreated waterVENTVENT THROUGH ROOFWASTEWITHWATER FILTERWITHOUTWATER CLOSETWALL CLEANOUTWATER HEATERWATER HAMMER ARRESTORWEATHERPROOFWASTE RECEPTORwater softenerPLUMBING ABBREVIATIONSPLUMBING FIXTURE PROCUREMENT AND INSTALLATION SCHEDULEPLUMBING EQUIPMENTFURNISHED BYINSTALLED BYLAV - LAVATORY, BOWL, FAUCET, SOAP DISP. & CABINETOWNERPLUMBING CONTRACTORWC-1 - WATER CLOSETPLUMBING CONTRACTORPLUMBING CONTRACTORPLUMBING CONTRACTORUR - URINALMS-1 - MOP SINKDF - WATER DRINKING FOUNTAINWH-1 - gas WATER HEATER, drain pan & etWF - WATER FILTERGi - GREASE INTERCEPTORHS - HAND SINKDS - DROP IN SINKCCS - COFFEE COUNTER SINKHB - HOSE BIBSITE CONTRACTOROWNERPLUMBING CONTRACTORPLUMBING CONTRACTORPLUMBING CONTRACTORPLUMBING CONTRACTORPLUMBING CONTRACTORSITE CONTRACTORPLUMBING CONTRACTORPLUMBING CONTRACTORPLUMBING CONTRACTORPLUMBING CONTRACTORownerPLUMBING CONTRACTORPLUMBING CONTRACTORPLUMBING CONTRACTOROWNEROWNEROWNERWC-2 - WATER CLOSETPLUMBING CONTRACTORPLUMBING CONTRACTORsupplierwt - water softenersupplierPLUMBING CONTRACTORwf - water filterownerownerdm - dishmachineownercp - circulation pump, balancing valves & tri-ometerOWNERPLUMBING CONTRACTOR WH-1 GAS WATER HEATER BRADFORD WHITE MODEL EF-100T-150E-3NA (WITH HIGH TEMPERATURE CUT-OFF SWITCH). GlAsS LINED TANK,1" RELIEF VALVE TAPPING, ANODE ROD, FOAM INSULATED OUTER JACKET W/ BAKED ENAMEL FINISH. ASMECONSTRUCTION. DRAIN PAN UNDER WATER HEATER WITH 3/4" MINIMUM DRAIN LINE TO FLOOR DRAIN. ASMERATED EXPANSION TANK, BELL & GOSSETT PL-30B 1/12 HP BUILDING CIRCULATOR PUMP 120V-IPH-60 HZ.PROVIDE WEISS TRI-O-METER SERIES "H" MODEL HTP40RSX, W/2 1/2" DIAL W/1/2" NPT REAR CONNECTION."PROVIDE WITH ACID NEUTRALIZATION KIT." SET TANK OUTLET TEMPERATURE AT 125 DEGREES.PLUMBING FIXTURE SCHEDULEWC-2 WATER CLOSET SAME AS WC-1 BUT MOUNTED WITH SEAT AT 18" AFF FOR DISABLED ADULT USE AND CARRIER SUPPORT. FD FLOOR DRAIN ZURN ZB-415, DURA-COATED CAST IRON BODY WITH BOTTOM OUTLET, COMBINATION INVERTIBLEMEMBRANE CLAMP AND ADJUSTABLE COLLAR WITH TYPE B POLISHED BRONZE STRAINER,6" STRAINER, 1/2" TRAP PRIMER CONNECTION WHERE NOTED. HB HOSE BIBB ZURN Z-1321XL, EXPOSED ANTI-SIPHON AUTOMATIC DRAINING WALL HYDRANT, LEAD FREE, NON-FREEZE INTEGRAL BACKFLOW PREVENTER, COPPER CASING, ALL BRONZE INTERIOR PARTS, NON-TURNING OPERATING ROD, 3/4" SOLDER INLET POLISHED BRONZE FACE, OPERATING KEY.LAV LAVATORY WILSONART INTERNATIONAL VANITY BOWL, BV123, TECHNICAL CONCEPTS MODEL 500484, BATTERY POWERED, 0.50 GPM AUTOMATIC SYSTEM SENSOR OPERATED WITH WATTS LFUSG-B-M2 THERMOSTATICMIXING VALVE WITH DUAL CHECK VALVES, GRID DRAIN, OFFSET DRAIN PIPING WITH P-TRAP ANGLE VALVE INSULATION, SET FAUCET TO A MINIMUM RUN TIME OF 15 SECONDS. COUNTER TOP AS FURNISHED BY CABINET MANUFACTURER. FURNISHED BY OWNER.WC-1 WATER CLOSET AMERICAN STANDARD 2257.101, WALL HUNG, VITREOUS CHINA, 1.6 GPF, ELONGATED BOWL, SIPHON JET ACTION, 1-1/2" TOP SPUD. PROVIDE CHURCH 245C WHITE OPEN FRONT SEAT. PROVIDE ZURN AQUASENSE AV, ZER 6000AV-CPM, BATTERY POWERED AUTOMATIC SYSTEMS SENSOR-OPERATEDAQUAVANTAGE FLUSHOMETER. CARRIER SUPPORT SYSTEM SHALL BE ONE OF THE FOLLOWING:JOSAM 16123 (typ), josam 14484 (back-to-back), OR APPROVED EQUAL.UR URINAL ZURN Z5755-U VITREOUS CHINA, .125 GPF, FLUSHING RIM, ELONGATED RIM, EXTENDED SIDES, 3/4" INLET TOP SPUD, WALL HANGERS. PROVIDE ZURN ECOVANTAGE, ZTR6203-ULF, BATTERY POWEREDAUTOMATIC SYSTEMS SENSOR-OPERATED FLUSHOMETER, JOSAM 17800/17550 TYPE CARRIER ORAPPROVED EQUAL. MS-1 MOP SINK ZURN , 36"X24"X10", MODEL NO. Z1996-36-BS-WG. WITH 3" STAINLESS STEEL STRAINER, 3" GASKETED OUTLET CONNECTION, STAINLESS STEEL PROTECTIVE CAP CAST INTEGRALLY ON EXPOSED SIDES. PROVIDE MOP HANGER, HOSE AND HOSE BRACKET. PROVIDE T & S BRASS B-0665-BSTP FAUCETWITH INLET STOPS, ETERNA SPRING CHECK CARTRIDGES, LEVER HANDLES W/COLOR CODED INDEXES, AND POLISHED CHROME FINISH. SUPPLY FITTINGS SHALL BE MOUNTED WITH CENTERLINE 36" ABOVE FINISHED FLOOR. DF WATER DRINKING FOUNTAIN ELKAY, MODEL NO. EDFPBM117C TWO-LEVEL, WALL MOUNT, BARRIER-FREE DRINKING FOUNTAIN. LEAD FREE. WR-1 WASTE RECEPTOR TYPE "WR" WASTE RECEPTOR DRAINS SHALL BE 3" DIAMETER PVC SCHEDULE 40 PIPE WITH HUB PORTION OF PIPE EXTENED APPROXIMATELY 4-5" ABOVE THE FINISHED FLOOR TO SERVE INDIRECTWASTE PIPING. ALL WASTE RECEPTORS SHALL BE PROVIDED WITH A P-TRAP INSTALLED BELOW THEFINISHED FLOOR.PORTION OF PIPE EXTENED 1" ABOVE THE FINISHED FLOOR TO SERVE INDIRECT WASTE PIPING. ALLWASTE RECEPTORS SHALL BE PROVIDED WITH A P-TRAP INSTALLED BELOW THE FINISHED FLOOR. DS DROP IN SINK sterling top mount stainless steel sink, model b 155-2, one-piece seamless bowl construction, PROVIDE T&S BRASS MODEL B-1141-5-3/4" SPREAD SWIVEL, GOOSENECK FAUCET WITH B-PT STREAM REGULATOR OUTLET AND LEVER HANDLES. SUPPLY FITTINGS SHALL BE MOUNTED WITH CENTERLINEBTC @ 30". FURNISHED BY OWNER. PROVIDE IN-LINE THERMOSTATIC MIXING VALVE TO TEMPER HOT WATER. HS-1 HAND SINK EAGLE FOOD SERVICE EQUIPMENT MODEL HSA-10-FW, 20 GAUGE 304 STAINLESS STEEL ONE-PIECE SEAMLESS BOWL CONSTRUCTION, 9 3/4" x 13 1/2" x 6 3/4" DEEP, PROVIDE GOOSENECK FAUCET WITH LEVER HANDLES. SUPPLY FITTINGS SHALL BE MOUNTED WITH CENTERLINE BTC @ 30". FURNISHED BY OWNER. WR-2 WASTE RECEPTOR TYPE "WR" WASTE RECEPTOR DRAINS SHALL BE 3" DIAMETER PVC SCHEDULE 40 PIPE WITH HUB tp trap primer trap primers shall be mifab no. mr-500, precision plumbing products, or approved equal. primersshall be machined of corrosion resistant brass, without springs or diaphragms; with "o" ring seals.units shall be of type capable of operation when installed at 12" minimum above traps. units shall betype capable of automatically maintaining a constant waterseal in several floor drain traps at onetime. valve all inlet piping to each trap primer. FS FLOOR SINK zurn fd-2370, 12" x 12" x 8" deep pvc body, with 1/2 grate and dome strainer. MV MIXING VALVE WATTS LFUSG-B-M2 THERMOSTATIC MIXING VALVE WITH DUAL CHECK VALVES MEETING ASSE 1070. SET AT 105DEGREES OR AS DIRECTED BY OWNER. CCS COFFEE COUNTER SINK 17"X19" CUSTOM STAINLESS SINK. FURNISHED BY MILLWORK VENDOR/OWNER. PROVIDE IN-LINE THERMOSTATICMIXING VALVE, TO TEMPER HOT WATER. Gi GREASE INTERCEPTOR PRECAST CONCRETE, 2000 GALLON TANK VAULT REINFORCED FOR H20 LOAD RATING, 4" INLET AND OUTLET, INTERIOR BAFFLES, 22"ACCESS AND TWO 4" INSPECTION PORTS. PROVIDE RISER RINGS TO GRADE, AS REQUIRED. MANUFACTURED BY A.C. MILLER MODEL 2000 GALLONS, OR EQUAL. APPROVED BY OWNER.SHALL BE ONE OF THE FOLLOWING: JOSAM 16123 (typ), josam 14484 (back-to-back), OR APPROVED EQUAL. rh roof hydrant non-freeze, woodford manufacturing co. model rhy2-ms, complete with mounting system, 3/4" hoseconnection backflow preventer, asse 1052 listed. extend 1/2" copper drain from hydrant drainport and terminate over mop basin. installation shall be in accordance with manufacturerswritten instructions. DM DISHMACHINE DISHMACHINE SCULLERY LOWTEMP ventless model est - BY CMA. CUSTOM 102" DISHTABLE SINK (16 GAUGE STAINLESS steel CONSTRUCTION. (3) 21"X18"X14" DEEP SINK BOWLS, SCRAP BASKET/RACK SLIDE COMBO, 1-5/8" GALVANIZED LEGS,ADJUSTABLE PLASTIC BULLET FEET with temp sure hot water assurance system.) WT WATER softener WHEN SHOWN ON THE DRAWINGS TO BE INSTALLED, WATER SOFTENER SYSTEM SHALL BE CULLIGAN, PROVIDED BYSTONER WATER INC. 501 MARYLAND AVENUE, HAGERSTOWN, MD. 21740. PH: 301-797-0311.PLUMBING CONNECTIONSFIXTURECW1/2"LAVLAVATORYWCWATER CLOSETURURINALMSMOP SINKDFWATER DRINKING FOUNTAINFDFLOOR DRAINFSFLOOR SINKHBHOSE BIBBGiGREASE INTERCEPTOR1"3/4"3/4"1/2"----3/4"--HW1/2"----3/4"----------SAN2"4"2"3"2"3"3"--4"VENT2"2"2"2"2"2"2"--3"NOTE: SEE FOOD SERVICE EQUIPMENT CONNECTION SCHEDULE, SHEET P-6,FOR INFORMATION ON FOOD SERVICE EQUIPMENT.WRWASTE RECEPTOR----3"2"1/2"HSHAND SINK1/2"2"2"1/2"DSDROP SINK1/2"2"2"1/2"CCSCOFFEE COUNTER SINK1/2"2"2"rhroof hydrant3/4"--1/2"--PLUMBING NOTES1.THE DRAWINGS ARE INTENDED TO COVER SYSTEMS WHICH WILL FIT THE AVAILABLE SPACE, WHICH WILL NOT INTERFERE WITH THE GENERALSTRUCTURAL DESIGN. CAREFULLY EXAMINE THE DRAWINGS FOR ALL BRANCHES OF WORK AND BE RESPONSIBLE FOR THE PROPER FITTING OFMATERIAL AND APPARATUS INTO THE BUILDING. COORDINATE THE EXACT LOCATION OF EQUIPMENT AND EQUIPMENT CONNECTIONS WITH THEARCHITECT AND EQUIPMENT SUPPLIER.2.ALL COMPONENTS USED IN THE DOMESTIC WATER SYSTEM SHALL BE LEAD FREE AND SHALL CONFORM TO THE SAFE DRINKING WATER ACT, ASAMENDED ON 01-04-2011, SECTION 1417.3.INSTALLATION SHALL BE PERFORMED IN ACCORDANCE WITH THE 2012 north carolina PLUMBING CODE AND OTHER APPLICABLE REGULATIONS.4.GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS, AND PAY ALL COSTS IN CONNECTION WITH THE WORK, FILE ALL NECESSARY PLANS, PREPAREALL DOCUMENTS AND OBTAIN ALL NECESSARY APPROVALS OF ALL REGULATING AUTHORITIES HAVING JURISDICTION, OBTAIN ALL REQUIREDCERTIFICATES OF INSPECTION FOR WORK AND DELIVER SAME TO ARCHITECT BEFORE REQUEST FOR ACCEPTANCE AND FINAL PAYMENT FOR WORK.5.DRAWINGS ARE DIAGRAMMATIC IN NATURE. SIZES AND LOCATIONS OF PIPING ARE INDICATED, BUT IT IS NOT INTENDED TO SHOW EVERY OFFSET ORFITTING OR EVERY STRUCTURAL DIFFICULTY THAT MAY BE ENCOUNTERED DURING INSTALLATION OF THE WORK. THE ALIGNMENT OF PIPING SHALL BEVARIED FROM THAT INDICATED ON THE DRAWINGS WITHOUT EXTRA EXPENSE TO THE OWNER WHERE NECESSARY TO AVOID STRUCTURAL ORMECHANICAL DIFFICULTIES, OR TO AVOID THE WORK OF ANY OTHER TRADES.6.CHECK AND VERIFY ALL DIMENSIONS, SITE CONDITIONS, DRAWINGS AND SPECIFICATIONS. REPORT ANY AND ALL DISCREPANCIES TO THEARCHITECT AT ONCE.7.PERFORM LABOR IN A THOROUGH AND COMPLETE WORKMANLIKE MANNER AND WITH ALL REASONABLE RAPIDITY TO THE SATISFACTION OF THEARCHITECT.8.PERFORM ALL NECESSARY EXCAVATION, SHORING AND BACKFILLING REQUIRED FOR THE PROPER LAYING OF ALL PIPES AND CONDUITS INSIDE THEBUILDING AND PREMISES, AND OUTSIDE AS MAY BE NECESSARY. PIPING IN TRENCHES AT THE INTERIOR OF THE BUILDING SHALL BE PROPERLYBEDDED ON A SUITABLE AMOUNT OF GRAVEL OR SAND FOR A SUBSTANTIAL INSTALLATION, WITH PIPING NOT RESTING ON STONES OR ROCK.9.CUT COMPLETED CONSTRUCTION WORK ONLY IF SLEEVES, OPENINGS, CHASES, ETC., WERE INADVERTENTLY OMITTED AND ONLY WITH THE SPECIFIEDAPPROVAL OF THE ARCHITECT.10.ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. SHOULD ANY VARIANCE BETWEENPLANS AND SPECIFICATIONS OCCUR WITH THESE INSTRUCTIONS, THE ARCHITECT OR ENGINEER SHOULD BE CONTACTED IMMEDIATELY SO THAT ANYVARIATIONS IN INSTALLATION CAN BE KNOWN BY ALL PARTIES CONCERNED.11.EACH COMPLETED SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE OF THE WORK BY THE OWNER,THE CONTRACTOR SHALL GUARANTEE EACH SYSTEM IN WRITING TO BE FREE OF DEFECTS OF MATERIALS AND WORKMANSHIP AND TO PERFORMSATISFACTORILY UNDER ALL CONDITIONS OF LOAD OR SERVICE.12.DETERMINE IN ADVANCE OF CONSTRUCTION THE LOCATION ALL PIPING, SLEEVES, HANGERS, FLOW LINE ELEVATIONS, ETC. INSTALL PIPINGSUBSTANTIALLY AS INDICATED, PARALLEL WITH THE BUILDING WALLS, UNLESS INDICATED OTHERWISE.13.WHERE PIPING PASSES THROUGH SUCH BUILDING ELEMENTS AS WALLS, FLOORS, ROOFS, FOOTINGS, ETC., PROVIDE 22 GAUGE GALVANIZED STEELSLEEVES UNLESS INDICATED OTHERWISE. SLEEVES FOR INSULATED PIPING SHALL BE LARGE ENOUGH FOR INSULATION. PROVIDE CHROME PLATEDESCUTCHEONS AT PENETRATIONS THROUGH ALL FINISHED AREAS.14.SUPPORT HORIZONTAL PIPE WITH VERTICALLY ADJUSTABLE HANGERS ON SWIVEL RING OR CLEVIS TYPE HANGER SUSPENDED ON THREADED STEELROD HANGERS.15.ALL VALVES SHALL BE DESIGNED FOR 125 PSI MINIMUM WORKING PRESSURE. ALL WATER VALVES SHALL BE BALL VALVES UNLESS OTHERWISESPECIFIED OR REQUIRED FOR SPECIAL INSTALLATION OF FLOW CONTROL. BALL VALVES SHALL BE BRONZE WITH CHROME-PLATED BALL, TEFLONSEALS AND LEVER HANDLE WITH PLASTIC GRIP, SOLDER ENDS. ALL WATER VALVES SHALL BE OF THE SAME MANUFACTURE EXCEPT AS NOTED. ALLVALVES SHALL BE TAGGED WITH SERVICE DESIGNATION.16.PROVIDE VALVES AND UNIONS ON EACH HOT AND COLD WATER CONNECTION TO EACH FIXTURE OR PIECE OF EQUIPMENT WHICH DOES NOT HAVESTOP VALVE SPECIFIED.17.DOMESTIC WATER PIPING ABOVE GROUND SHALL BE TYPE L COPPER, ASTM B-88, WITH ANSI B-16 CLASS 150 WROUGHT COPPER OR CAST BRONZESOLDER FITTINGS.18.HOT & COLD WATER PIPING BELOW GROUND SHALL BE AQUA PEX TUBING MANUFACTURED TO CTS-OD SIZES WITH A STANDARD THICKNESS OFSDR-9 AND APPROVED FOR POTABLE WATER. FITTINGS SHALL BE CAST BRASS OF SUITABLE FOR INSERTION CONNECTIONS USING A COPPERCRIMP RING OVER THE PEX PIPE. INSULATE ALL PIPING WITH MINIMUM 1/2 INCH CLOSED CELL ELASTOMERIC THERMAL INSULATION AS MANUFACTUREDBY AEROCELL OR EQUAL AS APPROVED BY OWNER. INSULATION SHALL BE NOTED ON MANUFACTURER'S SUBMITTAL DATA SHEET TO BEAPPROVED FOR BELOW GROUND INSTALLATION.19.DOMESTIC COLD, HOT AND HOT WATER RETURN PIPING SHALL BE INSULATED WITH 1" THICK FIBERGLASS INSULATION. CLOSED CELL ELASTOMERICAND POLY BASED INSULATION IS NOT PERMITTED. INSULATION THAT IS EXPOSED, SHALL BE 1" THICK FIBERGLASS WITH A cleanable, dimple andwrinkle resistant all-service jacket composed of aluminum foil, reinforced with a glass scrim bonded to a kraft paperinterleaving with an outer film leaving no paper exposed (25/50 rated, ul723) - KNAUF EW 1000 WITH ASJ+.20.DOMESTIC WATER PIPING SHALL BE PRESSURE TESTED AND PROVEN TIGHT WITH A MINIMUM OF 100 PSI HYDROSTATIC TEST. NOTIFY ARCHITECTPRIOR TO TESTING. FINAL APPROVAL SHALL BE BY THE CITY INSPECTOR.21.SANITARY DRAIN, VENT AND CONDENSATE PIPES UNDERGROUND SHALL BE PVC DWV SCHEDULE 40 PIPE, ASTM D2665 WITH SOLVENT-CEMENTJOINTS CONFORMING TO ASTM F-656 AND ASTM D-2564. FITTINGS SHALL BE PVC DWV, SCHEDULE 40 IPS, ASTM D2665 SUITABLE IN EVERY WAY FORDRAINAGE AND VENT PURPOSES, OF THE SAME WEIGHT AS THE PVC DRAIN PIPE. piping at coffee brewers as indicated on p-2 shall becoated service weight cast iron soil pipe, astm a-74, hub and spigot; coated extra heavy where required by code. all cast ironsoil pipe and fittings shall be marked with the collective trademark of the cast iron soil pipe institute (cispi) and be listed bynsf international. use 45 degree or long turn fittings.22.SANITARY DRAIN, VENT AND CONDENSATE PIPE ABOVE GROUND SHALL BE PVC DWV SCHEDULE 40 PIPE, ASTM D2665, FOR SIZES 1-1/2" ANDSMALLER. FITTINGS SHALL BE PVC WITH SOLVENT WELD JOINTS. SIZES 2" AND LARGER SHALL BE THE SAME AS SPECIFIED FOR SANITARY PIPEBELOW GROUND.23.SLOPE HORIZONTAL SOIL PIPES UNDER BUILDING 1/8" PER FOOT FOR SIZES 4" AND ABOVE, EXCEPT THE 6" SOIL LINE SERVING THE RESTROOMS ANDSANITARY GREASE LINES SHALL BE SLOPED AT 1/4" PER FOOT AND 1/4" PER FOOT FOR SIZES LESS THAN 4". SLOPE SHALL BE UNIFORM AND FREEOF DIPS, TRAPS, ETC.24.TEST SANITARY DRAIN AND VENT PIPING UNDER A WATER PRESSURE EQUIVALENT TO A 10 FOOT HEAD OF WATER ABOVE THE HIGHEST DRAINOPENING FOR NO LESS THAN 15 MINUTES, WITH NO LOSS. NOTIFY ARCHITECT PRIOR TO TESTING. APPROVAL SHALL BE BY THE ARCHITECT, CITYINSPECTOR OR BOTH AS DIRECTED.25.ABOVE GRADE CONDENSATE DRAIN PIPING ASSOCIATED WITH COOLERS AND FREEZERS SHALL BE COPPER TUBING, SEAMLESS HARD DRAWN,ASTM B-306, TYPE DWV. WITH ANSI B-16 WROUGHT COPPER OR CAST BRONZE SOLDER DRAINAGE FITTINGS. PROVIDE HEAT TAPE (36 WATT PERLINEAL FOOT) AND 1/2" THICK FIBERGLASS INSULATION FOR ALL DRAINS LOCATED INSIDE FREEZERS. SET DRAINS SECURELY AND 3/4" CLEAR OFWALLS. PROVIDE 1/2" THICK INSULATION ON COPPER CONDENSATE DRAIN PIPING OUTSIDE OF COOLERS AND/OR FREEZERS. INSULATION THAT ISEXPOSED SHALL HAVE A cleanable, dimple and wrinkle resistant all-service jacket composed of aluminum foil, reinforced with aglass scrim bonded to a kraft paper interleaving with an outer film leaving no paper exposed (25/50 rated, ul723) - KNAUF EW1000 WITH ASJ+. CLOSED CELL ELASTOMERIC AND POLY BASED INSULATION IS NOT PERMITTED.26.PROVIDE NEW FIXTURES, DRAINS AND OTHER PLUMBING EQUIPMENT AS SPECIFIED HEREIN AND ON PLANS AND INSTALL TO OPERATE AS INTENDED.27.CLEAN OUTS FOR CONCRETE AND TILE FLOORS SHALL BE ZURN 1400, LACQUERED CAST IRON, TWO PIECE BODY, HEAVY DUTY NICKEL-BRONZESQUARE SCORIATED COVER WITH VANDAL PROOF SCREW. CLEAN OUTS FOR WALLS SHALL BE ZURN 1443, LACQUERED CAST IRON BODY,NICKEL-BRONZE SQUARE SCORIATED COVER WITH VANDAL PROOF SCREW. CLEAN OUTS SHALL BE FULL SIZE, ACCORDING TO THE LINE THEY INWHICH THEY ARE INSTALLED.28.WATER HAMMER ARRESTORS SHALL BE STANDARD PRODUCTS AS MANUFACTURED BY ZURN, PRE CHARGED, SIZED IN ACCORDANCE WITH PDIWH-201. A WATER HAMMER ARRESTOR SHALL BE INSTALLED WHERE QUICK-CLOSING VALVES ARE UTILIZED.29.ALL EXPOSED PIPING AND FITTINGS SHALL BE CHROME PLATED OR STAINLESS STEEL, CONFORMING TO ASTM A120, A53, OR A106.30.PROVIDE THE PROPER SIZE BACKFLOW PREVENTER VALVE WHEN REQUIRED BY CODES, ARCHITECT OR ENGINEER. EACH FOOD SERVICE PIECEOF EQUIPMENT SHALL BE PROVIDED WITH A BACKFLOW DEVICE LISTED ON THE MUNICIPALITIES BACKFLOW PREVENTER APPROVAL LIST ANDCONFORM TO A.S.S.E. 1012, A.S.S.E. 1022, A.S.S.E. 1024, A.S.S.E. 1025, or a.s.m.e. 112. EXTEND DRAIN CONNECTION FROM BACKFLOW PREVENTERDEVICES with pex tubing AND TERMINATE OVER CLOSEST DRAIN WITH APPROVED AIR GAP.31.COORDINATE SLEEVE AND LINTEL SIZES, LOCATIONS, AND ELEVATIONS THROUGH THE FOUNDATION AND EXTERIOR WALL WITH THE GENERALCONTRACTOR. 32.GAS PIPING SHALL BE SCHEDULE 40, SEAMLESS, BLACK STEEL PIPE, ASTM A53, GRADE B, WITH BLACK MALLEABLE FITTINGS. COLOR CODE GASPIPING: APPLY 16" YELLOW BAND WITH BLUE WORD "GAS" STENCILED ON CENTER OF NEW PIPING RUN AND AT VALVES, RUST-OLEUM NO. 659 YELLOWAND NO. 721 BLUE. PROVIDE GAS DIRT LEGS AT LOW POINTS. INSTALL PIPING IN ACCORDANCE WITH RULES AND REGULATIONS OF LOCAL GASCOMPANY SERVING THE BUILDING. GAS PIPING LOCATED ON ROOF and within building SHALL BE PAINTED YELLOW AND PIPING ON SIDE OFBUILDING SHALL MATCH THE WALL EXTERIOR.MARK EXPOSED, CONCEALED GAS PIPING, EXTERIOR, ON ROOF: APPLY A YELLOW BAND WITH THE WORD "GAS" AT CENTER OF BAND, OR LABELPIPING BY STENCILING THE WORD "GAS" IN BLACK LETTERING. BANDS SHALL BE PLACED ON CENTER OF NEW PIPING RUN AND AT VALVES.MARKERS SHALL BE W.H. BRADY COMPANY B-350 PERMA-CODE THIN FILM PIPE MARKERS, OR EQUAL.GAS VALVES 2" AND SMALLER FOR THE GAS SYSTEM SHALL BE THE NIBCO NO. T-585-70-UL (FULL PORT) OR T-580-70-UL (CONVENTIONAL PORT)#"--7"-7&*/"$$03%"/$&8*5)1*1&4*;&4"10--08"554)"..0/%03"11307&%&26"-5)&/*#$07"-7&4)"--*/$-6%&5801*&$&BRONZE OR BRASS BODY, CHROME PLATED BRONZE BALL, BLOWOUT-PROOF STEM, REINFORCED TFE SEATS, UL LISTED FOR NATURAL GAS (ALSO-1("40*-$0.13&44&%"*3"/%'-".."#-&-*26*%4 5)3&"%&%&/%48*5)"."9*.6.803,*/(13&4463&0'14*(5)&.*-8"6,&&7"-7&#655&3'-:7"-7&.0%&-##4&3*&48*5)#30/;&#0%:"/%45"*/-&4445&&-%*4$"/%45&.8*--#&"$$&15"#-&7"-7&SHALL BE AGA CERTIFIED FOR 8 OUNCE GAS PRESSURE AND UL LISTED FOR NATURAL GAS RATED AT 175 PSI MAXIMUM.33.THE CONTRACTOR SHALL PROVIDE CAP FOR FUTURE ELECTRIC SOLENOID-OPERATED GAS VALVE TO SERVE THE FUTURE GAS FRYER. THE FUTURESOLENOID SHALL BE 2-WAY, OF ALUMINUM CONSTRUCTION, NORMALLY CLOSED TYPE, MANUAL RESET, THE ASCO NO. 8044A SERIES, ATKOMATICVALVE COMPANY, INC., MERCOID, OR APPROVED EQUAL.34.SANITARY TEES AND DOUBLE WYES ARE NOT PERMITTED. OFFSET WYES SHALL BE USED.35.PIPING INVERT ELEVATIONS SHOWN ON THE PLUMBING DRAWING P-2 ARE BASED ON THE FINISHED FLOOR ELEVATION OF (0.00') REFERENCE.UNLESS NOTED OTHERWISE.36.AT ALL FLOOR DRAINS, FLOOR SINKS AND WASTE RECEPTORS RECEIVING INDIRECT WASTE:  WHERE NECESSARY TO SUPPORT INDIRECT WASTEPIPING, INSTALL PRE-MANUFACTURED AIR GAP DEVICE AS MANUFACTURED BY TRU-GAP, NORTH ST PAUL, MN, IN ORDER TO PROVIDE THE AIRGAP REQUIRED BY CODE.37.COORDINATE ENTIRE GAS SERVICE INSTALLATION WITH UTILITY AND ANY ADDITIONAL REGULATORS ARE PROVIDED BY THE CONTRACTOR.38.DISINFECT DOMESTIC WATER SYSTEM IN ACCORDANCE WITH AUTHORITY HAVING JURISDICTION. PREPARE AND SUBMIT REPORTS TO OWNERINDICATING WATER IS SAFE FOR HUMAN CONSUMPTION..NO SCALERSM4772-R-P1P-1PLUMBING NOTES 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 HOT WATER PIPINGCOLD WATER PIPINGSANSANITARY WASTE PIPINGDROP IN PIPINGCO.RISE IN PIPINGFLOOR CLEANOUTPLUMBING LEGENDDETAILDESCRIPTIONFFILTERED WATERIMFICE MAKER FEEDER LINECDLCONDENSATE DRAIN LINESANITARY STORM LINETPTRAP PRIMER PIPINGGREASE SANGREASE SANITARY WASTE PIPINGHWCWPLUMBING FOUNDATION NOTES:1.PLAN IS DIAGRAMMATIC IN NATURE AND IS NOT INTENDED TO SHOW EACH ANDEVERY OFFSET, FITTING, ETC. PLUMBING CONTRACTOR SHALL COORDINATE PIPEROUTING WITH OTHER TRADES AND MAKE NECESSARY ROUTING REVISIONS ASCONSTRUCTION CONDITIONS REQUIRE.2.THE PLUMBING CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF PIPINGPENETRATIONS THROUGH THE FOUNDATION WALL WITH THE GENERAL CONTRACTOR.PENETRATIONS SHALL BE SLEEVED WITH GALVANIZED STEEL.3.WHERE EXCAVATIONS FOR PIPING EXTEND UNDER AND PERPENDICULAR TO WALLFOOTING, THE CONTRACTOR INSTALLING THE PIPING SHALL FILL THE TRENCH WITHCONCRETE SOLIDLY TO THE BOTTOM OF FOOTING FOR A TRENCH LENGTH OF 3'-0"BEYOND EACH WALL FACE.4.FLOOR DRAINS SHALL BE PROVIDED WITH TRAP PRIMER CONNECTIONS, TRAPPRIMER VALVES, AND ALL NECESSARY PIPING AND CONNECTIONS, WHERE NOTED.5.COORDINATE ALL UTILITIES WITH SITE PLAN, AND BRING ANY CONFLICTS TO OWNER'SATTENTION. VERIFY LOCATIONS OF WATER AND SANITARY SEWER SERVICES. VERIFYDEPTH OF SANITARY SEWER CONNECTIONS.6.SEE WASTE AND VENT RISER DIAGRAM ON SHEET P-6, FOR MORE INFORMATION.7.COORDINATE THE EXACT LOCATION OF GREASE INTERCEPTOR WITH THE SITE PLAN.FIELD VERIFY LOCATION OF GREASE INTERCEPTOR.8.ALL SANITARY SEWER AND VENT LINES BELOW THE SLABS SHALL BE 4" MIN., UNLESSNOTED OTHERWISE. 4" PIPES SHALL EXTEND ABOVE THE SLAB, WITH TRANSITIONS TOSMALLER SIZES MADE ABOVE SLAB.9.OUTSIDE WALL DIMENSIONS ARE FROM inSIDE FACE OF 10" CMU.10.FILTERED WATER PIPING UNDER FLOOR SLAB SHALL BE PEX TUBING APPROVEDFOR POTABLE WATER.11.PIPE INVERT ELEVATIONS ARE APPROXIMATE AND SHALL BE ADJUSTED ASREQUIRED DURING CONSTRUCTION TO ACCOMMODATE ACTUAL SITE CONDITIONS.12.REFER TO P-3 FOR ROUGH-IN DIMENSIONS.WALK-INCOOLERWALK-INFREEZERTAKE-HOMECOOLER8'-4"SALESAREA 210'-0"KITCHEN11'-0"10'-0"CHECK STAND9'-6"WALK-INTAKE-OUTCOOLERSEATING AREA11'-0"VESTIBULE11'-8"9'-6"UTILITY ROOM9'-6"MEN9'-6"WOMEN8'-0"SALES AREA 18'-0"7'-8"8'-0"10'-0"up8'-0"EMPLOYEEUTILITY SPACE9'-6'work room8'-0"office2000 gallonGREASEinterceptorTP4" UPTO CO4" UPTO CO3" UPTO FS3" UPTO FD1/2"TRAPPRIMERFROM ABV3" UPTO FS2"v-up2"v-upgrease SANgrease SANSAN4" UPTO CO4" UPTO COSAN2" CO2CONDUIT-from blw2"w UPTO SINK2" CO2 CONDUIT2" UPTO wr-22" UPTO wr-21/2" hw & cw up1/2"3/4" IMF uptoequipmentSAN3" UPTO wr4"2" V-UPINITIAL INVERTELEVATION: (-1.81'±)3" UPTO fsim f im f 3/4"im f3/4"4"SAN4"SAN1 1/2" F UP TOequipmentMANIFOLD1 1/2"F F IMFFFFCOCOFOR CONTINUATION REFERTO CIVIL DRAWINGS4" UPTO CO3"V UP WITH WCO18" ABOVEFINISHED GRADEON OUTSIDE OFBUILDING4" UPTO CO4" UPTO CO2"v-upCO3" UP TO FDW/ TRAPguard3" UP TO FDW/ TRAPguard4"W-UPto wc4"W-UPto wc2"W-UPto ur2"W-UPto lav2" v-UP3" W-UPto ms4" UPTO CO4" UPTO CO3" UPTO WR-23" UPTO WR-12"v-upSAN2"w UPTO SINK4"4"4"4"4"6"SLOPEAT 2%6"6"6"SLOPEAT 2%6"SAN-DN4"greasesan-dn3/4"HW & CW-FROM ABV3/4"1/2"1/2"HW &CW UP TOSINKF 3/4"3/4"4" UPTO CO2" UP TO SINK W/ AIRADMITTANCE VALVE2" UPTO WR-14"4"4"4"4"san-dn4" UPTO CO4" UPTO COSHEAR GATE AND SWINGCHECK VALVE (WHENREQUIRED)SLEEVE FOUNDATION WALLSHEAR GATE AND SWINGCHECK VALVE (WHENREQUIRED)SLEEVE FOUNDATION WALLSHEAR GATE AND SWINGCHECK VALVE (WHENREQUIRED)SLEEVE FOUNDATION WALLINVERTELEVATION:-2.85'±INVERTELEVATION: -2.72'±INVERTELEVATION: -1.46'±3"3"4"6"4"blwgrade6"CO2"W-UP3"CDL-UPCDL3"3"2"V-UPCDL4" UPTO CO3"CDL-UP3"3"3"CDLCDL 53"F3/4"4" 4"2" UPTO WR-14"4"4" UPTO CO2"v-up3" W-UPto ms2"w UPTO SINK3" UP TOFLOOR TROUGHSLOPE AT 2%BLW GRADE2FOR CONTINUATION OF4" drain line to stormrefer to civil drawings.4" DRAIN LINE FROMRPZ AIR GAP OUTLET3"w UPTO fd4" UPTO CO4"4"4"grease SAN4" UPTO CO3/4"F UP tocoffeebrewers3"CDL-UP3"1/2" cW UP TO SINK1/2" hW UP TO SINK3/4" F UP TOEQUIPMENT4"4"4"4"SANSAN INITIAL INVERTELEVATION: (-1.00'±)INITIAL INVERTELEVATION:(-1.00'±)SLOPEAT 2%SLOPEAT 2%SLOPEAT 2%SLOPEAT 2%2" UPTO wr-12" UPTO wr-14"4"4"4"2 1/2" GAS UPTO ROOF4PLUMBING KEYNOTES:CONTRACTOR SHALL COORDINATE ALL CONDUIT AND PIPING LOCATED IN THIS AREAWITHIN THE WALL WITH OTHER TRADES.4" BACKWATER VALVE FROM MAINLINE ADAPT-A-VALVE MODEL ML-4XP. PROVIDE6" DWV PIPE TO GRADE WITH CLEANOUT PLUG.INVERT ELEVATION OF 4" GREASE SANITARY (-1.56'±).INVERT ELEVATION OF 4" SANITARY (-2.06'±).sanitary piping in this area shall be cast iron. refer to p-1, note #21 foradditional information.3" BACKWATER VALVE FROM MAINLINE ADAPT-A-VALVE MODEL ML-3XP.PROVIDE 4" DWV PIPE TO GRADE WITH CLEANOUT PLUG.123452"v-up2"v-up4"4"4"5'-0"FOR CONTINUATION OF6" PVC STORM LINEREFER TO CIVILDRAWINGSBLW GRADEDSP4"DSP5'-0"FOR CONTINUATION OF4" PVC STORM LINE REFERTO CIVIL DRAWINGSHBUTW3/4"3/4" utw up3/4" utwfrom abv3/4"3/4"5'-0"DSPFOR CONTINUATION OF4" PVC STORM LINEREFER TO CIVILDRAWINGS5'-0"FOR CONTINUATION OF6" PVC STORM LINEREFER TO CIVILDRAWINGSDSPBLW GRADE4"6"6"312"v-up4"SAN SAN FOR CONTINUATION OF3" cdl to stormrefer to civildrawings4"4"4"4"4"4"4"4"4"4"4"4"4"5'-10"46'-11 1/4"31'-10"blwgrade6"COblwgrade6"blwgradeblwgradeAS NOTEDRSM4772-R-P2P-2IN SLAB PLUMBING PLAN 2017-0594x0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNET COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER S ON SEAL04300512-21-17 ROUGH IN PLUMBING PLANSCALE: 1/4" = 1'-0"1'-11 1/4"4'-1 1/2"10'-4 1/4"13'-8 1/4"14'-5 3/4"15'-2 1/4"4'-9 3/4"1'-7 1/2"1'-3 1/4"4'-8 3/4"5'-10 1/2"5'-10 1/2"6'-9 1/2"7'-8"10'-3"10'-9"14'-5 3/4" 13'-11 3/4" 14'-11 1/4" 14'-10 1/2"14'-10"21'-5 1/2"22'-0 3/4"22'-6"23'-4"2 1/4"3 3/4"1'-5 1/4"9'-6 1/4"22'-0"20'-5 3/4" 29'-7"23'-11"24'-2 3/4" 23'-8 1/4"24'-3"23'-8 1/2"23'-1"24'-8 3/4"23'-5"12'-1"2"18'-2 1/4"15'-5 3/4"7'-0 3/4"9'-10 1/2"11'-10"12'-8 1/4"12'-2 1/2"18'-10 3/4"16'-6 1/2"20'-6"14'-4 1/4"22'-5"24'-9 1/2"34'-8 3/4"6'-1 1/2"33'-11 3/4"15'-9" 18'-5"27'-2"30'-5 1/4"20'-0 1/2" 22'-3 1/2" 24'-2 1/4" 25'-6 3/4"9'-1 1/4"10'-0"13'-2 1/2"10'-10 1/2"27'-4 3/4" 28'-4 1/4" 29'-0"20'-9 1/4"21'-6 3/4"24'-3 1/2"29'-2 1/2" 28'-4 1/4"32'-2"30'-8 1/4"21'-0 1/2"23'-8"17'-7 1/4" 17'-2 1/2" 15'-9 1/4" 15'-3" 14'-4 3/4" 12'-0" 2'-7 1/4"26'-3 1/4"26'-9"35'-1 3/4"29'-2"25'-3 1/2"23'-3"8'-6 1/2"4'-3 3/4"38'-2 3/4" 31'-8 3/4"6 3/4"5'-9 1/2"7'-6 1/4"10'-0"1'-10" 4'-3 3/4" 4'-8" 5'-0 1/4" 5'-4 1/2" 5'-9" 6'-0 1/2"19'-11"20'-4 1/4"23'-6"26'-9"7'-11 1/4" 9'-1" 1'-7 3/4" 7'-11 1/4"37'-2"10'-10 1/4" 9'-8 1/4"36'-0"39'-5 3/4"15'-8 1/4" 14'-7 1/4" 14'-2"45'-6 3/4"45'-11"14'-10" 14'-11 3/4"46'-1 1/4"46'-2 1/2"12'-2"29'-1"4" UPTO co4" UPTO CO3" UPTO FS2"v-up4" UPTO CO3"V UP WITH WCO18" ABOVEFINISHED GRADEON OUTSIDE OFBUILDING4" UP TO CO4" UPTO CO3" UP TO FD W/TRAP guard3" UP TO FDW/ TRAPguard4"W-UPto wc4"W-UPto wc2"W-UPto ur2"W-UPto lav2" v-UP3" W-UPto ms4" UPTO CO4" UPTO CO3" UPTO WR-23" UPTO WR-12"v-up2"w UPTO SINK4" UPTO CO2" UP TO SINK W/ AIRADMITTANCE VALVE2" UPTO WR-14" UPTO CO2"W-UP3"CDL-UP2"V-UP3"CDL-UP2" UPTO WR-14" UPTO CO2"v-up3" W-UPto ms3"w UPTO fd4" UPTO CO3/4" F UP TOEQUIPMENT3/4" utwfrom abv2"v-up4" UPTO CO3" UPTO FS3" UPTO FD1/2"TRAPPRIMERFROMABV2"v-up4" UPTO CO4" UPTO CO2"w UPTO SINK2" CO2 CONDUIT2" UPTOwr-22" UPTO wr-21/2" hw &cw up3/4" IMF uptoequipment3" UPTO wr2" V-UP3" UPTO fs1 1/2" F UP TOequipmentMANIFOLD4" UPTO CO4" UPTO CO4" UPTO CO2"w UPTO SINK3" UP TO FLOOR TROUGH4" UPTO CO2" UPTO wr-12" UPTO wr-12"v-up2"v-up3/4" utw up2"W-UPto ur2"v-UP2"v-UP1/2" cW UP TO SINK1/2" hW UP TO SINK1/2"HW &CW UP TOSINK3/4"F UP tocoffeebrewerswater filter1/2"38'-11 3/4"39'-4 3/4"2"v-up2"v-upAS NOTEDRSM4772-R-P3P-3ROUGH IN PLUMBING PLAN 2017-0594x0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNET COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER S ON SEAL04300512-21-171-4-17 dja code review comments1 ABOVE SLAB PLUMBING PLANSCALE: 1/4" = 1'-0"HBWR-1WR-1WR-1SEE ENLARGEDPLAN THIS PAGE3" UP TOFLOORTROUGHWC-2WC-2WC-1URURLAVLAV1/2"1/2"SOV1 1/2"1/2"hw TOINDIVIDUALGOOSENECKFAUCET WITHINTEGRAL VACUUMBREAKER (redrinser)WR-1WR-1wr-2wr-2FDFS1 1/2" TO FS3FS1/2" F TOESPRESSOMACH.3/4"F TOCOFFEEBREWERS3/4"F WATER MANIFOLDREFER TO DETAIL1/2" HW & CWTO HOSE REELHS-11/2"HW & CWDOWN TO SINK.1/2"F TODRINKINGFOUNTAINS2"VTO DFF PROVIDETRAPGUARDPROVIDETRAPGUARD3"VTRHB3/4"1"1 1/2"3"3"3"4CDL1 1/4"SANITARY DRAIN PIPING FORSOFT HEAT BREWERS SHALL BE1" TYPE K COPPER FROM DRAINCONNECTION OF TROUGH TOABOVE WASTE RECEPTOR WITHAPPROVED AIR break.WHA.HS-11 1/2"F to equipmentMANIFOLDREFER TO DETAIL(4) 5" CONDUITS FORSYRUP AND CO22THE INDIRECT WASTE LINESFROM EQUIPMENT SHALLTERMINATE SEPARATELYOVER waste recptor WITHAPPROVED AIR gap.HS-1CCS3"1 1/4"42"V-FROMBLW3"VTR2" V UPFROM BLW2" V UPFROM BLWWR-1WR-23/4" IMF FROMBELOW TO 8.123"VTR3"V 3/4"3/4"(4) 5" CONDUIT FORSYRUP and co223"VTR4" WATER HEATERFLUE AND INTAKETHROUGH ROOF7SSFUTURE11/2"1/2"1/2" HW & CWTO SINKVENTING TYPES·INDIVIDUAL VENTS SERVING ALL FIXTURES EXCEPTTHE TYPES AND LOCATIONS BELOW:·COMBINATION DRAIN AND VENT SYSTEM SERVINGFLOOR DRAIN(S), FLOOR SINK(S) AND WASTERECEPTOR(S) IN SALES AREA.·AIR ADMITTANCE VALVES SERVING SINKS NOTEDON THIS DRAWING.hwrutwhwfs1" type k copper fromdrain connection oftrough to above wastereceptor withapproved air gap.3/4" hw & CW tobelow slabutwutwutw 1/2"cw & hw up fromblw to mixing valvefor wand. Wandfurnished by owner.2" CO2 CONDUITFROM TANKCDL CO1 1/4"cdl2" UPTO SINK2"V-UPdsextend drain lines frombackflow preventors andTERMINATE SEPARATELYOVER waste receptor WITHAPPROVED AIR gap.SINK SHALL BE DIRECTLYCONNECTED TO SANITARY2"W UP TO SINK WITH AIRADMITTANCE VALVE1/2" hw & CWUP TO SINK3/4"F WATER TOEQUIPMENT MANIFOLDrefer to detailWR-14CO4CDLCO1 1/4"1 1/4"1 1/4"4WRPLEASE NOTE BEFORE ASSEMBLY:·ATTACH FAUCET TO SINK PERFAUCET INSTRUCTIONS.·REMOVE THE NYLON LOCKINGNUTS FROM UNDERSIDE OFHAND SINK AND SET ASIDE.·PLEASE FOLLOW THE PLUMBINGROUGH-INS. ALL DIMENSIONSARE NOMINAL.EAGLE SINK DETAILSCALE: NO SCALE34" WORKING HEIGHT DIMENSIONS FORPLUMBING ROUGH-INS:8-1/2" CENTER OF DRAIN24 1/2" CENTER OF TRAP 28 1/2" WATER INLETFD.FLOOR DRAINFSFLOOR SINKHOT WATER PIPINGCOLD WATER PIPINGVENT PIPINGDROP IN PIPINGCO.RISE IN PIPINGFLOOR CLEANOUTWCO.WALL CLEANOUTPLUMBING LEGENDDETAILDESCRIPTIONFILTERED WATERICE MAKER FEEDER WATERFHOT WATER RETURN PIPINGWR-1/wr-2WASTE RECEPTORIMFVTRAP PRIMER LINETPTPTRAP PRIMER VALVECONDENSATE DRAIN LINECDLBALANCING VALVECWHWHWRWATER HAMMER ARRESTORWHA.UNTREATED WATERUTWgas shut-off valveDM103"3"3"3/4" utw-dn3/4" utwfrom blw2" CO2CONDUIT-DN9111" to 3/4" reducer1"1/2"1/2"hw & CWUP TO SINK8885T P 1/2" trapprimer line-dnWR'S SERVINGCOFFEE LINESHALL BECAST IRON2" V UPFROM BLWPLUMBING FLOOR PLAN NOTES:1.PLAN IS DIAGRAMMATIC IN NATURE AND IS NOT INTENDED TO SHOW EACH AND EVERY OFFSET,FITTING, ETC. PLUMBING CONTRACTOR SHALL COORDINATE PIPE ROUTING WITH OTHER TRADES ANDMAKE NECESSARY ROUTING REVISIONS AS CONSTRUCTION CONDITIONS REQUIRE.2.PLUMBING CONTRACTOR SHALL COORDINATE CONNECTIONS TO EQUIPMENT WITH ARCHITECT ANDEQUIPMENT SUPPLIER.3.SEE SANITARY DRAIN AND VENT RISER DIAGRAM (SHEET P-6) FOR PIPE SIZES NOT SHOWN ON THISPLAN.4.SHEETZ SHALL FURNISH AND PLUMBING CONTRACTOR SHALL INSTALL ANDERSON BRASS ABF-ILL,A.S.S.E. 1022 COMPLIANT BACKFLOW PREVENTER, ON ALL BEVERAGE DISPENSING EQUIPMENTINCLUDING ICE MACHINES. BACKFLOW PREVENTER ON FOUNTAIN IS FURNISHED AND INSTALLED BYMANUFACTURER.5.CONTRACTOR SHALL TERMINATE VENTS THROUGH ROOF NO LESS THAN 15' AWAY FROM ANYMECHANICAL EQUIPMENT INTAKE.6.ALL CONDENSATE DRAIN LINES ABOVE GRADE PROVIDED BY REFRIGERATION CONTRACTOR.7.WHERE EXPOSED PIPES AND CONDUITS ARE NECESSARY, THEY SHOULD BE MOUNTED 1 TO 2 INCHESOFF THE WALL AND 6 INCHES OFF THE FLOOR TO ALLOW FOR CLEANING.1143/4"hw dn to ms-11/2"hw up in wallto above ceiling1/2"hw dnto lav3/4"1/2"hwr up inwall to aboveceilingDROP126WALK-INCOOLERWALK-INFREEZERTAKE-HOMECOOLER8'-4"SALESAREA 210'-0"KITCHEN11'-0"10'-0"CHECK STAND9'-6"WALK-INTAKE-OUTCOOLERSEATING AREA11'-0"VESTIBULE11'-8"9'-6"UTILITY ROOM9'-6"MEN9'-6"WOMEN8'-0"SALES AREA 18'-0"7'-8"8'-0"10'-0"up8'-0"EMPLOYEEUTILITY SPACE9'-6'work room8'-0"office2" V UPFROM BLW3"1/2"hwr upin wall toabv ceilingHB2"3/4"AbCD1/2" HW & cwDOWN TODISHWASHER21ms-1water filter2"17CoSOVSOV2"2" V UPFROM BLW2" V UPFROM BLWBALANCING VALVE SET@ 1/2 GPM (ADJ)1/12 HP CIRC PUMPSTRAINERCHECK VALVECoutwCOff2" V UPFROM BLW4" RPZDRAIN LINE102" WATER SERVICELINE UP FROM BELOWdrop132" V UPFROM BLW1/2" IMF -DNSEE ENLARGEDPLAN THIS PAGE1/2" hw & CWUP TO SINKW/THERMOSTATICMIXING VALVE1/2" hw & CWUP TO SINKW/THERMOSTATICMIXING VALVESEE ENLARGEDPLAN THIS PAGE1"1"FD20PLUMBING KEYNOTES:CONTRACTOR SHALL COORDINATE ALL CONDUIT AND PIPING LOCATED IN THIS AREA WITHIN THE WALLWITH OTHER TRADES.REFER TO DRAWING E-2 FOR ROUTING OF CONDUIT. CONDUIT PROVIDE BY E.C..EACH INDIRECT WASTE LINE FROM THE THREE BOWL SINK SHALL TERMINATE INDIVIDUALLY OVERFLOOR SINK WITH APPROVED AIR break. INDIRECT WASTE SHALL NOT BE MANIFOLDED.PROVIDE 3/4" trap and union.ICE MAKER TRANSPORT TUBE SHALL BE INSULATED WITH 1/2" THICK INSULATION AND INSTALLED PERMANUFACTURER'S RECOMMENDATIONS.ALL VALVES ON THIS WALL SHALL BE ACCESSIBLE THRU THE ACCESS PANEL.HOSE BIB SHUT-OFF VALVES TO BE MOUNTED ON WALL BELOW CEILING OF JANITORS ROOM. PROVIDEPERMANENT TAGS ON EACH VALVE INDICATING FIXTURE AND LOCATION.direct connect 1 1/4"cdl to 3"cdl at floor.provide 1" drain lines from follet machine to wr with approved air gap via air gapfitting. wr at this location shall be installed minimum 3" above top of cooler.3/4" STEEL FRYER OIL PIPE, TERMINATE PIPE MAXIMUM 72" ABOVE GRADE.SLOPE AT 1/4" PER FT (2%) TO EXTERIOR TANK.1/2" HW & CW up TO MIXING VALVE. PROVIDE A WATTS 1/2" LFUSG-B-M2 MIXING VALVE TO SUPPLYTEMPID WATER TO WAND. WAND FURNISHED BY OWNER. COORDINATE ACCESS DOOR WITH GC. REFERTO DETAIL.ASME RATED THERMAL EXPANSION TANK.1/2" HW & CW UP TO SINK W/THERMOSTATIC MIXING VALVE.piping is shown for diagramatical purposes. provide piping tight to the wall.1/2" trap primer line-dn.1/2" drain line down from roof drain. extend and terminate over mop sink with approvedair gap. provide 3/4"utw with valve above ceiling for roof hyDrant (rh-1).provide proset OR sure seal trap guard.1"G CAPPED AT CEILING FOR FUTURE GAS FRYER.1" G FROM ABOVE.PROVIDE 1/2" HW/CW QUICK DISCONNECT COUPLINGS FOR DISHWASHER CONNECTIONS123456789101112131415161718192021TO FILTEREDWATERFIXTURES (typ)WATER FILTER SYSTEMfiltered waterheaderSOVSOV1" HW TOFIXTURES3/4" CW hosebibbs andsinksasme rated THERMALEXPANSION TANK2" REDUCED PRESSURE ZONEBACKFLOW PREVENTER WITH AIRGAP DRAIN FITTING, WATTS LF009QTOR EQUAL. CONNECT & EXTEND 2"DRAIN LINE FROM AIR GAP FITTINGTO 4" RPZ DRAIN LINEPRESSURE REDUCING VALVE (PRV)WATER METER2"SOVIRRIGATION SYSTEM1" REDUCED PRESSURE ZONEBACKFLOW PREVENTER WITH AIRGAP DRAIN FITTING, WATTS LF009QTOR EQUAL. CONNECT & EXTEND 1"DRAIN LINE FROM AIR GAP FITTINGTO 4" RPZ DRAIN LINE1"1" IRRIGATION LINE SHALL BE EXTENDEDOUTSIDE BY PLUMBING CONTRACTOR.IRRIGATION CONTRACTOR SHALL CONNECTTO 1" LINE OUTSIDE OF BUILDING.COORDINATE EXACT DIMENSIONREQUIRED FOR IRRIGATIONSYSTEM CONTROLS WITHIRRIGATION CONTRACTOR.CONTROL SYSTEM TO BEINSTALLED IN THIS LOCATION.WATERHEATERSHALL BE PROVIDED IFCONNECTION IS MADEINSIDE OF THIS BUILDING.NOTE:PLUMBING CONTRACTOR SHALL PROVIDE REDUCEDPRESSURE ZONE BACKFLOW PREVENTER, WATTSMODEL NO. #LF009QT, WITH STRAINER ON WATERMAIN INSIDE THE BUILDING, INSTALLED UPSTREAM OFany equipment and branches. PIPING SHALL BEINSTALLED TO ALLOW ACCESS TO BACKFLOWPREVENTER FOR PROPER MAINTENANCE ANDSERVICE.1/2" HWR2 1/2" FACE LIQUID FILLED PRESSUREGAUGE - JONES STEPHENS CORP. MODELJ40-556 (TYP FOR ALL PRESSUREGAUGES UNLESS SPEC OTHERWISE) INPRESSURE PORT OF THE RPZPRESSURE GAUGE (TYP)bWATER SOFTENER VALVE SEQUENCESOFT WATER TO FILTER HEADER and hotwater ONLY OPEN VALVE A, B &D-CLOSE VALVE CSOFT WATER TO ENTIRE FACILITYOPEN VALVE A, C & D-CLOSE VALVE BNO SOFT WATER TO ENTIRE FACILITYOPEN VALVE B & C- CLOSE VALVE A & D1.2.3.Notes:1.P.C. SHALL PROVIDE PERMANENTTAGS ON VALVES.2.valves shall be installedbelow ceiling.3.sequence 3, no soft water toentire facility, to be used.1 1/2"3/4"1"2SR-BWSCALEINHIBITORCARTRIDGETO icemachines2 X 1-1/2 REDUCER1"1"2" waterserviceacdceilingceiling2" cw dntight to wall2" cw dntight to wall2"2"2" CW tofixtures2"2"2" by-passnormallyclosedpiping to be capped ifwater softener is notrequired. refer tonotes for sequence.union (typ)2"water service entrance detailSCALE: NO SCALE61515161818193" V UPFROM BLW3" V UPFROM BLW3"VTR2" V UP FROM BLW1 1/2"2"2" CO2 CONDUIT2"3/4"AbCDhb4"MS-1water filter2"17coBALANCING VALVESET@ 1/2 GPM (ADJ)STRAINER1/12 HP CIRC PUMPCHECK VALVEcoutwf2"v-up from blw4" RPZDRAIN LINE102" WATER SERVICELINE UP FROM BELOWDROP132" V UPFROM BLWFD1" G FROMABOVEFDFS1 1/2" TO FS (typ)3FS1/2"HW & CWDOWN TO SINK.1/2" F TOESPRESSO MACH.3"2" V UPFROM BLW3"V S1"G CAPPED AT CEILINGFOR FUTURE GAS FRYERFUTURE13"DM10111/2"trapprimerline-dn.T P10'-0"KITCHEN9'-6'work room1/2" HW & cwDOWN TODISHWASHER212" V UPFROM BLW16AS NOTEDRSM4772-R-P4P-4ABOVE SLAB PLUMBING PLAN ENLARGED KITCHEN PLANSCALE: 1/2" = 1'-0"1'4'2'0ENLARGED WORK ROOM PLANSCALE: 1/2" = 1'-0"1'4'2'02017-0594x0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNET COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 FLOWCLEAN OUT W/ CAST IRONHEAVY DUTY TRAFFICCOVER (LOcKING TYPE)AND BRONZE PLUGFINISHED GRADE16" SQUARECONCRETE PAD.6" THICK4" RISERSBUILDING SANITARY WASTEMAIN TO POINT OF CONNECTIONSIZE PER PLANMUSHROOM CAPHOUSE MAIN VENTBUILDING WALL4" MIN.WALL SLEEVEWALLPENETRATIONBUILDING DRAININVERT ELEVATIONPER PLAN8" DEEP HOUSE TRAP(INSTALL ONLY WHEREREQUIRED BY CODE)COVERFIN. FLOORPLUG IF END OF LINE1/8" BEND FULL SIZE, 4" MAX.RISERADJUSTING COLLARWASTE LINE1/8 BEND AT END OF LINE CLEANOUTWASTE LINE W/ LENGTH TO SUITPOLISHED S.S. ACCESS COVERCOUNTERSUNK SCREWCLEANOUT PLUGFOR WALL CONSTRUCT.SEE ARCH. DWGS.MAY EXTEND ASWASTE OR VENTCLEANOUT TEESANITARY PIPE -SEEPLAN FOR SIZEADJUSTABLE STRAINERGRATE TO BE ADJUSTEDTO BE FLUSH WITH TOP OFSLAB WITH 2 1/2" LONGSCREWSCONCRETE SLAB TO BE DEPRESSED1/2" DEEP x 24" RADIUS SET RIM OFFLOOR DRAIN FLUSH WITH SLAB ATFLOOR ELEVATIONDRAIN BODYNOTE:DRAIN BODY TO BEFLUSH W/ TOP OF SLABIN BOTTOM OF SWALE.SCALE:1P-5BUILDING TRAP DETAIL (WHEN REQ'D) N.T.S.SCALE:2P-5FLOOR CLEANOUT DETAIL N.T.S.SCALE:7P-5FLOOR DRAIN DETAIL N.T.S.SCALE:6P-5WALL CLEANOUT DETAIL N.T.S.11-12"INLET2"20" PVC CYLINDERCOPPER TUBE RISERSFORD HA31-323ANGLE CHECK VALVEFORD BA13-332WANGLE BALL VALVEFORD TYPE "W" WABASH DOUBLELID COVER WITH A 10" DEPTH(CATALOG NUMBER W3-TT)10"4" 50" 40" 48"SCALE:8P-5WATER METER PIT DETAIL(WHEN REQ'D) N.T.S.2" STYROFOAM PERIMETERINSULATION GLUED TOMETER PIT WALLSSCALE:3P-5WASTE RECEPTOR DETAIL (WR-1) N.T.S.4"-5"SCALE:4P-5WASTE RECEPTOR DETAIL (WR-2) N.T.S.1"-2"SEE PLAN FOR SIZEFINISHED FLOOREXTEND AND INSTALLOVER P-TRAP - P-TRAPSHALL BE SAME SIZE ASPIPEWR-1PIPE HUB - INSTALLAPPROXIMATELY 4"-5" ABOVEFINISHED FLOOR FOR ACCEPTINGINDIRECT WASTE PIPINGSCHEDULE 40 PVC PIPE WITHHUB END EXTENDED ABOVETHE FINISHED FLOORSEE PLAN FOR SIZEFINISHED FLOORPIPE HUB - INSTALLAPPROXIMATELY 1"-2" ABOVEFINISHED FLOOR FOR ACCEPTINGINDIRECT WASTE PIPINGTRU-GAP DEVICETUBING SUPPORTBASE OF CABINETMECHANICALLYSECURE TRU-GAPDEVICE TO TOP OFWASTE RECEPTORWASTE RECEPTOR - INSTALL ABOVE FINISHEDFLOOR OR ABOVE CABINET. REFER TO ELEVATIONVIEWS.SCALE:5P-5AIR GAP DEVICE DETAIL N.T.S.SCALE:9P-5AIR BREAK DETAIL N.T.S.FINISHED FLOOREXTEND AND INSTALL OVERP-TRAP - P-TRAP SHALLBE SAME SIZE AS PIPESCHEDULE 40 PVC PIPEWITH HUB END EXTENDEDABOVE THE FINISHED FLOORSCALE:10P-5AIR GAP DETAIL N.T.S.SEE PLAN FOR SIZEFINISHED FLOOREXTEND AND INSTALL OVERP-TRAP - P-TRAP SHALLBE SAME SIZE AS PIPESCHEDULE 40 PVC PIPE WITHHUB END EXTENDED ABOVETHE FINISHED FLOOREXTEND AND INSTALLOVER P-TRAP - P-TRAPSHALL BE SAME SIZE ASPIPESCHEDULE 40 PVC PIPEWITH HUB END EXTENDEDABOVE THE FINISHED FLOORSCHEDULE 40 PVC PIPEWITH HUB END EXTENDEDABOVE THE FINISHED FLOORFINISHED FLOORSEE PLAN FOR SIZEAIR GAP TO BE TWICETHE DIAMETER OF THEDISCHARGE LINEwr-2FLOWFLOOD LEVEL RIMWASTE RECEPTORDISCHARGE LINEFROM EQUIPMENTDISCHARGE LINEFROM EQUIPMENTFLOOD LEVEL RIMWASTE RECEPTORHOT WATER PIPINGPLUMBING LEGENDDETAILDESCRIPTIONHOT WATER RETURN PIPINGSOVSHUT-OFF VALVEGGDIRT LEG4" EXHAUST VENT (PVC)UNION (TYPICAL)WH-1TERMINATE ALL DRAIN LINES(EXCEPT CONDENSATE )OVER DRAIN PAN.CONDENSATE SHALLDISCHARGE OVER FLOORDRAIN WITH AIR GAP.DRAIN PAN UNDER WATERHEATER WITH DRAIN LINEEXTENDED TO FLOORDRAIN ADJACENT TOWATER HEATERFLOOR DRAINVALVES ARE NOT PERMITTED INTHE PIPING SYSTEM BETWEEN THEWATER HEATER AND THEEXPANSION TANK125 °DRAIN FROM PANTO FLOOR DRAINWITH AIR GAPAUTO AIR VENTWITH DRAIN TOdrain panFOR CONTINUATIONREFER TO FLOOR PLANSCALE:14P-5HOT WATER HEATER DETAIL N.T.S.SCALE:13P-5RESTROOM HOT WATER RETURN RISER DIAGRAM N.T.S.1"ASME rated THERMALEXPANSION TANKBALANCING VALVE1/2"HOT WATER CIRCULATINGPUMP-bell & gossett PL-30B1/12 HP, 1-60-120V1/2"FOR CONTINUATIONSEE dwg p-44" INTAKE (PVC)BRADFORD WHITEDOMESTIC HOT WATERSTORAGE HEATER100 GALLON CAPACITY150,000 BTU/HR INPUTSET OUTLET TEMPERATURE@ 125°F (1-60-120V)FOR CONTINUATIONSEE dwg p-4hwr tweiss tri-o-meterFOR CONTINUATIONSEE dwg p-4check valve(TYPICAL)shut-off valve (typ)STRAINER(TYPICAL)HWR1/2"EXTEND AND CONNECT GAS SUPPLYTO WATER HEATER-COORDINATECONNECTION SIZE AND LOCaTIONWITH WATER HEATER AT SITETEMPERATURE AND PRESSURERELIEF VALVE, SIZE ANDSETTING AT WATER HEATERMANUFACTURERSRECOMMENDATIONSCALE:11P-5CDL AT FLOOR CONNECTION N.T.S.SEE PLAN FOR SIZEFINISHED FLOOREXTEND AND INSTALL OVERP-TRAP - P-TRAP SHALLBE SAME SIZE AS PIPESCHEDULE 40 PVC PIPE WITHHUB END EXTENDED ABOVETHE FINISHED FLOOR1 1/4"CDL DISCHARGE FROMEVAPORATOR3"CDL AT FLOORSEAL W/SILICONCAP3/4"LAV.M.S.LAV.1/2"1/2"SOV1/2"1/2"3/4"3/4"for continuationrefer to dwgp-61/2"hw dnto lav1/2"hw dnto lav3/4"hw dn tomop sink1/2"hw up inwall toabove ceiling3/4"hw up inwall to aboveceiling1/2"hwr up inwall to aboveceilingHot water circulatingpump & valves to belocated below ceiling.vacuumrelief valve1/2" SUPPLY TOTRAP PRIMERCOLD WATER BRANCH LINETO FIXTURE ABV CEILINGUNION (TYP) WITH OR WITHOUT MANIFOLDDISTRIBUTION MANIFOLDINSTALL LEVELFLOOR DRAINFINISHED FLOORNOTES:1.DO NOT SUBJECT TRAPPRIMER TO ROUGH-IN WATERPRESSURE TESTING.2.INSTALL WITH ACCESS PANELFOR PERIODIC INSPECTION.SLOPE 1/4" / FTTOP CONNECTIONSERVICE BALL VALVETRAP PRIMER- SEE PLUMBING FIXTURESCHEDULE ON P-1SCALE:12P-5TRAP PRIMER CONNECTION DETAIL N.T.S.12" WITHMANIFOLD9-1/2" WITHOUTMANIFOLD1/2" COPPER TO EACHFLOOR DRAIN TRAPPRIMER CONNECTION.NO SCALERSM4772-R-P5P-5PLUMBING DETAILS 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 1.641WALK-IN COOLER EVAPORATOR unit - adt130bk3/4"+66"----3/4"+66"----3/4"+66"----3/4"+66"----COFFEE FIXING ISLAND UTILITY SINK+6"-----1/2"+60"----7.181COUNTER TOP SELF-RIMMING SINK1/2"+18"H.W./C.W.BTC+18"SAN.1 1/2"/2"----4.381HOSE REEL8.644-HEAD FCB MACHINE1/2"+48"FBTC+48"I.W.1/2"8.161BEVERAGE DISPENSER (FS60)1/2"+18"FBTC1/2"+34"I.W.7.471WALL MOUNTED WATER FILTRATION SYSTEM3/4"+60"C.W.VERIFY1/2"+8"I.W.8.531REMOTE ICE CUBE MACHINE1/2"+91"I.M.F.----8.314SOFT HEAT BREWER3/8"+18"FBTC1/2"+34"CO2FOOD SERVICE EQUIPMENT CONNECTION SCHEDULEITEMQTY.DESCRIPTIONTYPESIZECONN. HT.REMARKSPLUMBING1BACK FLOW VALVE1.722TAKE home COOLER EVAPORATOR - adt180bk7.062MOP SINKSAN.3"+18"----2UTILITY FAUCETH.W./C.W.1/2"+18"----H.W./C.W.SAN.I.W.11/2"1"1 1/2"/2"+6"+6"-----H.W./C.W.8.691MILKSHAKE BLENDING BARF.1/2"I.W.+6"+6"CHICAGO FAUCET11/4"1/2"+6"F.3.132vitamix BLENDERPROVIDED BY MANUFACTURERANDERSON BRASS ABF-ILLVACUUM BREAKER ON DEDICATED FAUCET1/2"+6"I.W.EXTEND TO FLOOR TROUGH----8.121ICE MACHINE+72I.M.F.----1/2"+72"I.W.C.W.W.C.W.W.C.W.W.C.W.W.WATTS 9D DUAL CHECK BY OWNER8.22C4UNDER COUNTER WATER BOOSTERS+18"F.----3/8"EXTEND TO WRREQUIREDEXTEND TO WR-13/4"EXTEND TO WRSODA DRIP TRAY, EXTEND TO WR-1CO2 MAINEXTEND TO WR-2EXTEND TO WR-1ANDERSON BRASS ABF-ILLANDERSON BRASS ABF-ILLANDERSON BRASS ABF-ILLANDERSON BRASS ABF-ILLANDERSON BRASS ABF-ILL8.372ICED BREWER1/4"+18"FBTCANDERSON BRASS ABF-ILL8.24SELF CONTAINED F.U.B. MACHINE - 2-HEADFBTC+48"I.W.1/2"EXTEND TO WR-133/8"+48"ANDERSON BRASS ABF-ILL8.751IMIX HOT BEVERAGE SYSTEM1/4"+18"FBTCANDERSON BRASS ABF-ILLNOTES:1.FOR ITEM 7.50 EACH INDIRECT WASTE LINE FROM THE THREE BOWL SINK SHALL TERMINATE INDIVIDUALLY OVER FLOOR SINK WITHAPPROVED AIR break. INDIRECT WASTE SHALL NOT BE MANIFOLDED.2.ALL INDIRECT WASTE LINES THAT ORIGINATE FROM EQUIPMENT SHALL BE TERMINATED OVER RECEPTOR WITH APPROVED AIRGAP. ALL INDIRECT WASTE FROM SODA DRIP TRAYS SHALL BE TERMINATED OVER RECEPTOR WITH APPROVED AIR BREAK.3.PROVIDE PRESSURE REGULATORS FOR ALL EQUIPMENT WHICH HAVE A FILTERED WATER CONNECTION, UNLESS OTHERWISE NOTED.refer to drawings p-7/p-8.4.FOR ITEM 8.53 THE INDIRECT WASTE SHALL TERMINATE OVER FLOOR TROUGH WITH APPROVED AIR GAP.5.EXTEND DRAIN/VENT FROM BACKFLOW PREVENTER TO NEAREST RECEPTOR WITH APPROVED AIR GAP.7.213WALL MOUNTED HAND SINK1 1/2"/2"+18"SAN.----3CHICAGO FAUCET1/2"+18"----H.W./C.W.8.921unic ESPRESSO MACHINE3/8"+18"FBTC1/2"+34"I.W.EXTEND TO WRANDERSON BRASS ABF-ILL1.962walk-in TAKE out COOLER EVAPORATOR - sm108be7.50H.W.3/4"+48"I.W.2"+12"I.W.1 1/2"+18"EXTEND TO F.S.I.W.1 1/2"+18"EXTEND TO F.S.I.W.1 1/2"+18"EXTEND TO F.S.EXTEND TO F.S.1FAUCET1/2"+18"H.W./C.W.BTC1PRE-RINSE SPRAY1/2"+18"H.W./C.W.BTC1DISHWASHER AND 3 BOWL SINK125°Fc.W.1/2"+18"---quick disconnect fittingsquick disconnect fittings1.861WALK-IN FREEZER EVAPORATOR unit - let120hkC.O.C.O.C.O.6"SAN4"GREASE SANC.O.FSFDFS4"SANITARYDROPSAN4"4"4"4"6"6"6"CONTINUED BY GENERALCONTRACTORSANSANGREASE SANC.O.FSWR-1WR-1SAN4"4"4"SAND.F.4"GREASESANITARY DROPfryerDISHWASHER3-bowlsinkCOFFEEBREWERSCOFFEEFIXING ISLANDFCBICE CREAMMACHINESBEVERAGEDISPENSERICEDBREWERS (2)SHAKEDISPENSERFUBS (3)C.O.C.O.3" V.T.R.3" V.T.R.3"3"3"2"2"3"3"4"2"C.O.C.O.C.O.3"cdl-UP3"3"3"3"cdlcdl3"C.O.C.O.4"3" BACKWATERVALVEforcontinuationrefer tosite planfollett icemachineWR4"TPC.O.2000 GALLONGREASE TRAPC.O.MS4"6"LAVLAVururwcF.D. WITHTRAPguardF.D. WITHTRAPguardSANITARYDROPC.O.wcwc6"6"6"6"4"4"4"4"4"4"4"4"C.O.2"W TO COFFEECOUNTER SINKAIR ADMITTANCEVALVEWR-1WR-1WR-1sanitary piping in thisarea shall be castiron. refer to p-1, note#21 for additionalinformation.WR-14"4"WR-2WR-2rte's3"co4"2"4"2"3" upco4"GREASE SANMS3"cdl-UPC.O.C.O.4"4"SANHANDSINK4"WR-1WR-2C.O.fdUTILITYROOMWATERHEATERC.O.futurewatersoftenerREMOTE ICE CUBEMACHINEHANDSINKTROUGH DRAINHANDSINK4"4"4"4"4"4"HANDSINK2"3"3"3" up2"2"3"3" V.T.R.C.O.4"3"2"4"2"4"3" V.T.R.3" V.T.R.4"4"HOTWATERTANKH.B.1/2"ICE MAKER3/4"M.S.SHAKEDISPENSERBEVERAGEDISPENSERICEDBREWERS(2)CWHWFF1 1/2"4-headFCBCIRCPUMP1"3/4"BALANCINGVALVE (TYP)1"3/4"WAREWASHERTRIPLE SINK1/2"1"HOSEREELWORKSINKCASEWORKSINK3/4"D.F.FCOFFEEF3/4"FCAPPUCINOMACHINEsunic ESPRESSOred rinser1"2"1/2"3/4"2"H.B.3/4"3/4"W.C.LAV.M.S.2"1 1/2"w.c.W.C.LAV.1/2"1/2"SOVSOVSOV1 1/2"1 1/2"U.R.u.r.1"HS-1EVERPURESYSTEMBLW SLABHS-11/2"1"1/2"1/2"3/4"BLW SLAB1 1/2"1 1/2"3/4"2"3/4"1/2"WATER FILTERheader2"STORESERVICE2"UTW3/4"UTWfutureWATERSOFTENERBADCUTWUTWUTWUTW3/4"3/4"3/4"imfimf 1/2"1/2"fubs (3)icemachine1/2"UTW3/4"3/4" HEADERFOR SOFT HEATBREWERS3/4" IMF-UP toice machine3/4"ffffffimfffffimf3/4"1 1/2"1/2"1/2"1/2" wandwithmixingvalveicecreamc w BLW SLAB3/4"1 1/2"1/2"h w 2"1/2"3/4"utwH.B.blw slab3/4"utw dn3/4"utw up to hb1 1/2"3/4"(4) 5" conduits blwslab for syrup &co2 by e.c.BAG INBOX2" CONDUITREFER TOARCHITECTURALDRAWINGS FORCO2 TANKLOCATIONBLW SLABSODASODASODAco2HS-1imf1"1" to 3/4" decreaser2 1/2" (240,000 BTUH)GGGGFOR FUTUREGAS FRYER2 1/2" (370,000 BTUH)1 1/2" (130,000 BTUH)3/4" (45,000 BTUH)GG80,000 btuh1 1/2" (365,000 BTUH)2 1/2" (885,000 BTUH)RG 2 1/2"ON ROOFON ROOFON ROOF1 1/2" (240,000 BTUH)ON ROOF1"G-DN & CAPPED ABOVE CEILING2 1/2"DN THRUROOF1" (150,000 BTUH)4"WATERHEATERINTAKETHRU ROOF4"4"WATERHEATER FLUETHRU ROOF4"DOWN THRUROOFWATERHEATER2 1/2" (735,000 BTUH)1" (130,000 BTUH)GAS meter set at buildingface REGULATORSET @ 6 OUNCESTOTAL CONNECTED LOAD:885,000 BTUHLENGTH OF PIPE=130 FEETFROM MAIN REGULATOR LINESSIZED FROM NFPA 54mNOTE: PROVIDE GAS LINE SIZES ASINDICATED ON DRAWINGS ANDTRANSITION TO EQUIPMENT CONNECTIONSIZE AFTER ISOLATION VALVE AND WITHIN12" OF EQUIPMENT.DN SIDEOF BLDGAC-3240,000BTUHAC-2130,000BTUHEF-4M45,000BTUHAC-1240,000BTUHON ROOFON ROOFFD.FLOOR DRAINFSFLOOR SINKHOT WATER PIPINGCOLD WATER PIPINGVENT PIPINGDROP IN PIPINGFCO.RISE IN PIPINGFLOOR CLEANOUTWCO.WALL CLEANOUTPLUMBING LEGENDDETAILDESCRIPTIONFILTERED WATERICE MAKER FEEDER WATERFHOT WATER RETURN PIPINGWRWASTE RECEPTORGAS PIPINGGVIMFTRAP PRIMER PIPINGTPSANITARY WASTE PIPINGSANGREASE SANITARY WASTE PIPINGGREASE SANCONDENSATE DRAIN LINECDLHWRHWCWSODA DISPENSER SYRUP CONDUITSODACO2 TUBINGCO2BALANCING VALVESHUT OFF VALVE/BALL VALVECHECK VALVEHB.HOSE BIBBGAS COCK VALVETPTRAP PRIMER VALVESOVSHUT-OFF VALVEUNTREATED WATERUTWNO SCALERSM4772-R-P6P-6PLUMBING RISER DIAGRAMS SANITARY PIPING RISER DIAGRAMSCALE: NONEWATER PIPING RISER DIAGRAMSCALE: NONE2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEER DAVID J. ANDER SON SEAL04300512-21-17GAS PIPING RISER DIAGRAMSCALE: NONE SCALE:2P-7CO2 INSTALLATION DETAIL N.T.S.PLUMBING FIXTURE PROCUREMENT AND INSTALLATION SCHEDULEPLUMBING EQUIPMENTFURNISHED BYINSTALLED BYwater BOOSTER and/or carbonatorOWNERrefrigeration contractorback flow preventerPLUMBING CONTRACTORPLUMBING CONTRACTORregulatorpressure GAGE3/8" female connectionPLUMBING CONTRACTORrefrigeration contractorrefrigeration contractorownerownerPLUMBING CONTRACTORball valvesPLUMBING CONTRACTORPLUMBING CONTRACTORFS60SODA FOUNTAINNUCO2MIZER 450RATED @300 PSITANK REGBUILDINGPRESSUREGAGE @150 PSI1/2" GAS USE1/2"TANK GAGE@ 150 PSISPARECARBONDIOXIDETANKSELECTORVALVE1/2"FLOORSODA BOXRACK #1SODA BOXRACK #2SPAREHIGH PHASECAPPEDREGULATORBIBPUMPSRACKs 1, 2SET @ 72PSI (ADJ)1/2"REGULATORSET AT 115 PSI(115 PSI)RRRFS60REGULATOR SETAT 75 PSI (ADJ)1/4" cONNECTIONAT EQUIPMENT4 HEAD FCBR4 HEAD FCBREGULATORSET AT 72PSI (ADJ)1/4" CONNECTIONAT EQUIPMENT1/2"(115 psi)RRREGULATORSET AT 115 PSINOTES:1.CONTRACTOR SHALL NOT SPLICE ANY CO2 LINESDOWNSTREAM OF THE SECONDARY REGULATOR FORANY PIECE OF EQUIPMENT.2.ALL EQUIPMENT MUST RECEIVE DEDICATED 1/2" (115 PSI)LINE FROM HEADER LOCATED IN WORK ROOM.3.ALL CO2 PRESSURES LISTED ON THIS DETAIL SHALL BECONFIRMED WITH MANUFACTURER RECOMMENDATIONS.4.REGULATORS USED FOR CO2 SHALL BE APPROVEDFOR CO2 APPLICATIONS.SALES AREAWORK ROOM1/2" (115 psi)3P-7SCALE: N.T.S.FOUNTAIN/Fcb/fub LINE - STORE FRONT UNDERCOUNTERWATER MANIFOLD DETAILSCALE:1P-7ROOM WATER FILTRATION DETAIL N.T.S.513/8" feMALE ADAPTOR FOR EXTENSIONBY REFRIGERATION CONTRACTOR WITHPEX TUBING TO 8.69.243/8" feMALE ADAPTOR FOR EXTENSIONBY REFRIGERATION CONTRACTOR WITHPEX TUBING TO 8.22C (WATERBOOSTER). 1/2" MALE ADAPTOR ANDPEX TUBING FROM 8.22C (WATERBOOSTER) FOR EXTENSION TO ITEM 8.64.3all connections and piping in thisarea are by refrigerationcontractor.3/8" feMALE ADAPTOR FOR EXTENSIONBY REFRIGERATION CONTRACTOR WITHPEX TUBING TO 8.22C (WATERBOOSTER). 1/2" MALE ADAPTOR ANDPEX TUBING FROM 8.22C (WATERBOOSTER) FOR EXTENSION TO ITEM 8.16.3/8" feMALE ADAPTOR FOR EXTENSIONBY REFRIGERATION CONTRACTOR WITHPEX TUBING TO 8.37.63/8" FEMALE ADAPTOR FOR EXTENSIONBY REFRIGERATION CONTRACTOR WITHPEX TUBING TO 8.24. AT 8.24, INSTALL1/4" TO (2) 3/8" ADAPTOR FORCONNECTION TO EQUIPMENT.NOTES:1.PROVIDE WATER REGULATOR AND SET TOMFG RECOMMENDATIONS ON EACH PIECE OFEQUIPMENT.2.PROVIDE IN-LINE VALVE ABOVE COUNTERPRIOR TO CONNECTIONS TO EACH PIECE OFEQUIPMENT.8.64RWATERREGULATOR(TYP)1/2"3/8" valvedbypass line (TYP)1-1/2"8.22C WATERBOOSTER1/2"38" femaleconnection(typ)backflowpreventer a.s.s.e.1022 compliant (typ)1-1/2"1/2"copper abvslab (typ)pex blw slab (typ)1-1/2"from filterfloor1/4 turn ballvalve (typ)1-1/2"EXTEND EACH DRAIN VENTline INDIVIDUALLY toNEAREST receptor WITHAPPROVED AIR GAP (TYP)1-1/2"provide cap (SPARE)32provide cap(SPARE)pressuregage1/2"8.691/2"8.3751WATERREGULATOR (TYP)1-1/2"1/2"38" femaleconnection (typ)1/4 turn ballvalve (typ)R1/2"R1/2"8.24R1/2"EXTEND EACH DRAINVENT line INDIVIDUALLYto NEAREST receptorWITH APPROVED AIRGAP (TYP)3/8" backflowpreventer a.s.s.e.1022 compliant (typ)8.22C WATERBOOSTER3/4"3/8" by-pass lineTUBING EXTENSIONTO EQUIPMENT BYOTHERS (TYP)78.248.243666provide cap (SPARE)38.161/2"R48.161/2"R48.22C WATERBOOSTER1-1/2"3373/4" TO 3/8" FEMALE CONNECTIONAT INLET. 1/4" FEMALE TO 3/4"connection ON OUTLET. TRANSITION 3/4"TO 1-1/2" PRIOR TO VALVE.EVERPURE HIGH FLOW QUAD EV9437-32 W/ENDURANCE QUAD CARTRIDGE KIT: EV9628-72ENDURANCE HIGH FLOW QUAD SYSTEMMAX FLOW OF 15 GPMTOBUILDINGDRAIN2SR-BWSCALEINHIBITORCARTRIDGECEILINGFLOOR3/4"1 1/2"3/4"3/4"1 1/2"3/4"FOLLETT 1650 ICE MACHINE 1 1/2"ABv CLGcoffee fixing islandFOUNTAIN/FCB/fub LINEKITCHEN 1/2 WALL 3/4"3/4"1-1/2"CONNECT TODOMESTIC CWSUPPLY1/2"ABV CLG3/4"WITHIN WALL(TYP)PGREFER TO P-4 FORCONTINUATION(TYPICAL)REFER TO P-2 FORCONTINUATION(TYPICAL)COPPER PIPINGPEX TUBING1/2"1/2"espresso machinedrinking fountainremote ice machine- work rm 1/4 TURN ballVALVES (typ)NOTEs:1.PROVIDE PERMANENT TAG ON PIPING AS SHOWN.2.PROVIDE 1/4 TURN BALL VALVES.3.ALL EXPOSED COPPER PIPING SHALL HAVE INSULATION AS SPECIFIED ON P-1.4.all valves shall be located below ceiling and exposed.1-1/2" BYPASS LINENORMALLYCLOSEDsmoothiesfrozen coffeesmilkshakesfloorWR-1tru-AIRGAPfittingunionfs1" TYPE K COPPER FROMDRAIN CONNECTION OFTROUGH TO ABOVE floorsink WITH air break (typthis line UNLESS NOTEDOTHERWISE)8.22c8.22cWR-1WR-11-1/2" pex blw slabfrom filter (typ)5" CONDUITS UP FROMBLW. FLR. & IN CABINETFOR SYRUP AND CO2F.C.B.8.64fountain8.16iced brewers8.378.378.24fub(s)8.248.24milkshake8.698.078.05ice cream machines1/2"8.375REFER TO P-2 FOR CONDUIT SIZEAND LOCATIONS1/2"1/2"(115 PSI)1/2"EXTERIORINTERIORP-7SHEETZ BROTHERS COFFEE FIXING ISLAND SCALE:undercounter WATER MANIFOLD DETAIL N.T.S.41ALL CONNECTIONS AND PIPING IN THIS AREAARE BY REFRIGERATION CONTRACTOR.2NOTES:1.PROVIDE WATER REGULATOR AND SET TO MFGRECOMMENDATIONS ON EACH PIECE OF EQUIPMENT.2.PROVIDE IN-LINE VALVE ABOVE COUNTER PRIOR TOCONNECTIONS TO EACH PIECE OF EQUIPMENT.3/8" feMALE ADAPTOR FOR EXTENSIONBY REFRIGERATION CONTRACTOR WITHPEX TUBING TO 8.75.8.22ctru-AIRGAPfittingRRcopper abvslab (typ)pex blw slab (typ)3/4"from filter3/4"pressuregage1/2"1R1/2"3/4"floorWATERREGULATOR (TYP)38" femaleconnection (typ)1/4 turn ballvalve (typ)3/8" backflowpreventer a.s.s.e.1022 compliant (typ)provide cap (SPARE)EXTEND EACH DRAIN VENTline INDIVIDUALLY toNEAREST receptor WITHAPPROVED AIR GAP (TYP)8.752P-7SHEETZ BROTHERS COFFEE AREA - KITCHENSCALE:UNDERCOUNTER WATER MANIFOLD DETAIL N.T.S.513/8" MALE ADAPTOR FOR EXTENSION BYREFRIGERATION CONTRACTOR WITH PEXTUBING TO 8.31.ALL CONNECTIONS AND PIPING IN THIS AREAARE BY REFRIGERATION CONTRACTOR.2NOTES:1.PROVIDE WATER REGULATOR AND SET TO MFGRECOMMENDATIONS ON EACH PIECE OF EQUIPMENT.2.PROVIDE IN-LINE VALVE ABOVE COUNTER PRIOR TOCONNECTIONS TO EACH PIECE OF EQUIPMENT.copper abvslab (typ)pex blw slab (typ)3/4"from filter3/4"3/4"floor1/2"11/2"11/2"11/2"11/2"38" femaleconnection (typ)1/4 turn ballvalve (typ)provide cap (SPARE)8.318.318.318.313/8" backflowpreventer a.s.s.e.1022 compliant (typ)2EXTEND EACH DRAIN VENTline INDIVIDUALLY toNEAREST receptor WITHAPPROVED AIR GAP (TYP)pressuregage3/4"floor88provide hose connection.NO SCALERSM/DJA4772-R-P7P-7PLUMBING WATER MANIFOLD AND CO2 DETAILS2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 (8.12) ICE MACHINESCALE: NTS(8.22C) WATER BOOSTER (SLIM)SCALE: NTS(8.31) COFFEE BREWERSCALE: NTS(8.53) REMOTE ICE CUBE SCALE: NTS(8.64) 4 HEAD FCB MACHINESCALE: NTS(8.69) MILKSHAKE BLENDING BARSCALE: NTSMACHINEPRESSURE PORTACCUMULATORMOTORFOR CONTINUATIONREFER TO P-71/4" PEX TUBINGUNION1/4 TURN BALLVALVE1/4" PEXTUBINGNOT USEDNOT USEDNOT USEDNOT USED3/8" WATERCONNECTION1/4 TURN BALL VALVE1/2" PEX TUBINGRWATER REGULATOR, SETTO 50 PSI (ADJ). REFERTO P-7 FOR LOCATIONFOR CONTINUATION REFERTO DRAWING P-41/4" MALE FITTING1/4 TURN BALL VALVE1/4" PEX TUBINGRWATER REGULATOR, SETTO 50 PSI (ADJ). REFERTO P-7 FOR LOCATIONFOR CONTINUATION REFERTO DRAWING P-7RWATER REGULATOR, SETAT 50 PSI (ADJ). REFERTO P-7 FOR LOCATION3/8" BARB FITTING1/2" I.D. CONNECTIONFOR CONTINUATION REFERTO DRAWING P-71/4 TURN BALL VALVE1/4" MALE FITTINGSYRUP LINESCO2 CONNECTIONDRAIN CONNECTION WITHAPPROVED AIR GAPRWATER REGULATOR, SETAT 50 PSI (ADJ). REFERTO P-7 FOR LOCATION1/4 TURN BALL VALVEDRAIN TO APPROVED AIR GAP1/2" DRAIN LINE1/4 TURN BALL VALVE3/8" F.P.T. IMF INLET1/4" PEX TUBINGRWATER REGULATOR, SETTO 50 PSI (ADJ)FOR CONTINUATION REFERTO DRAWING P-4NOT USEDNOT USEDNOT USED1" DRAIN LINE FROMDRAIN PAN1" CONDENSATEDRAIN LINENOT USEDNOT USED(8.24) FUBSCALE: NTSFOR CONTINUATIONREFER TO DRAWINGP-7RR1/4 TURN BALL VALVEWATER REGULATOR, SETTO 50 PSI (ADJ)1/4" PEX TUBING1/4" BARB CONNECTIONSYRUP LINES(8.37) iced BREWERSCALE: NTS1/4" FLARE INLET CONNECTION1/4 TURN BALL VALVE1/4" PEX TUBINGFOR CONTINUATIONREFER TO DRAWING P-7NOT USED(8.16) BEVERAGE DISPENSER (FS60)SCALE: NTS3/8" BARB FITTINGFOR CONTINUATIONREFER TO DRAWINGP-73/8" PEX TUBINGFOR CO2CO23/8" BARB WATER INLETFOR CARBONATOR3/8" BARBWATER INLETRRFOR CONTINUATIONREFER TO DRAWINGP-7WATER REGULATOR, SETTO 75 PSI (ADJ)CARBONATOR WATER REGULATOR,SET TO 50 PSI (ADJ)3/8" PEX TUBING(16) 3/8" syrup TUBES with 1/4turn ball valve (typical)(12) 3/8" FLAVORDISPENSER TUBESwith 1/4 turn ballvalve (typical)(2) 3/8" IMF LINES (IF REQUIRED)3/8" BARB INLET(TYP FOR 16).3/8" BARB INLET(TYP FOR 12)DRAIN LINE(8.75) imix hot beverageSCALE: NTS1/4" FLARE INLET CONNECTION1/4 TURN BALL VALVE1/4" PEX TUBINGFOR CONTINUATION REFERTO DRAWING P-7(8.92) unic ESPRESSO MACHINE1 1/4" DRAIN LINETYPE K COPPER.REFER TO DRAWINGP-4.1/2 TURN BALL VALVE3/8" COMPRESSION FITTING1/2" PEX TUBINGRWATER REGULATOR, SETTO 50 PSI (ADJ)FOR CONTINUATION REFERTO DRAWING P-4SCALE: NTSRWATER REGULATOR, SETTO 50 PSI (ADJ)(11.50) WATER FOUNTAINSCALE: NTS3/8" CONNECTION1/4 TURN BALL VALVEFOR CONTINUATION REFERTO DRAWING P-43/8" PEX TUBING1 1/4" I.P.S. DRAINCONNECTION REFERTO P-4FLOORFLOORWATTS LFUSG-B-M2 MIXINGVALVE - SET MAX AT 100°FWANDREFER TO P-2 FORCONTINUATIONBLW SLAB12x12 ACCESS PANEL INSTALLEDWITHIN WALL FACING ICE CREAMHWCWICE CREAM MACHINE (TYP)UP IN WALL TOMIXING VALVE3/4"ice cream riser diagramSCALE: NTSAS NOTEDRSM/DJA4772-R-P8P-8FOOD SERVICE EQUIPMENT CONNECTION DETAILS2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 LIGHTING PLAN'sheetz' SIGN MOUNT @11'-6" AFF (TYP)A-35 SIGN CIRCUITSCALE: 1/4" = 1'-0"GENERAL ELECTRICAL NOTES:1.SEE SHEET E-4 FOR ELECTRICAL EQUIPMENT SCHEDULE.2.ALL 'X' FIXTURES TO HAVE A 2"x4" BOX INSTALLED HORIZONTALLY IN BRICK.3.SALES AREA 1: THE 'BB1' LIGHT FIXTURES LOCATED ALONG THE AREA PERIMETER SHALL BE CONTROLLEDTHROUGH THE plc. REFER TO 'STORE PLC CONTROL SYSTEM' SHOP DRAWINGS BY ENERTECH ASSOCIATES FORWIRING DIAGRAMS AND ADDITIONAL DETAILS AND INFORMATION.4.BUILDING LIGHTING CONTROLLED BY PLC PANEL VIA EXTERIOR PHOTOCELL. REFER TO 'STORE PLC CONTROLSYSTEM' SHOP DRAWINGS BY ENERTECH ASSOCIATES FOR WIRING DIAGRAMS AND ADDITIONAL DETAILS ANDINFORMATION.5.ALL SWITCH OCCUPANCY SENSORS INSTALLED IN THE FOLLOWING SPACES SHALL BE MANUAL 'ON', AUTOMATIC'OFF': OFFICE, EMPLOYEE UTILITY SPACE, JANITOR'S CLOSET.6.ALL CEILING OCCUPANCY SENSORS INSTALLED IN BATHROOMS SHALL BE AUTOMATIC 'ON' 100% OUTPUT,AUTOMATIC 'OFF'.7.SMOKE DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIRFLOW OR CLOSER THAN 36" FROM AN AIR SUPPLYOR A RETURN AIR OPENING, ACCORDING TO NFPA A.17.7.4.1KEY NOTES:1" CONDUIT IN CANOPY GG2X1A-15A-10SPLA-13MBATTDD MA-19FSBATTZZXMount @12'-0" AFFA-15A-10A-36A-13EE2'sheetz' SIGN MOUNT @11'-6" AFF (TYP)A-35 SIGN CIRCUITPPPPA-33BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1FFFFFFF1" CONDUIT IN CANOPYX1A-15GG2MOUNT @ 24"ABV DOORSALESAREA 2A-13SOSA-19FSA-19A-19OSOSFSFSOSA-12A-11A1A-19UTILITYROOMFSSS 1 1/2" GOOSENECKCONDUIT FOR LOTTERYA-19WORKROOMFSemployeeutility spaceSOS A-10A-3A-1TTTTGG1GG1A-1BATTDDMA-29A-1FSA-8A-19FSA-21FSA-21FSMH-22BATTZZGG1GG1A-1BATTDDMA-1SALES AREA 1TAKE HOMECOOLERMENWOMENJANKITCHENCOFFEEWALK-INCOOLERSPL S P L H-25PHPHOTOCELL MOUNTEDON ROOF POINTINGNORTH AS PER OWNERWALK-INFREEZERGG2BATTZZH-25EE2BATT DD BATTDD A-12A-11A-16A-14A-36MOUNT BOTTOM OF LIGHT FIXTURE@ 6'-8" AFF, CENTER OF JUNCTIONBOX @ 7'-5" (TYP)GG1GG1A-3BATTDDA-8B A T T D D OSH-22H-25A-10A-10EE1BATTZZA-1A-1WALK-INTAKE-OUTCOOLERCONTROLLEDFROM SWITCHIN OFFICEH-22XMount @12'-0" AFFA-15X MOUNT @12'-0" AFFA-15MOUNT @ 24"ABV DOORSPL 33 S WALK-IN COOLERSWITCH IN OFFICEA1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1EE1A1A1A1A1A1A1A1A1A1A1A1A1A1A1A1MTD ABVCOOLERA-3SDTA3 A3GG2MTD ABVCOOLERFTBB1BB1BB1BB1BB1BB1BB1BB1OO 1111OO OO OO OO OO OOOOOOOOOOOO OO PPA-21FSMTD on wall12" blw CLGMTD on wall12" blw CLGVESTIBULECHECKSTANDOOX A-15221MOUNT 'GG1' TYPE led LIGHT FIXTURE ON WALL 6" BELOW CANOPY.2MOUNT 'GG2' TYPE led LIGHT FIXTURE ON WALL at 96" aff.TupMOUNT @12'-0" AFFA-21A1SSSSSS16'-0"SA1A1A1A1FSA1A1A1A1FSA1OFFICESOS A-10A1A1SS BB1BB1BATT A-10DD BATTA-10DDQQNNNGGGGGGGGNBB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1FSBB1BB1BB1BB1BB1BB1BB1BB1BB1 BB1BB1BB1BB1BB1BB1UUUUUUUUUUUUACCESSDOORGG2'sBC' SIGN MOUNT @11'-6" AFF (TYP)A-35 SIGN CIRCUITSYMBOLMANUFACTURERCATALOG NUMBERLAMPSREMARKSQUANTITY2SRBK6-12WLED-WW-120-U/D-E(up)-O(dn)-WM-BLLIGHTING FIXTURE SCHEDULEA1FlagFGMTXX1246588147CREECREEB-K LIGHTINGlithoniaSOLERACREECREEBLD-ARE-15-SA-051-LED-B-UL-B2VS-LED-E102-BZP-9lqm-s-w-r-120/277-el-n-m6SEC-EDG-3M-WM-04-e-UL-BZ-525mASEC-EDG-3M-WM-02-E-UL-BZ-525mALED (40 WATT SOURCE)4000 LUMENS, 4000kLED (71 WATT SOURCE)LED-MR16-12-3-3-DL (3 WATT)LED (1 WATT SOURCE)LED (12 WATT SOURCE)(SOFT WHITE, 3500K)LED (70 WATT SOURCE)(THREE LIGHT BARS)LED (37 WATT SOURCE)(TWO LIGHT BARS)1' x 4' LED FLAT PANELFLOOD LIGHTSBRONZE FINISH CANOPY LIGHTSPENDANT LIGHT IN SEATING AREA(FEATURE LIGHT)LED EXIT SIGN W/ BATTERY BACK-UPEXTERIOR DECORATIVE WALL SCONCEEXTERIOR SECURITY WALL PACKEXTERIOR SECURITY WALL PACK 1' x 4' LED LINEAR INDUSTRIALA32CREECS14-40HE-40K-10VLED (37 WATT SOURCE)4000 LUMENSFP14-40L-40K-10V-10YR001-802-ELYled (20 WATT source)conantmetal lightN4KICHLER100 WATT SOCKETUSE SATCO LED LAMP42525oz-(old Bronze)PENDANT LIGHT IN SEATING AREA OVER BOOTHS(FEATURE LIGHT)SYMBOLMANUFACTURERCATALOG NUMBERLAMPSREMARKSQUANTITYLIGHTING FIXTURE SCHEDULE (continued)EE12EATON lightingSRM13WH(1) LED, 1.25 Watts(4.8V THRU 12V INPUT VOLTAGE)EE22SRM25DWHWALL MOUNTED single EMERGENCYINTERIOR REMOTE HEADWALL MOUNTED double EMERGENCYINTERIOR REMOTE HEADS(2) LEDS, 2.50 Watts(4.8V THRU 12V INPUT VOLTAGE)RECESS MOUNTED IN CEILING EMERGENCY LIGHTW/ BATTERY BACK-UPRM6-36-T0609-2-W(2) 6 Volt, 9 Wattsbarron lightingDDEATON lighting11DIE CAST GIMBAL RING TRACK HEADJUNOT1020-E26-50W-WHS7LED (8 WATT PAR20 SOURCE)LED8PAR20DIM830FL40GLIWBA-LED10-WTecosense ltgLED (16 max. WATT SOURCE)FIXTURE NUMBER; SCIS-48-40-120-CLWIRING OPTICS; (INT2P-A-LDR-120-10) (INT2P-A-JMP-120-12)GG25SRM13BK(1) 6 Volt, 1.25 WattsWALL MOUNTED single EMERGENCYOUTDOOR REMOTE HEADSRM25dBK(2) 6 Volt, 2.5 WattsWALL MOUNTED double EMERGENCYOUTDOOR REMOTE HEADSCOOLERS & FREEZERBOLLARD LIGHTSLED TASK LIGHT - TRAINING DESKPWY-EDG-5M-P4-02-E-UL-BZ-525-40KLED (15.61 WATT SOURCE)LED (34 WATT SOURCE)WAC LIGHTINGCREEJUNOT-4FT-WHGG1OOPPQQZZTRACKEATON lightingEATON lighting6143144- - - -RECESS MOUNTED IN CEILING EMERGENCYBATTERY BACK-UP W/ NO HEADSRM6-36-W- - -barron lightingUU64' WHITE TRACKBB192CREELED (11 WATT SOURCE)RECESSED LED DOWNLIGHT INSIDE STORERC6-12W-GU24-Lr6-10L-40K-120V-A-DRA-1BATTDDA-1BATTDDA-29A-2A-3Seating AREABB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1BB1A-29BB1BB1BB1BB1BB1BB1FSA-21A-21A-21A-21ZL1N L48 5000LM FST MVOLT 40K 90CRI MB(MATTE BLACK COLOR FIXTURE HOUSING)WALK-IN TAKE-OUT COOLER (housing painted black)LED (44 MAX. WATT SOURCE)LITHONIAA-21FSA-19FS1/4" = 1'-0"WSP4772-R-E1E-1 LIGHTING PLAN 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 UNDER GROUND ELECTRIC CONDUIT PLANSCALE: 1/4" = 1'-0"TO SERVERTO PHONE AREA5516'-6"25'-712"4"39°4"4"4"4"4"4"TANK MONITOR SEEDETAIL SHEET E-98'-7"6" 4"28'-512"2"2"3"4" 1'-11"2"21'-4"311121" CONDUITS TO BE USED FORHOT BOXES AT INCOMINGDOMESTIC WATER SERVICE ANDIRRIGATION WATER SERVICE425'-01 2"3"46'-01 2"10"1'-212"KEY NOTES:12ELECTRICAL CONDUITS (H.V.)COMMUNICATION/DATA CONDUITS (L.V.)LEGEND3(1) 1" PVC - ELEC (HV)411910(1) 1 14" PVC TO - COMM/DATA (LV)567(3) 1" PVC - ELEC (HV)81 1/4" DIA. (LV) CONDUIT FROM ABOVE OFFICE WALL DOWNUNDER FLOOR SLAB TO PICK-UP AREA AS INDICATED.(2) 2" RMC TO (LV) - INTRINSICALLY SAFE TROUGH122" RMC TO (HV) - INTRINSICALLY SAFE TROUGHTWO (2) HUBBELL PFB1 FLOOR BOX, EACH W/ PFBA1AADAPTER, HUBBELL CR20 RECEPTACLE ( F-16 ), S3925DUPLEX COVER AND S5016 ADAPTER RING FOR POWER TONOVELTY FREEZER. TWO (2) HUBBELL PFB1 FLOOR BOX EACHW/ PFBA1A ADAPTER, S3925 DUPLEX COVER AND S5016ADAPTER RING FOR FUTURE DATA AT THIS LOCATION.13(2) 114" PVC TO - COMM/DATA (LV)(5) 1" PVC - ELEC (HV)1415COORDINATE FINAL LOCATION OF CONDUITS BEING STUBBED UPAT THIS LOCATION WITH THE PLUMBING CONTRACTOR IN THEFIELD.HIGH VOLTAGE AND LOW VOLTAGE CONDUITS FOR GAS EQUIPMENTAND CANOPY LIGHTING SHALL BE RMC FOR A MINIMUM OF 10 FEETON EITHER END, INSTALLED UNDERGROUND, AND COVERED WITH NOTLESS THAN 24" OF COVER FROM TOP OF CONDUIT TO FINISHEDGRADE. SIZE AND QUANTITY OF CONDUITS ARE TO BE VERIFIED INTHE FIELD. REFER TO PETROLEUM DRAWINGS FOR ADDITIONALINFORMATION AND DETAILS.(2) 1" PVC - ELEC (HV)conduit for syrup and co25" CONDUIT FOR SYRUP AND CO2 TUBING. PROVIDE temporaryREMOVABLE CAP AT EACH END.GENERAL ELECTRICAL NOTES:1.ALL ELECTRICAL (H.V.) AND LOW VOLTAGE (L.V.) CONDUITS SHOWN BELOWWINDOWS OR AROUND DOORS SHALL BE RUN UNDERSLAB.2.ALL DIMENSIONS SHOWN ON THIS PLAN ARE FROM THE INSIDE FACE OF THEFOUNDATION BLOCK. ALL DIMENSIONS SHALL BE FIELD VERIFIED ANDCOORDINATED WITH ARCHITECTURAL FLOOR PLANS.3.ALL EMPTY CONDUITS SHALL BE FURNISHED WITH NYLON PULL CORDS FOREASE OF INSTALLING FUTURE BRANCH CIRCUIT WIRING AND DATA CABLES.4 RUNS (4-350 MCM COPPER) IN 4" PVCCONDUITS UNDERGROUND) OR 4" R.G.S.CONDUITS WHERE EXPOSED.) ALLCONDUCTORS TO BE TYPE (THHN/THWN -2)90 DEGREE C INSULATION TO MDPELECTRIC COMPANYCT'S AND METER400A-3P-NF, 240V, NEMA 3r, HEAVY-DUTYDISCONNECT SWITCH MTD ON EXTERIORWALL NEXT TO CT CABINET FOR HOOK UPTO PORTABLE GENERATOR BY OTHERS.6212"212"212"23'-6"1531'-512"31'-0"2"2"2"2"13'-5" 13'-10"31310'-21 2" 12'-4"41'-0"43'-712"50°(4) 1" PVC - ELEC (HV)16165217'-10"6"6"6"22'-8 12"4517"529'-712"427'-712"4"4"4"33'-1112"4"4"25'-6"3"17212"212"212"7'-112"7'-112"13'-3"1717441426'-0"7'-9"4106'-0"22'-3 1 2" 20'-3"36'-7"10CONDUIT TO BE USEDFOR LIGHTED BOLLARDS420'-1"812"7"10"4"18'-4"4"38'-212"4"4"4"4771639497floor box at this location shall be a hubbell CFBS1R4PFBfloor box with a CFBS1RR4CUP MOUNTING CUP, S1R4SPSTYLEMOUNTING PLATE, CFBS1R4CVRBRS BRUSHED BRASS cover, ANDGF20 GROUND FAULT INTERRUPTER TYPE RECEPTACLE.8820'-8"21'-8"8'-0" 7'-3 1 2" 7'-2"11'-1112"12'-412"13'-912"14'-912"15'-912"12'-1112"3" 41 2"ONE(1) HUBBELL PFB1 FLOOR BOX W/ PFBA1A ADAPTER,HUBBELL CR20 RECEPT. ( F-14 ), S3925 DUPLEX COVERAND S5016 ADAPTER RING FOR POWER TO BAKERY CASE.ONE(1) HUBBELL PFB1 FLOOR BOX W/ PFBA1A ADAPTER,S3925 DUPLEX COVER AND S5016 ADAPTER RING FORFUTURE DATA AT THIS LOCATION.4517(1) 1-1/4" PVC - COMM/DATA/INTERCOM (LV)AS NOTEDWSP4772-R-E2E-2 UNDER GROUND ELECTRIC CONDUIT PLAN 2017-0594x0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNET COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 ELECTRICAL EQUIPMENT PLANSCALE: 1/4" = 1'-0"40"40"40"40"48"40"E-30NOTE:ALL OFFICE RECPTSTO BE DOUBLEDUPLEXSALES AREA 1KITCHENCOFFEESH-7,9COOLER LTSH-25COOLER HTRSH-13WALK-IN COOLERWALK-IN FREEZERH-25FREEZER LTS& HTRSSH-21,23B-12E-3COMPUTERE-28G1-12OFFICEE- 1 D - 1 2 E- 1 D - 1 3 , 1 5 C- 2 6 C- 3 0 C- 3 2 D - 4 C - 9 D- 3 9 A-20A-30A-25,27A-32,34SALES AREA 2MENSWOMENSICEMERCH.11.7511.75H-32H-30(10) TAKE HOMECOOLER DOOR LTS(10) TAKE HOMECOOLER DOORHTRSH-26H-24D-24MTD ABV STONE SILLBOTTOM. RECPT MTD@ 3'-3" AFFJAND - 1 6 40"E-7C - 1 , 3 , 5 C - 2 , 4 , 6 C- 1 6 C- 2 1 , 2 3 E- 1D-24GFIWPGFIWPWPWPGFIA-231" CONDUIT WITH GOOSENECKTURNDOWN FOR SATELLITECOMMUNICATION (VERIFYLOCATION IN FIELD)CCCCCCCFOR GAS SIGNCONTROL CONNECTIONCCCCCICEMERCH.GFID-7 D-5 D-20 D-18 F-17 F-9MTD UNDER CABINETMTD UNDERCABINETB - 3 0 GFIMTD @ 84" AFFE-13SGFIA-17A-17MTD ABV STONE SILLBOTTOM OF RECPTMTD @ 3'-3" AFFMTD ABV STONE SILLBOTTOM OF RECPTMTD @ 3'-3" AFFB-21B-19TO DOMESTIC AND IRRIGATIONWATER SERVICE HOT BOXES IN1" CONDUITS.40"E-11MOUNT RECEPT 12" FROMCORNER & 7'-7" AFF TOTHE BOTTOM OF RECEPTG1-8CEMERGENCY STOP SWITCHMTD IN WEATHERPROOFENCLOSURE @ 42" AFF1011HIGH VOLTAGE AND LOW VOLTAGE CONDUITS FOR GAS EQUIPMENT AND CANOPY LIGHTING SHALL BE RMC FOR A MINIMUM OF 10FEET ON EITHER END, INSTALLED UNDERGROUND, AND COVERED WITH NOT LESS THAN 24" OF COVER FROM TOP OF CONDUIT TOFINISHED GRADE. SIZE AND QUANTITY OF CONDUITS ARE TO BE VERIFIED IN THE FIELD. REFER TO PETROLEUM DRAWINGS FORADDITIONAL INFORMATION AND DETAILS.EVAPORATORUNIT #1H-8,10SD-25E-21CTEMPERATUREPROBE TO PLCD-24GFIWPD-28 D-26SEATING AREAF-25F-27CCF-33F-3399VESTIBULESINGLE GANG J-BOX ABV CLG W/1" C. TO UTILITY ROOM ANDCAPPED FOR FUTURE AIR CURTAIN.JH-41WALK-IN TAKE HOME COOLERHTRS - DOOR & SIDE WINDOWSWALK-INTAKE-OUTCOOLERSMTD @ 18" &11'-4" AFFCF-10MTD @ 5'-10" AFF(APPROXIMATELY)see note #7.D-17 D-19 D-21,23 H-27FREEZER ALARMS& HTR TAPESC- 2 8 MTD BTM OF CNTRLPNL @ 7'-0" AFFC- 2 9 4 RUNS (4-350 MCM COPPER) IN 4" PVCCONDUITS UNDERGROUND) OR 4" R.G.S.CONDUITS WHERE EXPOSED.) ALLCONDUCTORS TO BE TYPE (THHN/THWN -2)90 DEGREE C INSULATION TO MDPELECTRIC COMPANYCT'S AND METER400A-3P-NF, 240V, NEMA 3r, HEAVY-DUTYDISCONNECT SWITCH MTD ON EXTERIORWALL NEXT TO CT CABINET FOR HOOK UPTO PORTABLE GENERATOR BY OTHERS.WPTAKE homeCOOLER(FOR MUZAK)C7plc TEMPPROBEcooler TEMPPROBEto tempgauge30' lead1616to tempgauge30' leadplc temp probecooler temp probefreezertemp probeplc tempprobe16to temp gauge30' leadplc TEMPPROBEcoolerTEMPPROBE16to tempgauge30' lead(2) D- 4 1 TEMPERATUREPROBE TO PLCD-30 F-19 F-15 F-13 F-11 D - 1 4 C-35,37 C-31,33 C-39,41 C-36C LEFTSIDERIGHTSIDECCB- 1 8 C102"181817(1) 2" DIA. OVERHEAD L.V.CONDUIT TO OFFICEC- 2 2 , 2 4 C- 1 0 C- 1 2 , 1 4E-1CMTD UNDERCOUNTER10.508. 3 1 8. 3 1 8. 3 1 8. 3 18.75(4)8.451.29 1.29 8.46 8.45(2) f-16J EMPTY FLOOR BOX WITHBLANK COVER PLATE. FORFUTURE DATA AT THIS LOCATIONFBFBJFBf-14JJFB6.61TO BE MTD 6" ABVSHELF SEE E-8 FORLOCATIONC - 1 3 , 1 5C - 1 8 C - 1 7 , 1 9 C - 2 0TO BE MTD 6" ABVSHELF SEE E-8 FORLOCATIONC - 1 1 D - 9 , 1 1 D - 3 4 , 3 6C D - 2TURBOCHEF CONTROLSIGNAL TO PLCC - 2 5 , 2 7REFER TO DWG E-9 FORRECPT LAYOUT & CIRCUITSREFER TO DWG E-9 FORRECPT LAYOUT & CIRCUITS10.5010.506.1 4 4.1 3 6.1 5 6.1 0 6.1 3 4.1 4 6.1 4 4.1 3 F - 1 , 3 F - 2 , 4 F - 5 , 7 F - 6 , 8 8. 6 7 8. 6 7 8.24 8.69 8.07 8.37 8.24 MTD BLW 8.22C 8.64 MTD BLW 8.22C MTD BLW8.22C 8.16 8.05 7.25 (2)11.4010.2011.1011.1011.30 11.20B-3 INSECT LIGHT TRAP,MTD @ 92" AFF11.44 5.1 5 A 5. 0 1 5.11 C- 3 4 1.861.641.721.721.608.12B8.1210 . 5 0 3.1 9 8. 9 2 3.1 3 10 . 5 0 4. 6 2 10 . 5 0 3.1 5 4. 3 5 4. 3 7 3.2 1 4.1 3 4. 3 6 general electrical NOTES:1.ALL ORDER POINT MONITORS, ITEMS #10.50, SHALL BE COMPLETE WITH DATA BOX BESIDE POWER OUTLET.2.ALL RECEPTACLES FOR ORDER POINT MONITORS, ITEMS #10.50, SHALL BE DOUBLE DUPLEX TYPE RECEPTACLES.3.ALL ORDER POINT MONITORS, ITEMS #10.50, (DOUBLE DUPLEX RECEPTACLES & COMMUNICATIONS OUTLETS) ON THE KNEEWALL SHALL BE LOCATED IN THE WALL FACING THE SALES AREA. COORDINATE WITH OWNER.4.UNLESS OTHERWISE INDICATED, OUTLET BOXES IN WALLS SHALL BE LOCATED WITH THE CENTERLINE AT THE FOLLOWINGELEVATIONS ABOVE FINISHED FLOOR: WALL SWITCH OUTLETS: 4'-0", CONVENIENCE OUTLETS: 1'-6", OR 6" ABOVE BACKSPLASH OF COUNTERTOPS, MISCELLANEOUS EQUIPMENT OUTLETS: MANUFACTURER'S RECOMMENDATIONS.5.ALL RECEPTACLES SHOWN ON SALES FLOOR AREA SHALL BE IVORY IN COLOR, AND ALL RECEPTACLES SHOWN IN SEATINGAREAS SHALL BE bROWN IN COLOR. COORDINATE EXACT RECEPTACLES TO BE IVORY IN COLOR WITH OWNERREPRESENTATIVE.6.ALL 120 VOLT, SINGLE PHASE, 20 AMP, RECEPTACLES IN THE KITCHEN AND PREP AREAS SHALL BE GROUND FAULTCIRCUIT-INTERRUPTER PROTECTED TYPE RECEPTACLES. NEC 210.8(B)7.RECEPTACLES FOR ICE MERCHANDISERS, ITEM #11.75, SHALL BE SIMPLEX TYPE RECEPTACLES POWERED BY GFCI TYPECIRCUIT BREAKERS. REFER TO PANEL SCHEDULES.8.ON EACH PIECE OF ELECTRICAL EQUIPMENT ( INCLUDING BUT NOT LIMITED TO PANELBOARDS AND DISCONNECT SWITCHES )PROVIDED AS PART OF THIS STORE SHALL BE IDENTIFIED BY A MICARTA IDENTIFICATION TAG PERMANENTLY ATTACHEDTO THE EQUIPMENT WITH SELF-THREADING STAINLESS STEEL SCREWS AND SHALL INDICATE BY NAME THE EQUIPMENT ANDTHE CIRCUIT THAT SERVES SUCH EQUIPMENT. LETTERING ON IDENTIFICATION TAGS SHALL BE A MINIMUM OF 1/4" IN HEIGHT.9.RECEPTACLES AND SWITCHES SHALL BE IDENTIFIED AT EACH DEVICE WITH AN APPROVED IDENTIFICATION TAGPERMANENTLY ATTACHED TO THE WALL PLATE AND SHALL INIDCATE THE PANELBOARD AND CIRCUIT NUMBER FROMWHICH IT IS SERVED. USE MACHINE-PRINTED, DURABLE WIRE MARKERS AND TAGS INSIDE EACH OUTLET BOX.10.REFER TO 'STORE PLC CONTROL SYSTEM' SHOP DRAWINGS BY ENERTECH ASSOCIATES FOR WIRING DIAGRAMS ANDADDITIONAL DETAILS AND INFORMATION.1011PROVIDE RECEPTACLE, EMPTY CABLE BOX AND RACEWAY IN CEILING FOR TELEVISION CABLE. LOCATION OFRECEPTACLE AND CABLE BOX SHALL BE 12" FROM wall OF SEATING AREA AND SHALL NOT BE INSTALLED ABOVEANY CEILING. EXACT LOCATION SHALL BE DETERMINED AND COORDINATED IN THE FIELD WITH SHEETZ PERSONNEL.13WIRE TO DRY CONTACTS ON DOOR OPERATOR ELECTRONIC CONTROL MODULE TO FIRE ALARM CONTROL PANEL.PROVIDE (2) #18 AWG STP IN 1/2" CONDUIT.DOOR OPERATOR ELECTRONIC CONTROL MODULE.456PEDESTAL WITH INTEGRATED PUSH PLATE7MOTOR/DOOR OPERATOR w/ ELECTRONIC CONTROL MODULE, 120V-1∅-240 WATTS.LABEL MINDER, 120V-1∅, (POWER & DATA) MOUNTED AT 54" ABOVE FINISHED FLOOR.8CONTRACTOR SHALL COORDINATE ALL CONDUIT AND PIPING LOCATED IN THIS AREA WITHIN THE WALL WITH OTHER TRADES.912ROOM TEMPERATURE SENSOR FOR TURBO CHEF EXHAUST FAN & FRYER EXHAUST FAN CONTROL PANELS MOUNTED AT 7'-0"ABOVE FINISHED FLOOR.HOOD SUPPRESSION PULL STATION MOUNTED AT 48" ABOVE FINISHED FLOOR. PULL STATION SHALL BE SUPPLIED AND WIREDBY HOOD SUPPRESSION CONTRACTOR.13141715161819COORDINATE ALL FINAL LOCATIONS OF RECEPTACLES AND DATA OUTLETS WITH CUSTOM CASEWORK IN FIELD.20KEY NOTES:temperature probes to be located at return air on evaporator, within 6" of manufacturers temperature sensor.21PROVIDE (1) 2" pvc overhead from comm/data server area to front of store for wireless access points.coordinate conduit location with sheetz construction personnel.22PROVIDE (1) 1" pvc overhead from wall to sales area for wireless access points. coordinate conduit locationwith sheetz construction personnel.2PROVIDE 120V FINAL CONNECTION FOR DISHMACHINE (B-23). SEE GENERAL ELECTRICAL NOTE #10.DISHMACHINE HOT WATER BOOSTER PUMP DISC. SW, 60A-3P-NF, 240V MTD @ 4' AFF.DISHWASHER DISC. SW, 20A-1P WITH THERMAL OVERLOADS MTD ON WALL @ 4' AFF25mOUNT RECEPTACLE SIDEWAYS ON WALL. BOTTOM OF RECEPTACLE SHALL BE MOUNTED @ 34" ABOVE FINISHED FLOOR.MOUNT RECEPTACLE ON WALL. BOTTOM OF RECEPTACLE SHALL BE MOUNTED @ 40" ABOVE FINISHED FLOOR26MOUNT SECURITY CABINET TIGHT TO CEILING WITHIN WORK ROOM AREA.CHECKOUT COUNTER GENERAL ELECTRICAL NOTES:1.ALL FRONT COUNTER RECEPTACLES SHALL BE DOUBLE DUPLEX TYPE RECEPTACLES LABELED W/ CIRCUIT NO. & PANEL.2.ALL DATA CABLING SHALL BE PROVIDED IN THE TOP RACEWAY AND ALL BRANCH CIRCUIT WIRING SHALL BE PROVIDED INTHE LOWER RACEWAY.3.ALL DATA OUTLET BOXES SHALL BE MOUNTED AT 30" AFF AND ALL POWER OUTLET BOXES SHALL BE MOUNTED AT 20" AFF.1927272020202123BRANCH CIRCUIT (E-10) SHALL BE CONTROLLED BY EMERGENCY FUEL SHUT-OFF SWITCH242526278. 3 2 F - 1 2 JSINGLE GANG J-BOX ABVCLG W/ 1" C. TO UTILITY ROOMAND CAPPED FOR FUTUREAIR CURTAIN.88.46 27MOUNT RECEPTACLE ON WALL. BOTTOM OF RECEPTACLE SHALL BE MOUNTED @ 48" ABOVE FINISHED FLOOR(2)2825A-22fryer oil wastemanagement system,120v-1∅, mtd @ 60" affGFIWPA-24fryer oil wastemanagement system,tank heat trace,120v-1∅, mtd @ 60" affGFIWP(2)8.45 FBFBTRTRTRTRTRTRTRTRTRGF I GF I G F I G F I G F I G F I G F I G F I G F I G F I G F I G F I G F I G F I G F I G F I G F I G F I G F I GF I G F I G F IEVAPORATORUNIT #2provide additional spare conductor for e-stop back to electrical room, coordinate with petroleum contractor.12GFIGFIWPHELPHELPHELPHELP282828extend conductors to transformer located in utility room.CHECK STANDREFER TO DRAWING E-9 FOR RECPTSLAYOUT AND CIRCUITS FOR TOUCHSCREENS (10.60), ORDER MONITORS(10.50) AND DIGITAL SCREENS ONSALES AREA SIDE OF WALLGFIMTD ABV STONE SILLBOTTOM OF RECPTMTD @ 3'-3" AFFHIGHHIGHTRASHDROPHIGHupMTD ABV STONE SILLBOTTOM. RECPT MTD@ 3'-3" AFFPP4MA-18 (3) #12 MAX. IN1/2" CONDUIT1MTD @ 18" &8'-0" AFFE-26 CPPPP2MPPS(2) #1836SINGLE PHASE DISCSWITCH MTD @ 72" AFF316SSINGLE PHASE DISCSWITCH MTD @ 72" AFF(2) #185DOUBLE PUSH PLATE MOUNTED IN ONE (1) 2 GANG ELECTRICAL BOX IN VESTIBULE. ELECTRICAL BOX SHALL BE MOUNTEDNO HIGHER THAN 48" AFF AND NO LOWER THAN 15" aff. (ANSI 117.1 FIG. 308.3.1) COORDINATE exact LOCATION IN FIELD.TRE-18 E-10 112" CONDUIT W/ GOOSENECK TURNDOWNFOR LOTTERY COMMUNICATION (VERIFYLOCATION IN FIELD)3" PVC FOR CABLE4" PVC FOR PHONEE-2D-32E-2510.7024POS PNL 'b'PNL 'E'PNL 'F'PNL 'C'PNL 'D'PNL 'A'PNL 'H'PNL 'G2'PNL 'G1'G1-4E-14 PLC CONTROLLER (ABOVE)& LIGHTING CONTACTORS (BELOW)petroleum equipment bypetroleum contractorB-2924"11.90 GFIwpWHB-17 11.80 WATER FILTERS RECPTMTD HIGH ON WALLB-14GFIB-36CIRC PUMP,120V-1∅, 112HPGFIB-1INSECT LIGHT TRAP,MTD @ 76" AFF11.00B-26S GFIB-5TANK MONITOR SEEDETAIL SHEET E-9L.V. MTD @96" AFF42"CHELPA-26PLC ALARM4'-0" AFFB-24 8.53 28B-740"C40"40"10.65EMPLOYEEUTILITY SPACEE-6 E-12 E-8 G1-2 E-9 E-17 INTERCOM E-1 CCCCCCG1-8EMERGENCYfuel Shut-offSWITCH10.50 10.30 10.25SAFE/CASHDEPOSITORY,120V-1Ø.10.30 10.30 E-27 CC23E-19 E-15 12HELP28SAFE/CASHDEPOSITORY,120V-1Ø.HELP28HELP2840"E-23C8SB-231514137.5 0 B-9,11,13M MTD @ 6" BELOWFINISHED CEILINGMTD @ 6" BELOWFINISHED CEILING22USBUSBUSBUSBUSBUSBUSBUSBUSBUSBTRTRGFITRGFITRCGFIFSSS3GFIWPTRHELPSOSFBDUPLEX TAMPER RESISTANT RECEPTACLEw/ TWO(2) USB PORTSDUPLEX GFCI WEATHER RESISTANT RECEPTW/ WEATHER PROOF COVERDUPLEX GFCI RECEPTACLEDOUBLE DUPLEX RECEPTACLEDUPLEX RECEPTACLE1 POLE SWITCH3 WAY SWITCHWALL SWITCH OCCUPANCY SENSORHELP BUZZERCOMPUTER OUTLETFLOOR BOXHUBBELL-BRYANTHUBBELL-BRYANTHUBBELL-BRYANTHUBBELL-BRYANTHUBBELL-BRYANTHUBBELL-BRYANTHUBBELL-BRYANTHUBBELL-BRYANTHUBBELL-BRYANTREFER TO SHEET E-4MANUFACTURERCAT. NO.CR20(2) CR20GF20GFTR20RW57350HUBR-USB20LICS120CS320AT120DESCRIPTIONSYMBOLWPWEATHER RESISTENT SIMPLEX RECEPTACLEW/ WEATHER PROOF COVERHUBBELL-BRYANTHBL5361WRWALL SWITCH DIGITAL TIMERHUBBELL-BRYANTDT2000WSDT55 SERIESUSBTRDUPLEX TAMPER RESISTANT GFCI TYPERECEPTACLEHUBBELL-BRYANTHUBR-GFTRST20IGFITRDUPLEX TAMPER RESISTANT TYPERECEPTACLEHUBBELL-BRYANTHUBR-CR20ITRWALL SWITCH with pilot lightSplsingle phase manual motor starterSmw/ thermal overloadssquare d2510-fg2pby othersELECTRICAL EQUIPMENT SCHEDULEIONIZATION TYPE SMOKE DETECTORw/ battery back-upBRK ELECTRONICS9120Bfloor box at this location shall be a hubbell CFBS1R4PFB floor box with a CFBS1RR4CUP MOUNTING CUP, S1R4SPSTYLEMOUNTING PLATE, CFBS1R4CVRBRS BRUSHED BRASS cover, AND GF20 GROUND FAULT INTERRUPTER TYPE RECEPTACLE.SINGLE PUSH PLATE mOUNTED IN SINGLE GANG ELECTRICAL BOX. ELECTRICAL BOX SHALL BE MOUNTED NO HIGHER THAN 48"AFF AND NO LOWER THAN 15" aff. (ANSI 117.1 FIG. 308.3.1) COORDINATE exact LOCATION IN FIELD.FBF-21MOUNTED ABOVE COOLERFOR DRAIN PAN OVERFLOWSENSOR. SENSOR BY OWNER.11.00B-28SMH-35,37AS NOTEDWSP4772-R-E3E-3 ELECTRICAL EQUIPMENT PLAN 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 LIGHT BOLLARDPPPOWER LEGENDMOTOR CONNECTIONMFINAL CONNECTION BY EC TO EQUIPMENTNON-FUSED DISCONNECT SWITCHSPECIAL PURPOSE RECEPTACLESINGLE PHASE MANUAL MOTOR SWITCH WITH OVERLOADSSMLIGHTING LEGEND1' X 4' LED TROFFER LIGHT FIXTUREAFBB1TBATTDDLED RECESSED DOWNLIGHT FIXTUREOOSURFACE MOUNTED LED LIGHT FIXTURE FORWALK-IN COOLERS & FREEZERSB-K LIGHTING, #VS-MR-O-BZP-9 BRONZE FINISH,TRANSFORMER TR 500-12- LIGHT BULB-1 EYE #75720EMERGENCY LIGHT WITH BATTERY PACKEXTERIOR WALL MOUNTED LIGHT FIXTURELED EXIT SIGNMEXTERIOR WALL MOUNTED LIGHT FIXTUREXQQ30" UNDER CABINET TASK LIGHTINGFIXTURE AT TRAINING DESKBATTZZEMERGENCY BATTERY PACK ONLYPPAUTOMATIC DOOR OPERATOR PUSH PLATEBRANCH CIRCUIT WIRINGLIGHTED SWITCHED CIRCUIT WIRINGHOMERUN WIRING BACK TO PANELBOARDSWITCH LEG WIRINGEXTERIOR WALL MOUNTED LIGHT FIXTURE MOUNTEDABOVE EGRESS DOORSX11' X 4' LED INDUSTRIAL LIGHT FIXTUREA3GG1EMERGENCY EXTERIOR REMOTE SINGLE HEADGG2EMERGENCY EXTERIOR REMOTE double HEADsEE1EMERGENCY INTERIOR REMOTE SINGLE HEADEE2EMERGENCY INTERIOR REMOTE double HEADsled PENDANT LIGHT FIXTURE at seating area BYOWNER, INSTALLED BY ECNGled PENDANT LIGHT FIXTURE at seating area BYOWNER, INSTALLED BY ECUUSURFACE MOUNTED LED LIGHT FIXTURE FORWALK-IN TAKE-OUT COOLERSDIE CAST GIMBAL RING TRACK HEADFOOD SERVICE EQUIPMENT SCHEDULESYMBOL1.291.551.641.561.861.521.721.511.603.133.153.193.214.134.144.354.364.374.625.015.01A5.01B5.115.155.15A6.106.136.146.156.617.257.508.058.078.12A8.12B8.168.22C8.248.318.328.378.458.468.538.53A8.648.678.698.758.92NOTE FOR ITEM 7.25:NOTE FOR ITEM 6.61:POINT OF SALE EQUIPMENT CONNECTION SCHEDULE SYMBOL10.2010.2510.3010.5010.6010.6510.70NOTE FOR ITEM 10.70:STORE EQUIPMENT CONNECTION SCHEDULE SYMBOL11.0011.1011.2011.3011.4011.4411.4511.6011.7511.8011.90QUANTITY211111211211132111111111111211111111143412821112111QUANTITY1137411QUANTITY1211111321-1DESCRIPTIONMILK / CREAM DISPENSERWALK-IN COOLER CONDENSERWALK-IN COOLER EVAPORATORWALK-IN COOLER LIGHTSWALK-IN COOLER HEATERSWALK-IN FREEZER CONDENSERWALK-IN FREEZER EVAPORATORWALK-IN FREEZER LTS/HEATERSWALK-IN FREEZER ALARM/HEAT TAPETAKE HOME COOLER CONDENSERTAKE HOME COOLER EVAPORATORTAKE HOME COOLER LIGHTSTAKE HOME COOLER 10 DOOR LIGHTSTAKE HOME COOLER 10 DOOR HEATERSWALK-IN TAKE OUT COOLER CONDENSERWALK-IN TAKE OUT COOLER EVAPORATORWALK-IN TAKE OUT COOLER LIGHTSWALK-IN TAKE OUT HEATERSBLENDERWORKTOP REFRIGERATORWORKTOP REFRIGERATORSCALEMICROWAVERAPID COOK OVENFRY DUMP48" 4-DRAWER WORK TOP FREEZERDUAL FRYER BATTERYLARGE ROLLER GRILLFRYER CONTROL PANELFRYER MAKE-UP AIR (EF-4M)FRYER EXHAUST FAN (EF-4)FIRE SUPPRESSION SYSTEMTURBO CHEF CONTROL PANELTYPE 2 HOOD SYSTEM OVER TURBO CHEFHOT FOOD HOLDING CABINET27" WORKTOP FREEZERCUTTINGTOP REFRIGERATORCHEESE DISPENSERBAKERY CASEICE CREAM MERCHANDISERDISH MACHINE WITHTEMP-SURE HOT WATER BOOSTER PUMP1 BARREL ICE CREAM DISPENSER (AIR COOLED)2 BARREL ICE CREAM DISPENSER (AIR COOLED)ICE MACHINE CONDENSING UNITFOLLETT ICE DIVERTER SYSTEMBEVERAGE DISPENSERUNDER COUNTER COMPACT WATER BOOSTERSELF-CONTAINED F.U.B. MACHINE - 2 HEADDUAL SOFT HEAT BREWERMULTI-HOPPER GRINDER & STORAGE SYSTEMICED BREWER (POWERED)MULTI-SWEETNER DISPENSERMAGIC COWICE CUBE MACHINECVD CONDENSING UNIT4 FLAVOR FCB DISPENSERRTE MERCHANDISERMILKSHAKE BLENDING BARIMIX HOT BEVERAGE SYSTEM W/ 5 HOPPERSESPRESSO MACHINETWO(2) HUBBELL PFB1 FLOOR BOX W/ PFBA1A ADAPTOR, HUBBELL CR20 RECEPTACLE (F-16), S3925DUPLEX COVER AND S5016 ADAPTOR RING FOR POWER TO ICE CREAM NOVELTY CASE. TWO(2) HUBBELL PFB1 FLOORBOX W/ PFBA1A ADAPTOR, S3925 DUPLEX COVER AND S5016 ADAPTOR RING FOR FUTURE DATA AT THISLOCATION.ONE(1) HUBBELL PFB1 FLOOR BOX W/ PFBA1A ADAPTOR, HUBBELL CR20 RECEPTACLE (F-14), S3925DUPLEX COVER AND S5016 ADAPTOR RING FOR POWER TO BAKERY CASE. TWO(2) HUBBELL PFB1 FLOORBOX W/ PFBA1A ADAPTOR, S3925 DUPLEX COVER AND S5016 ADAPTOR RING FOR FUTURE DATA AT THISLOCATION.DESCRIPTIONLOTTERY MACHINELOTTERY COUNTERTOP TICKET DISPENSERCASH REGISTER / GASORDER MONITORTOUCH SCREENEMPLOYEE KIOSK W/ MOUNTING ARMSTORE SERVERSTORE SERVER SHALL RUN THROUGH E-STOP CONTACTOR.DESCRIPTIONAIR CURTAIN - 42"ADA COMPLIANT HAND DRYERFAX MACHINE (IN OFFICE)TV SECURITYATMINSECT LIGHT - PUBLIC AREASINSECT LIGHT - WORK AREASTOE SPACE HEATERICE MERCHANDISER (8'-0")GAS HOT WATER HEATERWATER CONDITIONER (FUTURE)LOW PRESSURE ALARM FOR FILTER SYSTEMMANUFACTURERSURESHOTBOHNBOHNBOHNBOHNBOHNBOHNBOHNBOHNVITAMIXBEVERAGE-AIRBEVERAGE-AIRISHIDAAMANATURBOCHEFGLO-RAYCONTINENTALFRYMASTERCONNOLLY BY NEMCOCAPTIVE-AIRECAPTIVE-AIRECAPTIVE-AIREANSULCAPTIVE-AIRECAPTIVE-AIREDUKEBEVERAGE-AIRBEVERAGE-AIRSTARBAKEREXCELLENCE INDUSTRIESCMACMATAYLORTAYLORFOLLETTFOLLETTLANCERSHURFLOBUNNBUNNBUNNWILBUR CURITS Co.SURE SHOTEIEIOMANITOWOCMANITOWOCCORNELIUSHILL PHOENIXF'REAL/SILVER KINGBUNNUNICMANUFACTURERSUPPLIED BY STATESUPPLIED BY STATEBY OWNERRADIANT SYSTEMSRADIANT SYSTEMSAAEONBY OWNERMANUFACTURERBERNERBOBRICKBY OWNERBY OWNERDIEBOLDGARNDERWHITMIRE/MICRO-GENTPILEERBRADFORD WHITE-MODELAC220-SSBHS 015X6CADT 130BKBZS 030L6CLET 120HKBZS 045M6CADT 180BKBZS015M6CSM179BEON-COUNTER: 36019WTR60-AUCR48A-23AC4000RC17STORNADOGRFHS-21SWF48-FBFP217-2TCRSC8045ND76NCA8FAR-102-UL-300DU30HFAFWM3-42-208WTF27ASP48-18HPDE1HPBWU-40DDS48LOW TEMP EST-VENTLESSTEMP-SURE HEAT RECOVERYC709C717HCD1650IMDV-2 SERIESFS608025-933-237ULTR-2 CFV 3400.0520DUAL SH DBC 27850.00MHG (SST) 35600.0020TCNAC2-GPFC2613QY-1474CCVD 1475621460042OMNA----IMIX-5-BLKPONY 4MODEL- - - -- - - -- - - -M-100T-200ACP-5153- - - -MODELCHC10-1042AAB-7128- - - -- - - -1064ixWS-85VECTOR CLASSICTSH20J/TSH2TXL100UASXEF-100T-150E-3NA-- - - -ELECTRICALREQUIREMENTS120V-1Ph-1A208V-3Ph-10.375A208V-1Ph-3A120V-1Ph-3A120V-1Ph-8A208V-3Ph-14.375A208V-1Ph-4.875A120V-1Ph-6A120V-1Ph-8A208V-3Ph-26.5A208V-1Ph-4.875A120V-1Ph-2A120V-1Ph-6A120V-1Ph-5.7A208V-3Ph-12.875A208V-1Ph-8.5A120V-1Ph-2A120V-1Ph-6A120V-1Ph-15A1/4 HP-120V-1Ph-7.5A1/5 HP-120V-1Ph-4.2A120V-1Ph-2A208V-1Ph-13A208V-1Ph-28.8A120V-1Ph-10A1/3 HP-120V-1Ph-7A208V-3Ph-48A (EACH)120V-1Ph-13A120V-1Ph-3A1/2 HP-208V-1Ph-1.8A208V-1Ph-6.15A120V-1Ph-4A120V-1Ph-4A.18 HP-120V-1Ph-2A208V-1Ph-11.5A120V-1Ph-6A120V-1Ph-5A120V-1Ph-6.25A120V-1Ph-3A120V-1Ph-7.6A120V-1Ph-16A208V-3Ph-25A208V-1Ph-24A208V-1Ph-26A (LEFT)208V-1Ph-23A (RIGHT)208V-1Ph-29.9A120V-1Ph-1.5A120V-1Ph-15A120V-1Ph-1.0A120V-1Ph-12A120/208V-1Ph-32.7A120V-1Ph-11A120V-1Ph-13.8A120V-1Ph-0.6A120V-1Ph-15A120V-1Ph-1.1A208V-1Ph-14.1A208V-1Ph-30A120V-1Ph-24A120V-1Ph-8A120V-1Ph-15A208V-1Ph-21.6A (4500 WATTS)ELECTRICALREQUIREMENTS120V-1Ph-4A12V0-1PH-4A120V-1Ph-2A120V-1Ph-3A120V-1Ph-6A120V-1Ph-2A120V-1Ph-8AELECTRICALREQUIREMENTS120V-1Ph-6.2A208V-1Ph-6.8A120V-1Ph-2A120V-1Ph-2A120V-1Ph-6A120V-1PH-0.125A (15 WATTS)120V-1PH-0.55A (35 WATTS)208V-1Ph-7.2A120V-1Ph-7.5A120V-1Ph-6.2A-120V-1Ph-0.5ACONNECTIONHEIGHTCOORDINATE W/ CASEWORK MFRROOFTOP78" AFFDIRECT CONNECTIONDIRECT CONNECTIONROOFTOP78" AFFDIRECT CONNECTIONDIRECT CONNECTIONROOFTOP78" AFFDIRECT CONNECTIONDIRECT CONNECTIONDIRECT CONNECTIONROOFTOP78" AFFDIRECT CONNECTIONDIRECT CONNECTION48" AFF18" AFF18" AFF48" AFF72" & 60" AFF48" AFF48" AFF18" AFF18" AFF48" AFFROOFTOPROOFTOP102" AFFROOFTOP48" AFF18" AFF18" AFF48" AFF18" AFF18" AFFDISCONNECT SWITCH @ 48" AFFDISCONNECT SWITCH @ 48" AFF84" AFF84" AFF84" AFFROOFTOPABOVE COOLERCOORDINATE W/ CASEWORK MFRCOORDINATE W/ CASEWORK MFRCOORDINATE W/ CASEWORK MFRCOORDINATE W/ CASEWORK MFRCOORDINATE W/ CASEWORK MFRCOORDINATE W/ CASEWORK MFRCOORDINATE W/ CASEWORK MFRCOORDINATE W/ CASEWORK MFR68" AFFROOFTOPCOORDINATE W/ CASEWORK MFR6" AFFCOORDINATE W/ CASEWORK MFRCOORDINATE W/ CASEWORK MFR48" AFFGENERAL ELECTRICAL NOTE:CONNECTIONHEIGHT18" AFF18" AFF18" AFFREFER TO SHEET E-7 & E-8 FOR HTS36" AFF40" AFF18" AFFCONNECTIONHEIGHT78" AFF48" AFF40" AFF78" AFF18" AFF92" AFF92" AFFIN TOE KICK5'-10" AFF7'-0" AFF-9" AFFNEMACONFIGURATIONNEMA 5-20Rn/an/an/an/an/an/an/an/an/an/an/an/an/an/an/an/an/aNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 6-20RNEMA 6-30RNEMA 5-20RNEMA 5-20RNEMA 15-60RNEMA 5-20Rn/an/an/an/an/an/aNEMA 6-15RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20Rn/an/aNEMA L6-30RNEMA L6-30RNEMA L6-30Rn/aNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 14-50RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20Rn/aNEMA L6-30RNEMA L5-30R(3) NEMA 5-20RNEMA 5-20RNEMA L6-30RCONTRACTOR SHALL PROVIDE PLUG AS INDICATED ON SPECIFIEDEQUIPMENT IN FOOD SERVICE EQUIPMENT SCHEDULE ABOVE.NEMACONFIGURATIONNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMACONFIGURATIONN/AN/ANEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20RNEMA 5-20RN/ANEMA 5-20RN/ANEMA 5-20RNEMA 5-20RWIRE SIZE(2) #12 & (1) #12 GRD - 3/4" C.(3) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(3) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(3) #6 & (1) #10 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(3) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #10 & (1) #10 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(3) #4 & (1) #10 GRD - 1" C.(2) #12 & (1) #12 GRD - 3/4" C.(3) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(3) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1)#12 GRD - 2/4" C.(3)#8 & (1)#10 GRD - 1" C.(3)#10 & (1)#10 GRD - 3/4" C.(3)#10 & (1)#10 GRD - 3/4" C.(3)#10 & (1)#10 GRD - 3/4" C.(2)#6 & (1)#10 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(3) #6 & (1) #10 GRD - 1 1/2" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #8 & (1) #10 GRD - 3/4" C.(2) #10 & (1) #10 GRD - 3/4" C.(2) #10 & (1) #10 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #10 & (1) #10 GRD - 3/4" C.WIRE SIZE(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.WIRE SIZE(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #8 & (1) #10 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(3) #3 & (1) #18 GRD - 1 1/4" C.(2) #12 & (1) #12 GRD - 3/4" C.(2) #12 & (1) #12 GRD - 3/4" C.TERMINATECIRCUIT WITHHUBBELL CR20 RECPTSQUARE D DU321RB SWITCH (AT UNIT)HUBBELL 1222 SWITCH (AT UNIT)DIRECT CONNECTIONDIRECT CONNECTIONSQUARE D DU321RB SWITCH (AT UNIT)HUBBELL 1222 SWITCH (AT UNIT)DIRECT CONNECTIONDIRECT CONNECTIONSQUARE D DU322RB SWITCH (AT UNIT)HUBBELL 1222 SWITCH (AT UNIT)DIRECT CONNECTIONDIRECT CONNECTIONDIRECT CONNECTIONSQUARE D DU321RB SWITCH (AT UNIT)HUBBELL 1222 SWITCH (AT UNIT)DIRECT CONNECTIONDIRECT CONNECTIONHUBBELL GF20LA RECPTHUBBELL GF20LA RECPTHUBBELL GF20LA RECPTHUBBELL GF20LA RECPTHUBBELL HBL5461 RECPTHUBBELL HBL9630 RECPTHUBBELL GF20LA RECPTHUBBELL GF20LA RECPTHUBBELL HBL8460A RECPT (EACH FRYER)HUBBELL GF20LA RECPTDISCONNECT SWITCH SUPPLIED w/ UNITDISCONNECT SWITCH SUPPLIED w/ UNITDIRECT CONNECTIONDISCONNECT SWITCH SUPPLIED w/ UNITHUBBELL HBL5661 RECPTHUBBELL GF20LA RECPTHUBBELL PLUG ON EQUIP/GF20LA RECPTHUBBELL GF20LA RECPTHUBBELL GF20LA RECPTHUBBELL CR20 RECPTSINGLE PHASE DISC SW w/ THERMAL OVERLOADSSQUARE D DU322RB SWITCH (AT UNIT)HUBBELL HBL2620 RECPT / HBL2621 PLUGHUBBELL HBL2620 RECPT / HBL2621 PLUGHUBBELL HBL2620 RECPT / HBL2621 PLUGSQUARE D DU222RB SWITCH (AT UNIT)HUBBELL CR20 RECPTHUBBELL CR20 RECPTHUBBELL CR20 RECPTHUBBELL CR20 RECPTHUBBELL HBL8450A RECPTHUBBELL CR20 RECPTHUBBELL CR20 RECPTHUBBELL GF20LA RECPTHUBBELL GF20LA RECPTHUBBELL GF20LA RECPTSQUARE D DU221RB SWITCH (AT UNIT)HUBBELL HBL2320 RECPTHUBBELL HBL2610 RECPT / HBL2611 PLUG(3) HUBBELL CR20 RECPTHUBBELL CR20 RECPTHUBBELL HBL2620 RECPT / HBL2621 PLUGTERMINATECIRCUIT WITHHUBBELL CR20 RECPTHUBBELL CR20 RECPTHUBBELL CR20 RECPTHUBBELL CR20 RECPT - DOUBLE DUPLEXHUBBELL CR20 RECPTHUBBELL CR20 RECPTHUBBELL CR20 RECPTTERMINATECIRCUIT WITHSQUARE D 2510-FG2P (AT UNIT)DIRECT CONNECTIONHUBBELL CR20 RECPTHUBBELL CR20 RECPTHUBBELL CR20 RECPTHUBBELL GF20LA RECPTHUBBELL GF20LA RECPTDIRECT CONNECTIONHUBBELL GF20LA RECPTDIRECT CONNECTIONHUBBELL 5362B RECPTHUBBELL GF20LA RECPTSUPPLY FROMPANELBOARDF-11 F-13H-1,3,5H-7,9H-25H-13H-15,17,19H-21,23H-25H-27H-2,4,6H-8,10H-22H-24H-26H-29,31,33H-35,37H-39H-41D-14 D-16D-4D-12B-30C-13,15 C-17,19 C-21,23D-9,11 D-34,36C-9C-16C-1,3,5 C-2,4,6C-30 C-32C-10C-12,14C-22,24C-29C-26C-28C-25,27C-11C-18 C-20D-2F-14F-16B-23B-9,11,13C-39,41C-31,33C-35,37D-27,29D-25D-20D-18D-31 D-33 D-35F-1,3 F-2,4 F-5,7 F-6,8F-12D-5 D-7F-19F-15 F-17B-24B-20,22D-21,23D-39 D-41D-17 D-19F-9D-13,15SUPPLY FROMPANELBOARDE-11E-12E-6 E-8 E-9E-1E-5B-7E-10 (E-18 RUN THRU E-STOP CONTACTOR)SUPPLY FROMPANELBOARDB-26 B-28A-25,27 A-32,34E-3E-7E-21B-3B-1F-39,41H-30 H-32B-17B-29B-14AS NOTEDWSP4772-R-E4E-4 ELECTRICAL EQUIPMENT SCHEDULE 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 CONNECT RECPTTO PNL "E" CB #25CONNECT REcPTTO PNL "E" CB #2STORESERVERSTORESERVERUTILITY RMWALL CONNECTRECPT TOPNL "E"CB #18CONNECTRECPT TOPNL "E"CB #10TIGERCONTROLLERPOWER CONDITIONER/POWER BACK-UP FORTIGER CONTROLLERMOUNTED ON SHELFREQUIRED w/EIGHT OR MOREMPD DISPENSERSRED PLASTIC TAPE (3" WIDE) MARKED:"CAUTION BURIED ELECTRIC LINE BELOW ."DIRT W/ ROCKS NO LARGER THAN 2"IN ANY DIAMETER OR PEA GRAVEL.UNDERGROUND CONDUITS INSTALLATION DETAILNOTES:1.REFER TO ELECTRICAL DRAWINGS FOR SIZES OF CONDUITS. PROVIDE QUANTITY OFSPACERS AS REQUIRED TO SUPPORT ALL UNDERGROUND CONDUITS IN A TRENCH.2.PROVIDE 3" OF SPACE BETWEEN ALL CONDUITS (MINIMUM).3.CONDUITS SHALL BE SUPPORTED AT INTERVALS AS PER THE NEC ANDMANUFACTURER REQUIREMENTS.4.ALL SPACERS SHALL BE SECURELY ANCHORED AS PER MANUFACTURERREQUIREMENTS.NO SCALEUNDERGROUND CONDUIT SPACER DETAILNO scale3"3"3"PROVIDE BANDING ASREQUIRED TO PREVENTCONDUIT FROM FLOATINGDURING ENCASEMENT (TYP.)ELECTRICAL CONDUIT(TYP.)HI-IMPACT PLASTICBASE SPACER (TYP.)HI-IMPACT PLASTICCONDUIT SPACERS FORUNDERGROUND CONDUITSUNDERGROUNDCONDUIT (TYP.)COMPACTED FILL OR UNDISTRUBED EARTHFILLFINISHED GRADE3"12"36"3/4" & 1" rigid conduitsSUGGESTED SERVICE ENTRANCEEQUIPMENT LAYOUTnote:the electrical contractor shall coordinate racewayand conductor installation so that there are no morethan 29 conductors in any 24" section of raceway.notes:1. verify number of conduits in field.2. maintain minimum distance of 24" between vfc controllersand any data/signal equipment and wiringCAUTION:PANEL G1 ONLY - SERIES COMBINATION SYSTEMRATED 65,000 AMPERES. IDENTIFIED REPLACEMENTCOMPONENTS REQUIRED.BACK PLATE6 1/2"LOCATION OFSTUB-UP AREAcommunicationsservice equipment4" CONDUIT FOR CABLE4" CONDUIT FOR PHONEdefgITEM 'd' telephoneterminal blockITEM 'e' dsl boxITEM 'f' verizon boxITEM 'g' cable box4 RUNS (4-350 MCM COPPER) IN 4" PVC CONDUITSUNDERGROUND) OR 4" R.G.S. CONDUITS WHERE EXPOSED.) ALLCONDUCTORS TO BE TYPE (THHN/THWN -2) 90 DEGREE CINSULATION TO MDP (SEE SHEET E-2)vertical style seal-offsshall be used.KEEP PVC CONDUITSBESIDE MDP2" pvc conduit tomanagers office2" CONDUITS FORFUTURE CAMERASfinished floor1" CONDUITS FORFUTURE order pointsfinished ceilingWALL AAcommunicationsservice equipmentpetroleum equipment bypetroleum contractorMEDIA, GAS PRICE, LOWVOLTAGE, CAMERAS,MEDIA CLIENT CONDUITSWALL CONNECT TO DEDICATEDRECEPT TO PANEL G1 CB #4MPD AND KERO SUMP SENSORS,TANK PROBES, INTERSTITIALSENSORS, & SITE WELLSVEEDER ROOT CONDUITSSHALL BE 2" RIGID STEELDRIVE THRU(MIN.)24"finished floorfinished ceilingWALL corner of wallopen towork roomWALLfinished floorfinished ceilingbbccBREAKOUTMODULE41086 975321FUSE5ADNGCPNCP CPC4P3P2P4P6P5LP1A4PB1A1A1A1A2P1PLMBBBBEMB1A3PGNDN1A1A5P6PBBC31CC2EM1MEME23B6ME4EM5BA56BA45B3A41BA21AB2A3N(14)31(-)5(+)RELAY BASE 2(12)(11)4(14)31(-)5(+)RELAY BASE 2(12)(11)4(14)31(-)5(+)RELAY BASE 2(12)(11)4(14)31(-)5(+)RELAY BASE 2(12)(11)4(14)31(-)5(+)RELAY BASE 2(12)(11)41(-)5(+)RELAY BASE (14)32(12)(11)41(-)5(+)RELAY BASE (14)32(12)(11)4P1 DISPENSER#DISPENSER#DISPENSER#DISPENSER#DISPENSER#DISPENSER#DISPENSER#DISPENSER#DISPENSER#DISPENSER#DISPENSER#DISPENSER#PDC-1023LA1X2 REPLACE FUSE WITHSAME TYPE AND RATINGType/Size or equivalent: AGC1A, 250V PDC-1023LA1X2REPLACE FUSE WITHSAME TYPE AND RATINGType/Size or equivalent: AGC1A, 250V120 VOLT CONTROLWIRING ONLYPDC-1022LA1X2 120 VOLT CONTROLWIRING ONLYPDC-1022LA1X2 120 VOLT CONTROLWIRING ONLYPDC-1022LA1X2LOW VOLTAGEWIRING ONLYPDC-1021LA1X2LOW VOLTAGEWIRING ONLYPDC-1021LA1X2LOW VOLTAGEWIRING ONLYPDC-1021LA1X2LOW VOLTAGEWIRING ONLYPDC-1021LA1X2LOW VOLTAGEWIRING ONLYPDC-1021LA1X2LOW VOLTAGEWIRING ONLYPDC-1021LA1X2"USE COPPER CONDUCTORS ONLY"Equipment Grounding TerminalBorne de m.a.l.t. de l'appareilTerminal de tierra del equipo80043-335-01 EQUIPMENT GROUNDING TERMINALTerminalWire bindingscrewWire RangeAWG CU-ALTorquelb-in.40271-854-01 LOW VOLTAGEWIRING ONLYPDC-1021LA1X2LOW VOLTAGEWIRING ONLYPDC-1021LA1X2PDC-1023LA1X2REPLACE FUSE WITHSAME TYPE AND RATINGType/Size or equivalent: AGC1A, 250V"USE COPPER CONDUCTORS ONLY"ABCD BACDDISP DISP DISP DISP SchneiderElectricPart #LVDDMB-500SchneiderElectricPart #LVDDRB-500SchneiderElectricPart #LVDDRB-500 AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-HN HN HN HNGGABCDBACDDISP DISP DISP DISP SchneiderElectricPart #LVDDMB-500SchneiderElectricPart #LVDDRB-500SchneiderElectricPart #LVDDRB-500 AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-HN HN HN HNGGABCDBACDDISP DISP DISP DISP SchneiderElectricPart #LVDDMB-500SchneiderElectricPart #LVDDRB-500SchneiderElectricPart #LVDDRB-500 AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-AD2+DD+DD-AD2-CD+CD-ADI+ADI-I+I-IS+IS-HN HN HN HNGGS1S2S3S42 X 4 WIREWAY 1236784911121314161718195101520S5S62 X 4 WIREWAY N DMEX11 DMEX12N DMEX10BLOWN5A 250V2AC2221C1211C1C21A SERVICE ONP4P3P2 NETWORK BUSCONTROLDISP PWRLIGHT PWRP1 FUSEBLOWN 5A 250V2AC2221C1211C1C21ASERVICE ONP4P3P2 NETWORK BUSCONTROLDISP PWR LIGHT PWRP1 FUSEBLOWN5A 250V2AC2221C1211C1C21A SERVICE ONP4P3P2 NETWORK BUSCONTROLDISP PWRLIGHT PWRP1 FUSENNDMEX2 DMEX1NDMEX3BLOWN5A 250V2AC2221C1211C1C21ASERVICEONP4P3P2NETWORK BUSCONTROLDISP PWRLIGHT PWRP1FUSE BLOWN5A 250V2AC2221C1211C1C21ASERVICEONP4P3P2NETWORK BUSCONTROLDISP PWRLIGHT PWRP1FUSE BLOWN5A 250V2AC2221C1211C1C21ASERVICEONP4P3P2NETWORK BUSCONTROLDISP PWRLIGHT PWRP1FUSENNDMEX9BLOWN5A 250V2AC2221C1211C1C21A SERVICE ONP4P3P2 NETWORK BUSCONTROLDISP PWRLIGHT PWRP1 FUSENDMEX4BLOWN5A 250V2AC2221C1211C1C21ASERVICEONP4P3P2NETWORK BUSCONTROLDISP PWRLIGHT PWRP1FUSENDMEX5BLOWN5A 250V2AC2221C1211C1C21ASERVICEONP4P3P2NETWORK BUSCONTROLDISP PWRLIGHT PWRP1FUSENDMEX6BLOWN5A 250V2AC2221C1211C1C21ASERVICEONP4P3P2NETWORK BUSCONTROLDISP PWRLIGHT PWRP1FUSEN DMEX8BLOWN5A 250V2AC2221C1211C1C21ASERVICE ONP4P3P2 NETWORK BUSCONTROLDISP PWRLIGHT PWRP1 FUSENDMEX7BLOWN5A 250V2AC2221C1211C1C21A SERVICE ONP4P3P2 NETWORK BUSCONTROLDISP PWRLIGHT PWRP1 FUSELOW VOLTAGE WIREWAY LOW VOLTAGE WIREWAY7"84" CS TVSS LOW VOLTAGE DISCONNECTSPUMP SHUTDOWNCONTACTORSLIGHTING CONTROLSDISPENSER CONTROLSCS TVSS PANELAPANELEPANELdPANELbPANELhPANELfPANELcPANELg2PANELg1CS TVSSCS TVSSCS TVSS CS TVSS CS TVSSCS TVSS CS TVSS CS TVSS MAIN BRK.KIRK KEYGEN BRK.KIRK KEYPNL "MDP"NEUTRAL44" WIREWAY EXTENSION36" WIREWAY EXTENSION36" WIREWAY EXTENSION24" WIREWAY EXTENSION42" WIREWAY EXTENSIONMain dist pnlSECTION '1'SECTION '2'SECTION '3'note:within the dashed area above the panelboard sectionsprovide conduit and wireway as required. conduits shallbe 2" in size and not contain more than 29 conductorsnor be longer than 23". wireways shall be provided inaccordance with "metal wireways" article per latestadopted version of the nec. maintain all requiredclearances.F.E.PETROVFCF.E.PETROVFCF.E.F.E.PETROVFCPLCCONTROLLER4"SECTION 'A'-'A'scale: 1/2" = 1'-0"SECTION 'B'-'B'scale: 1/2" = 1'-0"SECTION '4'PLAN VIEWscale: 1/2" = 1'-0"SECTION 'C'-'C'scale: 1/2" = 1'-0"1.THE SCHNEIDER ELECTRIC INTEGRATED POWER CENTER IS INSTALLED BY THE ELECTRICAL CONTRACTOR ANDFURNISHED BY THE OWNER OR AS SPECIFIED.-THIS EQUIPMENT INCLUDES ALL SQUARE D PANELBOARDS, BREAKERS, LIGHTING CONTROLS, DISPENSER AND SUBMERSIBLE PUMP CONTROLS, PILOT LIGHTS, SWITCHES, TERMINAL STRIPS, aND LOW VOLTAGE DISCONNECT DEVICES WHICH ARE PREINSTALLED AND INTERNALLY PREWIRED.- THE ENCLOSURE MATERIAL IS 1/8" ALUMINUM.- THE ENTIRE BOTTOM OF CABINET IS OPEN EXCEPT FOR A 1" FLANGE ON EACH SECTION.- THE ENTIRE TOP OF CABINET IS SOLID. HOLES CAN BE KNOCKED OUT FOR CONDUIT ENTRY EVERYWHERE EXCEPT WHERE CABINETS JOIN TOGETHER.2.THE METER CABINET, AND PULL SECTION EQUIPMENT LOCATED OUTSIDE THE BUILDING IS NOT A PART OF THE SQUARE DIPaCS SYSTEM IF APPLICABLE.3.THE SQUARE D IPaCS SYSTEM IS UL LISTED AS A COMPLETE ASSEMBLY. THE STANDARD FAULT CURRENT RATING OFTHE SYSTEM IS 65,000 AIC.4.QUESTIONS REGARDING THE OPERATION OR INSTALLATION OF THE SQUARE D IPACS SYSTEM SHOULD BE DIRECTED TOSCHNEIDER ELECTRIC - TECHNICAL SUPPORT AT 1-800-868-9662.NOTES:AS NOTEDWSP4772-R-E5E-52017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17UTILITY ROOM ELEVATIONS AND FLOOR PLAN +INDICATES SQUARE D, HANDLE PADLOCK ATTACHMENT, MODEL NUMBER, QO1PA w/ COMPATIBLE PAD LOCK FOR CIRCUIT BREAKER.++CONTRACTOR TO PROVIDE & INSTALL CONTROL CABLE FOR SCROLLING GAS PRICE SIGN. CONDUCTORS TO BE 4 CONDUCTOR/GROUND SHIELDED CABLEWITH #22 AWG CONDUCTORS. BELDEN CAT. NO. 5502FE.+++THESE CIRCUITS MUST BE SUPPLIED FROM THE SAME MAIN BUS BARS.electrical NOTE:1.MAIN CIRCUIT BREAKER AND BUSING SHALL BE FULLY RATED FOR 65,000 AIC MIN. BRANCHCIRCUIT BREAKERS SHALL BE SERIES RATED FOR 65,000 AIC.SERIES RATING SYSTEM REQUIREMENT:1.NQ SERIES PANELBOARD - 65 KAIC2.INTERNAL MAIN CIRCUIT BREAKER QG MODEL - RATED AT A MIMINUM OF 65 KAIC. NO EQUALS OR SUBSTITUTION.3.BRANCH CIRCUIT BREAKERS SHALL BE QOB SERIES WHICH INCLUDES THE FOLLOWING SUFFIXES: HID, SWD AND SWN.NO EQUALS OR SUBSTITUTIONS.4.BRANCH BREAKERS SHALL BE LIMITED TO 15-70A FOR 1-POLE QO(B), 15-30A FOR 1-POLE QO(B) WITH SUFFIXES VH,GFI, PL, AFI, CCAFI AND 2-POLE BREAKERS 15-125A FOR QOB.5.FIELDING LABELING PER NEC FOR TESTED SERIES COMBINATION SYSTEMS.CAUTION - SERIES COMBINATION SYSTEMRATED 65,000 AMPERES. IDENTIFIEDREPLACEMENT COMPONENTS REQUIRED.LABEL FROM FACTORY++++refer to electrical note below schedule.++++++++++++++++++++++++INDICATES SQUARE D, GROUND FAULT CIRCUIT INTERRUPTER TYPE CIRCUIT BREAKER.+++PANEL 'g1'PANEL 'g2'PANEL 'MDP'schedule DIRECTORYPANEL 'a'PANEL 'b'PANEL 'd'PANEL 'E'PANEL 'f'NOTE:PROVIDE A PERMANENT PLAQUE ON THE DOOR OF THE DISTRIBUTION PANELBOARDTHAT INDICATES THE SERVICE VOLTAGE, PHASE, WIRE AND MEASURED AIC RATING.++++PANEL 'c'PANEL 'H'AS NOTEDWSP4772-R-E6E-62017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 ELECTRICAL PANEL SCHEDULES wiring diagram key notes:electronic trip adjustable trip units for pickup and time delayfunctions FOR LONG-TIME, SHORT-TIME, AND INSTANTANEOUS FUNCTIONS.1factory provided and mounted arc reduction maintenanceswitch from panelboard manufacturer. provide lexan clearcover THAT IS LOCKABLE to prevent incidental operation. switchshall have two positions: one for maintenance mode and theother position for armed. provide arc flash sticker on panelfor both modes of operation. PROVIDE SWITCH WITH LOCAL STATUSINDICATOR.2PROVIDE OPERATIONAL INSTRUCTIONS FOR USE OF THE ARC REDUCTIONMAINTENANCE SWITCH. POST INSTRUCTIONS AT PANELBOARD.OPERATIONAL PROCEDURES SHALL BE PROVIDED FROM PANELBOARDMANUFACTURER.31.THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICALCODE (NEC) ADOPTED BY THE AUTHORITY HAVING JURISDICTION, THE 2012 NORTH CAROLINA ENERGY CODE ANDALL LOCAL ORDINANCES.2.THE ELECTRICAL CONTRACTOR (EC) SHALL OBTAIN AND SUPPLY TO THE OWNER A CERTIFICATE FROM THE MIDDLEDEPARTMENT INSPECTION AGENCY, OR THE LOCAL ELECTRICAL INSPECTION AGENCY, INDICATING THAT ALLELECTRICAL WORK HAS BEEN INSPECTED AND FOUND TO BE IN COMPLIANCE WITH THE NEC.3.THE ELECTRICAL SYSTEM FOR THIS BUILDING HAS BEEN DESIGNED FOR A 120/208 VOLT, THREE PHASE, FOUR WIRE,GROUNDED ELECTRICAL SERVICE.4.THE EC SHALL BE RESPONSIBLE FOR CONTACTING THE ELECTRICAL COMPANY TO ARRANGE ALL DETAILS OF THESERVICE ENTRANCE AND METERING SHALL VERIFY ALL EQUIPMENT LOCATIONS AND SPACE5.THE EC SHALL VERIFY ALL EQUIPMENT LOCATIONS AND SPACE REQUIREMENTS WITH THE OWNER, OR THE OWNER'SDESIGNATED REPRESENTATIVE, PRIOR TO THE INSTALLATION OF THE EQUIPMENT.6.THE EC SHALL VERIFY THAT THE NAMEPLATE DATA FOR THE EQUIPMENT, TO BE INSTALLED, IS IN COMPLIANCE WITHTHE DESCRIPTION SHOWN ON THE ELECTRICAL SCHEDULES.7.THESE DRAWINGS ARE GENERAL IN NATURE AND ARE NOT MEANT TO SATISFY ALL CONDITIONS WHICH MAY OCCUR.8.THE EC SHALL BE REQUIRED TO MODIFY THE INSTALLATION TO SUIT CONDITIONS OF THE SITE.9.ALL ELECTRICAL EQUIPMENT AND MATERIAL SHALL BE U.L LABELED AND LISTED.10.SEAL AROUND ALL RACEWAY PENETRATIONS OF FIRE RATED WALLS.11.ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABELED AND LISTED BY ACERTIFIED TESTING LABORATORY OR AGENCY.12.ALL SLEEVE AND LINTEL SIZES, LOCATIONS AND ELEVATIONS THAT PENETRATE FOUNDATIONS AND EXTERIOR WALLSSHALL BE COORDINATED WITH THE GENERAL CONTRACTOR.13.RACEWAYS, CABLE ASSEMBLIES, BOXES, CABINETS, AND FITTINGS SHALL BE SECURED AND SUPPORTED IN ALLASSEMBLIES AS REQUIRED IN NEC SECTION 300.11.14.LIGHT FIXTURES SHALL BE SUPPORTED INDEPENDENTLY OF SUSPENDED CEILINGS OR THE SUSPENDED CEILINGSHALL BE SUPPORTED WITHIN SIX (6) INCHES OF EACH CORNER OF FIXTURE.15.TECHNOLOGY WIRING AND COMMUNICATION WIRES AND CABLES WITHIN THE SPACE SHALL BE INSTALLED ASREQUIRED IN NEC ARTICLE 800 SUBPART V.16.ALL LOW VOLTAGE WIRING SHALL BE UL PLENUM RATED AND INSTALLED IN COMPLIANCE WITH NEC SECTION 300.22AND 760.30(B) (1).17.AIR CONDITIONING EQUIPMENT AND RELATED CIRCUIT COMPONENTS TO BE INSTALLED AS REQUIRED IN NECARTICLES 110 AND 440.18.LIGHTING, TEMPERATURE PROBES, DISHWASHER/FAN ARE CONTROLLED VIA PLC PANEL. REFER TO 'STORE PLCCONTROL SYSTEM' SHOP DRAWINGS BY ENERTECH ASSOCIATES FOR WIRING DIAGRAMS AND ADDITIONAL DETAILSAND INFORMATION.19.THE EC SHALL VERIFY WITH THE LOCAL AUTHORITY HAVING JURISDICTION, THE REQUIREMENTS FOR THE BUILDING'SFIRE ALARM SYSTEM. IF AN ADDRESSABLE SYSTEM IS REQUIRED, PROVIDE A SIMPLEX 4006 FIRE ALARMCONTROL PANEL ( FACP ) WITH ALL PERIPHERAL DEVICES, CABLING, ETC FOR A COMPLETE, CODE COMPLIANTSYSTEM. THE EC SHALL INFORM THE ENGINEER OF THE REQUIREMENT SO THE ENGINEER CAN PROVIDE WIRINGDETAILS AND EQUIPMENT LOCATIONS.20.where conduits are exposed for equipment installation, the mounting height shall be 2" from the walland 6" above the finished floor to permit cleaning.21.WORKING CLEARANCE IN FRONT OF ALL ELECTRICAL EQUIPMENT SHALL BE MAINTAINED DURING AND AFTERCONSTRUCTION; FULL WIDTH OF THE EQUIPMENT.22.THE PROJECT SHALL USE GROUND-FAULT CIRCUIT INTERRUPTERS. ALL 120 VOLT, SINGLE-PHASE, 15 AMP AND 20AMP RECEPTACLE OUTLETS ON CONSTRUCTION SITES, WHICH ARE NOT A PART OF THE PERMANENT WIRING OF THEBUILDING OR STRUCTURE AND WHICH ARE IN USE BY EMPLOYEES, SHALL HAVE APPROVED GROUND-FAULT CIRCUITINTERRUPTERS FOR PERSONNEL PROTECTION. RECEPTACLES ON A TWO-WIRE, SINGLE-PHASE PORTABLE ORVEHICLE-MOUNTED GENERATOR RATED NOT MORE THAN 5KW, WHERE THE CIRCUIT CONDUCTORS OF THEGENERATOR ARE INSULATED FROM THE GENERATOR FRAME AND ALL OTHER GROUNDED SURFACES, NEED NOT BEPROTECTED WITH GROUND-FAULT CIRCUIT INTERRUPTERS OR AN ASSURED EQUIPMENT GROUNDING CONDUCTORPROGRAM TO PROTECT EMPLOYEES AND IT SHALL ESTABLISH AND IMPLEMENT AN ASSURED EQUIPMENTGROUNDING CONDUCTOR PROGRAM FOR THE CONSTRUCTION SITES COVERING ALL CORD SETS, RECEPTACLESWHICH ARE NOT A PART OF THE PERMANENT WIRING OF THE BUILDING OR STRUCTURE, AND EQUIPMENT CONNECTEDBY CORD AND PLUG WHICH ARE AVAILABLE FOR USE.23.ALL LABELING SHALL BE PERMANENT, DURABLE AND APPROVED BY THE CODE ENFORCEMENT OFFICIAL.24.VERIFY ALL CIRCUITS LEADING TO OR THROUGH DISPENSING EQUIPMENT INCLUDING ALL ASSOCIATED POWER,COMMUNICATIONS, DATA AND VIDEO CIRCUITS AND EQUIPMENT FOR REMOTE PUMPING SYSTEMS SHALL BEPROVIDED WITH DISCONNECTING MEANS PER NEC 514.11.ELECTRICAL NOTES1.THE EC SHALL FURNISH AND INSTALL AN EMPTY, FOUR INCH, SCHEDULE 40 PVC, CONDUIT BETWEEN THECOMMUNICATION PANEL, SHOWN ON DRAWING NUMBER E-3, AND THE PHONE COMPANY SERVICE POINT.2.THE EC SHALL FURNISH AND INSTALL SCHEDULE 40 PVC CONDUITS, BETWEEN THE COMMUNICATION PANEL AND THEPHONE AND COMMUNICATION OUTLETS SHOWN ON DRAWINGS NUMBER E-1 AND E-3.1.ALL OUTSIDE LIGHTING WILL BE CONTROLLED BY THE PLC CONTROLLER SUPPLIED BY SHEETZ. THE GASOLINECONTRACTOR WILL INSTALL THE PLC. THE EC WILL BE RESPONSIBLE FOR TERMINATING ALL LINE AND LOAD POWERTO THE PLC CONTACTORS FOR THE AREA, FLAG POLE, SIGN, AND EXTERIOR BUILDING LIGHTS. THE EC WILL ALSOBE RESPONSIBLE FOR POWER CIRCUIT TO PLC AND CONTROL CIRCUIT FOR PHOTO CELL. THE GASOLINECONTRACTOR WILL BE RESPONSIBLE FOR LINE AND LOAD POWER TO PLC CONTACTORS FOR AWNING AND CANOPYDOWN LIGHTING.2.THE NUMBER AND SIZE OF THE CONDUITS REQUIRED SHALL BE VERIFIED WITH THE OWNER, OR THE OWNER'SREPRESENTATIVE, BEFORE THE CONDUITS ARE INSTALLED.3.AFTER THE INSTALLATION HAS BEEN COMPLETED, THE REQUIRED SEAL OFF FITTINGS, BOTH OUTSIDE AND INSIDE THEBUILDING SHALL BE FILLED WITH AN APPROVED TYPE OF SEALING COMPOUND.4.THE EC SHALL CONNECT ALL EXTERIOR LIGHTING INCLUDING, BUT NOT LIMITED TO, AREA LIGHTS, FLAG POLE LIGHT,SIGNS, AND EXTERIOR BUILDING SIGNS, BUILDING FLOOD LIGHTS AND OUTSIDE FLUORESCENT LIGHTS TOGETHERTHROUGH CONTACTORS AND CONNECT TO PLC AS REQUIRED. THE PHOTO CELL IS TO BE PLACED IN A PROTECTEDAREA AWAY FROM CAR HEADLIGHTS AND OTHER OUTSIDE LIGHTS.5.ALL BRANCH CIRCUITS SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH TABLE 250.122 OF THE LATESTADOPTED EDITION OF THE NEC. THE CONTINUITY OF THE GROUNDING SYSTEM SHALL BE INSURED THROUGH THE USEOF PROPERLY SIZED COPPER EQUIPMENT GROUNDING CONDUCTORS WHICH SHALL BE INSTALLED WITHIN THECONDUITS.1.AREA LIGHTS: THE EC WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLING CONDUITS WITH APPROVED SEAL OFFFITTINGS, AND WIRING, 208 VOLTS USING #10 AWG WIRE (SUITABLE FOR WET LOCATIONS) CONTROLLED BY PLCCONTROLLER. EACH POLE WILL COME WITH A RECEPTACLE THAT NEEDS A 20 AMP, 120 VOLT CIRCUIT. SEE NECARTICLE 514.2.FLAG POLE LIGHT: THE EC WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ONE 3/4" CONDUIT WITHAPPROVED SEAL OFF FITTING, AND WIRING FOR FLAG POLE LIGHT, 20 AMP, 120 VOLT CIRCUIT PLUS TWO SPARECONDUCTORS, USING #10 AWG WIRE (SUITABLE FOR WET LOCATIONS). SEE NEC ARTICLE 5143.SIGNS: THE EC WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLING RMC CONDUITS WITH APPROVED SEAL OFFFITTINGS AND WIRING, #10 AWG (SUITABLE FOR WET LOCATIONS), AS FOLLOWS. ONE 1" HIGH VOLTAGE CONDUIT WITHTHREE, 20 AMP, 120 VOLT CIRCUITS CONTROLLED BY PLC AND TWO, 20 AMP, 120 VOLT CIRCUITS, ONE EACH FORSIGN CONTROLLER RECEPTACLE AND SERVICE RECEPTACLE PLUS TWO SPARE CONDUCTORS. ONE 1" LOWVOLTAGE CONDUIT WITH SIGN CONTROL CABLE (SUPPLIED BY SHEETZ). SEE NEC ARTICLE 514.4.EXTERIOR BUILDING LIGHTS: THE EC WILL BE RESPONSIBLE FOR INSTALLING LIGHT FXTURES, AND FURNISHING ANDINSTALLING WIRING TO FIXTURES. FIXTURES TO BE CONTROLLED BY PLC.1.THE EC WILL BE RESPONSIBLE TO FURNISH AND INSTALL RMC CONDUITS WITH APPROVED SEAL OFF FITTINGS, FORTHE GASOLINE INSTALLATION TO A POINT 5' PAST EDGE OF FRONT SIDE WALK. AT WHICH POINT THE GASOLINECONTRACTOR SHALL TAKE THE CONDUITS HE NEEDS TO TERMINATION. SEE NEC ARTICLE 514. vertical styleseal-offs shall be used. allow minimum 6" between top of seal-off and bottom of trough.2.ALL BRANCH CIRCUITS SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH TABLE 250.122 OF THE LATESTADOPTED EDITION OF THE NEC. THE CONTINUITY OF THE GROUNDING SYSTEM SHALL BE INSURED THROUGH THE USEOF PROPERLY SIZED COPPER EQUIPMENT GROUNDING CONDUCTORS WHICH SHALL BE INSTALLED WITHIN THECONDUITS.1.THE EC SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL ELECTRICAL EQUIPMENT AND ALL BRANCH CIRCUITCONDUCTORS AS INDICATED IN DRAWINGS E-1 AND E-3.2.THE BRANCH CIRCUIT CONDUCTORS SHALL BE COPPER WITH TYPE THHN/THWN-2 INSULATION AND SHALL BEINSTALLED IN EMT CONDUIT. AND SCHEDULE 40 PVC UNDER- GROUND CONDUIT. BRANCH CIRCUIT CONNECTIONS,BETWEEN JUNCTION BOXES AND INDIVIDUAL LIGHT FIXTURES AND OTHER EQUIPMENT CAN BE MADE USING TYPE MCCABLE.NOTE: TYPE NM (ROMEX) CABLE SHALL NOT BE PERMITTED.3.THE BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH THE CURRENT RATING OF THE BRANCHCIRCUIT PROTECTIVE DEVICE. ALL BRANCH CIRCUIT CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITHARTICLE B.5 ABOVE.4.ALL BRANCH CIRCUITS SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH TABLE 250.122 OF THE LATESTADOPTED EDITION OF THE NEC. THE CONTINUITY OF THE GROUNDING SYSTEM SHALL BE INSURED THROUGH THE USEOF PROPERLY SIZED COPPER EQUIPMENT GROUNDING CONDUCTORS WHICH SHALL BE INSTALLED WITHIN THECONDUITS.1.THE EC SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL OF THE FEEDER CIRCUITS BETWEEN THE MAINDISTRIBUTION PANELBOARD AND ALL OF THE PANELBOARDS AND OTHER EQUIPMENT AS SHOWN ON THE RISERDIAGRAM ON this DRAWING below.2.THE FEEDER CIRCUIT CONDUCTORS SHALL BE COPPER WITH TYPE THHN/THWN-2 INSULATION AND SHALL BEINSTALLED IN ELECTRICAL METALLIC TUBING (EMT). THE CONDUCTORS SHALL BE SIZED AS INDICATED ON thisDRAWING below. ALL FEEDER CIRCUIT CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH ARTICLE B.5ABOVE.3.THE FEEDER CIRCUITS WHICH ARE INSTALLED UNDER THE FLOOR OR UNDERGROUND SHALL BE INSTALLED INSCHEDULE 40 PVC CONDUITS, UNLESS NOTED OTHERWISE4.ALL FEEDER CIRCUITS SHALL BE PROPERLY GROUNDED IN ACCORDANCE WITH TABLE 250.122 OF THE LATESTADOPTED EDITION OF THE NEC. THE CONTINUITY OF THE GROUNDING SYSTEM SHALL BE INSURED THROUGH THE USEOF PROPERLY SIZED COPPER EQUIPMENT GROUNDING CONDUCTORS WHICH SHALL BE INSTALLED WITHIN THECONDUITS.A. GENERAL:B. ELECTRICAL SERVICE:D. FEEDER CIRCUITS:E. BRANCH CIRCUITS:F. COOLERS, FREEZERS AND HVAC EQUIPMENT:J. OUTSIDE LIGHTING CONTROL:I. AREA, FLAG POLE, SIGN, AND EXTERIOR BUILDING LIGHTING:H. SELF SERVE GAS PUMP AREA, CANOPY, AND AWNING LIGHTS:G. TELEPHONE AND COMMUNICATION SYSTEM:C. COORDINATION STUDY1.THE EC SHALL PROVIDE THE TRENCHING, CONDUIT AND BACK-FILLING REQUIRED FOR THE INSTALLATION OF THEELECTRICAL SERVICE ENTRANCE CONDUCTORS BETWEEN THE NEW BUILDING AND THE ELECTRICAL POWERCOMPANY'S SERVICE POLE. (THIS WILL ONLY APPLY ON GENERAL CONTRACTOR SITES)2.THE SERVICE ENTRANCE CONDUCTORS SHALL BE COPPER WITH TYPE THHN/THWN-2 INSULATION AND SHALL BEINSTALLED IN SCHEDULE 40 PVC CONDUITS, WHERE INSTALLED UNDERGROUND, AND IN RIGID GALVANIZED STEELCONDUITS WHERE EXPOSED. WHERE REQUIRED, THE UNDERGROUND RIGID METALLIC CONDUITS SHALL BE COVEREDWITH NOT LESS THAN 24" OF COVER FROM TOP OF CONDUIT TO FINISHED GRADE. THE CONDUCTORS SHALL BE SIZEDAS INDICATED ON THE RISER DIAGRAM ON THIS DRAWING.3.THE EC SHALL BE RESPONSIBLE FOR THE INSTALLATION OF THE POWER COMPANY CURRENT TRANSFORMER ANDMETERING EQUIPMENT, AND ALSO FOR THE INSTALLATION OF THE BUILDING MAIN DISTRIBUTION PANELBOARD ANDPANELBOARDS REQUIRED FOR THE ELECTRICAL SYSTEM, AS SHOWN ON THE RISER DIAGRAM ON THIS DRAWING.4.THE ELECTRICAL SERVICE SHALL BE GROUNDED IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC. THISGROUNDING IS TO INCLUDE THE BUILDING STEEL FRAME, THE METAL WATER PIPING SYSTEM, CONCRETE ENCASEDELECTRODE (UFER GROUND) AND TWO (2) DRIVEN GROUND RODS MINIMUM. GROUND RODS SHALL BE 3/4" INDIAMETER BY 10'-0" IN LENGTH AND BE COPPER-CLAD STEEL W/ HIGH-STRENGTH STEEL CORE &ELECTROLYTIC-GRADE COPPER OUTER SHEATH, MOLTEN WELDED TO CORE.5.THE CONDUCTORS FOR THE SERVICE ENTRANCE, ALL FEEDER CIRCUITS AND ALL BRANCH CIRCUITS SHALL BECOLOR CODED, USING EITHER APPROVED MARKING TAPE OR COLORED INSULATION, AS INDICATED BELOW:PHASE 'A' = BLACKPHASE 'B' = REDPHASE 'C' = BLUENEUTRAL = WHITEGROUNDING = GREEN OR BARENOTE: GROUNDING CONDUCTORS FOR ISOLATED GROUND TYPE RECEPTACLES MUST BE INSULATED AND IDENTIFIED WITHGREEN INSULATION AND YELLOW MARKING TAPE.6.PROVIDE BONDING IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NEC. THIS BONDING SHALLINCLUDE METAL WATER PIPING, OTHER METAL PIPING INCLUDING GAS PIPING, EXPOSED STRUCTURAL METAL ANDMETAL DUCTWORK.1.THE EC SHALL BE RESPONSIBLE FOR ALL ELECTRICAL WORK REQUIRED FOR THE INSTALLATION OF THE HVACEQUIPMENT INCLUDING THE DISCONNECT SWITCHES AND FUSES REQUIRED FOR THE ROOF MOUNTED UNITS. THESE UNITSARE SHOWN ON DRAWINGS NUMBERED MEP-1 & E-3. SEE NEC ARTICLE 300.7.2.THE EC SHALL SEAL ALL RACEWAYS SUBJECTED TO DIFFERENT TEMPERATURES SUCH AS WALK-IN COOLERS ANDFREEZERS, OR WHEN PASSING FROM THE INTERIOR TO THE EXTERIOR OF THE BUILDING, SHALL BE FILLED WITH ANAPPROVED SEALANT MATERIAL (FST DUCT SEALANT SYSTEM FROM AMERICAN POLYWATER OR AN APPROVEDEQUIVALENT BY THE ENGINEER) TO PREVENT THE CIRCULATION OF WARM AIR TO A COOLER SECTION OF THERACEWAY.1.PROVIDE A COMPUTER BASED ELECTRICAL SHORT CIRCUIT (FAULT-CURRENT) STUDY, OVERCURRENT PROTECTIVEDEVICE COORDINATION STUDY, AND AN ARC-FLASH HAZARD STUDY FOR THE BUILDING ELECTRICAL SYSTEM. THESCOPE OF THE STUDIES SHALL INCLUDE ALL NEW DISTRIBUTION EQUIPMENT SUPPLIED UNDER THIS CONTRACT BY ANYAND ALL MANUFACTURERS AS WELL AS ALL EXISTING DISTRIBUTION EQUIPMENT AT THE CUSTOMER FACILITY.2.THE ELECTRICAL SYSTEM PROTECTIVE DEVICE STUDY REQUIRED BY THIS SECTION SHALL BE PREPARED BY APROFESSIONAL ELECTRICAL ENGINEER SKILLED IN PERFORMING AND INTERPRETING THE POWER SYSTEMS STUDIESAND REGISTERED IN THE STATE IN WHICH THE PROJECT IS BEING CONSTRUCTED. THE REGISTERED PROFESSIONALELECTRICAL ENGINEER SHALL HAVE A MINIMUM OF FIVE (5) YEARS OF EXPERIENCE IN PERFORMING POWER SYSTEMSTUDIES. ALL STUDIES SHALL BE PREPARED BY THE SAME PROFESSIONAL ENGINEER.3.THIS CONTRACTOR AND ASSOCIATED MANUFACTURERS SHALL BE REQUIRED TO COOPERATE WITH THE STUDYPROFESSIONAL AND ANY OTHER ELECTRICAL CONTRACTORS AND SHALL PROVIDE ALL NECESSARY INFORMATION,CURVES, AND DATA FOR ALL EQUIPMENT.4.THE STUDY PROFESSIONAL SHALL SUBMIT THE FINAL STUDY TO OWNER FOR REVIEW AND APPROVAL.5.A TABULATION OF ALL RECOMMENDED RELAY SETTINGS AND CIRCUIT BREAKER TRIP SETTINGS SHALL BEPROVIDED TO THE CONTRACTOR BY THE STUDY PROFESSIONAL. THE CONTRACTOR SHALL FIELD SET ALL RELAYSAND CIRCUIT BREAKER TRIP SETTINGS IN THE FIELD PER THE FINAL APPROVED STUDY.6.THE FINAL SELECTION OF OVERCURRENT DEVICES WILL BE BASED ON THIS COORDINATION STUDY.7.A TABULATION OF ALL ARC FLASH LABELS SHALL BE PROVIDED TO THE CONTRACTOR BY THE STUDYPROFESSIONAL. THE CONTRACTOR SHALL PRINT AND FIELD APPLY ALL ARC FLASH LABELS INCLUDING LEVEL 0EQUIPMENT.NO SCALERISER DIAGRAMELECTRIC POWERCOMPANY METERELECTRIC POWER COMPANYCURRENT TRANSFORMER(S)(4) RUNS (4-350MCM(CU) IN 4" PVC CONDUITSUNDERGROUND, AND 4" RGS CONDUITS WHEREEXPOSED) ALL CONDUCTORS TO HAVE TYPE(THHN/THWN-2) 90 C INSULATION.ELECTRIC POWER COMPANYOVERHEAD SERVICE DROP208Y/120V, 3Ph, 4W1.THE ELECTRICAL SERVICE EQUIPMENT FOR THIS PROJECT SHALL BE DESIGNEDFOR AN AVAILABLE FAULT CURRENT OF 65,000 AMPERES RMS.2.ALL PANELBOARDS SUPPLIED BY A FEEDER CONDUCTOR SHALL BE MARKED(LABELED) TO INDICATE WHERE THE POWER SUPPLY FOR THE PANELBOARDORIGINATES FROM IN ACCORDANCE WITH THE NEC 408.4(B).3.POST AVAILABLE FAULT CURRENT RATINGS SHALL BE FIELD MARKED ON THEELECTRICAL SERVICE EQUIPMENT IN THE FIELD PER NEC 110.24(A).NOTES:1200A/3PTYPE PGFULLYRATED(4) #4/0 & (1) #4 GRD - 212" C.(3) #4/0 & (1) #4 GRD - 2" C.1234(4) #500MCM & (1) #3 GRD - 3" C.5(4) #10 & (1) #10 GRD - 34" C.6FEEDER SCHEDULE(3) #6 & (1) #10 GRD - 34" C.(3) #2 & (1) #8 GRD - 114" C.90A/3PTYPE FH1200A BUSMAIN DISTRIBUTION PANEL 'MDP' (service entrance rated)208Y/120V, 3Ph, 4W, 60HzHVAC AC-2 UNITON ROOFSELF-CONTAINEDDISCONNECTHVAC AC-3 UNITON ROOFSELF-CONTAINEDDISCONNECT112SURGEPROTECTIVEDEVICECATALOG No.ORN-3Y-120/208VPlus 4 WIRE & GRD650A/3PTYPE FH50A/3PTYPE FH30A/3PTYPE FHSPACE w/PROVISIONSSPACE w/PROVISIONSSPACE w/PROVISIONSSPACE w/PROVISIONSSPACE w/PROVISIONS400A/3PTYPE LA5KIKIPANELBOARDGROUND BAR#3/0 (CU) GROUNDINGELECTRODE CONDUCTORCONCRETEENCASEDGROUNDINGELECTRODEOR REBARBLDGSTEELGROUND RODS: 3/4"∅ x 10'-0"L COPPER-CLADSTEEL W/ HIGH-STRENGTH STEEL CORE &ELECTROLYTIC-GRADE COPPER OUTER SHEATH,MOLTEN WELDED TO CORE#3/0 (CU)JUMPERWATERMETERWATERMAINFLOW 10'-0" MIN.#3/0 (CU) GROUNDINGELECTRODE CONDUCTORNO SPLICES FROMPANEL TO LAST RODGGENERATOR CABLESBY OTHERS400A-3P-NF, 240V, NEMA 3R,HEAVY-DUTY DISCONNECTSWITCH MTD ON EXTERIOR WALLNEXT TO CT CABINETWPPORTABLE110 kW TO 150 kWGENERATOR FOROPTIONAL STANDBYSYSTEMBY OTHERSHVAC AC-1 UNITON ROOFSELF-CONTAINEDDISCONNECTPANEL'B'3∅-4W120/208Vmilo 225a PANEL'g2'3∅-4W120/208Vmilo 225a PANEL'D'3∅-4W120/208Vmilo 225aPANEL'A'3∅-4W120/208Vmilo 225a PANEL'F'3∅-4W120/208Vmilo 225aPANEL'c'3∅-4W120/208Vmilo 225aPANEL'E'3∅-4W120/208Vmilo 225a PANEL'H'3∅-4W120/208Vmilo 225a 43225A/3PTYPE QG225A/2PTYPE QG225A/3PTYPE QG225A/3PTYPE QG444225A/3PTYPE QGsection 1section 2section 34225A/3PTYPE QG4225A/3PTYPE QG225A/3PTYPE QG225A/3PTYPE QG44225A/3PTYPE QGPANEL'g1'1∅-3W120/208Vmcb 225af 225at LIGHTINGCONTROLSDISPENSERCONTROLSLOWVOLTAGEDISCONNECTSPUMPSHUTDOWNCONTACTORSsection 465,000 AIC RATINGSPAreKIRK KEY INTERLOCK w/MAIN SERVICE BREAKERKILEGEND12SKSKARC REDUCTION MAINTENANCE SWITCHLONG-TIME ADJUSTMENT - PICKUP AND DELAYLS3SHORT-TIME ADJUSTMENT - PICKUP AND DELAYIINSTANTANEOUS ADJUSTMENT - PICKUPAS NOTEDWSP4772-R-E7E-7GENERAL NOTES RISER DIAGRAM & LOAD TABLE 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 SCALE : 1/2" = 1'-0'BACK WALL PRODUCTION LINE ELEVATIONC-1,3,5C-2,4,6B-18C/D54" AFFTO STORESERVER18" AFF4.374.37C/D48" AFF66" AFFC-9D-4C-32C-30E-118" AFFTO STORESERVER48" AFF4.354.6210.50C/D66" AFFE-1C-2610.50TO STORESERVERD-16D-12D-13,1518" AFF48" AFF48" AFFD-148.923.133.193.13GFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFI72" AFFC-16B-30C-21,23C/D4.133.214.3618" AFF48" AFFTO STORESERVERGFIGFI3.15TO STORESERVERC/D66" AFFE-110.50GFILABEL MINDER,120V-1∅BOTTOM OF SOFFIT HEIGHT = 7'-6"CEILING HEIGHT = 8'-0"CEILING HEIGHT = 11'-0"INSIDECORNEROF WALLVIEWED ON ANGLE12'-10 1/2"DISHWASHING LINE PLANSCALE : 1/2" = 1'-0'7.505.15A5.015.11trashTRASHDISHWASHING LINE ELEVATIONSSDISCONNECT ONMAKE-UP AIR FANMAKE-UP AIR FANON ROOFDISCONNECT ONEXH. FANEXHAUST FANON ROOFCONTROL PANEL FORMAKE-UP AIR AND EXH.FANS ON ROOF. MOUNT BTMOF CNTRL PNL @ 7'-0" AFFCONTROL PANEL FORTURBO CHEF EXHAUST FANON ROOF. MOUNT BTM OFCNTRL PNL @ 7'-0" AFFTO TURBO CHEFEXHAUST FAN ON ROOFC-22,24B-9,11,13C-29B-23DISHMACHINEHOT WATERBOOSTER PUMPSMCEILINGFLOORSCALE : 1/2" = 1'-0'C-12,14C-105.01a5.01b5.15A5.015.117.50C-28C-34DISHMACHINE SINGLE PHASE DISC SW w/THERMAL OVERLOADS SHOWN HEREDIAGRAMMATICALLY, MTD @ 48" AFF ONADJACENT WALL NEXT TO BOOSTER PUMPDISCONNECT. REFER TO SHEET E-3 FORAPPROXIMATE LOCATION. COORDINATEWITH OWNER'S FIELD REPRESENTATIVE FOREXACT LOCATION WHILE MAINTAININGMINIMUM NEC CLEARANCES.DISHMACHINE HOT WATER BOOSTER PUMPDISC SW IN NEMA 4 ENCLOSURE SHOWN HEREDIAGRAMMATICALLY, MTD @ 48" AFF ONADJACENT WALL NEXT TO DISHMACHINESINGLE PHASE SWITCH DISCONNECT. REFERTO SHEET E-3 FOR APPROXIMATE LOCATION.COORDINATE WITH OWNER'S FIELDREPRESENTATIVE FOR EXACT LOCATIONMAINTAINING MINIMUM NEC CLEARANCES.PROVIDE MINIMUM OF 48" OF ADDITIONALCONDUCTORS AT REAR OF UNIT TO PERMITMAINTENANCE OF EQUIPMENT.AS NOTEDWSP4772-R-E8E-8 ELECTRICAL DETAILS 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17 FRONT FOOD PRODUCTION LINESCALE : 1/2" = 1'-0"( CLERK SIDE OF ORDER POINT WALL )7.5"13"24"A4'-0"TANKMONITOR6"ASECTION "A-A"5'-0" 6'-7" 6'-7" 5'-0"NOTES:1.CONDUIT TO TANK MONITOR TROUGH TO BE INSTALLED SUCH THAT ASYOU FACE THE MONITOR, THE L.V. SHOULD BE ON THE RIGHT AND THEH.V. SHOULD BE INSTALLED ON THE LEFT.2.2" CONDUITS FROM LOW VOLTAGE TROUGH IN PANEL ROOM TO TANKMONITOR TROUGH IN MANAGERS OFFICE ARE TO BE RUN WITH RMCFOR THE ENTIRE LENGTH4" MIN.PHONE JACK LOCATED DOORSIDE OF TANK MONITOR ANDTO CLOSEST STUDTWO 12"x12"x9" TROUGHS(RECESSED IN WALL)TWO 12"x12"x9" TROUGHS(RECESSED IN WALL)(2) 2" L.V. CONDUITS2" RIGID METALCONDUIT (TYP.)2" H.V. CONDUITTANKMONITORPANEL G1-12terminate 114" c. with insulated typebushing above accessible type ceiling inelectrical room. coordinate terminationlocation in field with sheetz personnel.RECEPTACLE ON ROOF DETAILNO SCALEEXIT SIGNNO SCALETANK MONITOR DETAILNO SCALE1.EXIT SIGNS AND THE EMERGENCY MEANS OF EGRESS LIGHTING SHALL PROVIDEAN EMERGENCY POWER DURATION OF AT LEAST 90 MIN. IN ACCORDANCE WITHIBC1006.3 & NEC700.12(f).2.THE POWER SOURCE SHALL BE CONNECTED TO AN EMERGENCY ELECTRICALSYSTEM IN ACCORDANCE WITH ARTICLE 700 OF NFPA 70. (1023.0, 1024.0 &2706.0)6" RED LETTERSNOTEs:J-BOXTRUSS (TYPICAL)ROOF SYSTEMPIPE SUPPORT STRAP TYPE(TYPICAL AS NEEDED)BOOT TO FLASHING(MAINTAIN WATERTIGHTROOF SYSTEM)3/4" RIGIDELECTRICAL CONDUITWEATHER PROOF BOX WITHTA MACK TYPE COVERSDOWN TO TURBO CHEFEXHAUST FAN CONTROLPANEL.5.15.75"EXITPARTITION WALL - UNDERFLOOR CONDUITSD-39 = (2) #10 & (1) #10 GRD (24A)E-5 = (2) #12 & (1) #12 GRDE-5 = (2) #12 & (1) #12 GRDE-1 = (2) #12 & (1) #12 GRDD-34,36 = (2) #10 & (1) #10 GRD (28.8A)D-9,11 = (2) #10 & (1) #10 GRD (28.8A)C-11 = (2) #12 & (1) #12 GRD (6A)C-25,27 = (2) #10 & (1) #12 GRD (11.5A)C-20 = (2) #12 & (1) #12 GRD (9.6A)C-17,19 = (2) #12 & (1) #12 GRD (14A)C-13,15 = (2) #12 & (1) #12 GRD (14A)C-18 = (2) #12 & (1) #12 GRD (9.6A)D-34,36 = (2) #10 & (1) #10 GRD (28.8A)D-9,11 = (2) #10 & (1) #10 GRD (28.8A)C-25,27 = (2) #10 & (1) #12 GRD (11.5A)C-11 = (2) #12 & (1) #12 GRD (6A)C-20 = (2) #12 & (1) #12 GRD (6.5A)C-17,19 = (2) #12 & (1) #12 GRD (14A)C-13,15 = (2) #12 & (1) #12 GRD (14A)C-18 = (2) #12 & (1) #12 GRD (6.5A)D-2 = (2) #12 + (1) #12 GRD (6.25A)CONDUIT #1 - 1" PVCCONDUIT #2 - 1" PVCCONDUIT #3 - 1" PVCCONDUIT #4 - 1" PVCCONDUIT #5 - 1" PVCCONDUIT #9 - 1" PVCCONDUIT #10 - 1" PVCCONDUIT #11 - 1" PVCCONDUIT #12 - 1" PVCE-1 = (2) #12 & (1) #12 GRDELECTRICAL CIRCUITSCONDUIT #6 - 1" PVCSPARE WITH NYLON PULL CORDD-39 = (2) #10 & (1) #10 GRD (24A)D-2 = (2) #12 + (1) #12 GRD (6.25A)·FOUR (4) TOUCH SCREEN CABLES·THREE (3) ORDER MONITOR CABLES·THREE (3) DISPLAY MONITOR CABLESCOMMUNICATION AND DATA CABLESCONDUIT #7 - 1 1/4" PVCCONDUIT #8 - 1 1/4" PVCSPARE WITH NYLON PULL CORDSPARE WITH NYLON PULL CORDFOR COMMUNICATIONS & DATA CABLESWITH NYLON PULL CORDFOR COMMUNICATIONS & DATA CABLESWITH NYLON PULL CORD5.15NOTE:1.ALL DUPLEX RECEPTACLES ON THE FRONT FOOD PRODUCTIONLINE SHALL BE GROUND FAULT INTERRUPTER TYPE RECEPTACLES.TO PLCC/D60" AFF48" AFF60" AFF18" AFFC-18D-2C-11C-20C-17,19D-34,36C-25,27C-13,15D-9,116.1418" AFF18" AFF4.136.146.136.156.104.144.144.13GFIGFIGFIGFICONDUITS #7 & #8 TO STORE SERVER FORCOMMUNICATIONS AND DATA CABLES. two (2)114" PVC CONDUITS UNDER FLOOR AND STUBBEDUP IN HALF WALL.. SEE PARTITION WALL -UNDERFLOOR CONDUITS DETAIL THIS DRAWING.CONDUITS #1, #2, #3, #4, #5 & #6 TO PANELBOARDS.SIX (6) 1" PVC CONDUITS, UNDER FLOOR ANDSTUBBED UP IN HALF WALL. SEE PARITION WALL -UNDERFLOOR CONDUITS DETAIL THIS DRAWING.CONDUITS #9, #10, #11 & #12 TO PANELBOARDS.FOUR(4) 1" PVC CONDUITS, UNDER FLOOR. SEEPARITION WALL - UNDERFLOOR CONDUITSDETAIL THIS DRAWING.F-6,8F-5,730" AFF8.318.31F-1,3F-2,430" AFF8.318.31C/DE-1C/DE-1toSTORESERVERtoSTORESERVER10.5010.5060" AFFC/DC/DC/D(2) #12 + (1) #12 GRD TYPE MC CABLEC/DMTD INSIDE WALLFACING SALESAREA (TYPICAL)C/DC/DC/D39" AFF10.6010.6010.6010.60e-5e-4DIGITALSIGNAGE5.15digital signageby ownerF-6,8 = (3) #6 (1) #10 GRD (32.7A)F-5,7 = (3) #6 (1) #10 GRD (32.7A)F-2,4 = (3) #6 (1) #10 GRD (32.7A)F-1,3 = (3) #6 (1) #10 GRD (32.7A)F-2,4 = (3) #6 (1) #10 GRD (32.7A)F-1,3 = (3) #6 (1) #10 GRD (32.7A)F-6,8 = (3) #6 (1) #10 GRD (32.7A)F-5,7 = (3) #6 (1) #10 GRD (32.7A)E-4 = (2) #12 & (1) #12 GRDE-4 = (2) #12 & (1) #12 GRDF-128.32GFIC/DtoSTORESERVERE-110.50GFIMTD INSIDE WALLFACING SALESAREA (TYPICAL)C/DC/DD-39D-41TOPLCTOPLC8" AFF8" AFF8.678.67R.T.E.(INSTALLED IN FIELD)R.T.E.(INSTALLED IN FIELD)digital signageby ownerPLC PROBE LOCATIONS1.TAKE HOME COOLER2.WALK-IN COOLER3.WALK-IN FREEZER4.WALK-IN TAKE HOME COOLER5.RTE CASE6.RETURN AIR KITCHEN7.RETURN AIR SALES AREA8.RETURN AIR BACK ROOMF-12 = (2) #12 (1) #12 GRD (11A)F-12 = (2) #12 (1) #12 GRD (11A)D-41 = (2) #10 & (1) #10 GRD (24A)D-41 = (2) #10 & (1) #10 GRD (24A)KITCHEN CEILING HEIGHT = 11'-0"CHECKSTANDSWINGDOORCEILING HEIGHT = 11'-0"CEILING HEIGHT = 8'-0" (BEYOND)BOTTOM OF SOFFIT HEIGHT = 7'-6" (BEYOND)SELF-SERVE COFFEEFRONT FOOD PRODUCTION LINEORDER POINT WALL ATSCALE : 1/2" = 1'-0"AS NOTEDWSP4772-R-E9E-9 ELECTRICAL DETAILS 2017-0594X0112-22-17BID SETBY REVISIONS DESCRIPTIONDATESCALE:FILENAME:DATE:DRAWN BY:Convenience Architecture and Design P.C. 351 Sheetz Way, Claysburg, PA 16625 (814)239-6013 BID SET12-22-17 NEW SHEETZ STORE "LILLINGTON" 55 PINE STATE STREET LILLINGTON, NC 27546 HARNETT COUNTY NO R TH CAROLINAPR O FESSIONALENGINEERDAVID J. ANDER SON SEAL04300512-21-17