Loading...
CO INSPECTION t COUNTY OF HARNETT Building Inspections 0 Department . Planning Services X 11 Certificate of Compliance: Occupancy: 4 Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances. This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the aj.=z North Carolina State Building Codes. For the following ,s Use Classification: j2.P S t cI '.J\ ` t �1� Permit Numbers IIII Name: 1j a ‘k o✓tti (Lobo } t'7 ._1 Building: _ Electrical: ,�� Address: t F-�n� �F f�rtieF NL Insulation: � 4 p�� �' z 7571 I Plumbing: P'a. Mechanical: \z\' _ �' 4 MFG Home: _. Date: 2 —i - I -7 Building Official: %�� �_. s PREPARED 1:///30/17, 14:13 :03 INSPECTION TICKET PAGE 16 Harnett C030ty INSPECTOR: IVR DATE 12/01/17 ADDRESS . : 89 EATON DR SUBDIV: OXFORD WOODS PH 2 15LOTS CONTRACTOR : HELLOES ROBERT PAUL (REALTY) PHONE : (910) 892-3123 OWNER : PRINCE JAMES ROBERT PHONE : (919) 639-3246 PARCEL . . : 04-0692- - -0017- -39- APPL NUMBER: 17-50041457 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 05/23/2017 10:52 AM LBENNETT -- OLD STAGE RD - GO ABOUT 2 MILES - OXFORD WOODS ON LEFT - TURN IN AND GO TO FIRST STREET ON THE RIGHT & TURN ONTO EATON DR - LOT ON LEFT APPL NOTES : BPMN 7/06/17 T/S: 07/06/2017 09 :53 AM BPETRICH -- **+* PREMISE 87973435 **** CALLED IN TEMP SERVICE 7/6 BP STRUCTURE: 000 000 60X48 3BDR W/GARAGE W/DECK CRAWL FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8101 01 7/05/17 DT R*BLDG FOOTING / TEMP SVC POLE VRU #: 002992741 7/05/17 AP T/S: 07/05/2017 11:16 AM DETAYLOR A814 01 7/05/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002992758 7/03/17 AP 89 EATON DR ANGIER 27501 T/S: 07/03/2017 10:00 AM SBENNETT B103 01 7/21/17 DT R*BLDG FOUND & TEMP SVC POLE VRU #: 003000551 7/21/17 AP T/S: 07/21/2017 03 :47 PM DETAYLOR B104 01 7/26/17 BP R*FOUND & SETBACK VERIF SURVEY TIME: 17:00 VRU #: 003004520 7/26/17 AP T/S: 07/26/2017 02 :25 PM BPETRICH T/S: 07/26/2017 02 :26 PM BPETRICH B105 01 7/28/17 DT R*OPEN FLOOR VRU #: 003004900 7/28/17 AP T/S: 07/28/2017 11:58 AM DETAYLOR R425 01 9/07/17 JLP FOUR TRADE ROUGH IN VRU #: 003021409 9/07/17 DA 1-Missing nuts on anchor bolts in garage. 2-Missing air barrier under stairs and in vaulted ceiling in living room. 3-Missing nails in nailguard at panel. 4-Fireblock chase for ductwork. 5-Replace all short nails in hangers with correct size nails. 6-Missing nails in hurricane clip in front right bedroom. 7- Install and seal air barrier properly in bonus room. 8-attach loose house wrap. R425 02 9/13/17 JLP FOUR TRADE ROUGH IN VRU #: 003023579 9/13/17 DA 1-Replace all short nails in hangers with correct size nails. 2-Vaulted ceilings in living room needs air barrier. 3-structural nail guard at panel needs to be moved. OK TO SIDE AND INSULATE I129 01 9/18/17 DT R*INSULATION INSPECTION VRU #: 003025426 9/19/17 AP T/S: 09/19/2017 08:09 AM DETAYLOR R425 03 9/18/17 DT FOUR TRADE ROUGH IN VRU #: 003025418 9/19/17 AP T/S: 09/19/2017 08:09 AM DETAYLOR H824 01 11/01/17 AC ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003048592 11/01/17 AP T/S: 11/02/2017 10:41 AM KHINSON T/S: 11/02/2017 10:41 AM KHINSON R429 01 11/30/17 DT FOUR TRADE FINAL VRU #: 003059458 CONTINUED ONTO NEXT PAGE PREPARE 11/30/17, 14:13 :03 INSPECTION TICKET PAGE 17 Hdmeft County INSPECTOR: IVR DATE 12/01/17 ADDRESS . : 89 EATON DR SUBDIV: OXFORD WOODS PH 2 15LOTS CONTRACTOR : HELLOES ROBERT PAUL (REALTY) PHONE : (910) 892-3123 OWNER . . : PRINCE JAMES ROBERT PHONE : (919) 639-3246 PARCEL . . : 04-0692- - -0017- -39- APPL NUMBER: 17-50041457 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 11/30/17 AP T/S: 11/30/2017 12 :10 PM DETAYLOR R429 02 12/01/17 FOUR TRADE FINAL TIME: 17:00 VRU #: 003060126 24 ( (� T/S: 11/30/2017 12 :02 PM LLUCAS COMMENTS AND NOTES