CO INSPECTION feghiSSASSisiSSAStis
COUNTY OF HARNETT 13
t Building Inspections Department
Planning Services
IlkCertificate of Compliance: Occupancy: 4-------- 4
Certificate issued pursuant to the regutrements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances.
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the $.M
North Carolina State Building Codes. For the fol owing
Use Classification p i---: li it--1, - Permit Numbers (,�
Name: Cc ti C LWc i.�_sz Lez4 �-I_� Building: "--e'
b
// Electrical:
Address:.i"� (t4= C /r '., � Insulation: -014-11
Pl
_ _ Mechanic
MechanicaC
MFG Home:
Date: J 2_// i 7 Building Official: c X �==- — /
PREPARED 11/30/17, 14:13 :03 INSPECTION TICKET PAGE 14
Hatnett'County INSPECTOR: IVR DATE 12/01/17
ADDRESSy . 324 CLARK RD SUBDIV:
CONTRACTOR : VALUE BUILD HOMES PHONE : (919) 777-0393
OWNER . . : WADE HERBERT LEE & C PHONE : (910) 893-4517
PARCEL . . : 13-0527- - -0020- - -
APPL NUMBER: 17-50041438 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 05/19/2017 03:10 PM BPETRICH --
324 CLARK ROAD LILLINGTON 27546
RT 27 TO CLARK ROAD - USE SHARED
DRIVEWAY TO GET TO THE BACK OF THE
PROPERTY
STRUCTURE: 000 000 35X41 3BD CRAWL
FLOOD ZONE • FLOOD ZONE X
If BEDROOMS - 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW WATER SUPPLY • NEW WELL
PERMIT: CPS* 00 CP * SPD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
A814 01 6/29/17 TW ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002990745
7/07/17 AP 282 CLARK RD LILLINGTON 27546
**** POST # ON HOME, POST #S ON A SIGN AT DRIVEWAY ENTRANCE
AT CLARK RD AND POST #282 ON A SIGN WHERE ACCESS SPLITS OFF
OF 278 .TWARD.
T/S: 07/07/2017 12 :08 PM TWARD
8101 01 6/29/17 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 002990752
6/29/17 AP T/S: 06/27/2017 04:49 PM LLUCAS
NO T-POLE
B103 01 7/20/17 TSG R*BLDG FOUND & TEMP SVC POLE VRU #: 002999893
7/20/17 DA CLEAN OUT INSIDE OF FOUNDATIONOR GET AN ENG TO VERIFY THE
FOOTING PROJECTION. DO NOT BACK FILL FOUNDATION UNTILL
AFTER IT HAS BEEN INSPECTED.
8103 02 7/25/17 JLP R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003001617
7/25/17 AP T/S: 07/21/2017 10:37 AM LLUCAS
T/S: 07/24/2017 08:13 AM LLUCAS
No t-pole on site.
B105 01 7/28/17 TSG R*OPEN FLOOR TIME: 17:00 VRU #: 003003712
7/28/17 DA T/S: 07/27/2017 11:58 AM DJOHNSON
CUSTOMER WOULD LIKE AFTERNOON IF POSSIBLE
job not ready
B113 01 7/28/17 TSG R*BLDG WATER/DAMP PROOFING TIME: 17:00 VRU #: 003003704
7/28/17 DA T/S: 07/26/2017 08:53 AM LLUCAS
WOULD LIKE AFTERNOON IF POSSIBLE
foundation back filled could not inspect
E207 01 7/28/17 TSG R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU #: 003003720
7/28/17 DA T/S: 07/27/2017 11:58 AM DJOHNSON
CUSTOMER WOULD LIKE AFTERNOON IF POSSIBLE
meter already set
B105 02 8/01/17 TSG R*OPEN FLOOR TIME: 17:00 VRU #: 003006186
8/01/17 AP T/S: 07/31/2017 01:31 PM JBROCK
T/S: 08/01/2017 02 :51 PM SGUY
8113 02 8/01/17 TSG R*BLDG WATER/DAMP PROOFING TIME: 17 :00 VRU #: 003006178
8/01/17 DA T/S: 07/31/2017 01:31 PM JBROCK
foundation back filled could not inspect
E207 02 8/01/17 TSG R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU #: 003006194
CONTINUED ONTO NEXT PAGE
PREPARED 11/30/17, 14:13:03 INSPECTION TICKET PAGE 15
HafnettZCounty INSPECTOR: IVR DATE 12/01/17
ADDRESS . : 324 CLARK RD SUBDIV:
CONTRACTOR : VALUE BUILD HOMES PHONE : (919) 777-0393
OWNER . . : WADE HERBERT LEE & C PHONE : (910) 893-4517
PARCEL . . : 13-0527- - -0020- - -
APPL NUMBER: 17-50041438 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
8/01/17 DA T/S: 07/31/2017 01:32 PM JBROCK
this inspection already done
HB24 01 8/14/17 AC ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003014784
8/14/17 AP T/S: 08/18/2017 10:23 AM KHINSON
T/S: 08/18/2017 10:23 AM KHINSON
R425 01 8/30/17 TSG FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003017159
8/30/17 DA T/S: 08/24/2017 11:15 AM LLUCAS
T/S: 08/25/2017 11:53 AM LLUCAS
T/S: 08/28/2017 08:14 AM LLUCAS
T/S: 08/29/2017 08:55 AM BPETRICH
1-FLASHING REQUIRED AT FRONT PORCH 2-INSULATION BAFFLES NOT
INSTALLED 3-HEAD TEST DOWN 4- REAR DOOR MISSING 5-AIR
BARRIER REQUIRED BEHIND TUB/SHOWERS. 6-ATTACH PORCH POST
PRE PLAN. 7-SLOT IN ROOF RIDGE VENT IS GREATER THAN 3' 1/4
8-BLOCK ROOF RIDGE VENT AT END WALL PER MFG. 9-HOUSE WRAP
AT SLIDER MISSING.
DO NOT SIDE OR INSUATE
R425 02 9/11/17 TSG FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003023108
9/11/17 DA T/S: 09/08/2017 01:43 PM LLUCAS
plumbing head test still down
ok to side do not insulate
R425 03 9/13/17 TSG FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003023694
9/13/17 AP T/S: 09/11/2017 04:43 PM BPETRICH
I129 01 9/18/17 TSG R+INSULATION INSPECTION TIME: 17:00 VRU #: 003025764
9/18/17 AP T/S: 09/14/2017 04:41 PM BPETRICH
T/S: 09/18/2017 03:21 PM SGUY
M305 01 11/20/17 KS R'PLUMB SEWER CONNECTION TIME: 17:00 VRU #: 003054699
11/20/17 AP T/S: 11/16/2017 11:14 AM BPETRICH
T/S: 11/20/2017 01:55 PM KSLATTUM
P307 01 11/20/17 KS R'PLUMB WATER CONNECTION TIME: 17:00 VRU #: 003054707
11/20/17 AP T/S: 11/16/2017 11:15 AM BPETRICH
T/S: 11/20/2017 01:55 PM KSLATTUM
E209 01 11/22/17 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003057205
11/22/17 DA T/S: 11/21/2017 03:21 PM LLUCAS
1)Grounds rods.2)Missing back porch light.3)Identify 12/2
loose wire in panel with no breaker.
E209 02 11/28/17 KS R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003057841
11/28/17 AP T/S: 11/27/2017 08:54 AM LLUCAS
T/S: 11/28/2017 12:42 PM KSLATTUM
H828 01 11/28/17 AC ENVIRO. WELL PERMIT TIME: 17:00 VRU #: 003059300
11/28/17 AP T/S: 11/29/2017 10:54 AM KHINSON
T/S: 11/29/2017 10:54 AM KHINSON
R429 01 12/01/ FOUR TRADE FINAL TIME: 17:00 VRU #: 003059573
/ T/S: 11/29/2017 12:59 PM LLUCAS
COMMENTS AND NOTES