CO INSPECTION - ittititiltit is iiatg 1 titatt SA tt &
COUNTY OF HARNETT
Building Inspections Department
ill
Planning Services
Certificate of Compliance: Occupancy: X
Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances. f
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the .�
North Carolina State Building Codes. For the following00 : i.'s
Use Classification: ke s t k e i\-"\---t o t Permit Numbers
Name: Ro�lc.l 0,,. c � Ack ;r,. r-� Building: 4
Electrical: 0 1
Address:r1 11 , 1_,, �J
- Insulation:
'/ Plumbing: ''
0,01
Mechanical: \--V
. MFG Home:
Date: 1 t 30 - 1 Building Official: / � --1 _C 9.,
PREPARED 11/29/17, 14 :05:28 INSPECTION TICKET PAGE 12
Harnett County INSPECTOR: IVR DATE 11/30/17
=DRESS . : 17 AFTON CT SUBDIV: ATKINS VILLAGE PH 3
CONTRACTOR : ROYAL OAKS BUILDING GROUP LLC PHONE : (919) 233-3886
OWNER . . : ROYAL OAKS BUILDING GROUP PHONE :
PARCEL . . : 04-0664- - -0020- -38-
APPL NUMBER: 17-50040975 CP NEW RESIDENTIAL (SFD)
DIRECTIONS T/S: 03/21/2017 08:39 AM JBROCK ----
ATKINS VILLAGE #36
T/S: 07/31/2017 01:24 PM JBROCK ----
premise # 40073206
CALLED DUKE - 10/31/17. . .LL
STRUCFORE: 000 000 55X42 3BDR CRAWL W/ GARAGE A DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 3.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
A814 01 7/19/17 SB ADDRESS CONFIRMATION TIME: 17 :00 VRU #: 002999068
7/19/17 AP 17 AFTON CT FUQUAY VARINA 27526
T/S: 07/19/2017 12:39 PM SBENNETT
B101 01 8/01/17 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 003006079
8/01/17 DA T/S: 07/31/2017 01:08 PM JBROCK
eng letter on site
T/S: 08/01/2017 01:57 PM KSLATTUM
Need engineers letter to state that footing meets NC
Residential Code. T-pole conduit broken.
B103 01 8/01/17 KS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003006095
8/01/17 AP T/S: 07/31/2017 01:09 PM JBROCK
T/S: 08/01/2017 01:58 PM KSLATTUM
T-pole conduit broken.
B101 02 8/07/17 JLP R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 003008810
8/07/17 AP T/S: 08/04/2017 02:41 PM JBROCK
eng letter has to be on site monday morning
T/S: 08/07/2017 01:46 PM JPERRY
B105 01 8/07/17 JLP R*OPEN FLOOR TIME: 17:00 VRU #: 003008828
8/07/17 DA T/S: 08/04/2017 02 :42 PM JBROCK
1-Missed anchor bolts on back right wall of garage.
8105 02 8/08/17 SLP R*OPEN FLOOR TIME: 17:00 VRU #: 003009495
8/08/17 AP T/S: 08/07/2017 02:30 PM JBROCK
T/S: 08/08/2017 03:38 PM JPERRY
8104 01 9/12/17 JS R*FOUND & SETBACK VERIF SURVEY TIME: 17:00 VRU #: 003023744
9/12/17 AP T/S: 09/12/2017 08:09 AM JBROCK
R425 01 9/12/17 JLP FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003023538
9/12/17 CA T/S: 09/11/2017 12:33 PM JBROCK
Per contractor
R425 02 9/15/17 BS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003025087
9/15/17 AP T/S: 09/14/2017 07:45 AM JBROCK
T/S: September 15, 2017 02:00 PM BSUTTON
Truss hangers require 16 d and 10d nails per documents. 2 .
Plumbing pressure down to 50 psi. OK to side/insulate
I129 01 9/20/17 JLP R*INSULATION INSPECTION VRU #: 003027323
9/20/17 AP T/S: 09/20/2017 03:06 PM JPERRY
R125 01 9/27/17 DT ONE TRADE ROUGH IN TIME: 17:00 VRU #: 003030392
CONTINUED ONTO NEXT PAGE
PREPARED 11/29/17, 14 :05:28 INSPECTION TICKET PAGE 13
Harnett County INSPECTOR: IVR DATE 11/30/17
ADDRESS : 17 AFTON CT SUBDIV: ATKINS VILLAGE PH 3
CONTRACTOR : ROYAL OAKS BUILDING GROUP LLC PHONE : (919) 233-3886
OWNER . . : ROYAL OAKS BUILDING GROUP PHONE :
PARCEL . . : 04-0664- - -0020- -38-
APPL NUMBER: 17-50040975 CP NEW RESIDENTIAL (SED)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
9/27/17 AP T/S: 09/26/2017 08:18 AM LLUCAS
STONE PREP
T/S: 09/27/2017 12 :26 PM DETAYLOR
H824 01 10/19/17 AC ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU #: 003042439
10/19/17 AP T/S: 10/20/2017 11:03 AM KHINSON
T/S: 10/20/2017 11:04 AM KHINSON
E209 01 10/26/17 DT R*ELEC TEMP POWER CERT VRU p: 003044278
10/26/17 AP T/S: 10/26/2017 01:30 PM DETAYLOR
R429 01 11/21/17 B5 FOUR TRADE FINAL VRU 4: 003056033
11/21/17 DA T/S: November 21, 2017 12:46 PM BSUTTON
Water heater and heat breaker labeled wrong. 2. Master
Vanity right not plumbed to drain 3. Repair foundation
under deck. 4. Bolts missing in deck bracing. 5. Condensate
drain on down unit needs pump. Drain under house for second
floor unit does not have proper grade.
R429 02 11/30/17 TI FOUR TRADE FINAL VRU $ : 003059243
I t 130/11 Ae
COMMENTS AND NOTES