Loading...
ENG LETTER /[ CCLANCY ENGINEERING 1204 Bethpage Dove 919 387 -7-13 Mebane North Carcima 25302 seivice;it,mcclancyeng rem December 4, 201.7 -7 .,n line Lamco Custom Builders. LLC / `-SW ``° " ' Attention. Tony Two 7424 Chapel Hill Rd. Suite 203 Raleigh NC 27607 Re' Construction Investigation 88 Brookview Court Angier. NC File#17-1267 Mr Toro As authorized. McClancy Engineering. PC performed an evaluation at the above site on December 1. 2017 The site investigation was performed and tnis report written by Mr John McClancy, P.E.. president of McClancy Engineering. As we understand it. our assign-rent was to evaluate the installation of the exterior wail insulation that had not been subjected to the required inspection by the local code official having jurisdiction It was reported the interior drywall panels intended for the adjacent property had been mistakenly installed in the subject property before the insu,ation inspection was conducted As requested. our services are of limited scope, involving only these issues Although we may note other conditions that come to our attention, we have not performed an in-depth inspection or investigation of any other aspects of the construction. The subject property was a single family residence under construction on a semi-rural building :or in Angier, Harnett County. North Carolina. The building was dried in. with the interior drywall installed and partially finished. Interior trim and finish details had hot been installed Ceiling and floor insulation had not been installed Evaluation of the exterior wall insulation was accomplished by the combination of visual inspection of the various wati penetrations (at winnows, doors, outlet boxes etc and surveying the walls with a Seek Thermal model 1E0010M infrared camera • Based on the available evidence, I conclude that the exterior wails at the subject residence were properly insulated as required by the 2012 NC Residential Building Code r Lamco Custom Builders, LLC December 4, 2017 Re: 88 Brookview Cr, Angier, NC Page 2 Project# 17-1267 The comments and conclusions contained n this report are based primarily on the observations of the structure and the goalifeo knowleoge and experience of this office All conclusions are considered accurate to a reasonaole degree of engineering certainty based on the evidence available at the time the report was issued. All conclusions are subject to revision based on receipt of new or additional information All services are provided exercising a level of care and diligence equivalent to other professional engineers providing sim, ar services under similar conditions. No other warranty. expressed or implied is offered. Our services are confidential n nature and we will not release this report to any otner party without your express consent. The use of this engineering work is limited to the express purpose for which It was commissioned and it may not be reused. copied or distnouted for any other pLroose Without the express written permission of McClancy Engmeerng. Please call if you have any questions or we can be of further assistance. Thank you for using McClancy Engineering. Respectfully submitted. McCLANCY INEERING, PC 0 John McClahcy,-PE 61 ii McClancy Et}g;[leer. g. PC �" �@ dr, NOPE #15841'x':.°• p vil.c Firm #C-2205 �':. ' - - JCM/tzm