INSPECTION W/ ENG INFO PREPARED 10/30/17, 14 :20:03 INSPECTION TICKET PAGE 40
H/rnett County INSPECTOR: IVR DATE 10/31/17
ADDRESS . : 464 AVERY POND DR SUBDIV: AVERY POND PH2 BOLTS
CONTRACTOR : WYNN CONSTRUCTION, INC. PHONE : (919) 528-1347
OWNER : LITTLE CROSS LLC PHONE :
PARCEL . . : 08-0653- - -0029- -56-
APPL NUMBER: 17-50041495 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 05/26/2017 11:25 AM JBROCK ----
AVERY POND 452
T/S: 09/12/2017 09:47 AM JBROCK ----
Premise# 26850570
STRUCTURE: 000 000 60X60 4HDR CRAWL W/ GARAGE & COV H PORCH
FLOOD ZONE - FLOOD ZONE X
# BEDROOMS • 4000000.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP • SPD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
A814 01 9/08/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 003022787
9/08/17 AP 464 AVERY POND DR FUQUAY VARINA 27526
T/S: 09/08/2017 09:55 AM SBENNETT
B101 01 9/08/17 JLP R*BLDG FOOTING / TEMP SVC POLE TIME: 17 :00 VRU #: 003022795
9/08/17 AP T/S: 09/07/2017 01:44 PM HPETRICH
T/S: 09/08/2017 02:24 PM JPERRY
B103 01 9/15/17 BS R*BLDG FOUND & TEMP SVC POLE VRU # : 003025269
9/15/17 DA T/S: September 15, 2017 10:46 AM BSUTTON
Install damproofing. Leave exterior open for inspoection.
B104 01 9/18/17 JB R*FOUND & SETBACK VERIF SURVEY TIME: 17 :00 VRU #: 003026416
9/18/17 AP T/S: 09/18/2017 08:47 AM JBROCK
B103 02 9/19/17 JLP R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003026713
9/19/17 AP T/S: 09/18/2017 01:38 PM JBROCK
T/S: 09/19/2017 03:13 PM JPERRY
B105 01 9/27/17 BS R*OPEN FLOOR TIME: 17:00 VRU #: 003030772
9/27/17 AP T/S: 09/26/2017 01:49 PM JBROCK
T/S: September 27, 2017 02:40 PM BSUTTON
R425 01 10/20/17 BS FOUR TRADE ROUGH IN TIME: 17: 00 VRU #: 003042033
10/20/17 DA T/S: 10/19/2017 01:38 PM HPETRICH
T/S: October 20, 2017 11:42 AM BSUTTON
1. Flash front porch. Do not pour. 2 . Nail nook LVL left
side. 3 . Need structural nail plate or strapping at top
plate for TV conduit. Ok to side/insulate. Do not cover
front porch.
I129 01 10/26/17 BS R*INSULATION INSPECTION TIME: 17:00 VRU #: 003044351
10/26/17 AP T/S: 10/25/2017 10:56 AM BPETRICH
T/S: October 26, 2017 12 :34 PM BSUTTON
R425 02 10/26/17 BS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003044377
10/26/17 DA T/S: 10/25/2017 10:56 AM BPETRICH
T/S: October 26, 2017 12 :34 PM BSUTTON
Need a repair on floor truss directly over stairs drilled
for electrical. This was missed on the original inspection.
R425 03 10/31/17 T FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003046869
0 VII/ T/S: 10/30/2017 12 :01 PM LLUCAS
COMMENTS AND NOTES
r' a
JANUARY 1, 2009 STANDARD REPAIR DETAIL FOR REMOVING A ST-REPO6
SECTION OF THE END PANEL OF A FLOOR TRUSS
H Mlrek usA.Inc. Page 1 of 1
•
M(Tek USA,Inc.
•
3.3-MAX
•
REFER TOIAL TRUSS DESIGN
SIZES
FOR PLATE SIZES AND LUMBER GRADES
6'MIN I/2'MIN - - -- --
` --...
•
SECTION REMOVED
• DIAGONAL WEB MUST BE IN THIS ORIENTATION(COMPRESSION WEB)
APPLY 2%042 SPE NO.2 (OR BETTER)SCAB TO ONE FACE
OF TRUSS WITH 1 ROW OF I6:1(3'X D.131')NAILS SPACED 3'O.C.
1.THIS ISA SPECIFIC REPAIR DETAIL TO SE USED ONLY FOR RS ORIGINAL
INTENTION.THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION
' OF THE TRUSS IS UNDAMAGED.THE ENTIRE TRUSS SHALL BE INSPECTED TO
VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED.WHEN THE REDUIRFO
REPAIRS ARE PROPERLY APPLIED,THE TRUSS WILL BE CAPABLE OF SUPPORTING
THE LOADS INDICATED.
2.ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE
APPLYING REPAIR AND HEW IN PLACE DURING APPLICATION OF REPAIR.
3.THE END DISTANCE,EDGE DISTANCE,AND SPACING OF NAILS SHALL BE
SUCH AS TO AVOID SPLITTING OF THE WOOD •
4.LUMBER MUST BE CUT CLEANLY AND ACCURATELY AND THE REMAINING WOOD MUST BE UNDAMAGED.
' S THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES WITH 40-10-00 WADING IN THE 3X_OR AX_ORIENTATION ONLY.
6. CUTTING IS PERMITTED WITHIN 1/2'Of CONNECTOR PLATES,AND MUST NOT AFFECT PLATES IN ANY WAY.
•