INSPECTION W/ ENG INFO PREPARED 10/30/17, 14 :20:03 INSPECTION TICKET PAGE 40 H/rnett County INSPECTOR: IVR DATE 10/31/17 ADDRESS . : 464 AVERY POND DR SUBDIV: AVERY POND PH2 BOLTS CONTRACTOR : WYNN CONSTRUCTION, INC. PHONE : (919) 528-1347 OWNER : LITTLE CROSS LLC PHONE : PARCEL . . : 08-0653- - -0029- -56- APPL NUMBER: 17-50041495 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 05/26/2017 11:25 AM JBROCK ---- AVERY POND 452 T/S: 09/12/2017 09:47 AM JBROCK ---- Premise# 26850570 STRUCTURE: 000 000 60X60 4HDR CRAWL W/ GARAGE & COV H PORCH FLOOD ZONE - FLOOD ZONE X # BEDROOMS • 4000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SPD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS A814 01 9/08/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 003022787 9/08/17 AP 464 AVERY POND DR FUQUAY VARINA 27526 T/S: 09/08/2017 09:55 AM SBENNETT B101 01 9/08/17 JLP R*BLDG FOOTING / TEMP SVC POLE TIME: 17 :00 VRU #: 003022795 9/08/17 AP T/S: 09/07/2017 01:44 PM HPETRICH T/S: 09/08/2017 02:24 PM JPERRY B103 01 9/15/17 BS R*BLDG FOUND & TEMP SVC POLE VRU # : 003025269 9/15/17 DA T/S: September 15, 2017 10:46 AM BSUTTON Install damproofing. Leave exterior open for inspoection. B104 01 9/18/17 JB R*FOUND & SETBACK VERIF SURVEY TIME: 17 :00 VRU #: 003026416 9/18/17 AP T/S: 09/18/2017 08:47 AM JBROCK B103 02 9/19/17 JLP R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003026713 9/19/17 AP T/S: 09/18/2017 01:38 PM JBROCK T/S: 09/19/2017 03:13 PM JPERRY B105 01 9/27/17 BS R*OPEN FLOOR TIME: 17:00 VRU #: 003030772 9/27/17 AP T/S: 09/26/2017 01:49 PM JBROCK T/S: September 27, 2017 02:40 PM BSUTTON R425 01 10/20/17 BS FOUR TRADE ROUGH IN TIME: 17: 00 VRU #: 003042033 10/20/17 DA T/S: 10/19/2017 01:38 PM HPETRICH T/S: October 20, 2017 11:42 AM BSUTTON 1. Flash front porch. Do not pour. 2 . Nail nook LVL left side. 3 . Need structural nail plate or strapping at top plate for TV conduit. Ok to side/insulate. Do not cover front porch. I129 01 10/26/17 BS R*INSULATION INSPECTION TIME: 17:00 VRU #: 003044351 10/26/17 AP T/S: 10/25/2017 10:56 AM BPETRICH T/S: October 26, 2017 12 :34 PM BSUTTON R425 02 10/26/17 BS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003044377 10/26/17 DA T/S: 10/25/2017 10:56 AM BPETRICH T/S: October 26, 2017 12 :34 PM BSUTTON Need a repair on floor truss directly over stairs drilled for electrical. This was missed on the original inspection. R425 03 10/31/17 T FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003046869 0 VII/ T/S: 10/30/2017 12 :01 PM LLUCAS COMMENTS AND NOTES r' a JANUARY 1, 2009 STANDARD REPAIR DETAIL FOR REMOVING A ST-REPO6 SECTION OF THE END PANEL OF A FLOOR TRUSS H Mlrek usA.Inc. Page 1 of 1 • M(Tek USA,Inc. • 3.3-MAX • REFER TOIAL TRUSS DESIGN SIZES FOR PLATE SIZES AND LUMBER GRADES 6'MIN I/2'MIN - - -- -- ` --... • SECTION REMOVED • DIAGONAL WEB MUST BE IN THIS ORIENTATION(COMPRESSION WEB) APPLY 2%042 SPE NO.2 (OR BETTER)SCAB TO ONE FACE OF TRUSS WITH 1 ROW OF I6:1(3'X D.131')NAILS SPACED 3'O.C. 1.THIS ISA SPECIFIC REPAIR DETAIL TO SE USED ONLY FOR RS ORIGINAL INTENTION.THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION ' OF THE TRUSS IS UNDAMAGED.THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED.WHEN THE REDUIRFO REPAIRS ARE PROPERLY APPLIED,THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2.ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HEW IN PLACE DURING APPLICATION OF REPAIR. 3.THE END DISTANCE,EDGE DISTANCE,AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID SPLITTING OF THE WOOD • 4.LUMBER MUST BE CUT CLEANLY AND ACCURATELY AND THE REMAINING WOOD MUST BE UNDAMAGED. ' S THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES WITH 40-10-00 WADING IN THE 3X_OR AX_ORIENTATION ONLY. 6. CUTTING IS PERMITTED WITHIN 1/2'Of CONNECTOR PLATES,AND MUST NOT AFFECT PLATES IN ANY WAY. • PDF created with pdfFactory Pro trial version www.pdffactorv.com