Loading...
INSPECTION W/ ENG LETTER PREPARND 10/18/17, 14:17:37 INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 10/19/17 ADDRESS . : 115 FOLLY CT SUBDIV: SWEETWATER 71LOTS CONTRACTOR : IVERCON INC. PHONE : (910) 237-3461 OWNER . :'DIVERSIFIELD INVESTORS INC PHONE : PARCEL . . : 01-0544- - -0004- -61- APPL NUMBER: 17-50041167 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 04/18/2017 08:42 AM JBROCK ---- SWEETWATER #53 STRUCTURE; 000 000 54X48 4BDR SLAB W/ GARAGE & PORCH FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 4000000 .00 PROPOSED USE • SFD SEPTIC - EXISTING' - NEW TANK WATER SUPPLY • COUNTY PERMIT: CPSP 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS A814 01 7/19/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002999530 7/19/17 AP 115 FOLLY CT LINDEN 28356 T/S: 07/19/2017 12 : 10 PM SBENNETT B101 01 7/19/17 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 002999548 7/19/17 DA T/S: 07/18/2017 02 :05 PM LLUCAS 1)Clean out loose dirt from footings.2)Step down boards need to be 12" from step down & The depth of the footings witch is 8" . 3101 02 7/20/17 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU P: 003000445 7/20/17 AP T/S: 07/19/2017 02 :02 PM LLUCAS T-POLE PASSED B103 01 7/25/17 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003002136 7/25/17 DA T/S: 07/24/2017 08: 10 AM LLUCAS Clean off footings inside & outside of foundation wall for this inspection B103 02 7/28/17 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003004876 7/28/17 DA T/S: 07/27/2017 11:39 AM LLUCLS NO PROJECTION on house side of garage wall on right side front to back corner & on end of left wing wall. B103 03 8/01/17 JLP R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003006343 8/01/17 DA T/S: 07/31/2017 02:13 PM LLUCAS LOOK AT SPECIAL FOOTING REPAIR Need Engineer letter on repair B103 04 8/16/17 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003013265 8/16/17 AP T/S: 08/16/2017 08:05 AM DJOHNSON PER ENGINEER LETTER P309 01 8/16/17 JH R*PLUMB UNDER SLAB TIME: 17:00 VRU #: 003013042 6/16/17 AP T/S: 08/15/2017 02 :17 PM LLUCAS ENGINEER LETTER FOR FOUNDATION IS IN PERMIT BOX 3111 01 8/22/17 JH R*BLDG SLAB INSP/TEMP SVC POLE TIME: 17:00 VRU #: 003015229 8/22/17 AP T/5: 08/21/2017 08:37 AM LLUCAS B104 01 10/09/17 LL R*FOUND & SETBACK VERIF SURVEY TIME: 17:00 VRU #: 003036605 10/09/17 AP T/S: 10/09/2017 04 :07 PM LLUCAS T/S: 10/09/2017 04:08 PM LLUCAS R425 01 10/11/17 JH FOUR TRADE ROUGH IN TIME: 17: 00 VRU #: 003036431 10/11/17 DP T 5: 10/09/2017 02 :22 PM BPETRICH Strap header on each end of garage door from topplate to CONTINUED ONTO NEXT PAGE PREPAR$D 10/18/17, 14 :17:37 INSPECTION TICKET PAGE 14 Harnett County INSPECTOR: IVR DATE 10/19/17 ADDRESS . : 115 FOLLY CT SUBDIV: SWEETWATER 71L0TS CONTRACTOR : IVERCON INC. PHONE : (910) 237-3461 OWNER . :' DIVERSIFIELD INVESTORS INC PHONE PARCEL . . : 01-0544- - -0004- -61- APPL NUMBER: 17-50041167 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 1i below header.a/Missing anchor bolts per code throughout house. *,)Need engineers letter for bottom plate on front wall of house & back wall in garage not full bearing.N Strap gas line in garage per code.5tNeed 8-16 penny nails in each end of structual nail guatd over electrical panel.B0Fi11 all holes under tubs & showers.)Anchor all interior load bearing walls per codeAR Missing nail guard on water line in loft at master toilet wall&)Replace all short is in roof truss hangers in loft with correct size nails Need tempered window at tub in spare bath on back wall.]i)Fire caulk wire in top plate in back left bed closet on end wall.AN)Missing air barrier in chase in back left bedroom closet 4p eed to inspect back porch footings before they are poured. DO NOT INSULATE OK TO SIDE R425 02 10/19 17 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 003040904 T/S: 10/18/2017 08:16 AM LLUCAS COMMENTS AND NOTES FR FRLEMING UCTURAL & ASSOC ATESSPAA Principals:Stephen Fleming, PE, RRC • J.Ben Rogers.PE • Sarah Duncan:.rE • John L. Kels,PE,SE ' October 16,2017 Ivercon P.O. Box 64778 Fayetteville,NC 28306 Attention:Troy Iverson Re:Wall stud analysis 115 Folly Court Linden,NC 28356 Our Job.No. 17-150 Dear Mr. Iverson, A site visit was made on Friday October 13, 2017 to review the situation with the load bearing wood stud walls that are not fully bearing on the slab in two locations. The first location is the back wall of the garage and the other location is the front wall of the house at the porch. At both locations,the studs are hanging%"to 1"off the edge of the slab sn grade of the house. The studs were analyzed for the loads from the roof or floor trusses at bob locations and were found to be adequate to support the applied loads. If you have any questions or need additional information please let me know. Fleming&Associates,P.A. J.Ben Rogers,P.E. „rmuun4 \•N CARp • ./ joifiv77 E SEAL 022922 tttt4unIH• tt www.flemingandassociales.wr. 910.433.2825 Ph .910.433.26041' 1004 Hay Street.Fayetteville,North Carc Ana 13305