Loading...
INSPECTION W/ ENG LETTER PREPARED 10/16/17, 19:12:07 INSPECTION TICKET PAGE 34 Harnett County INSPECTOR: IVR DATE 10/17/17 ADDRESS . : 94629 •UNASSIGNED SUBDIV: M G THOMAS & DORA S THOMAS CONTRACTOR : TCC VANDERBUILT LLC PHONE : (919) 774-6319 OWNER . . : LESTER JOHN WALTER & DOROTHY A PHONE : (910) 485-3647 PARCEL . . : 13-0509- - -0121- -15- APPL NUMBER: 17-50041610 CP MODULAR HOME DIRECTIONS : T/S: 06/13/2017 10:50 AM BPETRICH -- TAKE 421 TO DEAN ROAD - TURN LEFT ONTO DEAN RD - RIGHT ONTO OLD 421 - LEFT ONTO LLOYD STUART RD - LEFT ONTO EMERALD LANE - SITE IS THE SECOND DRIVEWAY ON THE RIGHT (AT THE END) STRUCTURE: 000 000 76X30 3BD 2BA OFF FRAME MOD W/GAR W/DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS 3 .00 SEPTIC - EXISTING' - EXISTING WATER SUPPLY ' COUNTY PERMIT: CPMH 00 CP MODULAR REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 8/18/17 TSG R*BLDG FOOTING / TEMP SVC POLE VRU #: 003013943 8/18/17 AP A814 01 8/22/17 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 003015427 8/22/17 AP 72 EMEPLTD LN BROADWAY 27505 T/S: 08/22/2017 08:53 AM SBENNETT B103 01 9/28/17 TSG R*BLDG FOUND & TEMP SVC POLE VRU #: 003030847 9/28/17 DA 1-FOUNDATION MISSING 2" PROJECTION IN AREAS VISIBLE, FOOTER NEEDS CLEANING OFF TO INSPECT AND ENGINEERING REQUIRED ON PROJECTION.2-ATTACH SEAL PLATE TO FOUNDATION C163 01 10/13/17 TSG C*BLDG FLOOR FRAMING VRU #: 003038304 10/13/17 DP Marriage wall Inspection. Key will be in permit box! 1- THE FOUNDATION INSPECTION HAS NOT BEEN PAST ON THE JOB. THE LAST INSPECTION REQUIRED ENGINEERING ON THE FOUNDATION WE HAVE NOT RECIVED A LETTER FROM ENG FOR THIS JOB B103 02 10/17 (r TIN R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 003039807 Al T/S: 10/16/2017 11:38 AM JBROCK B119 01 10/184-7 TI� R*MOD MARRIAGE WALL TIME: 17 : 00 VRU # : 003039815 T/S: 10/16/2017 11:38 AM JBROCK eng letter on jb's desk COMMENTS AND NOTES WILLIAM A. PERSON, P.E. cow.UIVc [Auxi to o.)1414411-322S 774A El-Cur i Ru. 1I-A.0(919)4%-3273 I ni NC 27519 I-6011-545-34% October 6, 2017 Four Oaks Development Co. P.O. Box 87 Four Oaks, N.C. 27534 Re: Footing Inspection 72 Emerald Lane Broadway, N.C. Dear Sirs: On 10/4/17, an inspection was performed on the prepared footing excavations for the repair to the footing projection for the off frame modular home at the location described above. The footing projection has been repaired by excavating alongside the footing for an approximate depth of 10" for an approximate width of 12"for the locations shown on the attached sheet Si. Number 5 rebar dowels have inserted into the existing footing and project into the prepared footing repair.The resulting construction will structurally adequate for the site conditions and the loads specified by the manufacturer and the North Carolina Residential Building Code, 2012 edition.The footings were approved for placement of concrete. • n Sincerely. viilliamtA.Perstin?E .. esti II.u.,,,,\P - WILLIAM A, PERSON, PE FOUR OAK5 DEV. CO. 774A F F COTTRELL RD. 72 EMERALD W., BROADWAY. NC LOUISBURG, N.C. 27549 FOOTING REPAIR (919)496-5228 °'R. I0/6/17 """' "'tr'N0 51 IOZO 2 w � w o zti s 0 O O