Loading...
PR APP Blgd 1Harnett WNW (W RNC- Fire Marshal Division Pic EMERGENCYRI . P.O. Box 370 Lillington, NC 27546 910-893-7580 Application for Plan ruK WOF COMPLIANCE Review AN -E OFFICEO DATE Application # —ZZ- 900q� 4 2(/ Date Received: 9 2Ca ��_ Received By: Name of Project: pj,(A, &e*,,,My. m(2, Physical Address of Project. :, ` Xa1,1 NC 21s0 1 Plans Submitted By: C—aLL1t-A -1;? VA, Project Phone: PIN )- Contact Person/Address: 1 jiCa ..l-tJ�tCaQpj ���sJRi1`{ A)Zo\ \Al- -QQv� ?,��►�; �; l�Z CaQ`; tc 215103 Contact Phone: ( p=it q, )- X231 -01U-2-. ( )- Contractor's Name/Info: SP�m Contractor's Phone: ((,1W(E ,- Plans that are submitted will be reviewed as quickly as possible with an average time of review between 7-10 working days. • Status checks may be conducted on plan reviews by visiting the website http://hteweb.harnett.org/Click2GovBP/Index.isp or by calling the Harnett County Central Permitting Office (910-893-4759), or the Harnett County Fire Marshal's Office (910-893-7580). • Approved plans must be picked up from the Central Permitting Office and all fees paid before any required inspections can be conducted. tqco Tyco Integrated Security 14001 Weston Parkway Integrated Security Site 102 Cary, NC 27513 Tel: (919) 337-9262 Fax: (919) 337-9310 www.tycois.com September 26, 2017 Attn: Bill Lamm Harnett County Fire Marshal Division 1005 Edwards Brothers Drive Lillington, NC 27546 RE: Panel replacement at Bob Barker (Bldg 1). Mr. Lamm, Please accept this letter of intent for Tyco to replace the existing FACP at Bob Barker, located 1446 James Norris Rd (Building 1) in Angier. The existing panel is an outdated and obsolete Focus 75. Our intention is to replace it with a new Vista128FBP. Once installed we will reconnect the circuits for the pull stations and sprinkler connections. Additionally, during our initial site visit to the location we noticed there was not currently a smoke detector installed at the panel. We are going to go ahead and provide one to meet NFPA 72 requirements. The new smoke detector will only have an additional 2.5mA draw. The job was estimated at 12 hours. So barring any unforeseen circumstances the system should only be down for not even a day, worst case will be 1-2. Upon completion, per your request, I will send you a report showing all transmitted and received signals. Please let me know if you have any further questions or comments. Thank you.. Collin D. Hurley% (919) 337-9262 p (919) 337-9310 f collinhurley@tyco.com VISTA®-128FBPN128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL The new VISTA-128FBP provides the ultimate protection of life and property. This UL Listed commercial fire and burglary control panel supports up to eight partitions and up to 128 zones/points using hardwired, wireless and V -Plexi addressable technologies. A diverse line of Honeywell FEATURES • Eight hardwired zones standard, expandable to 120 V-Plex addressable points/zones or 128 wireless points/zones • Can control eight separate areas independently (8 partitions) • Supports commercial wireless fire and burglary devices • Stores up to 512 events • Accommodates 150 user codes and up to 250 access card holders using VISTAKEY® Now UL864 9th Edition Approved initiating devices, notification circuits, communication devices, keypads, RF receivers and relays are also supported. The VISTA- 128FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. • Supports V -flex addressable VISTAKEY access control (1 to 8 doors) • Two on -board notification (bell) circuits delivering 2.3A @ 12V • Automatic smoke detector sensitivity maintenance testing • Four -wire smoke reset using onboard J2 output trigger • Supports Dynamic Signaling for AlarmNet Communicators • Supports Internet and GSM alarm reporting" • Supports graphical user interfaces for burglary use • Supports 6160CR-2 multi -LED fire keypad • Listed to UL864 9th Edition • Upload/download via Ethernet` • Carbon monoxide (CO) zone support When used with AlarmNet devices. 911*1_WV1WV'1 NEW -11 MIND 111M oil ADDITIONAL FEATURES • Notification Appliance Circuits (two): Programmable Temporal code compliant - Individually silenceable • Programmable on -board auxiliary relay • False alarm reduction features: Exit error logic Exit delay reset Cross zoning - Call waiting defeat Recent close report • Supports commercial hardwired, addressable V-Plex® polling loop and wireless zones • Hardwired zones Provides eight style B hardwired zones EOLR supervised for Fire and UL burglary installations- Supports N.O. or N.0 sensors - Individually assignable to any of eight partitions - Up to 16 two -wire smoke detectors each on zone one and two (32 total) - Up to 50 two -wire glassbreak detectors on zone eight • Patented addressable V -flex polling loop technology - Supports 120 two -wire zones points - Global polling technology for faster processing - Supervised by panel - Zones individually assignable to partitions, notification circuit (bell) output or auxiliary relay - 4,000 ft. capability without the use of shielded cable - Extender/Isolation bus modules - Eight zone - Class A and B expander module - Eight zone - Class B expander module - Single -zone supervised contact module • UL Listed wireless expansion Supports up to 128 wireless zones/points Supervised by control for check-in signals - Tamper protection for transmitters - Individually assignable up to eight partitions - Supports commercial wireless smoke detectors • Up to eight doors using VISTAKEY V-Plex Access Control • Event reporting • Local printer for event log printing • Communication - Phone line, GSM and IP communicator support - Panel operation during download SPECIFICATIONS Applications The VISTA- 128FBP control is well suited for a variety of applications as an integrated fire and burglary control. Some of the applications supported are: medical and professional buildings, churches or synagogues, office buildings, schools, strip malls, larger residences and factory or warehouse environments. Electrical • Primary power: 18VAC @ 72VA Honeywell No. 1451 • Control panel quiescent current draw: 300mA • Backup battery: 12VDC, 12AH min to 34AAH max - Lead acid battery (gel type) • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3A 12V • Aux. standby pwr: 12VDC, 1 A max • Total power: 2.3A at 12VDC • Standby time: 24 hours with 1A standby load using 34AAH battery • Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. • Optional 24 -volt kit Main Dialer • Line seize: Double Pole • Ringer equiv: 0.7B • Formats: ADEMCOO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics Backup Communication • Dual phone line capability using 514ODLM module • AlarmNetc GSM, i -GSM and IP Communicators Cabinet Dimensions • 18" H x 14.5" W x 4.3"D Environmental • Storage temp: 14° F to 158° F (-10° C to 70° C) • Operating temp: 32° F to 122° F (0° C to 50° C) • Humidity: 85% RH • EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive Agency Listings • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • UL611 /1610 Grades A, AA, Central Station • UL365 Grades A, AA Police Connect • UL864/NFPA72 Local, Central Station and Remote Station • UL985 • Factory Mutual • California State Fire Marshal • MEA • CAN/ULC S304 — Central and Monitoring Station Burglar Alarm Unit • CAN/ULC S527 — Central Unit for Fire Alarm Systems • CAN/ULC S303 — Local Burglar Alarm Unit • CAN/ULC S525 — Audible Signal Appliances COMPATIBLE DEVICES Auxiliary Devices • 6160CR-2 - Red Fire Keypad • 6160 - Burglary Keypad is 4204 - Relay Module, four form C contacts • 4204CF - Two supervised output circuits • 5881 Series RF receiver • 5883H RF receiver • 6220S - System printer used with 4100SM serial module Two -Wire Smoke Detectors Conventional • System Sensor • ESQ • DSC Horn/Strobes • System Sensor • Wheelock • Gentex Manual Pull Stations • 514OMPS-1 • 514OMPS-2 V-Plex (Addressable) Devices • 4208U Universal Eight -zone Expansion Module • 4101 SN Single Relay/Zone Module Product specifications subject to change. • ' ' • 4208SNF Class A/B Expander Module • 4190SN Remote Point Module - two zones • 4193SN and 4193SNP Two -zone Expander Modules V-Plex Extender/Isolation Modules • 4297 Extender/Isolator Module • VSI Isolator Module V-Plex Smoke Detectors • 5193SD • 5193SDT V-Plex Passive Infrared Detectors • 998MX • IS2500SN • DT7500SN V-Plex (Addressable) Contacts • 4939SN-WH • 4944SN-WH • 4959SN V-Plex Glassbreak Detectors •FG1625SN Optional 24V Kit • Order number: V128FBP924KT Commercial Wireless Devices • 5808W3 - Photoelectric Smoke/Heat Detector • 5806W3 - Photoelectric Smoke Detector • 5809 - Wireless Heat Detector • 5817CB - Wireless Commercial Transmitter • 5869 - Hold -Up Transmitter • 5881 ENHC - RF Receiver • 5883H - RF Receiver Access Control • VISTAKEY' V-Plex (addressable) Access Control • VISTAKEY-SK Starter Kit • VISTAKEY-EX Expansion Kit Alarm Communications • 7845i -ENT - Internet/Intranet Communicator • 7845GSM - Digital Cellular Communicator • 7845i -GSM - Internet and Digital Cellular Communicator • GSMCF/iGSMCF - Commercial Fire Communication Kits (when available) • IPGSM-DP Internet and Digital Cellular Communicator V128FBP-9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP9-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model For more information: www.honeywell.com/security Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com LNSTA128FBPD/D September 2012 2012 Honeywell International Inc.