Loading...
STRUCTURAL EVALUATIONEng. Number OAA711429_C2_01 September 5 2017 Page 1 of 2 A.T. Engineering Services, PLLC. 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office – 919-466-5414 Fax - www.americantower.com Structural Evaluation ATC Site Number & Name 21274, Spout Springs NC1, NC Carrier Site Number & Name RA54XC226 , RA54XC226 Site Location 2305 NC 87 South Sanford, NC 27332, Harnett County 35.27725278 N / 79.07086944 W Tower Description 320 ft Self Supported Tower Basic Wind Speed Basic Wind Speed w/ Ice Code 94 mph (3-Second Gust) 30 mph (3-Second Gust) w/ ¾” ice ANSI/TIA-222-G / 2009 IBC / 2012 North Carolina Building Code Existing and Reserved Equipment Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 320.0 328.0 1 Sinclair SC480 Side Arm (2) 7/8" Coax (1) 1/2" Coax (1) 1 5/8" Coax County Of Harnett 327.0 2 Andrew DB810K-XT 320.0 1 dbSpectra ATS7TMA30 303.0 313.0 1 Sinclair SC480 Side Arm (1) 1 5/8" Coax 294.0 297.0 6 RFS ATM192012-0 Sector Frame (2) 0.78" 8 AWG 6 (12) 2 1/4" Coax (1) 0.39" Fiber Trunk (1) 3/8" RET Control Cable AT&T Mobility 1 Raycap DC6-48-60-18-8F 3 Ericsson RRUS-11 800MHz 1 Kathrein 741-989 / AP16- 1940/088D/ADT/XP 3 Ericsson RRUS 32 B66 4 Kathrein 742 213 3 KMW EPBQ-652L8H8 270.0 270.0 3 Alcatel-Lucent 800 MHz 2X50W RRH w/ Filter Sector Frame (3) 1 1/4" Hybriflex Cable Sprint Nextel 3 Alcatel-Lucent 1900 MHz 4X45 RRH 3 Alcatel-Lucent TD-RRH8x20-25 w/ Solar Shield 3 RFS APXVSPP18-C 170.0 170.0 1 Andrew PL8·65 Leg (1) EW52 County Of Harnett Equipment to be Removed Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 270.0 270.0 3 Alcatel-Lucent 1900 MHz 4X45 RRH - - Sprint Nextel Eng. Number OAA711429_C2_01 September 5 2017 Page 2 of 2 A.T. Engineering Services, PLLC. 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office – 919-466-5414 Fax - www.americantower.com Proposed Equipment Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 270.0 270.0 3 RFS APXVTM14-ALU-I20 Sector Frame (1) 1 1/4" Hybriflex Cable Sprint Nextel 1 Mount elevation is defined as height above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna above grade level (AGL). Install proposed coax alongside existing Sprint Nextel coax. The existing and proposed loads listed in the tables above are compared to the tower’s current design capacity or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are found different from those listed in the tables. The subject tower and foundation are adequate to support the above stated loads in conformance with specified requirements. AAV/ANG