Loading...
ENG LETTER (3) 839217R Builders FirstSource (Albermarle,NC). December 31, 2017.My license renewal date for the state of North Carolina is North Carolina COA: C-0844 Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. Pages or sheets covered by this seal: Lot 687 Anderson Creek Club Gilbert, Eric The truss drawing(s) referenced below have been prepared by Truss Engineering Co. under my direct supervision based on the parameters provided by Re: thruE10848219E10848219 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdictions(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to Trenco. Any project specific information included is for Trenco’s customer’s file reference purpose only, and was not taken into account in the preparation of these designs. Trenco has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of the design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 818 Soundside Rd Edenton, NC 27932 Trenco August 16,2017 Job 839217R Truss F01 Truss Type Floor Qty 4 Ply 1 Lot 687 Anderson Creek Club Job Reference (optional) E10848219 7.640 s Apr 19 2016 MiTek Industries, Inc. Tue Aug 15 16:49:10 2017 Page 1 Builders FirstSource, Albemarle , NC 28001 ID:ER1xH3nLgw9XwTRqR3S8rtyyYKZ-p64XhMDeVwU9np_i1gHOxu18ZoBgY0hRSC9z94ynZ0t Scale = 1:47.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 31 30 29 28 27 26 25 24 23 22 21 20 19 18 32 3x8 MT20HS FP 3x6 1.5x3 1.5x3 3x8 MT20HS FP 3x10 MT20HS 3x4 3x4 3x4 3x4 1.5x3 1.5x3 3x6 3x4 4x5 3x4 4x5 3x4 3x4 1.5x3 1.5x3 2-9-0 2-9-0 9-1-8 6-4-8 11-9-0 2-7-8 11-9-4 0-0-4 14-4-8 2-7-4 16-10-8 2-6-0 22-1-4 5-2-12 24-7-4 2-6-0 27-4-4 2-9-0 1-3-0 1-1-8 1-2-12 0-1-8 1-2-01-2-0Plate Offsets (X,Y)-- [28:0-1-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 40.0 10.0 0.0 5.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.00 1.00 YES IRC2009/TPI2007 CSI. TC BC WB (Matrix) 0.76 0.74 0.53 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.17 -0.26 0.03 (loc) 20-21 20-21 18 l/defl >999 >719 n/a L/d 480 360 n/a PLATES MT20 MT20HS Weight: 138 lb FT = 20%F, 11%E GRIP 244/190 187/143 LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) *Except* 18-25: 2x4 SP No.1(flat) WEBS 2x4 SP No.3(flat) BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)31=455/Mechanical, 26=1813/0-3-8, 18=707/0-3-8 Max Grav 31=547(LC 3), 26=1813(LC 1), 18=739(LC 4) FORCES.(lb) - Maximum Compression/Maximum Tension TOP CHORD 1-31=-42/0, 18-32=-37/0, 17-32=-37/0, 1-2=0/0, 2-3=-990/6, 3-4=-1252/305, 4-5=-1252/305, 5-6=-1252/305, 6-7=-411/896 , 7-8=0/2022, 8-9=0/2022, 9-10=-437/370, 10-11=-437/370, 11-12=-1711/0, 12-13=-2273/0, 13-14=-2273/0, 14-15=-2257/0, 15-16=-1479/0, 16-17=-2/0 BOT CHORD 30-31=0/658, 29-30=-93/1272, 28-29=-305/1252, 27-28=-613/933, 26-27=-1184/0, 25-26=-806/0, 24-25=-806/0, 23-24=-124/1220, 22-23=0/2273, 21-22=0/2273, 20-21=0/2427, 19-20=0/2023, 18-19=0/910 WEBS 8-26=-99/0, 2-31=-825/0, 7-26=-1250/0, 2-30=-34/433, 7-27=0/829, 3-30=-367/113, 6-27=-836/0, 3-29=-391/0, 6-28=0/731 , 4-29=-15/133, 5-28=-309/0, 16-18=-1139/0, 9-26=-1525/0, 16-19=0/741, 9-24=0/1109, 15-19=-709/0, 11-24=-1066/0, 15-20=0/305, 11-23=0/694, 14-20=-222/24, 12-23=-831/0, 14-21=-444/95, 12-22=0/253, 13-21=-40/109 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) This truss has been designed for basic load combinations, which include cases with reductions for multiple concurrent live loads. 3) All plates are MT20 plates unless otherwise indicated. 4) All plates are 3x3 MT20 unless otherwise indicated. 5) Refer to girder(s) for truss to truss connections. 6) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 8) CAUTION, Do not erect truss backwards. 1-3-0 3-1/2" WIDE x 2" DEEP NOTCH CUT INTO TOP CHORD 4-0-0 ATTACH < 2 LAYERS > 3/4" PLYWOOD OR OSB GUSSET (23/32" RATED SHEATHING 48/24 EXP 1) TO ONE SIDE OF TRUSS WITH CONSTRUCTION QUALITY ADHESIVE AND ONE ROW OF (0.131" X 3.0") NAILS SPACED 2" O.C. FROM EACH FACE INTO EACH COVERED TRUSS MEMBER.GLUE PLYWOOD LAYERS TOGETHER PRIOR TO ATTACHING TO TRUSS. Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. 818 Soundside Road Edenton, NC 27932 August 16,2017 edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.