CO pitiSS'ISS. +4,,A.Istiti AlAigtiS,S,
COUNTY OF HARNETT .'
Building Inspections Department
Planning Services /
Certificate of Compliance: Occupancy: V
4 Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances.
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the i,
North Carolina State Building Codes. For the following'.
Use Classifcatio�nr. if Permit Numbers
11 Name: /I) U JAS /d/ n/t 17i� Building: //
Electrical:
r. AddrS<A /4-770—•
(
ess: o Ja !/l - Insulation: v
1) _ MPlechani �,
Mechanical: O4
MFG Home: 07
`i74.� .5
Date: 4- /1 - 17 Building Officialy��
PREPARFD 8/10/17, 14:33:17 INSPECTION TICKET PAGE 12
Harnett County INSPECTOR: IVR DATE 8/11/17
ADDRESS . : 88 SCHOLAR DR SUBDIV: ACADEMY@ACC PH 7 50LOTS
CONTRACTOR_: H & H CONSTRUCTORS INC PHONE : (910) 486-4864
OWNER . H CONSTRUCTORS INC PHONE :
PARCEL . . : 01-0535-25- -0100- -05-
APPL NUMBER: 16-50040262 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 11/29/2016 01:47 PM JBROCK ----
ANDERSON CREEK - ACADEMY LOT 1063
STRUCTURE: 000 000 36X66 4BDR SLAB W/ GARAGE & DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS • 4000000.00 PROPOSED USE ' SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY ' COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 12/19/16 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17 :00 VRU #: 00291199B
12/19/16 CA T/S: 12/16/2016 01:16 PM JBROCK
PER JOHN
B101 02 12/20/16 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 002912491
12/20/16 AP T/S: 12/19/2016 11:14 AM LBENNETT
A814 01 12/29/16 SB ADDRESS CONFIRMATION TIME: 17:00 VRU #: 002914901
12/29/16 AP 88 SCHOLAR DR SPRING LAKE 28390
T/S: 12/29/2016 08:14 AM SBENNETT
8103 01 12/29/16 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002914893
12/29/16 DA T/S: 12/28/2016 09:56 AM LBENNETT
REMOVE all dirt from top of footings inside & outside
foundation wall for inspection
8103 02 12/30/16 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17 :00 VRU #: 002915437
12/30/16 CA T/S: 12/29/2016 11:17 AM LBENNETT
PER JOHN
8103 03 1/03/17 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002915924
1/03/17 CA T/S: 12/30/2016 12:16 PM DJOHNSON
PER JOHN
B103 04 1/04/17 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002916229
1/04/17 AP T/S: 01/03/2017 11:12 AM LBENNETT
8105 01 1/17/17 JH R*OPEN FLOOR TIME: 17 :00 VRU #: 002920213
1/17/17 AP T/S: 01/13/2017 10:46 AM LBENNETT
B104 01 1/30/17 JB R*FOUND & SETBACK VERIF SURVEY TIME: 17:00 VRU #: 002926129
1/30/17 AP T/S: 01/30/2017 09:39 AM JBROCK
T/S: 01/30/2017 09:39 AM JBROCK
R425 01 2/09/17 TSG FOUR TRADE ROUGH IN TIME: 17 :00 VRU #: 002931012
2/09/17 DA T/S: 02/08/2017 12:23 PM DJOHNSON
T/S: 02/09/2017 04 :07 PM DJOHNSON
NO TRUSS PLANS AND I JOIST PLANS
R425 02 2/13/17 JH FOUR TRADE ROUGH IN TIME: 17 :00 VRU #: 002932218
2/13/17 DA T/S: 02/10/2017 10:34 AM JBROCK
1)Nail 3ply lvls in garage everyl2" per documents.2)Seal
all cracks in air barriers in garage under knee walls & on
house wall.3)Install back porch post 6x6 per
plans.4)Missing nails in roof truss hangers @ master
bedroom door.5)Flashing for back porch slab needs to be 4"
CONTINUED ONTO NEXT PAGE
PREPA14ED 8/10/17, 14 :33:17 INSPECTION TICKET PAGE 13
Harnett County INSPECTOR: IVR DATE 8/11/17
ADDRESS 88 SCHOLAR DR SUBDIV: ACADEMY@ACC PH 7 50L0TS
CONTRACTORr: H & H CONSTRUCTORS INC PHONE : (910) 486-4864
OWNER . . : H'k H CONSTRUCTORS INC PHONE :
PARCEL . . 01-0535-25- -0100- -05-
APPL NUMBER: 16-50040262 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
above slab & under house wrap.6)Need compaction letter for
back porch fill.7)Need 3-2x6s under 9 1/4" lvl on garage
wall in foyer.8)Add stud to left of door in spare bath
upstairs over 24" .9)MIssing baffels. 10)Need truss repair
letter for broke web on roof truss in loft.
OK TO SIDE GO NOT INSULATE
R425 03 2/16/17 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002933927
2/16/17 DA T/S: 02/15/2017 01:12 PM JBROCK
T/S: 02/16/2017 12 :53 PM MREARIC
still need compaction report on back porch, ok to insyulate
I129 01 2/20/17 KS R*INSULATION INSPECTION TIME: 17:00 VRU #: 002935104
2/20/17 AP T/S: 02/17/2017 02:32 PM LBENNETT
T/S: 02/20/2017 01:22 PM KSLATTUM
R425 04 2/20/17 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002935112
2/20/17 DA T/S: 02/17/2017 02 :33 PM LBENNETT
T/S: 02/20/2017 01:24 PM KSLATTUM
no letter for compaction. OK to sheetrock.
R425 05 3/28/17 KS FOUR TRADE ROUGH IN TIME: 17: 00 VRU # : 002950830
3/28/17 AP
E209 01 3/29/17 DT R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 002950848
3/29/17 DA T/S: 03/28/2017 09:35 AM JBROCK
T/S: 03/29/2017 12 :28 PM DETAYLOR
Electricians not finished
E209 02 3/30/17 DT R*ELEC TEMP POWER CERT TIME: 17 :00 FRU #: 002951952
3/30/17 AP T/S: 03/29/2017 03:08 PM LBENNETT
T/S: 03/30/2017 02:50 PM DETAYLOR
R429 01 7/27/17 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003004405
7/27/17 DA T/ : 07/26/2017 01:42 PM BPETRICH
)Missing window latches down stairs.2) Insulate attic door
in back bedroom closet.7(ICaulk windows to brick work.
R429 02 11/17 T FOUR TRADE FINAL TIME: 17:00 VRU #: 003010873
T/S: 08/10/2017 11:38 AM BPETRICH
COMMENTS AND NOTES