CO COUNTY OF HARNETT '4.;
1 Building Inspections Department
Planning Services
Certificate of Compliance: Occupancy: ✓
Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances. 4
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the ;I..e
North Carolina State Building Codes. For the following'.
Use Classification: ~NW
Permit Numbers .
Name: ~NW a a Building: /�
Il Electrical: S
Insulation: a
Address: Lor
Plumbing: �C l
Mechanical: 4
rbpMFG Home: f
Date: i/- ii_ Building Official�C",�, :7 7 I
PREPARED 8/10/17, 14:33 :17 INSPECTION TICKET PAGE 10
Harnett County INSPECTOR: IVR DATE 8/11/17
ADDRESS . : 76 SCHOLAR DR SUBDIV: ACADEMY@ACC PH 7 50LOTS
CONTRACTOR : H 'F H CONSTRUCTORS INC PHONE : (910) 486-4864
OWNER H & H CONSTRUCTORS INC PHONE :
PARCEL . : 01-0535-25- -0100- -04-
APPL NUMBER: 16-50040261 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 11/29/2016 01:47 PM JBROCK ----
ANDERSON CREEK - ACADEMY LOT 1062
STRUCTURE: 000 000 49X58 SBDR CRAWL W/ GARAGE & DECK
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS • 5000000.00 PROPOSED USE • SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 12/09/16 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17 :00 VRU #: 002908648
12/09/16 AP T-POLE PASSED
A814 01 12/16/16 SB ADDRESS CONFIRMATION TIME: 17 :00 VRU #: 002911410
12/16/16 AP 76 SCHOLAR DR SPRING LAKE 28390
T/S: 12/16/2016 08 :40 AM SBENNETT
8103 01 12/16/16 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002911402
12/16/16 DA T/S: 12/15/2016 11:02 AM LBENNETT
1)The center of the pier is to be in the cener 1/3 of the
footing 3 circled on plans
B103 02 12/19/16 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002912004
12/19/16 CA T/S: 12/16/2016 01:16 PM JBROCK
PER JOHN
B103 03 12/20/16 JH R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002912483
12/20/16 AP T/S: 12/19/2016 11:14 AM LBENNETT
B105 01 12/29/16 JH R*OPEN FLOOR TIME: 17:00 VRU #: 002914885
12/29/16 AP T/S: 12/28/2016 09:56 AM LBENNETT
B104 01 1/30/17 JB R+FOUND & SETBACK VERIF SURVEY TIME: 17:00 VRU #: 002926137
1/30/17 AP T/S: 01/30/2017 09:39 AM JBROCK
R425 01 2/01/17 JH FOUR TRADE ROUGH IN TIME: 17: 00 VRU #: 002927598
2/01/17 CA T/S: 01/31/2017 02:37 PM LBENNETT
PER JOHN
R425 02 2/03/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002928679
2/03/17 DP T/S: 02/02/2017 01:35 PM JBROCK
1)Seal all holes & cracks in air barriers in garage under
knee walls.2)Missing 3-2x66 to right of water heater in
garage per plans.3)Fire caulk wire @ top plate over sink in
half bath.4)Pack out Ijoist @ I joist hangers at
stairs.5)Fire caulk hole in bottom plate between master bed
& master bath door.6)Missing 3-2x6s to right of window in
family room per plans.7)Fire caulk hole in top plate over
fire place.8)Close gap in CO3 2ply trusses in laundry room
& front right bedroom.9)Fire caulk cable 0 top plate in
front right bed near door.10)Add studs on back wall of back
middle bed & back left corner of back left bedroom over
16" .11)Receptacle in front left bed on end wall over
12' .12)Missing truss bracing on trusses per truss documents.
13)Missing receptacle on back of house.
CONTINUED ONTO NEXT PAGE
. PREPARED 8/10/17, 14:33:17 INSPECTION TICKET PAGE 11
Harnett County INSPECTOR: IVR DATE 8/11/17
ADDRESS . : 76 SCHOLAR DR SUBDIV: ACADEMY®ACC PH 7 50LOTS
CONTRACTOR : H 4 H CONSTRUCTORS INC PHONE : (910) 486-4864
OWNER . . J• : H & H CONSTRUCTORS INC PHONE :
PARCEL . . : 01-0535-25- -0100- -04-
APPL NUMBER: 16-50040261 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
DO NOT INSULATE OK TO SIDE
R425 03 2/07/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002929859
2/07/17 DP T/S: 02/06/2017 10:52 AM DJOHNSON
ITEMS #1, 3,6, & 8 WERE NOT CORRECTED
R425 04 2/08/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002930543
2/08/17 AP T/S: 02/07/2017 01:38 PM LBENNETT
I129 01 2/14/17 MR R*INSULATION INSPECTION TIME: 17:00 VRU #: 002931814
2/14/17 AP T/S: 02/09/2017 01:32 PM JBROCK
T/S: 02/13/2017 08 :26 AM DJOHNSON
T/S: 02/14/2017 02 :18 PM MREARIC
There is NO insulation in bonus room Floor , per
contractor
R125 01 3/13/17 DT ONE TRADE ROUGH IN TIME: 17 :00 VRU #: 002944122
3/13/17 . AP T/S: 03/10/2017 01:28 PM JBROCK
stone inspection
T/S: 03/13/2017 04 :05 PM DETAYLOR
E209 01 3/29/17 DT R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 002950806
3/29/17 DA T/S: 03/28/2017 09:09 AM JHROCK
T/S: 03/29/2017 12 :28 PM DETAYLOR
Electricians not finished
E209 02 3/30/17 DT R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 002951945
3/30/17 AP T/S: 03/29/2017 03 :08 PM LBENNETT
T/S: 03/30/2017 02 :50 PM DETAYLOR
R429 01 7/27/17 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003004397
7/27/17 DA T/S: 07/26/2017 01:42 PM HPETRICH
"Lights in closet closer thanha12" to shelf.�Missing
window latches down stairsNeed light at AHU in
attic..)Remove wood from under house*Support water lines
& drain lines under house per code.
R429 02 y11/17 T OUR TRADE FINAL TIME: 17:00 VRU #: 003010865
T/S: 08/10/2017 11:38 AM HPETRICH
COMMENTS AND NOTES