Loading...
CO ofiaighSASSASSISAA haiii I. COUNTY OF HARNETT t Building Inspections Department Planning Services , Op Certificate of Compliance: Occupancy: 17 Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances. This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the '4.a North Carolina State Building Codes. For the following. p4. . Use Classification' i. Permit Numbers OA Name: /J} o1 ( I. J(/ ��7C-, Building: /��JJ Electrical: la� tt177 7 > Address: ) d S<4o /4/ /// _ Insulation: _..__ Plumbing: G�� 00 Mechanical: 0, n MFG Home: // ® Date: ki/j_ / 1 Building Official: ianiy --576‘,✓ €7r: 04, "' ° p' n'® !rs ' ,yid, ® revj ! PREPARED 8/10/17, 14:33:17 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 8/11/17 ADDRESS . : 32 SCHOLAR DR SUBDIV: ACADEMY@ACC PH 7 50LOTS CONTRACTOI H & H CONSTRUCTORS INC PHONE : (910) 486-4864 OWNER . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01-0535-25- -0100- -01- APPL NUMBER: 16-50040191 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 11/16/2016 09:53 AM LBENNETT -- HWY 27 TO NURSERY RD - TURN LEFT AND FOLLOW RAY RD- TURN LEFT AND FOLLOW TO ANDERSON CREEK DR STRUCTURE: 000 000 39X68 4BDR W/GARAGE SLAB FLOOD ZONE • FLOOD ZONE X # BEDROOMS - 4 .00 PROPOSED USE • SFD SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP • SPD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/23/16 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 002900959 11/23/16 AP T/S: 11/18/2016 01:05 PM LBENNETT NO T-POLE B103 01 11/30/16 MR R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002904332 11/30/16 AP T/S: 11/29/2016 12 :49 PM DJOHNSON tsp also T/S: 11/30/2016 02:16 PM MREARIC no t pole yet A814 01 12/08/16 SB ADDRESS CONFIRMATION TIME: 17 :00 VRU #: 002907855 12/08/16 AP 32 SCHOLAR DR SPRING LAKE 28390 T/S: 12/08/2016 02:48 PM SBENNETT E207 01 12/08/16 JH R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU #: 002907863 12/08/16 AP T/S: 12/07/2016 11:04 AM JBROCK T-POLE PASSED P309 01 12/14/16 JH R*PLUMB UNDER SLAB TIME: 17:00 VRU #: 002910339 12/14/16 AP T/S: 12/13/2016 10:28 AM LBENNETT Bill 01 12/16/16 JH R*BLDG SLAB INSP/TEMP SVC POLE TIME: 17 :00 VRU #: 002911394 12/16/16 AP T/S: 12/15/2016 11:02 AM LBENNETT B104 01 1/30/17 JB R*FOUND & SETBACK VERIF SURVEY TIME: 17 :00 VRU #: 002926178 1/30/17 AP T/S: 01/30/2017 09:40 AM JBROCK R425 01 1/30/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002925907 1/30/17 DP T/S: 01/27/2017 02:02 PM JBROCK 1) 3- studs each side of entry door in garage per plans.2)Missing nail guards @ bottom plate on water lines & 3" pipe at refrig & top plate in kitchen on half bath wa11.3)Fire caulk holes over fire box.4)Nail all 3ply lvls every 12" from each side per documents inkitchen & master bath.5)Missing nail guardsboth sides of water line @ master bath toilet .6)Missing stud under top plate joint in back left corner of master bedroom.7)Nail guard on 1 1/2" pipe @ top plate @ master bath sink.8) Strap ali4or more Scolumns throughout housemaster bath & upstairs on front walls of house @ girder trusses.9)Roof truss layout shows 3ply lvls from end wall in master bed to right side of laundry room wa11.10)Missing air barriers in chase in front left bedroom CONTINUED ONTO NEXT PAGE PREPARED 8/10/17, 14:33:17 INSPECTION TICKET PAGE 8 Harnett County INSPECTOR: IVR DATE 8/11/17 ADDRESS . : 32 SCHOLAR DR SUBDIV: ACADEMY@ACC PH 7 50L0TS CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486-4864 OWNEk . . : ANDERSON CREEK PARTNERS LP PHONE : PARCEL . . : 01-0535-25- -0100- -01- APPL NUMBER: 16-50040191 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS behind tub in spare bathroom & chase on back wall of upstairs bathroom.11)Nail air barrier in chase on end wall in spare bath upstairs.12) 3' head of water on drain line test.13) Fire caulk hole under tub in upstairs bathroom.14)Need truss documents for both 2ply trusse on front wall of house could not find. DO NOT INSULATE OK TO SIDE R425 02 2/01/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002927572 2/01/17 DP T/S: 01/31/2017 02 :28 PM LBENNETT ITEMS # 10,11 & 12 were not corrected R425 03 2/03/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU # : 002928661 2/03/17 AP T/S: 02/02/2017 01:35 PM JBROCK I129 01 2/08/17 JH R*INSULATION INSPECTION TIME: 17:00 VRU #: 002929834 2/08/17 AP T/S: 02/06/2017 10:46 AM DJOHNSON R125 01 3/13/17 DT ONE TRADE ROUGH IN TIME: 17:00 VRU #: 002944114 3/13/17 AP T/S: 03/10/2017 01:27 PM JBROCK stone inspection T/S: 03/13/2017 04:05 PM DETAYLOR E209 01 3/22/17 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 002947489 3/22/17 AP T/S: 03/21/2017 10:03 AM JBROCK R429 01 7/26/17 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003003324 7/26/17 DA T/S: 07/25/2017 12:26 PM LLUCAS Light in master closet is closer than 12" to shelf R429 02 /11/17 TI FOUR TRADE FINAL TIME: 17:00 VRU #: 003010840 T/S: 08/10/2017 11:37 AM BPETRICH COMMENTS AND NOTES