CO ofiaighSASSASSISAA haiii I.
COUNTY OF HARNETT
t Building Inspections Department
Planning Services ,
Op Certificate of Compliance: Occupancy: 17
Certificate issued pursuant to the requirements of North Carolina General Statute 153A-363 and Harnett County Zoning Ordinances.
This certifies at the time of issuance,this structure was in compliance with the various ordinances of the County of Harnett and the '4.a
North Carolina State Building Codes. For the following.
p4. .
Use Classification' i. Permit Numbers
OA Name: /J} o1 ( I. J(/ ��7C-, Building: /��JJ Electrical: la�
tt177 7 >
Address: ) d S<4o /4/ /// _ Insulation:
_..__ Plumbing: G��
00
Mechanical: 0,
n MFG Home: // ®
Date: ki/j_ / 1 Building Official: ianiy --576‘,✓ €7r:
04,
"' ° p' n'® !rs ' ,yid, ® revj !
PREPARED 8/10/17, 14:33:17 INSPECTION TICKET PAGE 7
Harnett County INSPECTOR: IVR DATE 8/11/17
ADDRESS . : 32 SCHOLAR DR SUBDIV: ACADEMY@ACC PH 7 50LOTS
CONTRACTOI H & H CONSTRUCTORS INC PHONE : (910) 486-4864
OWNER . . : ANDERSON CREEK PARTNERS LP PHONE :
PARCEL . . : 01-0535-25- -0100- -01-
APPL NUMBER: 16-50040191 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 11/16/2016 09:53 AM LBENNETT --
HWY 27 TO NURSERY RD - TURN LEFT AND
FOLLOW RAY RD- TURN LEFT AND FOLLOW TO
ANDERSON CREEK DR
STRUCTURE: 000 000 39X68 4BDR W/GARAGE SLAB
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS - 4 .00 PROPOSED USE • SFD
SEPTIC - EXISTING' • SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP • SPD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 11/23/16 JH R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU #: 002900959
11/23/16 AP T/S: 11/18/2016 01:05 PM LBENNETT
NO T-POLE
B103 01 11/30/16 MR R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002904332
11/30/16 AP T/S: 11/29/2016 12 :49 PM DJOHNSON
tsp also
T/S: 11/30/2016 02:16 PM MREARIC
no t pole yet
A814 01 12/08/16 SB ADDRESS CONFIRMATION TIME: 17 :00 VRU #: 002907855
12/08/16 AP 32 SCHOLAR DR SPRING LAKE 28390
T/S: 12/08/2016 02:48 PM SBENNETT
E207 01 12/08/16 JH R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU #: 002907863
12/08/16 AP T/S: 12/07/2016 11:04 AM JBROCK
T-POLE PASSED
P309 01 12/14/16 JH R*PLUMB UNDER SLAB TIME: 17:00 VRU #: 002910339
12/14/16 AP T/S: 12/13/2016 10:28 AM LBENNETT
Bill 01 12/16/16 JH R*BLDG SLAB INSP/TEMP SVC POLE TIME: 17 :00 VRU #: 002911394
12/16/16 AP T/S: 12/15/2016 11:02 AM LBENNETT
B104 01 1/30/17 JB R*FOUND & SETBACK VERIF SURVEY TIME: 17 :00 VRU #: 002926178
1/30/17 AP T/S: 01/30/2017 09:40 AM JBROCK
R425 01 1/30/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002925907
1/30/17 DP T/S: 01/27/2017 02:02 PM JBROCK
1) 3- studs each side of entry door in garage per
plans.2)Missing nail guards @ bottom plate on water lines &
3" pipe at refrig & top plate in kitchen on half bath
wa11.3)Fire caulk holes over fire box.4)Nail all 3ply lvls
every 12" from each side per documents inkitchen & master
bath.5)Missing nail guardsboth sides of water line @ master
bath toilet .6)Missing stud under top plate joint in back
left corner of master bedroom.7)Nail guard on 1 1/2" pipe @
top plate @ master bath sink.8) Strap ali4or more Scolumns
throughout housemaster bath & upstairs on front walls of
house @ girder trusses.9)Roof truss layout shows 3ply lvls
from end wall in master bed to right side of laundry room
wa11.10)Missing air barriers in chase in front left bedroom
CONTINUED ONTO NEXT PAGE
PREPARED 8/10/17, 14:33:17 INSPECTION TICKET PAGE 8
Harnett County INSPECTOR: IVR DATE 8/11/17
ADDRESS . : 32 SCHOLAR DR SUBDIV: ACADEMY@ACC PH 7 50L0TS
CONTRACTOR : H & H CONSTRUCTORS INC PHONE : (910) 486-4864
OWNEk . . : ANDERSON CREEK PARTNERS LP PHONE :
PARCEL . . : 01-0535-25- -0100- -01-
APPL NUMBER: 16-50040191 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
behind tub in spare bathroom & chase on back wall of
upstairs bathroom.11)Nail air barrier in chase on end wall
in spare bath upstairs.12) 3' head of water on drain line
test.13) Fire caulk hole under tub in upstairs
bathroom.14)Need truss documents for both 2ply trusse on
front wall of house could not find.
DO NOT INSULATE OK TO SIDE
R425 02 2/01/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002927572
2/01/17 DP T/S: 01/31/2017 02 :28 PM LBENNETT
ITEMS # 10,11 & 12 were not corrected
R425 03 2/03/17 JH FOUR TRADE ROUGH IN TIME: 17:00 VRU # : 002928661
2/03/17 AP T/S: 02/02/2017 01:35 PM JBROCK
I129 01 2/08/17 JH R*INSULATION INSPECTION TIME: 17:00 VRU #: 002929834
2/08/17 AP T/S: 02/06/2017 10:46 AM DJOHNSON
R125 01 3/13/17 DT ONE TRADE ROUGH IN TIME: 17:00 VRU #: 002944114
3/13/17 AP T/S: 03/10/2017 01:27 PM JBROCK
stone inspection
T/S: 03/13/2017 04:05 PM DETAYLOR
E209 01 3/22/17 JH R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 002947489
3/22/17 AP T/S: 03/21/2017 10:03 AM JBROCK
R429 01 7/26/17 JH FOUR TRADE FINAL TIME: 17:00 VRU #: 003003324
7/26/17 DA T/S: 07/25/2017 12:26 PM LLUCAS
Light in master closet is closer than 12" to shelf
R429 02 /11/17 TI FOUR TRADE FINAL TIME: 17:00 VRU #: 003010840
T/S: 08/10/2017 11:37 AM BPETRICH
COMMENTS AND NOTES