CO se
i *sly((hx a_f(RYrvi nil„to nodi IU: , r ( „ it tl :
COUNTY OF HARNETT kt,y
,t.. Building Inspections Department
Planning Services
Certificate of Compliance: Occupancy:
Certificate issued pursuant to the requirements of North Carolina General Statute 153A-3fi3 end Harnett County Zoning Ordinances. 3
This certifies at the time of Issuance,this structure was in compliance with the various ordinances of the County of Harnett and the - ,d
North Carolina State Building il. Codes For For the following. „W
Use Classification:.Sf/ Permit Numbers
Name:5 ?oJc0 <a Ct ?/i Si/sem, f p--+ .fU Building: 44
4 Electrical:
Address: �� /"fir ��� 51"C��7 Z. °-il)
Plumbion ?1/41..
i•/
ng.—
. . _ Mechanical: y4
�} __ MFG Home: c_.,Date: 6 '�j 7 Budding Official: �J. � ;I.,
m,�
G' .myi
PREPARbD 8/14/17, 14 :34 :45 INSPECTION TICKET ' PAGE 3
Harnett County INSPECTOR: IVR DATE 8/15/17
ADDRESS . : 114 MEADOW SPRING LN SUBDIV: CAROLINA LAKES
CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864-0247
OWNER . . : SHOWCASE CONSTRUCTION COMPANY PHONE
PARCEL . . : 03-9585-04- -0057- - -
APPL NUMBER: 16-50038926 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : T/S: 06/08/2016 10:34 AM LBENNETT --
114 MEADOW SPRING LANE
CAROLINA LAKES - LOT#57
STRUCTURE: 000 000 42X49 4BDR W/GARAGE STEM WALL
FLOOD ZONE • FLOOD ZONE X
# BEDROOMS 4.00 PROPOSED USE • SFD
SEPTIC - EXISTING' - SEWER WATER SUPPLY • COUNTY
PERMIT: CPSF 00 CP • SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
8101 01 8/17/16 MR R*BLDG FOOTING / TEMP SVC POLE TIME: 17 :00 VRU #: 002858454
8/17/16 AP T/S: 08/16/2016 12:19 PM DJOHNSON
TSP INSPECTION ALSO
T/S: 08/17/2016 02:19 PM MREARIC
A814 01 9/02/16 SB ADDRESS CONFIRMATION TIME: 17 :00 VRU #: 002865772
9/02/16 AP 114 MEADOW SPRING LN SANFORD 27332
T/S: 09/02/2016 09:05 AM SBENNETT
8103 01 9/02/16 MR R+BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002865764
9/02/16 DA T/S: 09/01/2016 09:03 AM DJOHNSON
T/S: 09/02/2016 01:58 PM MREARIC
install foundation insulation or provide a Res-check
8103 02 9/27/16 MR R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002876811
9/27/16 DA T/S: 09/26/2016 09:33 AM JFORBES
T/S: 09/27/2016 02:45 PM MREARIC
1. all drain lines through footers must be sleeved
2 . all drain lines must be wrapped at vertical penetrations
3 . clean off footers for foundation inspection
P309 01 9/27/16 MR R*PLUMB UNDER SLAB TIME: 17:00 VRU #: 002876829
9/27/16 DA T/S: 09/26/2016 09:35 AM JFORBES
T/S: 09/27/2016 02:45 PM MREARIC
1. all drain lines through footers must be sleeved
2. all drain lines must be wrapped at vertical penetrations
3. clean off footers for foundation inspection
B103 03 9/29/16 TSG R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU #: 002878692
9/29/16 AP T/S: 09/28/2016 01:12 PM JBROCK
P309 02 9/29/16 TSG R*PLUMB UNDER SLAB TIME: 17:00 VRU #: 002878718
9/29/16 AP T/S: 09/28/2016 01:12 PM JBROCK
B104 01 10/07/16 TI R*FOUND & SETBACK VERIF SURVEY TIME: 17 :00 VRU #: 002883007
10/07/16 AP T/S: 10/07/2016 04 :25 PM LBENNETT
T/S: 10/07/2016 04:25 PM LBENNETT
8111 01 10/10/16 MR R*BLDG SLAB INSP/TEMP SVC POLE TIME: 17 :00 VRU #: 002881803
10/12/16 DA T/S: 10/05/2016 02:53 PM DJOHNSON
CUSTOMER ASKED FOR A SLAB PREP INSPECTION
T/S: 10/07/2016 08:22 AM JFORBES
T/S: 10/12/2016 01:24 PM MREARIC
need plastic under garage
R425 01 10/11/16 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002883015
10/12/16 DA T/S: 10/07/2016 04 :25 PM LBENNETT
CONTINUED ONTO NEXT PAGE
PREPARE) 8/14/17, 14 :34 :45 INSPECTION TICKET PAGE 4
Harnett County INSPECTOR: IVR DATE 8/15/17
ADDRESS . : 114 MEADOW SPRING LN SUBDIV: CAROLINA LAKES
CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864-0247
OWNER . . : SHOWCASE CONSTRUCTION COMPANY PHONE :
PARCEL . . : 03-9585-04- -0057- - -
APPL NUMBER: 16-50038926 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
T/S: 10/12/2016 01:27 PM MREARIC
wrong inspection
B10S 01 10/20/16 MR R*OPEN FLOOR VRU #: 002886988
10/20/16 DA T/S: 10/20/2016 01:46 PM MREARIC
T/S: 10/20/2016 01:48 PM MREARIC
this should have been a slab inspection. the slab passed
yesterday, so its OK to pour.
R425 02 1/19/17 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002920536
1/19/17 DP T/S: 01/13/2017 02:43 PM JBROCK
T/5: 01/18/2017 09:16 AM LBENNETT
T/S: 01/19/2017 10:55 AM MREARIC
1.strap garage door LVL per code
2 . mid-strap all supporting columns
3 . 8' FB at front door must be screwed per specs
4 . t-ply at fireplace vent is too close to vent
5. fireblock above fireplace
6. finish all plumbing and install tests
7. why is siding installed. remove siding at one window to
check for flashing
8. build chase around A/C duct on 2nd floor
9. seal all floor penetrations at tubs and showers, etc.
10. remove all #10 short nails at toe-nail applications and
replace with correct nails
R425 03 1/27/17 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002924645
1/27/17 CA T/S: 01/25/2017 02 :47 PM DJOHNSON
T/S: 01/27/2017 12 :22 PM MREARIC
R425 04 2/22/17 DT FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002935534
2/22/17 CA T/S: 02/20/2017 01:36 PM JBROCK
T/S: 02/21/2017 08:01 AM LBENNETT
T/S: 02/22/2017 03:36 PM DETAYLOR
Per superindentent
STAIRS DO NOT HAVE 80 INCHES HEADROOM
R425 05 2/28/17 TSG FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002938496
2/28/17 DP T/S: 02/27/2017 12 :24 PM BPETRICH
Iteam 1 and 10 from previous inspection not repaired .
Remove 1 1/2 teco nails and 2 1/2 sinkers from all roof and
floor truss hanger and install required 10 D common nails.
2-water test has leaked down on supply .Drain test ok
R425 06 3/06/17 TSG FOUR TRADE ROUGH IN TIME: 17:00 VRU #: 002940864
3/06/17 AP T/S: 03/03/2017 01:38 PM JBROCK
I129 01 3/09/17 TSG R*INSULATION INSPECTION VRU #: 002942392
3/09/17 AP
M305 01 6/20/17 SLP R*PLUMB SEWER CONNECTION TIME: 17:00 VRU #: 002986362
6/20/17 AP T/S: 06/19/2017 08:16 AM BPETRICH
T/S: 06/20/2017 11:51 AM JPERRY
E209 01 8/01/17 TSG R*ELEC TEMP POWER CERT TIME: 17:00 VRU #: 003007200
8/01/17 AP T/S: 08/02/2017 09:18 AM BPETRICH
CONTINUED ONTO NEXT PAGE
PREPAR&U 8/14/17, 14:34:45 INSPECTION TICKET PAGE 5
Harnett County INSPECTOR: IVR DATE 8/15/17
ADDRESS . : 114 MEADOW SPRING LN SUBDIV: CAROLINA LAKES
CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE : (910) 864-0247
OWNER : SHOWCASE CONSTRUCTION COMPANY PHONE :
PARCEL . : 03-9585-04- -0057- - -
APPL NUMBER: 16-50038926 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
T/S: 08/02/2017 09:18 AM BPETRICH
R429 01 8/01/17 TSG FOUR TRADE FINAL TIME: 17:00 VRU It: 003005808
8/01/17 DA T/S: 07/31/2017 09:20 AM BPETRICH
final not ready issued cond power
R429 02 8/11/17 TSG FOUR TRADE FINAL TIME: 17:00 VRU It: 003010956
8/10/17 DA T/S: 08/10/2017 01:45 PM SBROCK
Y9BATHS REQUIRE DOOR LOCKS 2?SEVERAL CHILD LOCKS BROKEN
6-CAULK TOILETS )-WEATHER STRIP MISSING ON SCUTTLE
6-CAULK/SEAL BATH TOPS
R429 03 15 17T FOUR TRADE FINAL TIME: 17:00 VRU It: 003012390
�6 1!7 / ( T/S: 08/14/2017 01:58 PM BPETRICH
COMMENTS AND NOTES