Loading...
INSPECTION WITH ENG LETTER (2) PREPARED 8/14/17, 14 :34 :45 INSPECTION TICKET PAGE 27 Harnett County INSPECTOR: IVR DATE 8/15/17 ADDRESS . : 94436 *UNASSIGNED SUBDIV: ROLLING SPRINGS CONTRACTOR : WELLCO CONTRACTORS, INC. PHONE : (910) 436-3131 OWNER : WELLCO CONTRACTORS INC PHONE : (910) 436-3131 PARCEL . . : 01-0506- - -0068- -10- APPL NUMBER: 17-50040805 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 02/22/2017 04:38 PM JBROCK ---- ROLLING SPRINGS LOT#69 OFF NURSERY RD 04/04/2017 02:57 PM TJONES ---- STRUCTURE: 000 000 35X39 3BDR SLAB A/ GARAGE & DECK FLOOD ZONE • FLOOD ZONE X # BEDROOMS • 3000000.00 PROPOSED USE • SFD SEPTIC - EXISTING' • NEW TANK WATER SUPPLY • COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS A814 01 4/04/17 SB ADDRESS CONFIRMATION TIME: 17 :00 VRU #: 002954394 4/04/17 AP 151 MAGNOLIA DR SPRING LAKE 28390 T/S: 04/04/2017 11:27 AM SBENNETT 8101 01 8/10/17 JH R*BLDG FOOTING / TEMP SVC POLE VRU #: 003010217 8/10/17 AP PER ENGINEER LETTER A814 02 8/15/17 TI � ADDRESS CONFIRMATION VRU #: 003012199 B103 01 15/ 7 T R*BLDG FOUND & TEMP SVC POLE VRU #: 003010930 COMMENTS AND NOTES Geotechnical Engineering Services Construction Material Civil Quality Control Wellco Contractors 08/10/2017 P 0 Box 766 Spring Lake, NC 28390 Attention :Jason Wellons RE: Daily Field Report for 07/26/2017 Lot 69 Hidden Lakes (CMT)Spring Lake, NC Building & Earth Project No : RD170303 Ladies and Gentlemen: On this date, representative(s) of Building & Earth were present to perform construction material testing services at this project site. Our testing and observations for this date include the following: FO-3 : Field Observations made on this date. • Project Management Review Passed ST-3 : In place field density testing was performed for Finished Subgrade Soils -Building. The field density testing was performed in general accordance with ASTMD6938, using values from the laboratory proctors. One(1) in-place field density test was performed on this date. The testing results indicate that in-place compaction and moisture content at the location and depth tested meet or exceed the specified requirements outlined in the project plans and specifications. For additional details of our testing, please refer to the attached Field Density Test Report. Closing The testing and observations identified above have been reviewed by our project manager. If you have questions regarding this information, please do not hesitate to contact us. Respectfully Submitted, Building & Earth Sciences, LLP Enclosures : FO-3, ST-3 ,,,,,,,,,, ,, (N •- ARD ". 2; Q `024 \‘ 2( 610 Spring Branch Road F. �`• Dunn,NC 28334 •;:!\Ne, rG,• Ath /) '/ /, Phone 910-292-2085 Fax 910-292-2192 RT A. Mo- ,,, t �/ 94 t WNW Btaltl,ngandEarth coin ,V,Op,„,,,,, Reviewed By Page 1 of 3 07/26/2017 Field Observations Report Project Name: Lot 69 Hidden Lakes(CMT)Spring Lake.NC Project Number: RD170303 Client Name: Weitco Contractors Placements: FO-3 Contractor: Technician: James Johnson Monitoring: 1 : Project Management Review Passed On this date,our representatives returned to the site for re-testing. Based upon our re-testing, the recommended repairs have been accomplished,and the building pad is now acceptable for the construction of the foundations. Additionally,inclement weather(rain or snow),as wed as construction traffic across the pad,can compromise the stability and support characteristics of the surface soils. If the surface soils become compromised, it will be necessary to return to the site for re-testing. This decision should be executed by your onsite Quality Control and Superintendents. 610 Spring Branch Road r 0unn.NC 28334 !r' n-t�� // • Phone 910-192-2085 Fax 910-291-1191 f/ www.BwldmgandEanhcorn Reviewed By Page 2 of 3