IPACHTE# I I- 5-`Ilti3o
1 c (Repair)
Harnett County Department of Public Health
29597
Septic Tank Size L ofSo gallons
Exact length of each trench 10 p feet
Improvement Permit
Trenches shall be installed on contour at a
Maximum Trench Depth of: 30 inches
A building permit cannot be issued with only an Improvement Permit
(Trench bottoms shall be level to +/_I/4"
ISSUED TO:
PROPERTY LOCATION: 183 22$4;5 W"11 c a 'A
9 Qc>bin Sots 1� o U C.. SUBDIVISION
(Srt. ZOZ�)
GPM
NEW
EPAIR ❑
LOT #
EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance:
Type of Structure: 3tb2 ,Su'xG1
5 Ft'�,
Proposed Wastewater System Type:z55�L',,^ 4 _
Projected Daily Flow:
3 &C0
GPD
Number of bedrooms:
3 —
Number of Occupants: mag
Basement ❑Yes
C�b
Pump Required: ❑Yes
❑ No
_�
y berequired based on final location and elevations of facilities
Type of Water Supply:
❑ Community
—MMaf�
11 Public ❑ Well Distance from well feet Permit valid for.
,�
i�lF ve years
Permit conditions:
❑ No expiration
Authorized State Agent:: Date: U 7-,u "4 SEE ATTACHED SITE SKETCH
The issuance of this permit by the Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This
site is subject to Reno on if the site plan, plat. or the intended use changes. The Improvement permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of
the laws and Rules for Sewage Treatment and Disposal and to conditions of this permit..
Construction Authorization
Required for Building Permjt)
The construction and installation requirements of Rules .1950, .1957, .1954, .1955, .1956, .1957, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance
with the attached system IayouL
ISSUED TO: GLx+) (10tu; nSCy\ Eloncps, lZC. PROPERTY LOCATION: 12-33 TOsed LJdll;y"ay r2<s,. ( S.-+ azo)
SUBDIVISION LOT #
Facility Type: 315 �Fiyk 7e St`tZ_ Q-jew ❑ Expansion ❑ Repair
Basement? ❑ Yes 9-1fo— Basement Fixtures? ❑ Yes ❑ No
Type of Wastewater System*' —Zs�(Initial) Wastewater Flow: 360 GPD
(See note below, if applicable ❑)
Z�i`>
1 c (Repair)
Installation Requirements/Condition:
Number of trenches �a_
Septic Tank Size L ofSo gallons
Exact length of each trench 10 p feet
Pump Tank Size gallons
Trenches shall be installed on contour at a
Maximum Trench Depth of: 30 inches
(Trench bottoms shall be level to +/_I/4"
in all directions)
Pump Requirements: it. TDH vs.
GPM
Conditions:
Trench Spacing: _� Feet on Center
Soil Cover: I `i3 inches
(Maximum soil cover shall not exceed
36" above the trench bottom)
— inches below pipe
Aggregate Depth: a inches above pipe
WATER LINES (INCLUDING IRRIGATION) MUST BE ]OFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA.
NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA.
12 inches total
If a livable: / understand the systemtype specified is different from the type specified an the app/icatian. / aae I, the rpecihiationr of thi permit.
Owner/Legal Representative Signature: Date:
This construction Autbomation is subject to revocation if the site plan, plat, or the intended use changes. The Consfmcdon Authori:atian shall not be transferred when there is a change in ownership of the site. This
s.mnamucaon numonzanon is subject to Compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and m the conditions of this permit SEE ATTACHED SITE SKETCH
Authorized State Agent: Date: o&(tl /"'17
Construction Authorization Expiration Date: c-"Ild r-OR9
HTE# ' S — qEy30 Permit # a ci Scc :7
Harnett County Department of Public Health
Site Sketch
PROPERTY LOEATON: CU-- Cs(t r1a�
ISSUED TO: %c" SUBDIVISION LOT #
Authorized State Agent Date: O q�' / j I
RIN
M C -VA t— i
CX
+Slt>
GoVK2
1
Ic;P 1
9,0
, 0e05Ep1
X6�
r �
N1
� 0
N
�
� r
N�
V
N
t ss
avSF,y WILLIgens UI'> C-Srz- 80,Aa"l
Department of Environment, Health and Natural Resources
Division of Environmental Health
On -Site Wastewater Section
SOIL/SITE EVALUATION
for ON-SITE WASTEWATER SYSTEM
Owner: Applicant: 6wj or b&' "
Address: IZ33'%�j reef/i:.� 'G!. Date Evaluated:
Proposed Facility: Design Flow (.1949): AV 0_6
Location of Site: 3o/& Sr Property Recorded: !'�1
Water Supply: ❑'15ablic❑ Individual ❑ Well
Evaluation Method: Auger Bo ❑ Pit ❑ Cut
Type of Wastewater: Er Sewage ❑ Industrial Process
Sheet:
Property ID:
Lot #:
File #:
Code:
Property Size: •S, �;S y�G
❑ Spring ❑ Other
❑ Mixed
P
R
O
F
1
.1940
SOIL MORPHOLOGY
.1941
OTHER
PROFILE FACTORS
L
E
#
Landscape
Position/
Slope%
Horizon
Depth
(In.)
.1941
Structure/
Texture
.1941
Consistence
Mineralogy
1942
Soil
Wetness/
Color
.1943
Soil
Depth (IN.)
.1956
Sapro
Class
.1944
Restr
Horiz
Profile
Class
& LTAR
L 4r/v
0-3Z
Vr4*1/3,
2
L Ijv
O -ZZ
6,f t,5
At f�
ZZ-'%
S
✓et rte° �Vy
0-7,9
art cs
vFrZ �ff°�-s
Z�l'7S
SG S
✓p r r
�!$
G
0'6
Description Initial Repair System Other Factors (.1946): /
System j Site Classification (.1948): P/6✓Ar~&
Available Space(. 1945) Evaluated By:
S temT e(s) Z3 u 'v OthetsPresent: Ah�re� L.cxr:n11�`%�
Site LTAR O , Wf