Loading...
ENG LETTER 8/6/17 • DAVID MILLER, PE 6300 Creedmoor Rd,STE 170#363 Raleigh, NC 27612 (919)422-8932(Office); DAVE@DMA-PA.COM August 6,2017 Amy McMillan 36 Prestige Drive Cameron,NC E-mailed to:omy.mcmillan79@gmail.com Amy McMillan 910-978-1859 RE:Engineering-Structural 36 Prestige Drive Cameron,NC Project No.:17DDM-0805D To Whom It May Concern/Inspections Dept.: The undersigned arrived on-site 8-5-17 to observe,review and analyzed the following for the above referenced site. The(2)2X10 header 46 inches long was analyzed for the second floor loading conditions. Based on the analysis the(2)2X10 is adequate to transfer and support the loading conditions.A 2X4 jack and 2X4 king stud is required to transfer the reaction load from the header.Based on the soundings and observations the framing is adequate to support the 11ft I1in and 14ft llin second floor loading. The rear exterior wall was observed along with photographs and soundings for the replaced header((2)2X10 on(3)2X4 jacks and one king stud each end)for the roof loading of approximately 15 feet and the second floor loading of approximately 14ft 11 in and based on the loading conditions the(2)2X10 on(3)2X4 jacks and one king stud each end is adequate to transfer and support the loading conditions. Sincerely, David Miller,PE DEM/17DDM-0805D ``011111Hk_� 000beioMd by CARDI AED02e134115FIGc._ M. WO i 18/6/2017 • • k/till 111oo" 11 5 664F r '