Loading...
C3_Site PlanWOOD E D WOOD E D WOOD E D PERMIT DRAWING - NOT RELEASED FOR CONSTRUCTION SEAL PROJECT 60 1 - A W E S T M A I N S T : : C A R R B O R O , N C 2 7 5 1 0 5432 A B C D 1 6 7 8 90 54321 6 7 8 90 A B C D E F G E F G H 10 10 A B C D E F G H CONSULTANT CHECKED BY: DRAWN BY: DATE: PL T S T A M P 32 5 0 O C E A N P A R K B L V D : : S U I T E 3 5 5 : : S A N T A M O N I C A , C A 9 0 4 0 5 BE R A R D U C C I 3/ 2 5 / 2 0 1 6 3 : 5 0 P M PE A C H _ C O N S T R U C T I O N P L A N _ 1 2 - 1 6 - 1 5 . D W G SEAL RE V I S I O N S DA T E DE S C R I P T I O N NO . NORTH N GRAPHIC SCALE 50'0 50' 1" = 50' LEGEND EXISTING CONDITIONS BUILDING SETBACK OVERHEAD ELECTRICAL TREELINE MAJOR CONTOURS MINOR CONTOURS PROPERTY (ADJOINER) RIGHT-OF-WAY STREET CENTERLINE PROPOSED CONDITIONS LIMIT OF DISTURBANCE OVERHEAD ELECTRICAL PROJECT AREA PROPERTY LINE SECURITY FENCE TREELINE PROPOSED SITE ENTRANCE EXISTING VEGETATION TO REMAIN FOR BUFFER (SEE SHEET C5) EXISTING SITE BOUNDARY APPROXIMATE PROJECT ARRAY AREA CONTAINED WITHIN PROPOSED FENCE LINE (13.5 AC) SITE LOCATION NC 27 W WEST F R O N T S T . S M A I N S T . VICINITY MAP SCALE 1" = 5000' N U S 4 0 1 NC 2 1 0 CA P E FE A R 6' TALL SECURITY FENCE WITH 3 STRANDS OF BARBED WIRE (TYP.) N/F GREGORY M. FILYO BOOK 765, PAGE 415 PIN: 0538-48-7908.000 N/F LESLIE STRICKLAND BOOK 940, PAGE 811 PIN: 0538-59-5338.000 N/F CHRISTOPHER WADE DEAN BOOK 650, PAGE 916 PIN:0538-48-6727.000 N/F J. E. WOMBLE & SONS BOOK 2005, PAGE 237 PIN:0538-69-0237.000 EQUIPMENT PAD UNDERGROUND ELECTRICAL ARRAY AREA (TYP.) EQUIPMENT PAD (TYP.) UNDERGROUND ELECTRIC LINE (TYP.) EXISTING 25' REAR YARD SETBACK POINT OF INTERCONNECTION (SEE INSET THIS SHEET) PROPOSED UTILITY POLE (TYP) EXISTING MATURE VEGETATION EXISTING UTILITY POLE PROPOSED TEMPORARY LAYDOWN AREA ARRAY 1 176 STRINGS UTILITY POLE WITH METER & RECLOSER UTILITY POLE WITH DISCONNECT POINT OF INTERCONNECTION CUSTOMER POLE WITH GOAB SWITCH CUSTOMER POLE WITH METER CUSTOMER POLE WITH FUSED CUTOUTS OVERHEAD TO UNDERGROUND TRANSITION ARRAY 2 174 STRINGS ARRAY 4 174 STRINGS ARRAY 3 176 STRINGS EXISTING 25' SIDE YARD SETBACK PER HARNETT COUNTY ORD 8.1.2B (TYP.) EXISTING 35' FRONT YARD SETBACK FROM R/W (TYP.) GENERAL ZONING NOTES 1.THE PURPOSE OF THIS SITE PLAN IS TO DEPICT THE LAYOUT OF THE SOLAR COLLECTOR FACILITY, ITS INTERCONNECTION TO THE EXISTING POWER INFRASTRUCTURE, AND TO OBTAIN A CONDITIONAL USE PERMIT FOR THE USE. REVIEW AND APPROVAL BY THE ZONING ADMINISTRATOR OF MINOR MODIFICATIONS TO THE SITE PLAN ARE REQUESTED IN REGARDS TO THE LOCATIONS AND QUANTITY OF RACKING, NUMBER AND LOCATION OF INVERTERS, ACCESS AISLES, DRIVEWAYS, AND UNDERGROUND ELECTRIC INTERCONNECTION ROUTING UPON THE COMPLETION OF FINAL ENGINEERING DRAWINGS FOR THE FACILITY. HOWEVER, ALL SUCH MINOR MODIFICATIONS TO THE FINAL SITE PLAN SHALL COMPLY WITH ALL APPLICABLE SECTIONS OF THE HARNETT COUNTY ZONING ORDINANCE AND VERIFIED BY THE HARNETT COUNTY ZONING ADMINISTRATOR PRIOR TO ISSUING A ZONING PERMIT FOR USE AND CONSTRUCTION. 2.ON JANUARY 12, 2015, THE HARNETT COUNTY BOARD OF ADJUSTMENT APPROVED A CONDITIONAL USE PERMIT # BA-CU-04-15 WITH THE FOLLOWING CONDITIONS: ·SUBMIT DECOMMISSION PLAN TO RESTORE LAND BACK TO ORIGINAL USE. ·USE BERMS AND TREES IN ADDITION TO BARBWIRE FENCE TO BUFFER VISIBILITY OF BARBWIRE. 3.THE PROPERTY SHOWN HEREON DOES NOT CONTAIN SPECIAL FLOOD HAZARD AREAS (SFHAS) SUBJECT TO INUNDATION BY THE 1% ANNUAL CHANCE FLOOD (I.E. 100-YR. EVENT) PER FEMA FIRM MAP NO. 3720052800JJ EFFECTIVE DATE 10/03/2006. 4.ALL RIGHT-OF-WAYS ARE PUBLIC, UNLESS NOTED OTHERWISE. 5.UTILITY LINES AND SERVICES SHOWN HEREON ARE APPROXIMATE PER SURVEY AS REFERENCED, LOCATION OF UNDERGROUND UTILITIES ARE APPROXIMATE AND MUST BE FIELD VERIFIED. CALL NC ONE CALL CENTER BEFORE DIGGING AT 811. 6.COPIES OF ALL PERMITS AND APPROVED PLANS MUST BE KEPT ON-SITE IN A PERMIT BOX THAT IS CONSPICUOUSLY LOCATED AND EASILY ACCESSIBLE DURING CONSTRUCTION. 7.A SEDIMENTATION & EROSION CONTROL PERMIT WILL BE OBTAINED FROM NCDENR LAND QUALITY SECTION (SEE SHEET C4 - EROSION CONTROL PLAN). 8.A DRIVEWAY PERMIT WILL BE APPROVED BY NCDOT PRIOR TO BEGINNING CONSTRUCTION. FINAL DRIVEWAY LOCATION(S) & REQUIREMENTS ARE SUBJECT TO PERMIT REVIEW AND APPROVAL (SEE SHEET C6 - DRIVEWAY ACCESS). 9.ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE AND NORTH CAROLINA BUILDING CODE AND BE INSPECTED BY THE HARNETT COUNTY. 10.FOR ALL ADDITIONAL SITE SPECIFIC CONSTRUCTION NOTES, SEE SHEET C2 - DESIGN NOTES. 11.FOR ALL EROSION CONTROL MEASURES, SEE SHEET C4 - EROSION CONTROL PLAN. 12.FOR ALL LANDSCAPE INFORMATION SEE SHEET C5 - LANDSCAPE PLAN. 13.FOR SPECIFIC DRIVEWAY CONSTRUCTION DETAILS AND NOTATION, SE SHEET C6 - DRIVEWAY ACCESS. 14.FOR ALL SITE SPECIFIC DETAILS SEE SHEET D1 - DETAILS. 15.ALL SITE SIGNAGE TO ADHERE TO REGULATIONS SET FORTH IN ARTICLE IX, SIGN REQUIREMENTS, OF THE ZONING ORDINANCE OF HARNETT COUNTY, NORTH CAROLINA. PIN #OWNER DB/PG SITE ADDRESS ZONING CURRENT LAND USE ACRES PROPOSED USELEASE AREA DISTURBED AREA SOLAR AREA SOLAR ENERGY SYSTEM *PRELIMINARY ARE SUBJECT TO CHANGE PARCEL LINE SETBACKS REQUIRED MIN. FRONT YARD MIN. SIDE YARD MIN. REAR YARD SITE DATA 0538-58-4951 940/811 HWY 27 W RA-30 AGRICULTURE AND 16.32 AC PRELIMINARY PRELIMINARY PRELIMINARY ± 15.91 AC 0.11 AC TBD 35 FT 25 FT 25 FT PARCEL ACREAGE 16.32 AC PUCHASED AREA TBD NEW LOT TBD PER CUP SITE PLAN SUBMITTED 11/3/14 30' TYPE "B" BUFFER (SEE SHEET C5) N/F LACY B. CHAMPION ET. UX. BOOK 885, PAGE 913 PIN: 0538-59-6443.000 POINT OF INTERCONNECTION 20' (MIN.) 20' (MIN.) 20' (MIN.) PROPOSED 30' UTILITY EASEMENT PROPOSED 20' UTILITY ACCESS EASEMENT (GRAVEL ACCESS TO POINT OF INTERCONNECTION) 20' (MIN.) SCALE: 1" = 30' POINT OF INTERCONNECTION PROPOSED TREE LINE (TYP.) 25' (MIN.) ACCESS (TYP.) PROPOSED 96'Ø TURN AROUND GENERAL SITE REFERENCES LILLINGTON NC 27 W (60' P U B L I C R / W ) P E A C H F A R M R D . ( S R 1 2 5 1 ) H O L D E R R D . ( S R 1 2 5 3 ) A U T R Y R D . ( S R 1 1 3 1 ) NC LAND HOLDINGS II, LLC RURAL RESIDENTIAL NOTE: THIS DEVELOPMENT IS WITHIN ONE MILE OF A VOLUNTARY AGRICULTURAL DISTRICT. OWNER STATEMENT: AS THE OWNER OF RECORD, I HEREBY FORMALLY CONSENT TO THE PROPOSED DEVELOPMENT SHOWN ON THIS SITE PLAN AND ALL REGULATIONS AND REQUIREMENTS OF THE HARNETT COUNTY ORDINANCES. DATE OWNER / AGENT SIGNATURE PROPOSED PARKING AREA (2 SPACES WITH STOP BLOCKS) 2 3/ 1 1 / 1 6 PE R H A R N E T T C O U N T Y D R A F T D R B R E V I E W C O M M E N T S - D A T E D 2 / 2 4 / 1 6 1 1/ 6 / 1 6 PE R D E Q , L A N D Q U A L I T Y S E & S C P L A N R E V I E W C O M M E N T S HA R N E T T C O U N T Y , N O R T H C A R O L I N A C3 SITE PLAN KPB WRB 12/01/15 UP P E R L I T T L E R I V E R T O W N S H I P NC H W Y 2 7 W PE A C H S O L A R , L L C APPROXIMATE LOCATION OF EXISTING 8" AND 20" WATER MAINS (EXACT LOCATION TO BE FIELD VERIFIED) CONTACT HARNETT COUNTY PUBLIC UTILITIES: SHANE CUMMINGS SCUMMINGS@HARNETT.ORG (910) 893-7575 LANDSCAPE BUFFER SIGNAGE SCHEDULE DESCRIPTION MANUFACTURER PART NO.LOCATION WARNING / HIGH VOLTAGE SAFETY SIGN E34737 AT SITE GATE AND EVERY 300 FT ALONG PERIMETER FENCE NOTICE / NO TRESPASSING SAFETY SIGN F5949-ENG ON GATE AND EVERY 100 FT ALONG PERIMETER OF PROPERTY MAIN OWNER GATE SIGN N/A N/A AT SITE ENTRANCE GATE 1.ALL EXISTING SITE TOPOGRAPHY WITHIN THE LIMIT OF THE PROPERTY BOUND AS SHOWN HEREIN, WAS OBTAINED FROM A TOPOGRAPHICAL SURVEY, FILE NO. W-3000, PREPARED BY R.B. PHARR & ASSOCIATES, P.A., DATED 5/19/15. EXISTING SITE FEATURES AND BOUNDARIES SHOWN HEREIN WAS OBTAINED FROM AN ALTA/ACSM LAND TITLE PLAN OF LAND SURVEY OF PROPERTY OWNED BY J. E. WOMBLE AND SONS, NC HWY 27, UPPER LITTLE RIVER TOWNSHIP, HARNETT COUNTY, NC, CONDUCTED BY ENCOMPASS SERVICES, PLLC, ANGIER, NC. DATE OF ALTA SURVEY 4/13/15. 2.ALL TOPOGRAPHY SHOWN HEREIN OUTSIDE THE PROPERTY BOUNDARIES WAS OBTAINED FROM LIDAR DATA PROVIDED BY THE NC FLOOD MAPPING PROGRAM (WWW.FLOODMAPS.COM). LIDAR CONTOUR INFORMATION PROVIDED WAS BASED ON A VERTICAL DATUM OF NAVD88, AND GENERATED FROM THE 20-FOOT LIDAR DEM. CONTOURS SHOWN ARE AT AN INTERVAL OF 2-FOOT. 3.ZONING INFORMATION OBTAINED FROM CONDITIONAL USE SITE PLAN, DRAWING CU1, GROUND-MOUNT SOLAR ARRAY INSTALLATION, PEACH SOLAR, LLC, PREPARED BY ALFRED BENESCH & COMPANY, DATED 11/13/14 (SEE GENERAL ZONING NOTES HEREIN). 3.JURISDICTIONAL DETERMINATION PROVIDED BY U.S. ARMY CORPS OF ENGINEERS, WILMINGTON DISTRICT, CONFIRMED THERE ARE NO WATERS OF THE U.S., TO INCLUDE WETLANDS, PRESENT ON THE DESCRIBED PROPERTY WHICH ARE SUBJECT TO THE PERMIT REQUIREMENTS OF SECTION 404 OF THE CLEAN WATER ACT (33 USC 1344). PROPERTY LOCATED WITHIN THE UPPER CAPE FEAR RIVER BASIN. CORRESPONDENCE DATED 8/5/15, EXPIRES 5/5/20. 4.PHASE 1 ENVIRONMENTAL SITE ASSESSMENT PREPARED BY TERRACON CONSULTANTS, INC., RALEIGH, NC. (ESA) WAS PERFORMED IN ACCORDANCE WITH TERRACON PROPOSAL NO. P70140363 DATED JULY 31, 2014 AND TERRACON’S SUPPLEMENT TO AGREEMENT FOR SERVICES DATED AUGUST 15, 2014, AND WAS CONDUCTED CONSISTENT WITH THE PROCEDURES INCLUDED IN ASTM E 1527-13, STANDARD PRACTICE FOR ENVIRONMENTAL SITE ASSESSMENTS: PHASE I ENVIRONMENTAL SITE ASSESSMENT PROCESS. THE ESA WAS CONDUCTED UNDER THE SUPERVISION OR RESPONSIBLE CHARGE OF LORI C. DENTON, ENVIRONMENTAL PROFESSIONAL. MR. CHARLES CARTER PERFORMED THE SITE RECONNAISSANCE ON SEPTEMBER 3, 2014. TERRACON RECOGNIZED ENVIRONMENTAL CONDITIONS WERE NOT IDENTIFIED IN CONNECTION WITH THE SITE.