Loading...
FM PLAN REVIEW APPLICATION Harnett COUNTY .-•, oM^"� vetrowNernattag Plan Review, Inspection, and Permit Fees Application Number 1750041292 $200.00 ❑ Explosive Material (90 Days) $ - $100.00 El Explosive Materials (72 Hours) $ - $100.00 ❑ Fireworks Public Display $ - $50.00 0 Final Inspection $ 50.00 $35.00 +$2.00 per device ❑ Fire Alarm Testing $ - $35.00 +$2.00 per nozzle ❑ Fixed Fire Suppression $ - $75.00 El Insecticide Fog/Fumigation $ - $100.00 ❑ Pipe Test/UST/AGST $ - $50.00 El Plans up to 5000 sq ft $ 50.00 $100.00 ❑ Plans 5001 sq ft to 10,000 sq ft $ - $150.00 ❑ Plans 10,001 sq ft to 25,000 sq ft $ - $250.00 ❑ Plans 25,001 sq ft and over $ - $35.00 +2.00 per head ❑ Sprinkler Certification Test $ - $50.00 ❑ Standpipe Testing $ - ❑ Special Assembly $50.00 (le.amusement buildings,carnivals,fairs) $ - El $75.00 Tents/Canopies/Air Supported Structure $ $100.00 Tank Installation (charge for each tank) $ $100.00 ❑ Tank Removal (charge for each tank) $ - Total Devices/Heads $ - Total Cost $ 100.00 Code Enforcement Official Rodney Daniels 5/3/2017 negroneerr ,.. :nr:..1.,. A �FM> E•-.•Kr service.n....•ran `. • ncharnwLry May 3, 2017 Robert Shuman 2553 Housley Road, Suite 103 Annapolis, MD 28326 RE: Dunkin Donuts/Baskin Robins Application Number 17-50041292 Mr. Shuman, Thank you for submitting the plans for the up fit. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 906.1 Fire Extinguishers o A portable fire extinguisher shall be provided within a 30-foot(9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. • 1006.1 Emergency Lighting o All emergency lighting,provided prior to up fit, shall be in proper operating condition at time of final inspection. o Any changes made in illumination requirements,due to equipment placement or storage arrangements shall be addressed before final inspection. o The means of egress, including the exit discharge, shall be illuminated at all time the building space is served by the means of egress is occupied. • Means of egress consist of three separate and distinct parts: the exit access,the exit and the exit discharge. o The means of egress illumination shall not be less than 1 foot-candle at the walking surface. • 506.1 Knox Box Harnett 1.or. .ht:...K1 A (FM) L•r,.ar SOMOSO G..Mwt airtharowittag o Keys for front entrance door shall be provided to be placed in the existing box installed on the premises. • 505.1 Physical Address (ie: suite Number if Applicable) o The physical address of the building shall be posted in a conspicuous place so that it can be seen on approach from the road, access road, and/or parking lot. o The numbers used to make up the physical address shall be at least 5 inches in height. o The physical address needs to be posted on the rear of the building also. • 907.4.1 Duct Smoke detectors o Smoke detectors installed in ducts shall be listed for the air velocity, temperature and humidity present in the duct. Duct smoke detectors shall be connected to the building's fire alarm control unit when a fire alarm system is required by Section 907.2. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location and shall perform the intended fire safety function in accordance with this code and the International Mechanical Code. Duct smoke detectors shall not be used as a substitute for required open area detection. Note: Please schedule all fire Inspections through the Fire Marshal's Office(910)893- 0743. Thank you again for submitting the plans for the up fit. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions,please do not hesitate to call this office Again, thank you and we look forward to working with you during the construction period! Sincerely, Rodney Daniels Chief Deputy Fire Marshal