Structural Analysis ReportTES Project Number: 32294 Page 1 March 29, 2017 Phone (972) 483-0607, Fax (972) 975-9615 8445 Freeport Parkway, Suite 375, Irving, Texas 75063 Structural Analysis Report Existing 250 ft Sabre Self Supporting Tower Customer Name: SBA Communications Corp Customer Site Number: NC01659-B Customer Site Name: Olivia Carrier Name: AT&T Carrier Site ID / Name: 368-366 / Olivia Site Location: 696 Claude-White Road/SR 1001 Lemon Springs, North Carolina Harnett County Latitude: 35.311417 Longitude: -79.153750 Analysis Result: Max Structural Usage: 100% [Pass] Max Foundation Usage: 86% [Pass] Report Prepared By : Ram Kodali TES Project Number: 32294 Page 2 March 29, 2017 Introduction The purpose of this report is to summarize the analysis results on the 250 ft Sabre Self Supporting Tower to support the proposed antennas and transmission lines in addition to those currently installed. Any modification listed under Sources of Information was assumed completed and was included in this analysis. Sources of Information Tower Drawings Sabre, Job # SA1880-S, dated 4/20/99 Foundation Drawing Arcadis Geraghty & Miller, Projecty # NCSBASPN.0017, dated 7/26/99 Geotechnical Report Arcadis Geraghty & Miller, Projecty # NCSBASPN.0017.CTOGT, dated 4/19/99 Modification Drawings FDH, Project # 12-02715E S4, dated 2/25/13 Analysis Criteria The rigorous analysis was performed in accordance with the requirements and stipulations of the ANSI/TIA/EIA 222-G. In accordance with this standard, the structure was analyzed using TESTowers, a proprietary analysis software. The program considers the structure as an elastic 3-D model with second- order effects and temperature effects incorporated in the analysis. The analysis was performed using multiple wind directions. Basic Wind Speed Used in the Analysis: 94 mph (3-Sec. Gust) Basic Wind Speed with Ice: 30 mph (3-Sec. Gust) with 3/4” radial ice concurrent Operational Wind Speed: 60 mph + 0” Radial ice Standard/Codes: ANSI/TIA/EIA 222-G / IBC 2009 / 2012 North Carolina Building Code Exposure Category: C Structure Class: II Topographic Category: 1 Crest Height: 0 ft TES Project Number: 32294 Page 3 March 29, 2017 Existing Antennas, Mounts and Transmission Lines The table below summarizes the antennas, mounts and transmission lines that were considered in the analysis as existing on the tower. Proposed Carrier’s Final Configuration of Antennas, Mounts and Transmission Lines Information pertaining to the proposed carrier’s final configuration of antennas and transmission lines was provided by SBA Communications Corp. The proposed antennas and lines are listed below. The proposed transmission lines shall be installed on the tower face with AT&T’s transmission lines to the 235 ft. currently installed. Items Elevation (ft) Qty. Antenna Descriptions Mount Type & Qty. Transmission Lines Owner 1 250.0 3 APXVSPP18-C-A20 - Panel (3) Sector Frame (3) 1.5" Sprint 2 249.0 3 800 MHz CDMA 3 9 ACU-A20-N 4 3 1900 MHz LTE 5 3 800 MHz - 235.0 3 Cellmax CMA-BDHH/6520/E0-8 - Panel (3) Sector Frame (12) 1 5/8" (1) 3/8" RET (4) 0.756" DC (1) 0.276" Fiber AT&T - 3 SBNH-1D6565C - Panel - 3 SBNHH-1D65C - Panel - 6 RFS ATM192012-0 - TMA - 3 SBNH-1D6565C - Panel - 3 Ericsson RRUS-11 - 3 Ericsson RRUS 32 - 2 Raycap DC6-48-60-0-8F 10 220.0 3 BXA-70063-8CF-2 - Panel (3) Sector Frame (12) 1 5/8" Verizon 11 3 BXA-70080-8CF-2 - Panel 12 6 LPA-185090-8CF-2 - Panel 13 219.0 6 FD9R6004 Items Elevation (ft) Qty. Antenna Descriptions Mount Type & Qty. Transmission Lines Owner 6 235.0 6 KMW EPBQ-652L8H8 - Panel (3) Sector Frame (1) 3/8" RET (4) 0.756" DC (2) 0.276" Fiber AT&T 7 6 Ericsson RRUS-11 8 3 Ericsson RRUS 32 B2 9 2 Raycap DC6-48-60-0-8F TES Project Number: 32294 Page 4 March 29, 2017 Analysis Results The results of the structural analysis, performed for the wind and ice loading and antenna equipment as defined above, are summarized as the following: Tower Component Legs Diagonals Horizontals Max. Usage: 83.0% 100.0% 86.0% Pass/Fail Pass Pass Pass Foundations Compression (Kips) Uplift (Kips) Shear (Kips) Original Design Reactions 354.3 312.5 32.4 Analysis Reactions 376.6 321.6 37.3 Factored Reactions* 478.3 421.9 43.7 % of Design Reactions 78.7% 76.2% 85.4% * Per section 15.5.1 of the TIA-222-G standard, factored reactions were obtained by multiplying a 1.35 factor to the original design reactions. The foundation has been investigated using the supplied documents and soils report and was found to be adequate. Therefore, no modification to the foundation will be required. TES Project Number: 32294 Page 5 March 29, 2017 Operational Condition (Rigidity) Operational characteristics of the tower are found to be within the limits prescribed by ANSI/TIA/EIA 222-G for the installed antennas. The maximum twist/sway at the elevation of the proposed equipment is 0.3588 degrees under the operational wind speed as specified in the Analysis Criteria. Conclusions Based on the analysis results, the existing structure and its foundation were found to be adequate to safely support the existing and proposed equipment and meet the minimum requirements per the ANSI/TIA/EIA 222-G Standard under the design basic wind speed as specified in the Analysis Criteria. Antenna Mount Note The existing mount contributed no additional stress to the tower since it was already existing. TES Project Number: 32294 Page 6 March 29, 2017 Standard Conditions 1. This analysis was performed based on the information supplied to (TES) Tower Engineering Solutions, LLC. Verification of the information provided was not included in the Scope of Work for TES. The accuracy of the analysis is dependent on the accuracy of the information provided. 2. The analysis is based on the presumption that the tower members and components along with any existing reinforcement items have been correctly and properly designed, manufactured, installed and maintained. 3. All the existing structural members were assumed to be in good condition with no physical damage or deterioration associated with corrosion. 4. An initial tension of 10% of the break strength on all the existing guy wires was assumed in all the structural analyses of guyed towers unless different values were provided by the client. TES cannot take responsibility for the deviations in the analysis results because of differences in the initial tension forces of the existing guy wires. 5. Secondary component or connection secondary components, welds and bolts are assumed to be able to carry their intended original design loads. TES cannot take responsibility for verification of the adequacy on the connections, bolts and welds present in the structure. 6. The analyses will be performed based on the codes as specified by the client or based on the best knowledge of the engineering staff of TES. In the absence of information to the contrary, all work will be performed in accordance with the latest relevant revision of ANSI/TIA-222. If wind speed or/and ice loads are different from the minimum values recommended by the EIA/TIA-222 standard or other codes, TES should be notified in writing and the applicable minimum values provided by the client. 7. The configuration of the existing mounts, antennas, coax and other appurtenances were supplied by the customer for the current structural analysis. TES has not visited the tower site to verify the adequacy of the information provided. If there is any discrepancy found in the report regarding the existing conditions, TES should be notified immediately to evaluate the effect of the discrepancy on the analysis results. 8. The client will assume responsibility for rework associated with the differences in initially provided information, including tower and foundation information, existing and/or proposed equipment and transmission lines. 9. If a feasibility analysis was performed, final acceptance of changed conditions shall be based upon a rigorous structural analysis. Type:Self Support Site Name:Olivia Height:250.00 (ft) 3/29/2017 Page: 1 Base Shape:Triangle Base Width:27.00 Base Elev:0.00 (ft) Structure: NC01659-B-SBA Top Width:5.00 Basic WS:94.00 Basic Ice WS:30.00 Operational WS:60.00 Code:EIA/TIA-222-G Section Properties Sect Leg Members Diagonal Members Horizontal Members SAE 3X3X0.25 SAU 3.5X4X0.251PST 10" DIA PIPE SAE 3X3X0.1875 SAU 3.5X3X0.252PX 8" DIA PIPE SAU 3.5X4X0.25 3 PX 8" DIA PIPE SAE 3.5X3.5X0.25 4 PST 8" DIA PIPE SAU 3.5X3X0.25 5 PST 8" DIA PIPE SAE 3X3X0.1875 6 PX 6" DIA PIPE SAE 3X3X0.1875 7 PX 5" DIA PIPE SAE 2.5X2.5X0.1875 8 PX 5" DIA PIPE SAE 2.5X2.5X0.1875 9 PSP 4.5 x 0.438 SAE 1.75X1.75X0.1875 10 PX 3-1/2" DIA PIPE SAE 1.75X1.75X0.1875 SAE 1.75X1.75X0.187511PX 3" DIA PIPE SAE 1.75X1.75X0.1875 SAE 1.75X1.75X0.187512PX 2-1/2" DIA PIPE SAE 1.75X1.75X0.1875 SAE 1.75X1.75X0.187513PST 2" DIA PIPE Discrete Appurtenances Attach Elev (ft) Force Elev (ft)Qty Description 250.00 1 Beacon250.00 249.00 3 Sector Frame249.00 249.00 3 APXVSPP18-C-A20250.00 249.00 3 800 MHz CDMA249.00 249.00 9 ACU-A20-N249.00 249.00 3 1900 MHz LTE249.00 249.00 3 800 MHz249.00 235.00 3 Sector Frame235.00 235.00 6 EPBQ-652L8H8235.00 235.00 6 RRUS-11235.00 235.00 3 RRUS 32 B2235.00 235.00 2 DC6-48-60-0-8F235.00 220.00 3 Sector Frame220.00 220.00 3 BXA-70063-8CF-2220.00 220.00 3 BXA-70080-8CF-2220.00 220.00 6 LPA-185090-8CF-2220.00 219.00 6 FD9R6004219.00 Linear Appurtenances Elev From (ft) Elev To (ft)Qty Description 0.00 250.00 1 Climbing Ladder 0.00 250.00 1 Safety Cable 0.00 250.00 1 W/G Ladder 0.00 249.00 3 1.5" 0.00 235.00 2 0.276" Fiber 0.00 235.00 4 0.756" DC 0.00 235.00 1 3/8" RET 0.00 235.00 1 W/G Ladder 0.00 220.00 12 1 5/8" Coax 0.00 220.00 1 W/G Ladder Base Reactions Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Type:Self Support Site Name:Olivia Height:250.00 (ft) 3/29/2017 Page: 2 Base Shape:Triangle Base Width:27.00 Base Elev:0.00 (ft) Structure: NC01659-B-SBA Top Width:5.00 Basic WS:94.00 Basic Ice WS:30.00 Operational WS:60.00 Code:EIA/TIA-222-G Max Uplift: Max Down: -321.60 Leg Overturning 376.60 Max Shear:37.35 Moment:8346.05 Total Down: Total Shear: 58.99 62.58 (kips )(kips )(kips ) (ft-kips) (kips) (kips) Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. 3/29/2017 Page: 3 Structure: NC01659-B-SBA Type:Self Support Site Name:Olivia Height:250.00 (ft) Base Shape:Triangle Base Width:27.00 Base Elev:0.00 (ft)Top Width:5.00 Basic WS:94.00 Basic Ice WS:30.00 Operational WS:60.00 Code:EIA/TIA-222-G Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Type:Self Support Site Name:Olivia Height:250.00 (ft) 3/29/2017 Page: 4 Structure: NC01659-B-SBA - Coax Line Placement Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Loading Summary Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017 Page: 5 Code:EIA/TIA-222-G Exposure:C Gh:0.85 Base Elev:0.000 (ft) Crest Height:0.00 Site Class: IIStruct Class: D - Stiff Soil Topography:1 Discrete Appurtenances Properties IceNo Ice Attach Elev (ft)Description Qty Weight (lb) CaAa (sf) Weight (lb) CaAa (sf) Len (in) Width (in) Vert Ecc (ft) Depth (in)Ka Orientation Factor Beacon 1 36.00 2.720 3.717175.89250.00 28.000 17.500 17.500 0.0001.00 1.00 Sector Frame 3 500.00 17.500 32.1271233.19249.00 0.000 0.000 0.000 0.0000.75 0.75 APXVSPP18-C-A20 3 57.00 8.020 9.384268.77249.00 72.000 11.800 7.000 1.0000.90 0.83 800 MHz CDMA 3 53.00 2.490 3.691130.68249.00 19.700 13.000 10.800 0.0000.80 0.67 ACU-A20-N 9 1.00 0.140 0.4525.51249.00 4.000 2.000 3.500 0.0000.80 0.67 1900 MHz LTE 3 44.00 3.800 5.260158.65249.00 23.000 13.000 17.000 0.0000.80 0.67 800 MHz 3 53.00 2.490 3.691130.68249.00 19.700 13.000 10.800 0.0000.80 0.67 Sector Frame 3 500.00 17.500 32.0351228.57235.00 0.000 0.000 0.000 0.0000.75 0.75 EPBQ-652L8H8 6 62.40 11.980 13.779338.77235.00 99.600 12.000 6.300 0.0000.80 0.81 RRUS-11 6 44.00 2.520 3.181109.08235.00 17.000 17.800 7.200 0.0000.80 0.67 RRUS 32 B2 3 60.00 2.740 3.503152.81235.00 27.200 12.100 7.000 0.0000.80 0.67 DC6-48-60-0-8F 2 32.80 0.920 2.14587.09235.00 24.000 11.000 11.000 0.0000.90 0.90 Sector Frame 3 500.00 17.500 31.9031221.97220.00 0.000 0.000 0.000 0.0000.75 0.75 BXA-70063-8CF-2 3 24.00 10.670 12.352251.75220.00 94.600 11.200 4.500 0.0000.80 0.70 BXA-70080-8CF-2 3 23.00 8.310 9.922228.63220.00 94.700 8.100 5.700 0.0000.80 0.85 LPA-185090-8CF-2 6 7.00 2.090 2.96091.05220.00 47.400 4.100 5.900 0.0000.80 1.22 FD9R6004 6 3.10 0.370 0.84111.40219.00 5.800 6.500 1.500 0.0000.80 0.67 18,718.60 17Number of Appurtenances : Totals:6,251.6066 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Loading Summary Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017 Page: 6 Code:EIA/TIA-222-G Exposure:C Gh:0.85 Base Elev:0.000 (ft) Crest Height:0.00 Site Class: IIStruct Class: D - Stiff Soil Topography:1 Linear Appurtenances Properties Weight (lb/ft) Width (in) Pct In Block Spread On Faces Bundling Arrangement Elev. From (ft)Description Elev. To (ft)Qty Cluster Dia (in) Out of Zone Spacing (in) Orientation Factor Ka Override 0.00 250.00 Climbing Ladder 2.00 100.00 3 Individual NR 1 6.90 N 1.00 1.00 0.00 250.00 Safety Cable 0.38 100.00 3 Individual NR 1 0.27 N 1.00 1.00 0.00 250.00 W/G Ladder 3.00 100.00 3 Individual NR 1 6.00 N 1.00 1.00 0.00 249.00 1.5"1.54 100.00 3 Individual IR 3 1.15 N 1.00 1.00 0.00 235.00 0.276" Fiber 0.80 100.00 1 Individual IR 2 0.06 N 1.00 1.00 0.00 235.00 0.756" DC 0.76 50.00 1 Block 4 0.40 N 1.00 1.00 0.00 235.00 3/8" RET 0.38 100.00 1 Individual NR 1 0.06 N 1.00 1.00 0.00 235.00 W/G Ladder 3.00 100.00 1 Individual NR 1 6.00 N 1.00 1.00 0.00 220.00 1 5/8" Coax 1.98 50.00 3 Block121.04 N 0.50 1.00 0.00 220.00 W/G Ladder 2.00 100.00 3 Individual NR 1 6.00 N 1.00 1.00 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017Code:EIA/TIA-222-G Exposure:C Base Elev:0.000 (ft) Section Forces Page: 7IIStruct Class:Topography:1Gh:0.85 Crest Height:0.00 Site Class:D - Stiff Soil Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:0.00 1.2D + 1.6W 94 mph Wind at Normal To Face Wind Load Factor:1.60 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:1.20 Ice Importance Factor:1.00 16.3446.550 0.00 0.15 2.76 1.00 1 10.0 1.00 0.00 61.64 57.32 0.00 7,545.1 0.0 3780.56 1155.51 4,936.0735.89 18.8938.977 0.00 0.14 2.82 1.00 2 30.0 1.00 0.00 50.85 57.32 0.00 7,122.2 0.0 3682.52 1335.30 5,017.8228.80 21.0331.063 0.00 0.13 2.84 1.00 3 50.0 1.00 0.00 42.86 57.32 0.00 6,259.9 0.0 3481.14 1486.91 4,968.0528.80 22.5725.059 0.00 0.13 2.85 1.00 4 70.0 1.00 0.00 36.83 57.32 0.00 4,896.6 0.0 3218.77 1596.06 4,814.8328.80 23.8019.696 0.00 0.13 2.85 1.00 5 90.0 1.00 0.00 31.46 57.32 0.00 4,630.1 0.0 2900.64 1682.78 4,583.4228.80 24.8318.124 0.00 0.12 2.88 1.00 6 110.0 1.00 0.00 27.64 57.32 0.00 4,041.8 0.0 2686.37 1755.39 4,441.7622.12 25.7222.409 0.00 0.14 2.80 1.00 7 130.0 1.00 0.00 31.31 57.32 0.00 3,716.6 0.0 3068.74 1818.22 4,886.9618.57 26.5016.435 0.00 0.14 2.81 1.00 8 150.0 1.00 0.00 25.26 57.32 0.00 3,384.8 0.0 2555.72 1873.84 4,429.5618.57 27.2114.389 0.00 0.14 2.80 1.00 9 170.0 1.00 0.00 22.19 57.32 0.00 3,142.1 0.0 2301.46 1923.87 4,225.3315.02 27.8510.509 0.00 0.14 2.80 1.0010190.0 1.00 0.00 17.72 57.32 0.00 2,455.4 0.0 1877.24 1969.45 3,846.6913.36 28.45 9.382 0.00 0.17 2.71 1.0011210.0 1.00 0.00 15.97 57.32 0.00 2,233.9 0.0 1673.25 2011.38 3,684.6411.69 29.00 8.580 0.00 0.17 2.69 1.0012230.0 1.00 0.00 14.05 26.68 0.00 1,510.8 0.0 1488.64 986.41 2,475.069.58 29.39 4.558 0.00 0.16 2.72 1.0013245.0 1.00 0.00 6.81 7.94 0.00 550.0 0.0 740.69 308.53 1,049.223.96 51,489.2 0.0 53,359.39 Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:0.00 1.2D + 1.6W 94 mph Wind at 60° From Face Wind Load Factor:1.60 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:1.20 Ice Importance Factor:1.00 16.3446.550 0.00 0.15 2.76 0.80 1 10.0 1.00 0.00 52.33 57.32 0.00 7,545.1 0.0 3209.53 1155.51 4,365.0535.89 18.8938.977 0.00 0.14 2.82 0.80 2 30.0 1.00 0.00 43.05 57.32 0.00 7,122.2 0.0 3117.97 1335.30 4,453.2728.80 21.0331.063 0.00 0.13 2.84 0.80 3 50.0 1.00 0.00 36.65 57.32 0.00 6,259.9 0.0 2976.54 1486.91 4,463.4528.80 22.5725.059 0.00 0.13 2.85 0.80 4 70.0 1.00 0.00 31.82 57.32 0.00 4,896.6 0.0 2780.78 1596.06 4,376.8428.80 23.8019.696 0.00 0.13 2.85 0.80 5 90.0 1.00 0.00 27.52 57.32 0.00 4,630.1 0.0 2537.47 1682.78 4,220.2528.80 24.8318.124 0.00 0.12 2.88 0.80 6 110.0 1.00 0.00 24.01 57.32 0.00 4,041.8 0.0 2334.02 1755.39 4,089.4222.12 25.7222.409 0.00 0.14 2.80 0.80 7 130.0 1.00 0.00 26.83 57.32 0.00 3,716.6 0.0 2629.47 1818.22 4,447.7018.57 26.5016.435 0.00 0.14 2.81 0.80 8 150.0 1.00 0.00 21.97 57.32 0.00 3,384.8 0.0 2223.17 1873.84 4,097.0118.57 27.2114.389 0.00 0.14 2.80 0.80 9 170.0 1.00 0.00 19.32 57.32 0.00 3,142.1 0.0 2003.04 1923.87 3,926.9115.02 27.8510.509 0.00 0.14 2.80 0.8010190.0 1.00 0.00 15.62 57.32 0.00 2,455.4 0.0 1654.56 1969.45 3,624.0013.36 28.45 9.382 0.00 0.17 2.71 0.8011210.0 1.00 0.00 14.09 57.32 0.00 2,233.9 0.0 1476.62 2011.38 3,488.0111.69 29.00 8.580 0.00 0.17 2.69 0.8012230.0 1.00 0.00 12.33 26.68 0.00 1,510.8 0.0 1306.77 986.41 2,293.189.58 29.39 4.558 0.00 0.16 2.72 0.8013245.0 1.00 0.00 5.90 7.94 0.00 550.0 0.0 641.55 308.53 950.083.96 51,489.2 0.0 48,795.15 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017Code:EIA/TIA-222-G Exposure:C Base Elev:0.000 (ft) Section Forces Page: 8IIStruct Class:Topography:1Gh:0.85 Crest Height:0.00 Site Class:D - Stiff Soil Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:0.00 1.2D + 1.6W 94 mph Wind at 90° From Face Wind Load Factor:1.60 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:1.20 Ice Importance Factor:1.00 16.3446.550 0.00 0.15 2.76 0.85 1 10.0 1.00 0.00 54.66 57.32 0.00 7,545.1 0.0 3352.29 1155.51 4,507.8035.89 18.8938.977 0.00 0.14 2.82 0.85 2 30.0 1.00 0.00 45.00 57.32 0.00 7,122.2 0.0 3259.10 1335.30 4,594.4128.80 21.0331.063 0.00 0.13 2.84 0.85 3 50.0 1.00 0.00 38.20 57.32 0.00 6,259.9 0.0 3102.69 1486.91 4,589.6028.80 22.5725.059 0.00 0.13 2.85 0.85 4 70.0 1.00 0.00 33.07 57.32 0.00 4,896.6 0.0 2890.28 1596.06 4,486.3328.80 23.8019.696 0.00 0.13 2.85 0.85 5 90.0 1.00 0.00 28.51 57.32 0.00 4,630.1 0.0 2628.26 1682.78 4,311.0428.80 24.8318.124 0.00 0.12 2.88 0.85 6 110.0 1.00 0.00 24.92 57.32 0.00 4,041.8 0.0 2422.11 1755.39 4,177.5022.12 25.7222.409 0.00 0.14 2.80 0.85 7 130.0 1.00 0.00 27.95 57.32 0.00 3,716.6 0.0 2739.29 1818.22 4,557.5118.57 26.5016.435 0.00 0.14 2.81 0.85 8 150.0 1.00 0.00 22.80 57.32 0.00 3,384.8 0.0 2306.31 1873.84 4,180.1518.57 27.2114.389 0.00 0.14 2.80 0.85 9 170.0 1.00 0.00 20.04 57.32 0.00 3,142.1 0.0 2077.65 1923.87 4,001.5115.02 27.8510.509 0.00 0.14 2.80 0.8510190.0 1.00 0.00 16.14 57.32 0.00 2,455.4 0.0 1710.23 1969.45 3,679.6713.36 28.45 9.382 0.00 0.17 2.71 0.8511210.0 1.00 0.00 14.56 57.32 0.00 2,233.9 0.0 1525.78 2011.38 3,537.1611.69 29.00 8.580 0.00 0.17 2.69 0.8512230.0 1.00 0.00 12.76 26.68 0.00 1,510.8 0.0 1352.24 986.41 2,338.659.58 29.39 4.558 0.00 0.16 2.72 0.8513245.0 1.00 0.00 6.13 7.94 0.00 550.0 0.0 666.34 308.53 974.863.96 51,489.2 0.0 49,936.21 Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:0.00 0.9D + 1.6W 94 mph Wind at Normal To Face Wind Load Factor:1.60 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:0.90 Ice Importance Factor:1.00 16.3446.550 0.00 0.15 2.76 1.00 1 10.0 1.00 0.00 61.64 57.32 0.00 5,658.8 0.0 3780.56 1155.51 4,936.0735.89 18.8938.977 0.00 0.14 2.82 1.00 2 30.0 1.00 0.00 50.85 57.32 0.00 5,341.6 0.0 3682.52 1335.30 5,017.8228.80 21.0331.063 0.00 0.13 2.84 1.00 3 50.0 1.00 0.00 42.86 57.32 0.00 4,694.9 0.0 3481.14 1486.91 4,968.0528.80 22.5725.059 0.00 0.13 2.85 1.00 4 70.0 1.00 0.00 36.83 57.32 0.00 3,672.5 0.0 3218.77 1596.06 4,814.8328.80 23.8019.696 0.00 0.13 2.85 1.00 5 90.0 1.00 0.00 31.46 57.32 0.00 3,472.6 0.0 2900.64 1682.78 4,583.4228.80 24.8318.124 0.00 0.12 2.88 1.00 6 110.0 1.00 0.00 27.64 57.32 0.00 3,031.3 0.0 2686.37 1755.39 4,441.7622.12 25.7222.409 0.00 0.14 2.80 1.00 7 130.0 1.00 0.00 31.31 57.32 0.00 2,787.4 0.0 3068.74 1818.22 4,886.9618.57 26.5016.435 0.00 0.14 2.81 1.00 8 150.0 1.00 0.00 25.26 57.32 0.00 2,538.6 0.0 2555.72 1873.84 4,429.5618.57 27.2114.389 0.00 0.14 2.80 1.00 9 170.0 1.00 0.00 22.19 57.32 0.00 2,356.6 0.0 2301.46 1923.87 4,225.3315.02 27.8510.509 0.00 0.14 2.80 1.0010190.0 1.00 0.00 17.72 57.32 0.00 1,841.6 0.0 1877.24 1969.45 3,846.6913.36 28.45 9.382 0.00 0.17 2.71 1.0011210.0 1.00 0.00 15.97 57.32 0.00 1,675.4 0.0 1673.25 2011.38 3,684.6411.69 29.00 8.580 0.00 0.17 2.69 1.0012230.0 1.00 0.00 14.05 26.68 0.00 1,133.1 0.0 1488.64 986.41 2,475.069.58 29.39 4.558 0.00 0.16 2.72 1.0013245.0 1.00 0.00 6.81 7.94 0.00 412.5 0.0 740.69 308.53 1,049.223.96 38,616.9 0.0 53,359.39 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017Code:EIA/TIA-222-G Exposure:C Base Elev:0.000 (ft) Section Forces Page: 9IIStruct Class:Topography:1Gh:0.85 Crest Height:0.00 Site Class:D - Stiff Soil Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:0.00 0.9D + 1.6W 94 mph Wind at 60° From Face Wind Load Factor:1.60 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:0.90 Ice Importance Factor:1.00 16.3446.550 0.00 0.15 2.76 0.80 1 10.0 1.00 0.00 52.33 57.32 0.00 5,658.8 0.0 3209.53 1155.51 4,365.0535.89 18.8938.977 0.00 0.14 2.82 0.80 2 30.0 1.00 0.00 43.05 57.32 0.00 5,341.6 0.0 3117.97 1335.30 4,453.2728.80 21.0331.063 0.00 0.13 2.84 0.80 3 50.0 1.00 0.00 36.65 57.32 0.00 4,694.9 0.0 2976.54 1486.91 4,463.4528.80 22.5725.059 0.00 0.13 2.85 0.80 4 70.0 1.00 0.00 31.82 57.32 0.00 3,672.5 0.0 2780.78 1596.06 4,376.8428.80 23.8019.696 0.00 0.13 2.85 0.80 5 90.0 1.00 0.00 27.52 57.32 0.00 3,472.6 0.0 2537.47 1682.78 4,220.2528.80 24.8318.124 0.00 0.12 2.88 0.80 6 110.0 1.00 0.00 24.01 57.32 0.00 3,031.3 0.0 2334.02 1755.39 4,089.4222.12 25.7222.409 0.00 0.14 2.80 0.80 7 130.0 1.00 0.00 26.83 57.32 0.00 2,787.4 0.0 2629.47 1818.22 4,447.7018.57 26.5016.435 0.00 0.14 2.81 0.80 8 150.0 1.00 0.00 21.97 57.32 0.00 2,538.6 0.0 2223.17 1873.84 4,097.0118.57 27.2114.389 0.00 0.14 2.80 0.80 9 170.0 1.00 0.00 19.32 57.32 0.00 2,356.6 0.0 2003.04 1923.87 3,926.9115.02 27.8510.509 0.00 0.14 2.80 0.8010190.0 1.00 0.00 15.62 57.32 0.00 1,841.6 0.0 1654.56 1969.45 3,624.0013.36 28.45 9.382 0.00 0.17 2.71 0.8011210.0 1.00 0.00 14.09 57.32 0.00 1,675.4 0.0 1476.62 2011.38 3,488.0111.69 29.00 8.580 0.00 0.17 2.69 0.8012230.0 1.00 0.00 12.33 26.68 0.00 1,133.1 0.0 1306.77 986.41 2,293.189.58 29.39 4.558 0.00 0.16 2.72 0.8013245.0 1.00 0.00 5.90 7.94 0.00 412.5 0.0 641.55 308.53 950.083.96 38,616.9 0.0 48,795.15 Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:0.00 0.9D + 1.6W 94 mph Wind at 90° From Face Wind Load Factor:1.60 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:0.90 Ice Importance Factor:1.00 16.3446.550 0.00 0.15 2.76 0.85 1 10.0 1.00 0.00 54.66 57.32 0.00 5,658.8 0.0 3352.29 1155.51 4,507.8035.89 18.8938.977 0.00 0.14 2.82 0.85 2 30.0 1.00 0.00 45.00 57.32 0.00 5,341.6 0.0 3259.10 1335.30 4,594.4128.80 21.0331.063 0.00 0.13 2.84 0.85 3 50.0 1.00 0.00 38.20 57.32 0.00 4,694.9 0.0 3102.69 1486.91 4,589.6028.80 22.5725.059 0.00 0.13 2.85 0.85 4 70.0 1.00 0.00 33.07 57.32 0.00 3,672.5 0.0 2890.28 1596.06 4,486.3328.80 23.8019.696 0.00 0.13 2.85 0.85 5 90.0 1.00 0.00 28.51 57.32 0.00 3,472.6 0.0 2628.26 1682.78 4,311.0428.80 24.8318.124 0.00 0.12 2.88 0.85 6 110.0 1.00 0.00 24.92 57.32 0.00 3,031.3 0.0 2422.11 1755.39 4,177.5022.12 25.7222.409 0.00 0.14 2.80 0.85 7 130.0 1.00 0.00 27.95 57.32 0.00 2,787.4 0.0 2739.29 1818.22 4,557.5118.57 26.5016.435 0.00 0.14 2.81 0.85 8 150.0 1.00 0.00 22.80 57.32 0.00 2,538.6 0.0 2306.31 1873.84 4,180.1518.57 27.2114.389 0.00 0.14 2.80 0.85 9 170.0 1.00 0.00 20.04 57.32 0.00 2,356.6 0.0 2077.65 1923.87 4,001.5115.02 27.8510.509 0.00 0.14 2.80 0.8510190.0 1.00 0.00 16.14 57.32 0.00 1,841.6 0.0 1710.23 1969.45 3,679.6713.36 28.45 9.382 0.00 0.17 2.71 0.8511210.0 1.00 0.00 14.56 57.32 0.00 1,675.4 0.0 1525.78 2011.38 3,537.1611.69 29.00 8.580 0.00 0.17 2.69 0.8512230.0 1.00 0.00 12.76 26.68 0.00 1,133.1 0.0 1352.24 986.41 2,338.659.58 29.39 4.558 0.00 0.16 2.72 0.8513245.0 1.00 0.00 6.13 7.94 0.00 412.5 0.0 666.34 308.53 974.863.96 38,616.9 0.0 49,936.21 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017Code:EIA/TIA-222-G Exposure:C Base Elev:0.000 (ft) Section Forces Page: 10IIStruct Class:Topography:1Gh:0.85 Crest Height:0.00 Site Class:D - Stiff Soil Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:1.00 1.2D + 1.0Di + 1.0Wi 30 mph Wind at Normal From Face Wind Load Factor:1.00 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:1.20 Ice Importance Factor:1.00 1.6646.550 34.94 0.22 2.54 1.00 1 10.0 1.00 1.33 87.46 92.52 13.31 15,386. 1 7841.0 314.58 147.10 461.6870.83 1.9238.977 37.23 0.21 2.56 1.00 2 30.0 1.00 1.49 77.03 96.13 14.86 15,117. 3 7995.2 322.69 178.67 501.3666.02 2.1431.063 35.48 0.21 2.57 1.00 3 50.0 1.00 1.56 68.07 97.94 15.64 12,720. 9 6461.0 318.70 203.82 522.5364.27 2.3025.059 34.73 0.21 2.56 1.00 4 70.0 1.00 1.62 61.68 99.19 16.17 11,202. 9 6306.3 308.56 222.12 530.6863.53 2.4219.696 33.64 0.22 2.54 1.00 5 90.0 1.00 1.66 55.76 100.15 16.58 10,732. 1 6102.0 292.14 236.75 528.8962.44 2.5318.124 32.36 0.22 2.54 1.00 6 110.0 1.00 1.69 49.58 100.94 16.92 9,672.6 5630.8 271.19 249.41 520.6054.48 2.6222.409 37.99 0.27 2.39 1.00 7 130.0 1.00 1.72 55.76 101.60 17.20 9,879.0 6162.4 296.12 257.43 553.5556.56 2.7016.435 35.41 0.28 2.36 1.00 8 150.0 1.00 1.75 48.38 102.18 17.45 8,985.6 5600.7 262.19 266.66 528.8553.98 2.7714.389 32.81 0.29 2.32 1.00 9 170.0 1.00 1.77 42.91 102.69 17.67 8,404.7 5262.6 234.40 274.50 508.9047.83 2.8410.509 34.19 0.34 2.20 1.0010190.0 1.00 1.79 39.56 103.15 17.87 7,356.0 4900.6 210.27 279.64 489.9147.54 2.90 9.382 32.20 0.40 2.06 1.0011210.0 1.00 1.80 37.38 103.57 18.05 6,958.7 4724.8 189.29 280.87 470.1743.88 2.95 8.580 30.67 0.44 1.99 1.0012230.0 1.00 1.82 34.94 62.49 10.63 4,936.4 3425.6 174.49 169.33 343.8140.26 2.99 4.558 15.96 0.44 1.98 1.0013245.0 1.00 1.83 17.64 18.30 3.05 1,979.5 1429.5 88.96 51.09 140.0519.92 123,331.8 71842.5 6,100.97 Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:1.00 1.2D + 1.0Di + 1.0Wi 30 mph Wind at 60° From Face Wind Load Factor:1.00 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:1.20 Ice Importance Factor:1.00 1.6646.550 34.94 0.22 2.54 0.80 1 10.0 1.00 1.33 78.15 92.52 13.31 15,386. 1 7841.0 281.09 147.10 428.1970.83 1.9238.977 37.23 0.21 2.56 0.80 2 30.0 1.00 1.49 69.24 96.13 14.86 15,117. 3 7995.2 290.04 178.67 468.7066.02 2.1431.063 35.48 0.21 2.57 0.80 3 50.0 1.00 1.56 61.86 97.94 15.64 12,720. 9 6461.0 289.62 203.82 493.4464.27 2.3025.059 34.73 0.21 2.56 0.80 4 70.0 1.00 1.62 56.67 99.19 16.17 11,202. 9 6306.3 283.49 222.12 505.6163.53 2.4219.696 33.64 0.22 2.54 0.80 5 90.0 1.00 1.66 51.82 100.15 16.58 10,732. 1 6102.0 271.50 236.75 508.2562.44 2.5318.124 32.36 0.22 2.54 0.80 6 110.0 1.00 1.69 45.96 100.94 16.92 9,672.6 5630.8 251.36 249.41 500.7854.48 2.6222.409 37.99 0.27 2.39 0.80 7 130.0 1.00 1.72 51.27 101.60 17.20 9,879.0 6162.4 272.32 257.43 529.7556.56 2.7016.435 35.41 0.28 2.36 0.80 8 150.0 1.00 1.75 45.10 102.18 17.45 8,985.6 5600.7 244.38 266.66 511.0453.98 2.7714.389 32.81 0.29 2.32 0.80 9 170.0 1.00 1.77 40.04 102.69 17.67 8,404.7 5262.6 218.68 274.50 493.1847.83 2.8410.509 34.19 0.34 2.20 0.8010190.0 1.00 1.79 37.46 103.15 17.87 7,356.0 4900.6 199.10 279.64 478.7447.54 2.90 9.382 32.20 0.40 2.06 0.8011210.0 1.00 1.80 35.50 103.57 18.05 6,958.7 4724.8 179.79 280.87 460.6643.88 2.95 8.580 30.67 0.44 1.99 0.8012230.0 1.00 1.82 33.22 62.49 10.63 4,936.4 3425.6 165.91 169.33 335.2440.26 2.99 4.558 15.96 0.44 1.98 0.8013245.0 1.00 1.83 16.73 18.30 3.05 1,979.5 1429.5 84.36 51.09 135.4519.92 123,331.8 71842.5 5,849.03 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017Code:EIA/TIA-222-G Exposure:C Base Elev:0.000 (ft) Section Forces Page: 11IIStruct Class:Topography:1Gh:0.85 Crest Height:0.00 Site Class:D - Stiff Soil Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:1.00 1.2D + 1.0Di + 1.0Wi 30 mph Wind at 90° From Face Wind Load Factor:1.00 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:1.20 Ice Importance Factor:1.00 1.6646.550 34.94 0.22 2.54 0.85 1 10.0 1.00 1.33 80.48 92.52 13.31 15,386. 1 7841.0 289.46 147.10 436.5670.83 1.9238.977 37.23 0.21 2.56 0.85 2 30.0 1.00 1.49 71.18 96.13 14.86 15,117. 3 7995.2 298.20 178.67 476.8766.02 2.1431.063 35.48 0.21 2.57 0.85 3 50.0 1.00 1.56 63.41 97.94 15.64 12,720. 9 6461.0 296.89 203.82 500.7164.27 2.3025.059 34.73 0.21 2.56 0.85 4 70.0 1.00 1.62 57.92 99.19 16.17 11,202. 9 6306.3 289.76 222.12 511.8763.53 2.4219.696 33.64 0.22 2.54 0.85 5 90.0 1.00 1.66 52.80 100.15 16.58 10,732. 1 6102.0 276.66 236.75 513.4162.44 2.5318.124 32.36 0.22 2.54 0.85 6 110.0 1.00 1.69 46.86 100.94 16.92 9,672.6 5630.8 256.32 249.41 505.7354.48 2.6222.409 37.99 0.27 2.39 0.85 7 130.0 1.00 1.72 52.39 101.60 17.20 9,879.0 6162.4 278.27 257.43 535.7056.56 2.7016.435 35.41 0.28 2.36 0.85 8 150.0 1.00 1.75 45.92 102.18 17.45 8,985.6 5600.7 248.83 266.66 515.4953.98 2.7714.389 32.81 0.29 2.32 0.85 9 170.0 1.00 1.77 40.76 102.69 17.67 8,404.7 5262.6 222.61 274.50 497.1147.83 2.8410.509 34.19 0.34 2.20 0.8510190.0 1.00 1.79 37.99 103.15 17.87 7,356.0 4900.6 201.89 279.64 481.5347.54 2.90 9.382 32.20 0.40 2.06 0.8511210.0 1.00 1.80 35.97 103.57 18.05 6,958.7 4724.8 182.17 280.87 463.0443.88 2.95 8.580 30.67 0.44 1.99 0.8512230.0 1.00 1.82 33.65 62.49 10.63 4,936.4 3425.6 168.06 169.33 337.3840.26 2.99 4.558 15.96 0.44 1.98 0.8513245.0 1.00 1.83 16.96 18.30 3.05 1,979.5 1429.5 85.51 51.09 136.6019.92 123,331.8 71842.5 5,912.02 Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:0.00 1.0D + 1.0W 60 mph Wind at Normal To Face Wind Load Factor:1.00 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:1.00 Ice Importance Factor:1.00 6.6646.550 0.00 0.15 2.76 1.00 1 10.0 1.00 0.00 64.03 57.32 0.00 6,287.6 0.0 1000.01 294.24 1,294.2535.89 7.6938.977 0.00 0.14 2.82 1.00 2 30.0 1.00 0.00 53.80 57.32 0.00 5,935.1 0.0 992.09 340.02 1,332.1128.80 8.5731.063 0.00 0.13 2.84 1.00 3 50.0 1.00 0.00 45.52 57.32 0.00 5,216.6 0.0 941.41 378.63 1,320.0428.80 9.2025.059 0.00 0.13 2.85 1.00 4 70.0 1.00 0.00 39.27 57.32 0.00 4,080.5 0.0 873.94 406.42 1,280.3628.80 9.7019.696 0.00 0.13 2.85 1.00 5 90.0 1.00 0.00 33.73 57.32 0.00 3,858.4 0.0 791.82 428.50 1,220.3228.80 10.1218.124 0.00 0.12 2.88 1.00 6 110.0 1.00 0.00 30.00 57.32 0.00 3,368.2 0.0 742.62 446.99 1,189.6122.12 10.4822.409 0.00 0.14 2.80 1.00 7 130.0 1.00 0.00 32.92 57.32 0.00 3,097.2 0.0 821.62 462.99 1,284.6118.57 10.8016.435 0.00 0.14 2.81 1.00 8 150.0 1.00 0.00 26.90 57.32 0.00 2,820.7 0.0 693.05 477.15 1,170.2118.57 11.0914.389 0.00 0.14 2.80 1.00 9 170.0 1.00 0.00 22.90 57.32 0.00 2,618.4 0.0 604.79 489.89 1,094.6815.02 11.3510.509 0.00 0.14 2.80 1.0010190.0 1.00 0.00 18.08 57.32 0.00 2,046.2 0.0 487.77 501.50 989.2713.36 11.59 9.382 0.00 0.17 2.71 1.0011210.0 1.00 0.00 16.04 57.32 0.00 1,861.6 0.0 427.94 512.18 940.1211.69 11.81 8.580 0.00 0.17 2.69 1.0012230.0 1.00 0.00 14.05 26.68 0.00 1,259.0 0.0 379.07 251.18 630.259.58 11.97 4.558 0.00 0.16 2.72 1.0013245.0 1.00 0.00 6.81 7.94 0.00 458.4 0.0 188.61 78.56 267.173.96 42,907.7 0.0 14,013.00 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017Code:EIA/TIA-222-G Exposure:C Base Elev:0.000 (ft) Section Forces Page: 12IIStruct Class:Topography:1Gh:0.85 Crest Height:0.00 Site Class:D - Stiff Soil Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:0.00 1.0D + 1.0W 60 mph Wind at 60° From Face Wind Load Factor:1.00 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:1.00 Ice Importance Factor:1.00 6.6646.550 0.00 0.15 2.76 0.80 1 10.0 1.00 0.00 54.72 57.32 0.00 6,287.6 0.0 854.60 294.24 1,148.8535.89 7.6938.977 0.00 0.14 2.82 0.80 2 30.0 1.00 0.00 46.00 57.32 0.00 5,935.1 0.0 848.33 340.02 1,188.3528.80 8.5731.063 0.00 0.13 2.84 0.80 3 50.0 1.00 0.00 39.31 57.32 0.00 5,216.6 0.0 812.92 378.63 1,191.5528.80 9.2025.059 0.00 0.13 2.85 0.80 4 70.0 1.00 0.00 34.26 57.32 0.00 4,080.5 0.0 762.41 406.42 1,168.8328.80 9.7019.696 0.00 0.13 2.85 0.80 5 90.0 1.00 0.00 29.79 57.32 0.00 3,858.4 0.0 699.34 428.50 1,127.8428.80 10.1218.124 0.00 0.12 2.88 0.80 6 110.0 1.00 0.00 26.38 57.32 0.00 3,368.2 0.0 652.89 446.99 1,099.8922.12 10.4822.409 0.00 0.14 2.80 0.80 7 130.0 1.00 0.00 28.44 57.32 0.00 3,097.2 0.0 709.77 462.99 1,172.7618.57 10.8016.435 0.00 0.14 2.81 0.80 8 150.0 1.00 0.00 23.61 57.32 0.00 2,820.7 0.0 608.37 477.15 1,085.5318.57 11.0914.389 0.00 0.14 2.80 0.80 9 170.0 1.00 0.00 20.03 57.32 0.00 2,618.4 0.0 528.80 489.89 1,018.6915.02 11.3510.509 0.00 0.14 2.80 0.8010190.0 1.00 0.00 15.98 57.32 0.00 2,046.2 0.0 431.07 501.50 932.5713.36 11.59 9.382 0.00 0.17 2.71 0.8011210.0 1.00 0.00 14.16 57.32 0.00 1,861.6 0.0 377.87 512.18 890.0511.69 11.81 8.580 0.00 0.17 2.69 0.8012230.0 1.00 0.00 12.33 26.68 0.00 1,259.0 0.0 332.76 251.18 583.949.58 11.97 4.558 0.00 0.16 2.72 0.8013245.0 1.00 0.00 5.90 7.94 0.00 458.4 0.0 163.36 78.56 241.933.96 42,907.7 0.0 12,850.77 Sect Seq qz (psf) Total Flat Area (sqft) Ice Round Area (sqft) Sol Ratio Cf Df Wind Height (ft)Dr Ice Thick (in) Eff Area (sqft) Linear Area (sqft) Ice Linear Area (sqft) Total Weight (lb) Weight Ice (lb) Struct Force (lb) Linear Force (lb) Total Force (lb) Ice Dead Load Factor:0.00 1.0D + 1.0W 60 mph Wind at 90° From Face Wind Load Factor:1.00 Total Round Area (sqft) Wind Importance Factor:1.00Dead Load Factor:1.00 Ice Importance Factor:1.00 6.6646.550 0.00 0.15 2.76 0.85 1 10.0 1.00 0.00 57.05 57.32 0.00 6,287.6 0.0 890.96 294.24 1,185.2035.89 7.6938.977 0.00 0.14 2.82 0.85 2 30.0 1.00 0.00 47.95 57.32 0.00 5,935.1 0.0 884.27 340.02 1,224.2928.80 8.5731.063 0.00 0.13 2.84 0.85 3 50.0 1.00 0.00 40.86 57.32 0.00 5,216.6 0.0 845.04 378.63 1,223.6728.80 9.2025.059 0.00 0.13 2.85 0.85 4 70.0 1.00 0.00 35.51 57.32 0.00 4,080.5 0.0 790.29 406.42 1,196.7128.80 9.7019.696 0.00 0.13 2.85 0.85 5 90.0 1.00 0.00 30.77 57.32 0.00 3,858.4 0.0 722.46 428.50 1,150.9628.80 10.1218.124 0.00 0.12 2.88 0.85 6 110.0 1.00 0.00 27.28 57.32 0.00 3,368.2 0.0 675.32 446.99 1,122.3222.12 10.4822.409 0.00 0.14 2.80 0.85 7 130.0 1.00 0.00 29.56 57.32 0.00 3,097.2 0.0 737.73 462.99 1,200.7218.57 10.8016.435 0.00 0.14 2.81 0.85 8 150.0 1.00 0.00 24.44 57.32 0.00 2,820.7 0.0 629.54 477.15 1,106.7018.57 11.0914.389 0.00 0.14 2.80 0.85 9 170.0 1.00 0.00 20.75 57.32 0.00 2,618.4 0.0 547.80 489.89 1,037.6915.02 11.3510.509 0.00 0.14 2.80 0.8510190.0 1.00 0.00 16.50 57.32 0.00 2,046.2 0.0 445.25 501.50 946.7513.36 11.59 9.382 0.00 0.17 2.71 0.8511210.0 1.00 0.00 14.63 57.32 0.00 1,861.6 0.0 390.39 512.18 902.5711.69 11.81 8.580 0.00 0.17 2.69 0.8512230.0 1.00 0.00 12.76 26.68 0.00 1,259.0 0.0 344.33 251.18 595.519.58 11.97 4.558 0.00 0.16 2.72 0.8513245.0 1.00 0.00 6.13 7.94 0.00 458.4 0.0 169.68 78.56 248.243.96 42,907.7 0.0 13,141.33 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017Code:EIA/TIA-222-G Exposure:C Base Elev:0.000 (ft) Force/Stress Compression Summary Page: 13IIStruct Class:Topography:1Gh:0.85 Crest Height:0.00 Site Class:D - Stiff Soil Member Force (kips)Load Case Len (ft) Bracing % KL/R Fy (ksi) Mem Cap (kips) Leg Use %ControlsX Y ZSect Top Elev LEG MEMBERS PST - 10" DIA PIPE -363.46 1.2D + 1.6W Normal Wind 10.02 50 50 50 16.38 525.10 69.0 Member X50.00120 PX - 8" DIA PIPE -333.47 1.2D + 1.6W Normal Wind 10.02 50 50 50 20.88 556.18 59.0 Member X50.00240 PX - 8" DIA PIPE -309.90 1.2D + 1.6W Normal Wind 9.64 100 100 100 40.20 510.21 60.0 Member X50.00360 PST - 8" DIA PIPE -280.89 1.2D + 1.6W Normal Wind 9.64 100 100 100 39.35 337.54 83.0 Member X50.00480 PST - 8" DIA PIPE -252.43 1.2D + 1.6W Normal Wind 9.64 100 100 100 39.35 337.54 74.0 Member X50.005100 PX - 6" DIA PIPE -223.98 1.2D + 1.6W Normal Wind 9.64 100 100 100 52.83 308.23 72.0 Member X50.006120 PX - 5" DIA PIPE -197.57 1.2D + 1.6W Normal Wind 6.43 100 100 100 41.92 241.80 81.0 Member X50.007140 PX - 5" DIA PIPE -169.18 1.2D + 1.6W Normal Wind 6.43 100 100 100 41.92 241.80 69.0 Member X50.008160 PSP - 4.5 x 0.438 -140.71 1.2D + 1.6W Normal Wind 6.43 100 100 100 53.69 203.71 69.0 Member X50.009180 PX - 3-1/2" DIA PIPE -112.67 1.2D + 1.6W Normal Wind 4.82 100 100 100 44.16 143.60 78.0 Member X50.0010200 PX - 3" DIA PIPE -80.76 1.2D + 1.6W Normal Wind 4.91 100 100 100 51.73 111.75 72.0 Member X50.0011220 PX - 2-1/2" DIA PIPE -41.54 1.2D + 1.6W Normal Wind 4.91 100 100 100 63.72 75.24 55.0 Member X50.0012240 PST - 2" DIA PIPE -6.76 1.2D + 1.6W Normal Wind 4.63 100 100 100 70.52 33.47 20.0 Member X50.0013250 Force (kips)Load Case Len (ft) Bracing % KL/R Fy (ksi) Mem Cap (kips) Num Bolts Num Holes Shear Cap (kips) Bear Cap (kips) Use %ControlsX Y Z HORIZONTAL MEMBERS MemberSect Top Elev 1 20 SAU - 3.5X4X0.25 1.2D + 1.6W 90° Wind 12.50 100 100 100 171.88 13.84 2 1 24.86 34.80 68 Member Z-9.43 36.00 2 40 SAU - 3.5X3X0.25 1.2D + 1.6W 90° Wind 12.00 100 100 100 186.55 10.13 2 1 24.86 34.80 86 Member Z-8.72 36.00 3 60 0.00 0 0 4 80 0.00 0 0 5 100 0.00 0 0 6 120 0.00 0 0 7 140 0.00 0 0 8 160 0.00 0 0 9 180 0.00 0 0 10 200 0.00 0 0 11 220 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 60° Wind 5.00 100 100 100 174.93 4.58 1 1 12.43 11.09 7 Member Z-0.36 36.00 12 240 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 60° Wind 5.00 100 100 100 174.93 4.58 1 1 12.43 11.09 1 Member Z-0.07 36.00 13 250 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 60° Wind 5.00 100 100 100 174.93 4.58 1 1 12.43 11.09 5 Member Z-0.26 36.00 Force (kips)Load Case Len (ft) Bracing % KL/R Fy (ksi) Mem Cap (kips) Num Bolts Num Holes Shear Cap (kips) Bear Cap (kips) Use %ControlsX Y Z DIAGONAL MEMBERS MemberSect Top Elev 1 20 SAE - 3X3X0.25 1.2D + 1.6W 90° Wind 16.40 48 48 48 144.36 15.61 2 1 24.86 34.8 0 82 Member Z-12.8 7 36.00 2 40 SAE - 3X3X0.1875 1.2D + 1.6W 90° Wind 16.01 48 48 48 141.36 12.32 2 1 24.86 25.1 2 100 Member Z-12.3 6 36.00 3 60 SAU - 3.5X4X0.25 1.2D + 1.6W 90° Wind 24.46 48 48 48 191.92 11.10 1 1 17.89 14.3 6 83 Member Z-9.23 36.00 4 80 SAE - 3.5X3.5X0.25 1.2D + 1.6W 90° Wind 22.63 48 48 48 187.84 10.82 1 1 17.89 14.3 6 79 Member Z-8.59 36.00 5 100 SAU - 3.5X3X0.25 1.2D + 1.6W 90° Wind 20.84 48 48 48 190.23 9.74 1 1 17.89 14.3 6 81 Member Z-7.92 36.00 6 120 SAE - 3X3X0.1875 1.2D + 1.6W 90° Wind 19.09 48 48 48 184.47 7.24 1 1 17.89 10.7 7 98 Member Z-7.15 36.00 7 140 SAE - 3X3X0.1875 1.2D + 1.6W 90° Wind 15.99 49 49 49 157.72 9.90 1 1 17.89 10.7 7 63 Member Z-6.24 36.00 8 160 SAE - 2.5X2.5X0.1875 1.2D + 1.6W 90° Wind 14.18 49 49 49 168.42 7.18 1 1 12.43 11.0 9 77 Member Z-5.56 36.00 9 180 SAE - 2.5X2.5X0.1875 1.2D + 1.6W 90° Wind 12.43 49 49 49 147.63 9.35 1 1 12.43 11.0 9 52 Member Z-4.91 36.00 10 200 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 90° Wind 9.96 49 49 49 170.78 4.80 1 1 12.43 11.0 9 88 Member Z-4.24 36.00 11 220 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 90° Wind 8.32 49 49 49 142.62 6.89 1 1 12.43 11.0 9 59 Member Z-4.07 36.00 12 240 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 90° Wind 7.01 49 49 49 120.09 9.40 1 1 12.43 11.0 9 48 Member Z-4.59 36.00 13 250 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 90° Wind 6.81 49 49 49 117.57 9.70 1 1 12.43 11.0 9 17 Member Z-1.68 36.00 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017Code:EIA/TIA-222-G Exposure:C Base Elev:0.000 (ft) Force/Stress Tension Summary Page: 14IIStruct Class:Topography:1Gh:0.85 Crest Height:0.00 Site Class:D - Stiff Soil Member Force (kips)Load Case Fy (ksi) Mem Cap (kips) Leg Use %Controls Top ElevSect LEG MEMBERS 1 20 PST - 10" DIA PIPE 311.26 0.9D + 1.6W 60° Wind 50 58.00 Member535.50 2 40 PX - 8" DIA PIPE 287.36 0.9D + 1.6W 60° Wind 50 50.00 Member574.20 3 60 PX - 8" DIA PIPE 276.37 0.9D + 1.6W 60° Wind 50 48.00 Member574.20 4 80 PST - 8" DIA PIPE 250.19 1.2D + 1.6W 60° Wind 50 66.00 Member378.00 5 100 PST - 8" DIA PIPE 228.99 0.9D + 1.6W 60° Wind 50 60.00 Member378.00 6 120 PX - 6" DIA PIPE 204.86 0.9D + 1.6W 60° Wind 50 54.00 Member378.00 7 140 PX - 5" DIA PIPE 179.08 1.2D + 1.6W 60° Wind 50 65.00 Member274.95 8 160 PX - 5" DIA PIPE 154.77 1.2D + 1.6W 60° Wind 50 56.00 Member274.95 9 180 PSP - 4.5 x 0.438 130.95 0.9D + 1.6W 60° Wind 50 52.00 Member251.51 10 200 PX - 3-1/2" DIA PIPE 104.89 0.9D + 1.6W 60° Wind 50 63.00 Member165.60 11 220 PX - 3" DIA PIPE 76.12 0.9D + 1.6W 60° Wind 50 56.00 Member135.90 12 240 PX - 2-1/2" DIA PIPE 35.57 1.2D + 1.6W 60° Wind 50 35.00 Member101.25 13 250 PST - 2" DIA PIPE 6.35 0.9D + 1.6W 60° Wind 50 13.00 Member48.15 Member Force (kips)Load Case Fy (ksi) Mem Cap (kips) Num Bolts Num Holes Shear Cap (kips) Bear Cap (kips) Use %Controls Top ElevSect HORIZONTAL MEMBERS B.S. Cap (kips) 1 20 SAU - 3.5X4X0.25 1.2D + 1.6W 90° Wind 36 2 1 24.86 34.80 39 Bolt Shear58.649.71 30.83 2 40 SAU - 3.5X3X0.25 1.2D + 1.6W 90° Wind 36 2 1 24.86 34.80 36 Bolt Shear50.549.07 25.40 3 60 - 36 0 00.00 4 80 - 36 0 00.00 5 100 - 36 0 00.00 6 120 - 36 0 00.00 7 140 - 36 0 00.00 8 160 - 36 0 00.00 9 180 - 36 0 00.00 10 200 - 36 0 00.00 11 220 SAE - 1.75X1.75X0.1875 1.2D + 1.6W Normal Wind 36 1 1 12.43 11.09 3 Blck Shear15.640.26 7.88 12 240 SAE - 1.75X1.75X0.1875 1.2D + 1.6W Normal Wind 36 1 1 12.43 11.09 Blck Shear15.640.01 7.88 13 250 SAE - 1.75X1.75X0.1875 1.2D + 1.6W Normal Wind 36 1 1 12.43 11.09 4 Blck Shear15.640.32 7.88 Member Force (kips)Load Case Fy (ksi) Mem Cap (kips) Num Bolts Num Holes Shear Cap (kips) Bear Cap (kips) Use %Controls Top ElevSect DIAGONAL MEMBERS B.S. Cap (kips) 1 20 SAE - 3X3X0.25 1.2D + 1.6W 90° Wind 36 2 1 24.86 34.80 53 Blck Shear40.8612.04 22.68 2 40 SAE - 3X3X0.1875 0.9D + 1.6W 90° Wind 36 2 1 24.86 25.12 70 Blck Shear30.9711.69 16.63 3 60 SAU - 3.5X4X0.25 1.2D + 1.6W 90° Wind 36 1 1 17.89 14.36 63 Bolt Bear51.919.18 4 80 SAE - 3.5X3.5X0.25 1.2D + 1.6W 90° Wind 36 1 1 17.89 14.36 58 Bolt Bear48.008.36 16.62 5 100 SAU - 3.5X3X0.25 1.2D + 1.6W 90° Wind 36 1 1 17.89 14.36 53 Bolt Bear43.767.74 6 120 SAE - 3X3X0.1875 1.2D + 1.6W 90° Wind 36 1 1 17.89 10.77 68 Blck Shear30.217.18 10.42 7 140 SAE - 3X3X0.1875 1.2D + 1.6W 90° Wind 36 1 1 17.89 10.77 58 Blck Shear30.216.12 10.42 8 160 SAE - 2.5X2.5X0.1875 1.2D + 1.6W 90° Wind 36 1 1 12.43 11.09 55 Blck Shear24.845.47 9.91 9 180 SAE - 2.5X2.5X0.1875 1.2D + 1.6W 90° Wind 36 1 1 12.43 11.09 50 Blck Shear24.845.01 9.91 10 200 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 90° Wind 36 1 1 12.43 11.09 56 Blck Shear15.644.45 7.88 11 220 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 90° Wind 36 1 1 12.43 11.09 51 Blck Shear15.644.05 7.88 12 240 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 90° Wind 36 1 1 12.43 11.09 56 Blck Shear15.644.46 7.88 13 250 SAE - 1.75X1.75X0.1875 1.2D + 1.6W 90° Wind 36 1 1 12.43 11.09 21 Blck Shear15.641.68 7.88 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Support Forces Summary Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017 Page: 15 Code:EIA/TIA-222-G Exposure:C Gh:0.85 Base Elev:0.000 (ft) Crest Height:0.00 Site Class: IIStruct Class: D - Stiff Soil Topography:1 Load Case FX (kips) FY (kips) FZ (kips)(-) = Uplift (+) = DownNode 1 0.00 376.601.2D + 1.6W Normal Wind -37.35 1a 11.60 -158.80 -12.62 1b -11.60 -158.80 -12.62 1 -4.43 188.111.2D + 1.6W 60° Wind -18.35 1a -18.10 188.06 5.34 1b -27.71 -317.18 -16.00 1 -5.38 19.671.2D + 1.6W 90° Wind -1.70 1a -28.12 315.70 13.27 1b -25.65 -276.37 -11.57 1 0.00 371.160.9D + 1.6W Normal Wind -36.91 1a 11.95 -163.46 -12.83 1b -11.95 -163.46 -12.83 1 -4.44 182.940.9D + 1.6W 60° Wind -17.92 1a -17.74 182.90 5.12 1b -28.07 -321.60 -16.20 1 -5.39 14.750.9D + 1.6W 90° Wind -1.28 1a -27.75 310.35 13.05 1b -26.01 -280.85 -11.77 1 0.00 83.761.2D + 1.0Di + 1.0Wi Normal Wind -6.98 1a -1.47 28.67 0.25 1b 1.47 28.67 0.25 1 -0.49 64.901.2D + 1.0Di + 1.0Wi 60° Wind -5.06 1a -4.62 64.90 2.11 1b -0.29 11.29 -0.16 1 -0.57 47.031.2D + 1.0Di + 1.0Wi 90° Wind -3.26 1a -5.68 78.20 2.95 1b -0.04 15.87 0.31 1 0.00 104.391.0D + 1.0W Normal Wind -10.45 1a 2.06 -27.62 -2.70 1b -2.06 -27.62 -2.70 1 -1.18 57.931.0D + 1.0W 60° Wind -5.62 1a -5.46 57.92 1.79 1b -6.10 -66.70 -3.52 1 -1.40 16.381.0D + 1.0W 90° Wind -1.41 1a -8.00 89.40 3.82 1b -5.59 -56.63 -2.41 Max Reactions Max Uplift: Max Down: -321.60 Leg Overturning 376.60 Max Shear:37.35 Moment:8346.05 Total Down: Total Shear: 58.99 62.58 (kips) (kips) (kips) (ft-kips) (kips) (kips) Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Analysis Summary Structure:NC01659-B-SBA Site Name:Olivia Height:250.00 (ft) 3/29/2017 Page: 16 Code:EIA/TIA-222-G Exposure:C Gh:0.85 Base Elev:0.000 (ft) Crest Height:0.00 Site Class: IIStruct Class: D - Stiff Soil Topography:1 Max Reactions Max Uplift: Max Down: -321.60 Leg Overturning 376.60 Max Shear:37.35 Moment:8346.05 Total Down: Total Shear: 58.99 62.58 (kips) (kips) (kips) (ft-kips) (kips) (kips) Max Usages Max Leg: 83.0% (1.2D + 1.6W Normal Wind - Sect 4) Max Diag: 100.0% (1.2D + 1.6W 90° Wind - Sect 2) Max Horiz: 86.0% (1.2D + 1.6W 90° Wind - Sect 2) Load Case Elevation (ft) Deflection (ft) Twist (deg) Sway (deg) Max Deflection, Twist and Sway 0.9D + 1.6W 94 mph Wind at 60° From Face 220.00 2.0889 0.1120 1.3669 234.72 2.4588 0.1266 1.4514 249.63 2.8505 0.1588 1.5441 250.00 2.8606 0.1589 1.5541 0.9D + 1.6W 94 mph Wind at 90° From Face 220.00 2.1116 -0.0988 1.3796 234.72 2.4844 -0.0982 1.4700 249.63 2.8794 -0.0975 1.4576 250.00 2.8890 -0.0975 1.4643 0.9D + 1.6W 94 mph Wind at Normal To Face 220.00 2.1835 0.0857 1.4175 234.72 2.5666 0.0847 1.5047 249.63 2.9743 0.0811 1.8137 250.00 2.9857 0.0809 1.8257 1.0D + 1.0W 60 mph Wind at 60° From Face 220.00 0.5046 0.0157 0.3259 234.72 0.5926 0.0137 0.3459 249.63 0.6860 0.0128 0.3648 250.00 0.6883 0.0127 0.3667 1.0D + 1.0W 60 mph Wind at 90° From Face 220.00 0.5102 -0.0175 0.3296 234.72 0.5990 -0.0146 0.3504 249.63 0.6931 -0.0119 0.3428 250.00 0.6953 -0.0119 0.3440 1.0D + 1.0W 60 mph Wind at Normal To Face 220.00 0.5275 0.0155 0.3389 234.72 0.6190 -0.0129 0.3588 249.63 0.7159 -0.0104 0.4304 250.00 0.7186 0.0103 0.4331 1.2D + 1.0Di + 1.0Wi 30 mph Wind at 60° From Face 220.00 0.2151 0.0057 0.1382 234.72 0.2513 0.0044 0.1432 249.63 0.2902 0.0033 0.1542 250.00 0.2912 0.0032 0.1544 1.2D + 1.0Di + 1.0Wi 30 mph Wind at 90° From Face 220.00 0.2161 -0.0066 0.1385 234.72 0.2525 -0.0050 0.1447 249.63 0.2915 -0.0035 0.1466 250.00 0.2924 -0.0035 0.1466 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. 1.2D + 1.0Di + 1.0Wi 30 mph Wind at Normal From Face 220.00 0.2191 0.0057 0.1395 234.72 0.2561 0.0043 0.1463 249.63 0.2956 0.0030 0.1662 250.00 0.2967 -0.0030 0.1675 1.2D + 1.6W 94 mph Wind at 60° From Face 220.00 2.0943 0.1124 1.3715 234.72 2.4654 0.1271 1.4566 249.63 2.8586 0.1594 1.5506 250.00 2.8688 0.1596 1.5607 1.2D + 1.6W 94 mph Wind at 90° From Face 220.00 2.1171 -0.0992 1.3844 234.72 2.4911 -0.0986 1.4752 249.63 2.8876 -0.0979 1.4639 250.00 2.8972 -0.0979 1.4707 1.2D + 1.6W 94 mph Wind at Normal To Face 220.00 2.1891 0.0860 1.4226 234.72 2.5736 0.0851 1.5101 249.63 2.9828 0.0814 1.8197 250.00 2.9942 0.0812 1.8318 Copyright © 2017 by Tower Engineering Solutions, LLC. All rights reserved. Customer Name: Site Name: Site Nmber: Engr. Number: Drawings/Calculations Analysis 3 Legs 0.00 (1). Individual Leg:0.50 Axial Load (Kips):376.6 Uplift Force (Kips):321.6 Shear Force (Kips):37.3 (2). Tower Base:10 #4 Total Vertical Load (Kips):59.0 Total Shear Force (Kips):62.6 24.0 22 #9 Moment (Kips-ft):8346.1 9.0 Foundation Geometries:27 #7 27.0 Mods required -Yes/No ?:No 27 #7 6.0 Pier Height A. G. (ft.):0.50 Tower center to mat center (ft):3.89 Depth of Base BG (ft.):9.0 # Length of Pad (ft.):35 Width of Pad (ft.):35 3.50 Thickness of Pad (ft):3.50 27 #7 27 #7 7.794 Mat Center Concrete Strength (psi):4000 Steel Elastic Modulus:29000 ksi (W)3.89 Tower Center Vertical bar yield (ksi)60 Tie steel yield (ksi):36 35.0 27.0 Vertical Rebar Size #:9 Tie / Stirrup Size #:4 Qty. of Vertical Rebars:22 Tie Spacing (in):12.0 Pad Rebar Yield (Ksi):60 Pad Steel Rebar Size (#):7 15.588 Concrete Cover (in.):3 Unit Weight of Concrete:150.0 pcf Rebar at the bottom of the concrete pad:23.383 Qty. of Rebar in Pad (L):27 Qty. of Rebar in Pad (W):27 Rebar at the top of the concrete pad:35.0 (L) Qty. of Rebar in Pad (L):27 Qty. of Rebar in Pad (W):27 Soil Design Parameters: Soil Unit Weight (pcf):115.0 Soil Buoyant Weight:50.0 Pcf Water Table B.G.S. (ft):24.0 Unit Weight of Water:62.4 pcf Ultimate Bearing Pressure (psf):10500 (W)Mat Center Tower Center Notes: 35.0 1. Dimension unit in sketches is in feet. Engineer Login ID: Foundation Info Obtained from: Analysis or Design? 32294 NC01659-B-SBA 17.5 Base Reactions (Factored): Diameter of Pier (ft.): Material Properties and Reabr Info: Number of Tower Legs: Leg distance (Center-to-Center ft.): 5.816 Rama K. 6.0 TES 3/29/2017Mat Foundation Design for Self Supporting Tower Date Engineer Name: EIA/TIA Standard:EIA-222-G Structure Height (Ft.):250 SBA Communications Corp Allowable overstress %:5.00%TES Engr. Number:Page 2/2 Date: Apply 1.35 for e/w per G:1.35 Foundation Analysis and Design:Uplift Strength Reduction Factor:0.75 Compression Strength Reduction Factor:0.75 6270.97 Total Dry Soil Weight (Kips):721.16 0.00 Total Buoyant Soil Weight (Kips):0.00 721.16 Weight from the Concrete Block at Top (K):0.00 4796.44 Total Dry Concrete Weight (Kips):719.47 0.00 Total Buoyant Concrete Weight (Kips):0.00 719.47 Total Vertical Load on Base (Kips):1499.62 Load/ Capacity Ratio Calculated Maxium Net Soil Pressure under the base (psf):2311.11 <Allowable Factored Soil Bearing (psf):7875 0.29 OK! Allowable Foundation Overturning Resistance (kips-ft.):23722.2 >Design Factored Momont (kips-ft): 9005 0.38 OK! Factor of Safety Against Overturning (O. R. Moment/Design Moment):2.63 OK! Check the capacities of Reinforceing Concrete: Strength reduction factor (Flexure and axial tension):0.90 Strength reduction factor (Shear):0.75 Strength reduction factor (Axial compresion):0.65 Wind Load Factor on Concrete Design:1.00 (1) Concrete Pier: Load/ Capacity Ratio Vertical Steel Rebar Area (sq. in./each): 1.00 Tie / Stirrup Area (sq. in./each):0.20 Calculated Moment Capacity (Mn,Kips-Ft):2300.6 >Design Factored Moment (Mu, Kips-Ft)224.1 0.10 OK! Calculated Shear Capacity (Kips):455.4 >Design Factored Shear (Kips):37.3 0.08 OK! Calculated Tension Capacity (Tn, Kips):1188.0 >Design Factored Tension (Tu Kips):321.6 0.27 OK! Calculated Compression Capacity (Pn, Kips):7159.5 >Design Factored Axial Load (Pu Kips):376.6 0.05 OK! Moment & Tension Strength Combination:0.10 OK!Check Tie Spacing (Design/Req'd):1 OK! Pier Reinforcement Ratio:0.005 (2).Concrete Pad: One-Way Design Shear Capacity (L or W Direction, Kips):1536.5 >One-Way Factored Shear (L/W-Dir Kips 169.5 0.11 OK! One-Way Design Shear Capacity (Diagonal Dir., Kips):1627.8 >One-Way Factored Shear (Dia. Dir, Kips 447.7 0.28 OK! Punching Failure Capacity (Kips):1497.2 >Punch. Failure Factored Shear (K):376.6 0.25 OK! Lower Steel Pad Reinforcement Ratio (L or W-Direct. ):0.0010 Lower Steel Reinf. Ratio (Dia. Dir.):0.0009 Lower Steel Pad Moment Capacity (L or W-Dir. Kips-ft):2786.4 >Moment at Bottom ( L-Direct. K-Ft):604.3 0.22 OK! Lower Steel Pad Moment Capacity (Dia. Direction,K-ft):2673.7 >Moment at Bottom ( Dia. Dir. K-Ft):2286.1 0.86 OK! Upper Steel Pad Reinforcement Ratio (L or W -Direction):0.0010 Upper Steel Reinf. Ratio (Dia. Dir.):0.0009 Upper Steel Pad Moment Capacity (L or W-Dir., Kips-ft):2786.4 >Moment at the top (L-Dir Kips-Ft):202.7 0.07 OK! Upper Steel Pad Moment Capacity (Dia. Direction, K-ft):2673.7 >Moment at the top (Dia. Dir., K-Ft):759.5 0.28 OK! Reinforcement Ratio is satisfied per ACI 32294 Total Effective Soil Weight (Kips): Total Dry Concrete Volume (cu. Ft.): Total Buoyant Concrete Volume (cu. Ft.): Total Effective Concrete Weight (Kips): Check Soil Capacities: Total Dry Soil Volume (cu. Ft.): Total Buoyant Soil Volume (cu. Ft.): 3/29/2017