Loading...
FM REVIEW SPRINKLER Harnett (--Th COUNTY * ® 1 Ospe QUO I/{:T Y �f�1 EMawep Services ,art Plan Review, Inspection, and Permit Fees Application Number 17-50041101 $200.00 0 Explosive Material (90 Days) $ - $100.00 ❑ Explosive Materials (72 Hours) $ - $100.00 0 Fireworks Public Display $ - $50.00 E Final Inspection $ - $35.00 +$2.O0per device ❑ Fire Alarm Testing $ - $35.00 +$2.00 per nozzle ❑ Fixed Fire Suppression $ - $75.00 0 Insecticide Fog/Fumigation $ - $100.00 0 Pipe Test/UST/AGST $ - $50.00 ❑ Plans up to 5000 sq ft $ - $100.00 0 Plans 5001 sq ft to 10,000 sq ft $ - $150.00 E Plans 10,001 sq ft to 25,000 sq ft $ - $250.00 ❑ Plans 25,001 sq ft and over $ - $35.00 +2.00 per head EJ Sprinkler Certification Test $ 35.00 $50.00 ❑ Standpipe Testing $ - ❑ Special Assembly $50.00 (ie.amusement buildings,carnivals,fairs) $ - $75.00 ❑ Tents/Canopies/Air Supported Structure $ - $100.00 ❑ Tank Installation (charge for each tank) $ - $100.00 ❑ Tank Removal (charge for each tank) $ - 26 Total Devices/Heads $ 52.00 Total Cost S 87.00 Code Enforcement Official Rodney Daniels 4/25/2017 HCFM Office of the Flre Marshal P.O. Box 370 Lillington, N.C. 27546 (910)493.7580 Permit Certificate Business Name: CAMPBELL UNIVERSITY SMITH BUILDING Address: 4150 US 421 S LILLINGTON, NC 27546 Phone: The following permit has been issued: Permit No. 17-50041101 Type: 044 Sprinkler System Permit Issued Date: 04/25/2017 Effective Date: 04/25/2017 Expiration Date: 10/25/2017 This permit certificate has been issued for[ ]construction/[ ]operational purposes located at the above business location.This permit has been issued and will be enforced in accordance with section tog of the N.C.State Fire Prevention Code. Please contact our office for any further questions regarding this permit. 2 �9L��GJ //Z Ili Inspector: R ne Keith Daniels Y Date 04/25/2017 Page 1 Harnett Thrm P,. :,HTY ® Enw•s�rs.wu wr.�••nt r : ., (FMA r.•nt Fire Marshal Division April 25, 2017 Re: Campbell University Smith Hall 4350 US 421 Lillington, NC 27546 Application Number 17-50041101 (Sprinkler Plan Review) Brett Strickland, Thank you for submitting the plans for the new Smith Hall 4'h floor sprinkler up fit. The plans have been carefully reviewed by a qualified code enforcement official to examine for compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 901.2.1 State of Compliance. o Before requesting final approval of the installation, where required by the fire code official, the installing contactor shall furnish a written statement to the fire code official that the subject fire protection system has been installed in accordance with the manufacture's specifications and the appropriate installation standard. Any deviations from the design standards shall be noted and copies of the approvals for such deviations shall be attached to the written statement. o All work shall be performed in accordance with NFPA 13 and the NCSFC. • 901.5 Installation acceptance testing. o All piping and attached appurtenances subjected to system working pressure shall be hydrostatically tested at 200 psi or 50 psi in excess of the system working pressure, whichever is greater, and shall maintain that pressure without loss for 2 hours. This test is required to be witnessed by a representative from the Harnett County Fire Marshal's Office. o A contractor's material and test certificate shall be furnished by the trained representative of Crossroads Fire Protection before final approval. Harnett COUNTY A Emergency �� _, :�:,. (FAO rys...�ww wwvhr'rrt.arq • Notes o A sprinkler system construction permit is required. o Please schedule all inspections through the Fire Marshal's Office. o 910-893-0743 Thank you again for submitting the plans for the Smith Hall 4'h floor sprinkler up fit. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office. Sincerely, Rodney Daniels Chief Deputy Fire Marshal