Loading...
Hammons Load CalAlternative Power Sales and Rental 512 OLD APEX ROAD CARY, NC 27511 (919) 467-8001 www.alternativepower.com Sizing Report Sizing Information for: Don Hammons 17 Valor Circle Bunnlevel, NC 28323 Rated Nominal Voltage 240 Generator Fuel Choice Propane Sizing Method (NEC 220)Part IV (Part III required for selected circuit implementation, Both valid for whole house) General Lighting & Receptacles Load (kW) Square Footage Being Covered (ft^2)3300 9.9 Small Appliance Circuits (20 amps) Kitchen Circuits 2 3 Laundry Circuits 1 1.5 Fixed-In-Place Appliances & Motors Managed Loads Estimated (kW) Nameplate (amps)240 V Load (kW) Dryer 5.5 X 5.5 Microwave 1.3 1.3 Water Heater X 5.0 X 0.0 Dishwasher 1.5 1.5 Freezer 0.8 0.8 Refrigerator 0.8 0.8 Sump Pump 0.5 0.5 Refrigerator 0.8 0.8 Air Conditioning & Cooling Managed Loads Estimated (kW) Nameplate (amps)240 V Load (kW) Heating & Heat Pumps Managed Loads Estimated (kW) Nameplate (amps)240 V Load (kW) Heat Pump (2.0 Ton)X 2.0 X 0.0 Heat Pump Electric Element X 7.0 X 0.0 Heat Pump (2.0 Ton)X 2.0 X 0.0 Heat Pump Electric Element X 7.0 X 0.0 Transient Requirement Estimated (LRA) Actual (LRA) Utilized (LRA) Largest Motor's Starting Amps (LRA)58 58 58 Summary NEC Load Load (kW) NEC Required General Lighting & Receptacles 14.4 Fixed-in-Place Appliances & Motors 11.2 Sum of all General Loads 25.6 16.2 Cooling 0 0 Heating (w/demand factors)0 0 Larger of Heating & Cooling 0 0 Sizing based on requirements of NEC Article 220, Part IV 16.2 Elevation 0 ft Minimum size generator for motor starting requirements 7 BTU load required 324000 20 kW Generac Model Generator Recommended