FM PLAN REVIEW rP' "` Harnett a .•$X, C O U N T Y �.,.w,......wy Plan Review, Inspection, and Permite Fees Application Number : 17-50041183 $100.00 ❑ DRB Major Sub Division Prelim Site Plans $ - $200.00 ❑ Explosive Material (90 Days) $ - $100.00 ❑ Explosive Materials (72 Hours) $ - $100.00 ❑ Fireworks Public Display $ - $50.00 O Final Inspection $ 50.00 $35.00 +$2.00 per device ❑ Fire Alarm Testing $ - $35.00 +52.00 per nozzle ❑ Fixed Fire Suppression $ - $75.00 ❑ Insecticide Fog/Fumigation $ - $100.00 ❑ Pipe Test/UST/AGST $ - $50.00 ❑ Plans up to 5000 sq ft $ - $100.00 ❑ Plans 5001 sq ft to 10,000 sq ft $ - $150.00 2 Plans 10,001 sq ft to 25,000 sq ft $ 150.00 $250.00 D Plans 25,001 sq ft and over $ - $35.00 +2.00 per head ❑ Sprinkler Certification Test $ - $50.00 ❑ Standpipe Testing $ - ❑ Special Assembly $50.00 (ie.amusement buildings, carnivals,fairs) $ - $75.00 Tents/Canopies/Air Supported Structure $ $100.00 Tank Installation (charge for each tank) $ $100.00 ❑ Tank Removal (charge for each tank) $ - Total Devices/Heads $ - Total Cost $ 200.00 Code Enforcement Official Jeff D. Johnson 4/21/2017 Harnett COUNTY M1 E""'°'"`r Sermon Department V Fire Marshal Division April 21, 2017 Re: Campbell University Admissions Building 40 T.T. Lanier Street Buies Creek, NC 27506 Application Number 15-50041183 To Whom It May Concern, Thank you for submitting the plans for the new admissions building. The plans have been carefully reviewed by a qualified code enforcement official to examine for compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. • 506.1 Knox Box o A Knox Box is required to be installed on the building. Please see the link below to order Knox box. Paper order form available upon request. o https://www.knoxbox.com/store/Knox-Box-3200-Series.cfm • 503.2.3 Fire Apparatus Access Road Surface. o Fire department access roads shall be designed and maintained to support the imposed loads of fire apparatus and shall be surfaced to provide all-weather driving capabilities. • 503.3 Markings. o Where required by the fire code official approved signs or other approved markings that include the words NO PARKING — FIRE LANE shall be provided for fire apparatus access roads to identify such roads or prohibit the obstruction thereof. • 505.1 Address Numbers o The physical address shall be installed on the building so that it is visible from the approach side, minimum size of 6 inch. o The numbers shall be of contrasting colors. NA Harnett COUNTY * Q t^, emuy Somas DepvMwnt //`Y•IfIN rgrm NO. • 906.1 Fire Extinguishers required. o A minimum 2A1OBC classification of fire extinguisher is required on each floor and located so that the maximum travel distance to reach an extinguisher does not exceed 75ft. o Fire Extinguishers shall be located in approved cabinets along corridors and hallways. o Also, a minimum 408C classification fire extinguisher is required inside the elevator equipment room. o All fire extinguishers shall be mounted not higher than 5ft. above the finished floor and in accordance with NFPA 10. • 907.1.2 Fire Alarm System Shop Drawings o Shop drawings from the licensed installing contractor shall be submitted prior to work beginning. Provide manufacture cut-sheets on all devices and equipment, battery calculations, voltage drop, and all other relative requirements of 907.1.2 o A rough in inspection is required. o A final acceptance test is required to be witnessed by a fire marshal (100%). • 901.6.1 Sprinkler System Shop Drawings o Sprinkler system shop drawings shall be submitted by the installing contractor prior to work beginning. Provide manufacture cut-sheets on all devices and equipment, current water flow test results by engineer or Licensed Fire Sprinkler Contractor. o A rough in inspection is required. o A final acceptance test is required to be witnessed by a fire marshal. • 913.1 Fire Pump o A construction permit is required for the installation of the complete fire pump, submit design sheets, details and manufacture installation information on the complete system at time of permit application and before commencement of any work. o The fire pump design and installation shall be in Accordance with NFPA 20 and Section 913 of the NC State Fire prevention Code. o Acceptance/performance test is required to be witness by a fire marshal. • 912.2 Fire Department Connection Location o The location of the fire department connections shall be approved by the fire chief. Consult with fire chief to ensure location is acceptable for fire ground operations. o Approved signs for fire department connection will be required at time of final inspection. Harnett ♦ COUNTY {tM) ServicesEminency Serv, l Department ® air WWVJIYM@.OIQ • 1006 Illumination emergency power. o In the event of power supply failure, an emergency electrical system shall automatically illuminate corridors, exit enclosures in buildings required to have two or more exits. (Stair 1 &Stair 2) • 703.5 Identification o Walls and partitions required to have protected openings shall be permanently identified with signs or stencils. (Example "2- hour Fire Barrier Protect All Openings") • Comments o A final fire inspection is required. o Schedule all fire inspections through the Fire Marshal's Office. (919)893-0741 Thank you again for submitting the plans for the new admissions building. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office. SinIIYccerely, C‘tf6D. John Deputy Fire Marshal